Records from 1984 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 158
18 March 2026
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8328407
3 November 2025
Vessel Attendance · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8264288
5 May 2025
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8129338
25 June 2024
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7948223
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7912997
17 November 2023
Administrative Inspection · Special Consideration · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7836746
16 November 2023
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7826827
14 September 2023
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7791799
3 September 2023
Type not recorded
No type recorded · Station Ketchikan · USCG Arctic District (CGD-A) · Activity 7784417
3 September 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7784637
13 July 2023
Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7742800
9 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7685319
30 May 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7460718
29 September 2021
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7353783
1 April 2021
Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7167244
6 March 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7151218
28 May 2020
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6962945
7 April 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6936654
1 October 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6826899
8 May 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6680594
5 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6658241
28 March 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6651702
30 January 2019
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6618298
9 October 2018
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6558834
12 April 2018
COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6392754
11 October 2017
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6287189
10 July 2017
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6206801
10 April 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6121372
24 January 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6077300
11 May 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5875477
2 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5872507
22 October 2015
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5749663
1 October 2014
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4997879
22 June 2014
Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4898283
19 June 2014
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4922449
2 June 2014
Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4878575
31 May 2014
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4878351
12 May 2014
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4857637
15 November 2010
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3891609
13 January 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3393431
8 December 2008
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3340325
13 June 2008
Examination of Repairs · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3236014
4 June 2008
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3227704
4 June 2008
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3227708
6 May 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3200316
4 March 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3160380
9 June 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2968178
8 May 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2925193
12 March 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2885559
25 April 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2633003
21 March 2006
Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2606473
16 February 2006
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2591372
13 October 2005
Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2525819
20 July 2005
Examination of Repairs · Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2433658
19 July 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2433820
12 July 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2424375
14 May 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2375048
27 April 2005
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2343249
17 March 2005
Hull Examination · Internal Structural Exam · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2313102
26 September 2004
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2207891
20 September 2004
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2200410
26 July 2004
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2147355
14 June 2004
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2098489
11 March 2004
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2022982
27 August 2003
Examination of Repairs
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1889324
26 August 2003
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1928095
25 August 2003
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1907970
5 May 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1787247
28 February 2003
Annual Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1750881
13 June 2002
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1630413
3 June 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1625814
29 April 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1610510
21 February 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1475419
25 September 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 71153
14 July 2001
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 79829
12 March 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 49660
6 March 2001
Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366220
18 January 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1437832
16 July 2000
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1051616
15 July 2000
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 143413
9 July 2000
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 165825
25 April 2000
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1462080
24 April 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 47579
7 March 2000
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1460392
24 February 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1448062
24 June 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 449589
4 March 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402800
1 February 1999
Hull Examination · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429064
1 January 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1126000
22 July 1998
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 79564
3 July 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 105607
16 March 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1368641
30 January 1998
Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416617
27 January 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1117374
30 September 1997
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 783130
16 August 1997
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1398753
15 August 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 27224
6 February 1997
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390438
21 January 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360704
14 July 1996
Examination of Repairs · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1091030
11 July 1996
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 139914
29 February 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884863
31 January 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884856
25 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 186770
25 September 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189836
6 April 1995
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 840983
19 October 1994
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 653163
29 August 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1455185
28 August 1994
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 65124
9 August 1994
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 862043
26 July 1994
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 166306
26 July 1994
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 862198
4 May 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1168810
2 May 1994
Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1176950
30 April 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 42342
22 March 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426881
6 January 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450816
11 September 1993
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 833301
8 September 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1377044
1 April 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465099
1 April 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1472396
26 February 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 952778
26 February 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 957849
21 November 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653165
17 October 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653161
6 August 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1251013
24 July 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 674699
15 April 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904090
20 February 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1216579
24 May 1990
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 910097
13 April 1990
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1232347
30 January 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229167
12 October 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1032151
22 August 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 895246
4 April 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1349637
28 September 1988
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1195166
18 May 1988
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1352350
2 May 1988
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348139
15 October 1987
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1016110
21 September 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1015878
6 May 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1325209
14 February 1987
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1013671
5 January 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310213
3 December 1986
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330291
26 November 1986
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1020368
25 October 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1010581
17 October 1986
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1009643
8 January 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 993497
13 December 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997837
13 December 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1307599
12 December 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995655
30 October 1985
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987577
11 August 1985
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 987426
28 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987816
10 January 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978406
21 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 977054
21 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1282778
1 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 974936
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2025
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Make ready for inspection and testing the following items:
Watchman alarm, interconnected fire detection system, installed liferafts, fire pump and hoses, emergency lighting, fixed fire fighting system shutdowns.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: All required items were available for testing and testedx SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2025
Resolved
Each length of hose must: (1) Be lined commercial fire hose that conforms to Underwriters' Laboratories, Inc., Standard 19 or Federal Specification ZZ-H-451E. A hose that bears the Label of Underwriters' Laboratories, Inc., as lined fire hose is accepted as conforming to the requirement. Fire station #4 hose had multiple pin holes located at the hydrant connection.
46 CFR 181.15-10
Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Fire hose was replaced with a brand new one and tested SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 May 2025
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters' Laboratories, Inc. "Marine Type"
label, or shall be constructed in accordance with the requirements of other recognized testing laboratories.
Several deck 02 outdoor lights were missing the protective guard around the globe or were found broken.
