MAURY USCG vessel records Sign in
← All vessels

SEA LEOPARD

SEA LEOPARD is a 1979 industrial vessel. The Coast Guard has recorded 44 inspections since 1992, most recently in October 2010, along with 28 deficiencies and 1 casualty investigation in 2009.

Records from 1992 to 2010. Most recent: inspection, 26 October 2010.

Built
1979
Last inspected
26 October 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCB8537
Flag
UNITED STATES
366950320 (licence lapsed)
Maury page id
psix-50084

Inspections, by type

…with no type recorded12
Years with a record 19 calendar years (1992–2010)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Convention (Subpart B), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
328 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCB8537MMSI 366950320 · expired · compulsorily equipped · granted 19 September 2008, cancelled 1 December 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MIA MALOY Offshore Supply Vessel · MISLE 49856 · 25 January 1996 · activity 41212

Inspection history · 44

26 October 2010 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3878458
13 May 2009 MTSA Verification · Re-Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3473785
14 April 2009 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3452645
7 April 2009 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3443500
7 April 2009 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3447962
5 April 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3447966
19 June 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3241845
3 June 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3241798
1 May 2008 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3199867
10 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3181109
16 March 2007 MTSA/ISPS Verification · Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2889066
14 February 2007 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2872088
8 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2644099
19 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2638645
27 March 2006 Ballast Water Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2610247
18 April 2005 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2333735
26 March 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2031638
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972325
28 February 2003 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1750466
11 April 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1603552
29 March 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462941
7 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 56575
13 April 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464282
19 March 1999 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402817
19 February 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 12987
9 March 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786221
3 March 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381154
25 March 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385933
5 February 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437045
1 February 1996 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183704
26 January 1996 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191169
25 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41212
26 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880153
24 March 1995 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355188
31 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 675788
30 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 167252
16 June 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1019387
28 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356614
23 July 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151303
12 July 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154617
18 June 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1135202
12 May 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467377
22 September 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932325
13 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949806