46 CFR 183.10-20(I)
Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: All identified lighting issues were repaired SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Fire detection sensor in the steering gear room was missing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Missing detector was replaced and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment. Fuel shutoff valves were replaced but the emergency fuel pull cable was not connected to the valves and could not be tested.
46 CFR 182.20-40(3) - Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Fuel shut off cables were connected and tested SAT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 May 2025
Resolved
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Both engine room fans were supplying air to the engine room with no exhaust ventilation.
46 CFR 182.20-45(c) - Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Ventillation was repaired and provided intake and exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 May 2025
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Where such openings would endanger the vessel under adverse weather conditions, means shall be provided to close them. All ventilation pull cables were too short and could not be locked into place properly.
46 CFR 177.20(a) - Old T
Action required: 66 - Prior to drilling or production operations
Resolved 12 May 2025
Resolution: All ventillation were adjusted properly and allowed for proper closure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 May 2025
Resolved
The lights prescribed by these Rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary. Stern light was inoperable.
33 CFR 83.20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Stern light was repaired and tested SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 May 2025
Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered. Escape ladder from aft crew 100's space was not properly secured at the bottom of the escape ladder.
46 CFR 177.15-1 Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Ladder was properly secured to the deck.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 May 2025
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system speakers were inoperable in the passageway in crew aft 100's.
46 CFR 184.610(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Passageway speakers were repaired and tested SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 5 May 2025
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock.
The following electrical issues were identified:
- Electrical outlet in crew berthing forward 100's outboard room did not have a cover installed.
- 02 florescent lights in crew berthing forward 100's did not have bulbs installed and were missing the covers.
- Crew berthing room #107 had a broken electrical switch and broken light cover.
- Crew berthing room #115 had a broken electrical plug cover.
- Crew berthing room #114 had a missing light cover and missing light bulb.
46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: All identified electrical issues were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Forepeak high water alarm was inoperable.
46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Bilge high water alarm was replaced and tested SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2025
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Reefer and freezer were not properly secured in aft food storage space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Equipment was properly secured.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 5 May 2025
Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Several passenger staterooms were missing passenger safety bills as required.
46 CFR 185.515
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: All missing passenger safety bills were replaced.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 5 May 2025
Resolved
The station bill must be posted at the operating station and in a conspicuous location in each crew accommodation space. Crew accommodation spaces were missing the required station bill.
46 CFR 185.514
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2025
Resolution: Station bills were properly placed in the crew berthing passageway with bunk cards placed in each berthing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 03 life rings onboard were found with severe UV damage and cracking.
46 CFR 176.808(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: All ring life buoys have been replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 May 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit was found expired.
46 CFR 185.740(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Hydrostatic release unit was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. 02 fire extinguishers were found past due on its inspection.
46 CFR 176.810(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Fire extinguishers were serviced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Starboard air conditioning space electrical enclosure was missing the cover and wires were found exposed.
46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Electrical enclosure cover was installed properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Aft engine room bilge alarm float switch was found broken.
46 CFR 182.530(a)(12)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 May 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment Including the following: Inspection of piping, controls, and valves. Fire main branch valve in engine room was leaking excessively at the bonnet.
46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: Leaky fire main branch valve was replaced in kind. Additional testing sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped Double hose clamping is required where practicable. Multiple vital systems on port MDE had single hose clamps.
46 CFR 182.410(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2024
Resolution: All vital system non metallic hoses were double clamped.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 May 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Shower light fixture in room 111 was missing the globe.
46 CFR 183.410
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Missing globe was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 14 May 2024
Resolved
Combustibles and other foreign materials are not allowed within ventilation ducts. Galley griddle exhaust ventilation had excessive build up of grease.
46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Galley hood fans and ventilation duct was degreased.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 May 2024
Resolved
A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. All weather deck public address speakers were inoperable.
46 CFR 184.610(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: All weather deck public address system speakers were retested sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. GFCI outlets were not installed next to the sink in "TEBENKOF" and WRANGEL" passenger accommodation spaces.
46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: GFCI outlets were installed next to sink.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 May 2023
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) very power-driven vessel of 20 meters or over in length while navigating. Vessels Bridge to Bridge Radio Certificate was expired.
47 CFR 80.1001
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: FCC inspection was completed and cetificate posted on the bridge.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 9 May 2023
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessels FCC station license was expired.
47CFR 80.13
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: Station license was renewed and posted on the vessel.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 9 May 2023
Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. Vessels FCC Safety Radiotelephony Certificate was expired.
47 CFR 80.59(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: FCC inspection was completed and certificate was posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2023
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Installed CO2 system did not have the required instructions or schematic of the system.
46 CFR 185.612(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: Simple instructions and diagram were placed at the pull station and at the location of the bottles in the lazarette.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical enclosure in the AC room was missing the cover and had exposed wiring.
46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: Missing cover was installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2023
Resolved
A vessel of more than 19.8 meters (65 feet) in length must have at least one fire axe located in or adjacent to the primary operating station. A fire ax was not located in or adjacent to the operating station.
46 CFR 181.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: A fire ax was placed at the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Pilot [name withheld], Tides and Currents. Vessels nautical publications were not updated.
46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: All required navigational publications were updated on the bridge computer.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2022
Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Nonconductive matting was missing in front of main switchboard.
46 CFR 183.330(f)
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: Non conductive matting was added in front of switchboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Light fixture in lazarette overhead was secured with electrical tape.
46 CFR 183.01-15
OLD T
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: Light fixture was properly secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Electrical junction box in lazarette overhead was missing cover plate.
46 CFR 183.01-15
OLD T
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: Cover plate installed on junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 June 2022
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydrostatic release units for both life rafts were improperly installed preventing a float free arrangement.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: HRU's were properly installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 June 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Starboard quarter 2nd deck had 02 cracked vertical stancions at the acocomodation access door.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2022
Resolution: Welds were repaired SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 June 2022
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection. Emergency escape was not properly marked.
46 CFR 185.30-15 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Emergency escape was properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2022
Resolved
The Rules concerning lights (§§ 83.20 through 83.31) shall be complied with from sunset to sunrise, and during such times no other lights shall be exhibited. All navigation light lenses were cracked and discolored preventing the intensity of the lights from achieving the required 2NM range. Vessel is restricted to daylight operations and periods of unrestricted visibility.
33 CFR 83.20(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: NAV Light lenses were cleaned and intensity of light has increased. O/O has placed a purchase for new lenses to be installed upon receipt.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Forward storage space passageway and space has several overhead lights without protective covers installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Protective covers have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2022
Resolved
For items not covered by standards in this subchapter,
inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspectionsm as good marine practice. Forward lounge bar had several CO2 beverage bottles not properly secured.
46 CFR 176.25-1 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: CO2 beverage bottles have been properly secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
All cable and wire must Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Wire run is not properly supported in forward storage space overhead.
46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Wire run has been properly supported.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Electrical outlet in forward storage space does not have a cover plate attached.
46 CFR 183.01-15
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Cover plate has been installed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 June 2022
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Forward 100's passageway PA system speakers were inoperable.
46 CFR 184.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: PA system has was tested SAT. All speakers are functional.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Main dining room aft overhead light switches were missing covers.
46 CFR 183.01-15
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Covers have been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 June 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Gen Board Bus 2 Panel 3 had an open slot requiring a blank.
46 CFR 183.01-15
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Blank installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2022
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shutoff handles were not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Fuel shutoffs have been properly marked.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2022
Resolved
For items not covered by standards in this subchapter,
inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspections as good marine practice. Ice machine located outside the galley is not properly secured.
46 CFR 176.25-1
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Ice machine has been properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2022
Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter. Lazzarette had excessive hydraulic fluid in the bilge from recent maintenance.
46 CFR 176.25-50
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Space has been properly cleaned.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 June 2022
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close them. Port and starboard side ventilation closures require gaskets due to large gap when closed.
46 CFR 177.20-1
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Gaskets have been installed on the ventilation closures.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 June 2021
Resolved
Extensive wastage to longitudal framing below room 103 shower. Crop and renew to original condition.
Action required: 705 - Other - as specified
Resolved 30 June 2021
Resolution: NDT Conducted - air lance/vac box sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 March 2021
Resolved
Prove proper operation of engine room fixed extinguishing system machinery shut-downs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2022
Resolution: Engine room ventilation pressure switch tested SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2021
Resolved
Identify and make permanent repairs to all exhaust leaks in engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 June 2022
Resolution: All exhaust leaks repaired SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 April 2020
Resolved
While the vessel is engaged in towing the vessel must be controlled by a licensed Master or Mate of towing. Vessel has until April 1st 2022 to man vessel with licensed Master and Mate of towing.
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 2 November 2021
Resolution: Cleared. SEC JUN made determination that vessel not engaged in the service of towing commercially.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 April 2020
Resolved
Vessel must provide updated stability calculations to include towing to Coast Guard Marine Safety Center to update vessels stability letter by April 1st 2022
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 2 November 2021
Resolution: Cleared. SEC JUN made determination that vessel not engaged in the service of towing commercially.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2020
Resolved
Vessel shall provide correct light and day shape configuration for the tow being conducted prior to towing.
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 2 November 2021
Resolution: Cleared. SEC JUN made determination that vessel not engaged in the service of towing commercially.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 April 2020
Resolved
Vessel shall start and maintain records for towline and terminal gear used for towing astern or alongside prior to towing
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 2 November 2021
Resolution: Cleared. SEC JUN made determination that vessel not engaged in the service of towing commercially.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Provide an interlock on the electrical distribution panel to prevent generators from being simultaneously connected to the switchboard with shore power.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Interlock device has been installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2019
Resolved
Ensure all hot water heaters are properly installed and secured from rolling by straps or other devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 June 2022
Resolution: How water heaters have been properly secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 April 2019
Resolved
Engine room fire detection must be registered visibly and audibly in the pilothouse; system failed to provide an audible alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Witnessed a satisfactory operational test of the engine room heat detection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2019
Resolved
A vessel must be provided with a bilge dewatering system; an operational test of the system failed and one remote operated bilge valve could not be exercised.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Witnessed a satisfactory test of the bilge dewatering system and verified the malfunctioning valve had been serviced and operated properly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 April 2019
Resolved
Piping in excess of 150 degrees F must be suitably insulated, exhaust lagging in the starboard steering room and the port generator was not provided.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Each identified location was provided with new lagging.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 5 April 2019
Resolved
An alarm for fixed gas fire extinguishing systems must be clearly and conspicuously marked; the engine room CO2 siren sign was badly faded and inconspicuously placed.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified a new sign placard was provided and conspicuously placed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 April 2019
Resolved
An exposed hazard such as rotating machinery must be properly protected by a cover; the generators and main engines' flywheels were exposed.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified flywheel covers were provided.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 5 April 2019
Resolved
The name and hailing port must be marked on some clearly visible exterior part of the stern; no name or hailing port were provided.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified the vessel name and hailing port were provided on the exterior stern.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 April 2019
Resolved
A high water alarm must be provided for each space with through hull fittings; the bilge sensor device in the steering room was not properly mounted and inoperable.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified that bilge sensor was mounted and witnessed a satisfactory operational test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 April 2019
Resolved
Lighting fixtures must have a guard and wires must be properly terminated in a junction box; both fwd and aft crew's accommodations were missing lighting fixture covers and both had bear wirs protruding through the ceiling.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified all identified wiring discrepancies were properly addressed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 April 2019
Resolved
Wires and cables must be properly supported and installed in a manner that does not interfere with moving machinery; lighting cables were interfering with the starboard side rudder bar.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified the identified cable was bundled back to prevent interference.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 April 2019
Resolved
Except for vessels limited to daytime operations the compass must be illuminated; the light was inoperable.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified the installation of a new compass light.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 April 2019
Resolved
Conduct drills prior to seasonal operations.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Witnessed underway drills
Engineering › Reduction Gearing/Clutches › Gear
Issued 10 July 2017
Resolved
[name withheld] reported failure of #2 Engine propulsion, likely in the reduction gear. Master instructed to repair proper function of #2 shaft for forward and reverse operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2017
Resolution: [name withheld] attended vessel in Auke Bay to verify proper operation of propulsion on #2 engine.
Engineering › Lubricating Oil Service System › Gauge
Issued 10 April 2017
Resolved
Gauges to indicate L/O pressure shall be provided for propulsion equipment. Repair or renew the port main engine L/O pressure gauge at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified gauge was operating properly.
Communications › Radio Communications › EPIRB
Issued 10 April 2017
Resolved
Each vessel that operates on the high seas mush have Cat 1 EPIRB. Provide and properly install EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified EPIRB was aboard and installed properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 April 2017
Resolved
A vessel must carry and approved or equivalent first aid kit and instructions. Provide an appropriate first aid kit for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified appropriate first kit was aboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017
Resolved
Properly distribute life preservers and mark life preserver stowage in the crew’s accommodations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified PFD's were properly distrubuted and storage locations were marked.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 April 2017
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck for passengers and crew. Correct E-light discrepancies and make available for reinspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verfied emergency lighting instalations were sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 April 2017
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazards. Provide cover for ventilation opening for the Engine Room supply fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified instalation of expanded metal to close off ventalation opening.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 April 2017
Resolved
Complete servicing and maintenance of the engine rooms fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified fixed fire extinguishing system maintenance was completed and system was intact.
Engineering › Fuel Oil Service System › Valve
Issued 10 April 2017
Resolved
Shutoff valve shall be installed at the engine end of the fuel line. Provide shutoff valve for the port main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Port MDE shutoff valves provided by primary fuel filter valves.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 April 2017
Resolved
Each flexible hose designed for use with hose clamps shall utilize two clamps at both ends. Provide an additional clamps for both generator's sea-water piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Verified generator sea water piping was properly fastened.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 January 2017
Resolved
Vessel owners shall minimize accidental personnel contact with energized circuits. Remove the two dead-ended cables in the FWD 100's void, reconnect and protect identified cable next to hatch in aft 100's, and properly terminate large cable in ovhd of aft steering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 10 May 2017
Resolution: Verified cables were removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 January 2017
Resolved
Each conductor shall be with metal supports not more than 24" apart. Properly run and support cable providing powering to aft corridor outlet in the FWD 100's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 10 May 2017
Resolution: Verfied cable was removed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 January 2017
Resolved
Each flexible hose designed for use with hose clamps shall utilize two clamps at both ends. Provide an additional clamp for the port main engine jacket water cooler connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 10 April 2017
Resolution: Verified installation of additional hose clamp.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 January 2017
Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Properly secure open ended piping penetrations in the steering compartment fwd bulkhead stbd of centerline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 3 April 2017
Resolution: 3 decomissioned piping penetrations were capped and 1 wiring penetration was properly sealed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 January 2017
Resolved
Bilges shall be free of excessive accumulation of oil, trash, debris, or other matter that may clog bilge pumping systems. Remove or more appropriately store lagging, tarps, and construction materials in the steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 10 April 2017
Resolution: Verified aft steering compartment bilge rubbish had been removed.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 2 May 2016
Resolved
Provide proper number of IBAs for persons on board. 46CFR180.200
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 10 May 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 May 2016
Resolved
Prove proper closing of exterior galley ventilation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 11 May 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 May 2016
Resolved
Provide vessel name on child life jackets. 46CFR180.71
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 11 May 2016
Construction/Loadline › Structures › Manhole
Issued 2 May 2016
Resolved
Prove proper operation of lounge escape hatch.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 11 May 2016
Communications › Alarms/Indicators › Fire Alarm
Issued 2 May 2016
Resolved
Prove proper operation of audible alarm on bridge alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 11 May 2016
Engineering › Thrusters › Hose
Issued 22 June 2014
Resolved
Bow thurster fitting attached to port main engine failed. Repair or replace fitting.
Action required: 705 - Other - as specified
Resolved 22 June 2014
Resolution: Fitting was replaced and tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 31 May 2014
Resolved
Vessel's starboard engine's forward air throttle system became inop for an unknown reason.
Due 2 June 2014
Resolved 2 June 2014
Resolution: Dirt was removed from the air throttle system which corrected the issue.
Lifesaving › Inflatable Liferafts › Capacity
Issued 13 January 2009
Resolved
Provide life rafts for 200% of vessel passenger capacity, 100% capacity on each side of vessel IAW 46CFR199.201(d)(1)(i).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 30 May 2013
Lifesaving › Rescue Boat › Construction
Issued 13 January 2009
Resolved
Replace rescue boat with Coast Guard approved 46CFR160.156 rescue boart IAW 46CFR199.202(b).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 30 May 2013
Construction/Loadline › Hull › Bottom Plating
Issued 13 January 2009
Resolved
Complete Coast Guard credit dry-dock and internal examination when vessel is removed from layed-up status.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 10 November 2010
Resolution: Performed credit ISE this date.
Engineering › Steering Gear System › Rudder
Issued 4 June 2008
Resolved
Make permanent repairs to stbd rudder and skeg prior to the carriage of pax.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2008
Resolved 13 June 2008
Resolution: Repairs completed to satisfaction of SECSEA OCMI
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 May 2008
Resolved
Prove proper operation of 2 engine room bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2008
Resolved 8 May 2008
Resolution: Replaced leaking seal and cleaned bilge alarm wiring. Witnesses alarm test.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 May 2008
Resolved
Provide separation between child and adult size lifejackets.
Due 6 June 2008
Resolved 8 May 2008
Resolution: Provided wooden board to separate child and adult sizes.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 6 May 2008
Resolved
Repair or replace GPS.
Due 6 June 2008
Resolved 8 May 2008
Resolution: Tech installed software patch.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 May 2008
Resolved
Remove old disconnected emergency fuel shut-off pulls.
Due 6 June 2008
Resolved 8 May 2008
Resolution: pull handles removed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
A - Stbd side IVO fr27; 27" x 24"
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area indicated has been re-newed, as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
B - Stbd side IVO fr24 to fr26; 24" width
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area re-newed as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
C - Stbd side IVO fr26; 18"x8'
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area re-newed as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
D- Stbd side IVO fr24 to fr23; 22"x7' 1"
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area re-newed as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
E - Port side IVO E/R fr35 to fr37 IWO fire and bilge pumps; 78"x50"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Side Shell
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
F - Port side shell IVO fr34 to fr40 at chine; 18"x9' 9"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
G - Port side IVO fr19 to fr20; 8' 10"x43"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
H - Port side IVO fr19 to fr24; 20"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
I - Port side IVO fr19 to fr24 btwn section "H" and keel; 20"x17' 8"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Side Shell
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
J - Port sideshell IVO aft exhaust port; 6'x2' 5"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
K - Port side IVO fr39 to fr44; 2'x4'
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area renewed as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
L - Port side IVO fr21 to fr22; 40"x20"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
M - Port side IVO fr23 to fr24; 24"x24"
Action required: 705 - Other - as specified
Due 15 April 2008
Resolved 15 April 2008
Resolution: Cropped & renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
N - Port side IVO fr24 to fr28; 22"x22' 6"
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area re-newed as per repair plan.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2008
Resolved
The following areas are to be repaired (refer to filed repair plan);
O - Port side IVO fr37 to fr40; 50"x66"
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 4 December 2008
Resolution: Area renewed as per repair plan.
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 March 2007
Resolved
Three sea valves were rejected for improper sealing. These valves include # 35A, a 1.5 inch gate valve on the port side for the graywater system; and # 20Aand #19A, both of which are 2 inch gate valves on the port side for the black water overboard.
Due 12 March 2007
Resolved 12 March 2007
Resolution: Valves will be replaced with new ones.
Construction/Loadline › Hull › Transverse Frame
Issued 10 March 2007
Resolved
2 transverse frames in the engine room were found weakened by large irregular holes cut in them in order to run pipes through. These transverse frames are located beneath the port generator and aft of the starboard bow thruster pump.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Stringer
Issued 10 March 2007
Resolved
Longitudinal stringer in void space in accommodation Rm #107 was found to have a 12 inch area where it is corroded through at the forward end of the void and a 36 inch area where it is corroded through where the stringer meets the aft bulkhead.
Action required: 705 - Other - as specified
Due 12 April 2007
Resolved 23 March 2007
Construction/Loadline › Hull › Side Shell
Issued 11 March 2004
Resolved
The crew noted a small hole in the hull plating at the aft crew quarters. Upon examination, excessive wastage was found on the deck and bulkheads. The issue will be corrected with two deck inserts, a bulkhead insert and a side shell insert.
Action required: 705 - Other - as specified
Due 6 April 2004
Resolved 6 April 2004
Electrical › Electric Generation Source (service)
Issued 21 February 2002
Resolved
Provide circuit breaker with interlock between both generators and shore tie breakers. 46CFR120.322 LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 21 March 2002
Resolved 22 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 21 February 2002
Resolved
Clean or renew the 30X30 metal screen on fuel tank vent. 46CFR450 (d) LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 23 June 2002
Resolved 13 June 2002
Resolution: Renewed screen
Engineering › Fuel Oil Service System
Issued 21 February 2002
Resolved
Install metal plugs in fuel bowls on fuel filters for main engines and generators. 46CFR119.440 LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Due 21 March 2002
Resolved 22 April 2002
Electrical › Electrical Distribution System (service)
Issued 21 February 2002
Resolved
Install two 1/2"knock outs plugs for pressure switches for air compressor in engine room. LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Plugs installed.
Electrical › Lighting (service)
Issued 21 February 2002
Resolved
Remove or terminate wires in port steering room. 46CFR120.340 (g) LEGACY COMPONENT DESC: Conductor
Condition: Improper Installation
Due 23 June 2002
Resolved 13 June 2002
Resolution: Wires removed.
Electrical › Electrical Distribution System (service)
Issued 21 February 2002
Resolved
Provide knock out blanks in the #4 breaker panel. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Blanks provided.
Pollution Prevention/Response › Prevention Equipment
Issued 21 February 2002
Resolved
Label bilge suction line at manifold in engine room. 46CFR119.710 LEGACY COMPONENT DESC: Bilge Manifold
Condition: Unknown
Due 21 March 2002
Resolved 22 April 2002
Electrical › Lighting (service)
Issued 21 February 2002
Resolved
Install light switch cover for over-head switch in aft crew quarters (Port-side) LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Cover provided.
Lifesaving › Inflatable Liferafts
Issued 21 February 2002
Resolved
Post liferaft launching instructions (appropriate for each type of appliance) at each life raft launching station. LEGACY COMPONENT DESC: Markings
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Liferaft instructions posted.
Operations/Management › Drills/Instruction
Issued 21 February 2002
Resolved
Conduct FIRE and MAN-OVERBOARD drill to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2002
Resolved 31 July 2002
Resolution: Conducted fire and abandon ship drills. All sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 February 2002
Resolved
Properly mark all storage locations of lifejackets (In particular state-rooms/ cabin stowage locations). LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 23 June 2002
Resolved 13 June 2002
Resolution: PFD storage marked.
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 February 2002
Resolved
Provide one additional child size PFD to meet the 10% requirement. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Provided child PFD.
Documentation › Safety Management System
Issued 21 February 2002
Resolved
Post a passenger safety bill in each passenger cabin as required by 46 CFR 122.515 LEGACY COMPONENT DESC: Key Shipboard Operations Plans/Instructions
Condition: Unknown
Due 23 June 2002
Resolved 13 June 2002
Resolution: Passenger safety bill posted.
Construction/Loadline
Issued 18 January 2001
Resolved
REMOVE PLASTIC PIPING PENETRATION OF PORT SIDE LAZARETTE WATERTIGHT BULKHEAD. RENEW PIPING IAW APPLICABLE 46 CFR.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 18 January 2001
Resolved
MAKE WATERTIGHT BULKHEAD PENETRATION WATERTIGHT IN WAY OF PORTSIDE LAZARETTE.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Construction/Loadline
Issued 18 January 2001
Resolved
REPLACE TEMPORARILY REMOVED PORTION OF LONGITUDINAL SWASH BULKHEAD IN WAY OF STARBOARD LAZARETTE.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Engineering
Issued 18 January 2001
Resolved
PROPERLY RELAG DIESEL ENGINE EXHAUST MANIFOLD IN WAY OF LAZARETTE.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Fire Fighting
Issued 18 January 2001
Resolved
PROVE PROPER OPERATIONS OF FIRE AND BILGE PUMP PRIOR TO CARRYING PASSENGERS. NOTED FIRE AND BILGE PUMP AND ITS ATTACHED MOTORS WERE REMOVEDFOR RENEWAL.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Engineering
Issued 16 July 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 July 2000
Resolved 17 July 2000
Lifesaving
Issued 25 April 2000
Resolved
Clean and present for inspection the engineroom bilges. Bilges have oil film from standing water.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Fire Fighting
Issued 25 April 2000
Resolved
Remove and replace all damaged structural fire protection insulation in engine space.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Fire Fighting
Issued 24 February 2000
Resolved
CONDUCT MAN OVERBOARD AND EMERGENCY FIRE DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 2000
Resolved 28 March 2000
Construction/Loadline
Issued 16 August 1997
Resolved
Make permanent repairs to bar keel where cropped out forward, at next scheduled drydocking but not later than 30 JAN '98.
Condition: Unknown
Due 16 August 1997
Resolved 16 August 1997
Construction/Loadline
Issued 16 August 1997
Resolved
Continued vessel operation approved. Proceed to drydock for temp repairs.
Condition: Unknown
Due 30 August 1997
Resolved 17 September 1997
Electrical
Issued 6 February 1997
Resolved
PROVIDE MISSING SHIELD ON LUBE OIL FILTER ON NO.1 SSDG.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Engineering
Issued 6 February 1997
Resolved
PROVIDE MISSING SHIELDING OVER WASTE LUBE OIL PUMP.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 6 February 1997
Resolved
REPAIR BULKHEAD INSULATION NEAR THE AIR RECEIVER AND FUEL GUAGE.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Electrical
Issued 6 February 1997
Resolved
PROVIDE PROTECTIVE GUARD ON CRANKSHAFT ON PORT GENERATOR.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Navigation
Issued 6 February 1997
Resolved
DOUBLE NUT OR LOCK NUT LINKAGES ON RUDDER ANGLE INDICATOR FEEDBACK UNIT.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Navigation
Issued 6 February 1997
Resolved
UPDATE COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Lifesaving
Issued 6 February 1997
Resolved
PROVE PROPER OPERATION OF VESSEL GENERAL ALARM SYSTEM.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 6 February 1997
Resolved
PROVIDE DOCUMENTATION OF LOADLINE CERTIFICATE EXEMPTION.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997
Resolved
PROVE PROPER OPERATION OF REVERSE POWER TRIPS ON SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 6 February 1997
Resolved
POST VESSEL COI AND STABILITY INFORMATION IN LOCATION EASILY VIEWED BY PASSENGERS.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 6 February 1997
Resolved
PROVIDE ORIGINAL CREW LICENSES AND STCW ENDORSEMENTS ONBOARD VESSEL.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Engineering
Issued 14 July 1996
Resolved
VSL IS TO REMAIN @ SITKA, AK UNTIL PERMANENT REPAIRS MADE TO PORT MAIN ENG.VSL RPTD WHITE EXHAUST SMOKE AND OVERHEATING. REPAIRS TO INCLUDE NEW LINERSPISTONS & BEARINGS - TOP END OVERHAUL. SEA TRIALS SCHED APPROX 17JUL96
Condition: Unknown
Due 18 July 1996
Resolved 26 August 1996
Construction/Loadline
Issued 26 July 1994
Resolved
OWS not functioning properly. Repair and prove proper operation prior to its use.
Condition: Unknown
Due 26 August 1994
Resolved 9 August 1994
Engineering
Issued 8 September 1993
Resolved
MAKE PERMANENT REPAIRS TO PORT REDUCTION GEAR. VESSEL IS NOT ALLOWED TO CARRY PASSENGERS FOR HIRE UNTIL PERMANENT REPAIRS HAVE BEEN COMPLETED.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Accommodation/Occupational Safety
Issued 1 April 1993
Resolved
PROVIDE EMERGENCY EXIT SIGNS IN LOUNGE AREA FOR STATEROOMS IN THE AFT 400'SAND A EMERGENCY EXIT SIGN FOR ENGINE ROOM IN LOUNGE.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Accommodation/Occupational Safety
Issued 1 April 1993
Resolved
PROVIDE EMERGENCY EXIT SIGNS IN LOUNGE FOR STATE ROOMS IN THE AFT 400'S ANDA EMERGENCY EXIT SIGN FOR ENGINE ROOM IN LOUNGE.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Electrical
Issued 13 April 1990
Resolved
SHOW PROPER OPERATION OF 3 GENERATOR'S LOW LUBE OIL ALARMS/SHUTDOWNS
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Fire Fighting
Issued 13 April 1990
Resolved
INSTALL CO2 SIREN AND TIME DELAY IN ENGINE ROOM FIXED CO2 SYSTEM
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Documentation
Issued 13 April 1990
Resolved
PROVIDE VALID F.C.C. CERTIFICATE
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Documentation
Issued 13 April 1990
Resolved
SHOW PROOF OF ANNUAL SURVEY OF LOADLINE
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Lifesaving
Issued 13 April 1990
Resolved
PROPERLY INDICATE BY LETTER E ALL EMERGENCY LIGHTING
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Engineering
Issued 13 April 1990
Resolved
SHOW PROPER OPERATION OF MAIN ENGINE LOW LUBE OIL AND HIGH JACKET WATER ALARM AND ALL APPROPRIATE MAIN ENGINE ALARMS LOCATED ON THE BRIDGE
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Construction/Loadline
Issued 13 April 1990
Resolved
PLUG ALL HOLES IN WATERTIGHT BULKHEAD BETWEEN ENGINE ROOM AND AFTER LAZERETTE
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Fire Fighting
Issued 13 April 1990
Resolved
INSTALL PROPER SIZE PIPING FOR FIXED CO2 SYSTEM BRANCH LINES WITHIN THE ENGINE ROOM
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990
Navigation
Issued 4 April 1989
Resolved
PROVIDE UPDATED DEVIATION TABLE.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989
Resolved
PROVIDE PLANS AND MAKE ALL FIRE SCREEN DOORS COMPLY WITH 46 CFR 72.05-25 (DOORS OTHER THAN WATER TIGHT).
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
BLANK OFF OR REPLACE OPEN BREAKERS IN DISTRIBUTION PANELS OUTSIDE GALLEY.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Engineering
Issued 4 April 1989
Resolved
PROVIDE ADEQUATE HEAT RESISTANT SIGHT GLASS IN ENGINE ROOM AND MECHANICAL PROTECTION AND SELF CLOSING VALVES FOR THIS ARRANGEMENT.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 15 October 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE ON AN OCEANS VOYAGE MORE THAN 20 MILES FROM LAND, PROVIDE FOR EACH LIFE PRESERVER ON BOARD A COAST GUARD APPROVED PFD LIGHT.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Engineering
Issued 3 December 1986
Resolved
REPAIR OR REPLACE REDUCTION GEAR OIL PRESSURE GAUGE ON PORT AND STBD MAIN ENGINE INDICATOR PANEL LOCATED ABOVE MAINS.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Engineering
Issued 3 December 1986
Resolved
REPAIR OR REPLACE ENGINE OIL TEMPERATURE GAUGE ON PORT MAIN INDICATOR PANEL.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Electrical
Issued 25 October 1986
Resolved
REPAIR LOOSE JUNCTION BOX ON THE OMNI-PURE UNIT IN LAZERETTE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
INSTALL BELT GUARD ON CENTER GENERATOR WATER PUMP DRIVE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
REPLACE MISSING LIGHT GUARD IN LAZERETTE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
REPAIR SOLENOID SHUTOFFS ON E/R CENTER GENERATOR AND EMERGENCY GENERATOR.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
REPAIR TACHOMETERS ON PORT AND CENTER GENERATORS.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Accommodation/Occupational Safety
Issued 25 October 1986
Resolved
RENEW OR BENCH TEST RELIEF VALVES ON HOT WATER HEATERS IN LAZERETTE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
RENEW OR REPAIR AMP METER TO EMERGENCY GENERATOR
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
RENEW DRIP TRAY ON PORT GENERATOR RACOR FUEL FILTER.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Navigation
Issued 25 October 1986
Resolved
MAKE PERMANENT REPAIRS TO FATHOMETER ON BRIDGE ( DIGITAL FATHOMETER STBD SIDE)
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Electrical
Issued 25 October 1986
Resolved
REPLACE MISSING COVER TO FLOURESENT LIGHT IN A/C ROOM.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Fire Fighting
Issued 30 October 1985
Resolved
PROCURE ONE (1) HAND OPERATED FIRE PUMP.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Navigation
Issued 30 October 1985
Resolved
STENCIL VESSEL NAME ON EPIRB.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Navigation
Issued 30 October 1985
Resolved
PROCURE TWELVE (12) PARACHUTE FLARES IN COMPLIANCE WITH SOLAS 1960 REQUIREMENTS. NOTE: THIS ITEM RESTRICTS VESSEL FROM INTERNATIONAL SERVICE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985
Resolved
REPAIR EXPOSED WIRES OF P/A SPEAKER ABOVE FLAMABLE LIQUID STORAGE ON FANTAIL BY USING U/L APPROVED PRESSURE CONNECTORS
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Accommodation/Occupational Safety
Issued 30 October 1985
Resolved
REPAIR DOG ON PORT AIR INTAKE VENT COVER ON FANTAIL.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Construction/Loadline
Issued 30 October 1985
Resolved
MAKE BILGE SPACE UNDERNEATH AFTER PASSENGER ACCOMADATION SPACES AVAILABLE FOR INSPECTION BY CG MARINE INSPECTOR.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Electrical
Issued 30 October 1985
Resolved
REATTACH BILGE ALARM ECLETRICAL CONNECTION BOX IN LAZARETTE.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Accommodation/Occupational Safety
Issued 30 October 1985
Resolved
INSTALL SAFETY LINE AROUND BOARDING LADDER ON FANTAIL.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Fire Fighting
Issued 30 October 1985
Resolved
AMMEND FIRE CONTROL PLAN TO ACCURATELY SHOW FIRESTATION LOCATIONS AND FIRE EXTINGUISHER LOCATIONS. NOTE: THIS ITEM RESTRICTS VESSEL FROM INTERNATIONAL VOYAGE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Fire Fighting
Issued 30 October 1985
Resolved
PROCURE TWO (2) FIREMANS OUTFITS AS DEFINED BY SOLAS 1960 REQUIREMENTS. NOTE: THIS ITEM RESTRICTS VESSEL FROM INTERNATIONAL VOYAGE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 30 October 1985
Resolved 30 October 1985
Fire Fighting
Issued 1 November 1984
Resolved
PROCURE OBA, LAMP, AND TENDING LINE FOR EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
REPAIR AND PROVE OPERATION OF STBD EMBARCATION LIGHT
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
PROCURE FIRE CONTROL PLAN
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
PROCURE HAND FIRE PUMP
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
SUBMIT PROPOSAL FOR ESCAPE TRUNKS FOR MID SECTION AND AFT LOWER ACCOMADATION SPACES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
INSTALL ESCAPE TRUNK FOR FWD LOWER CREW ACCOMADATION SPACE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
SUBMIT PROPOSAL FOR PROPER STORAGE OF FLAMABLE LIQUIDS IN ACCORDANCE WITH 46 CFR 177.10-5 AND 181.20-1[2]
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
LABEL ESCAPE HATCHES IN DINING ROOM AND FWD LOUNGE
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Accommodation/Occupational Safety
Issued 1 November 1984
Resolved
INSTALL GREESE VENT SCREENS TO RANGE HOOD IN GALLEY.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
INSTALL PROPER FUEL OIL HOSE TO STBD GENERATOR
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
INSTALL SIGN IN ENGINEROOM TO VACATE ENGINEROOM WHEN CO2 SIREN IS HEARED.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
SUBMIT INFORMATION AS TO NEW INSTALLED CARPET AND EXISTING DRAPES ARE FIRE RETARDANT.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
PROCURE 12 PARACHUTE FLARES
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Navigation
Issued 1 November 1984
Resolved
PROCURE 1 BELL
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
STENCIL EMERGENCY GEAR LOCKER,LIFERAFTS,AND AXES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
REPAIR OR REPLACE BRACKET FOR RING BOUY LIGHT, STBD SIDE FWD MAIN DECK.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
REPLACE BATTERY AND PROVE OPERATION OF SMOKE ALARM ON LOWER DECK BY CABIN 405.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
REPAIR OR REPLACE STEERING CABLE ON RESCUE BOAT AND PROVE OPERATION.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984