Deficiency record · 28

Construction/Loadline › Hull › Bottom Plating
Issued 7 April 2009 Resolved
Bottom plate contains tear measuring 1" X 10" below #2 cargo tank. tear is not fully penetrating tank and tank is dry at this time. Vsl is to proceed to Conrad S/Y in Amelia, LA to affect repairs and to contact [name withheld] to attend vsl. Vsl is to transit during daytime hours only.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 17 April 2009
Resolution: Repairs sat. Drydock exam completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 April 2008 Resolved
Replace / Renew lagging on port mde exhaust.
Action required: 705 - Other - as specified
Due 10 May 2008
Resolved 11 April 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 April 2008 Resolved
Repair stbd remote fuel shutoff valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2008
Fire Fighting › Fire Pumps › Power Source
Issued 10 April 2008 Resolved
Repair / Renew contact switch for fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2008
Fire Fighting › Fire Pumps › Gland Sealing
Issued 6 April 2007 Resolved
Fire pump seal was leaking excessively. Replace firepump seal to the satisfaction of the attending coast Guard inspector.
Action required: 705 - Other - as specified
Resolved 10 April 2007
Resolution: Fire pump seal was replaced and pump was run with adequate pressure supplied at hose nozzles.
Stability › Watertight Integrity › General
Issued 16 March 2007 Resolved
Watertight door from machinery space to engineroom would not seal. Adjustments to door must be made to ensure watertight integrity.
Action required: 705 - Other - as specified
Resolved 10 April 2007
Resolution: Adjustments were made to watertight door and dawgs. Watertight door seals correctly now.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2007 Resolved
Areas of wastage on main deck plate, port and stbd stack spaces, cargo deck numerous areas, at transom and at cabin. gagings required on all areas suspect. all areas of wastage to be replaced per NVIC 6-78.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 10 April 2007
Resolution: Vessel went through full hull inspection. Areas of wastage were cropped and renewed.
Construction/Loadline › Hull
Issued 26 March 2004 Resolved
Hull plating rotted in vicinity of #5 stern void. Plating is wasted above generator keel cooler. Unauthorized doubler was welded in place to repair, but leak expanded due to severe wastage. Vessel headed to shipyard to effect proper repairs. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 31 March 2004
Resolution: Repairs completed at Bollinger Shipyard to the satisfaction of attending Marine Inspector.
Stability › Watertight Integrity
Issued 28 February 2003 Resolved
Conduct effective repairs to the bulkhead deck under both port and starboard enginee exhaust stack truck. Bulkhead deck was cut open for personnel access to the ventilation motors and the bulkhead deck was never inserted.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2003
Resolved 28 March 2003
Resolution: CG Inspector witnessed effective repairs to exhaust stack trunk.
Pollution Prevention/Response › Prevention Equipment
Issued 11 April 2002 Resolved
PRIOR TO SAILING PROPERLY CLEAN ALL BILGES, REMOVING ALL OILY WASTE LEGACY COMPONENT DESC: BILGES
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 11 April 2002
Engineering › Fuel Oil Service System
Issued 11 April 2002 Resolved
INSTALL CHAFING GEAR ON ALL FUEL OIL HOSES
Condition: Improper Installation
Due 11 April 2002
Resolved 11 April 2002
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 11 April 2002 Resolved
DOUBLE NUT SHAFT PACKING
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 11 April 2002
Construction/Loadline › Structures › Door
Issued 11 April 2002 Resolved
PROPERLY ADJUST ALL WATERTIGHT DOORS BELOW THE MAIN DECK.
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 11 April 2002
Engineering › Fuel Oil Service System › Filter
Issued 11 April 2002 Resolved
INSTALL PLUGS IN ALL FUEL FILTER FLAME BOWLS.
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 11 April 2002
Electrical › Electrical Distribution System (service)
Issued 11 April 2002 Resolved
REMOVE DEAD END WIRING AT THE STEERING PUMPS. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 11 April 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 11 April 2002 Resolved
PROPERLY STENCIL AUX FLAT WATERTIGHT DOOR. LEGACY COMPONENT DESC: STENCILLING
Due 11 April 2002
Resolved 11 April 2002
Pollution Prevention/Response › Prevention Equipment
Issued 11 April 2002 Resolved
PROPERLY STENCIL PRESSURE TEST DATE FOR FUEL OIL TRANSFER HOSE. LEGACY COMPONENT DESC: FUEL HOSE
Condition: Placed in Improper Service
Due 11 April 2002
Resolved 11 April 2002
Accommodation/Occupational Safety
Issued 19 March 1999 Resolved
PROVIDE ADEQUATE SIZE RELIEF VALVE FOR FORWARD AIR RECEIVER.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Navigation
Issued 19 March 1999 Resolved
REPAIR LOOSE STEERING GEAR RAMS TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 19 April 1999
Resolved 30 March 1999
Documentation
Issued 19 March 1999 Resolved
PROVIDE ASME U-1A MANUFACTURERE'S REPORT FOR FORWARD AIR RECEIVER._x001C_
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 19 March 1999 Resolved
DEMONSTRATE COMPLIANCE WITH EIGHTH COAST GUARD DISTRICT POLICY LETTER DATED12NOV98, "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS," TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Deck/Cargo
Issued 9 March 1998 Resolved
Provide installation report and weight/load test for crane prior to operations.
Condition: Unknown
Due 10 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998 Resolved
DEMONSTRATE PROPER OPERATION OF RECUE BOAT DAVIT.
Condition: Unknown
Due 9 March 1998
Resolved 11 March 1998
Construction/Loadline
Issued 25 March 1997 Resolved
INSTALL WATERTIGHT DOOR ON 01 DECK TO ACCOMMODATION ENTRANCE
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 26 January 1996 Resolved
PERMIT TO PROCEED FOR REPAIRS ONLY. TRANSIT ROUTE TO BE CONFIRMED WITH CHIEF OF INSPECTIONS (MSO MORGAN CITY) PRIOR TO VESSEL MOVEMENT.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Documentation
Issued 24 March 1995 Resolved
OWNER IS TO PROVIDE ONBOARD NEW STABILITY DATA AND LETTER BASED ON INCLINE DONE 21MAR95 AT BOLLINGER SHIPYARD LOCKPORT, LA.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Documentation
Issued 28 April 1994 Resolved
PROVIDE ON BOARD A F.C.C. RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Documentation
Issued 12 May 1993 Resolved
PROVIDE ONBOARD VALID FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993

Casualty record · 1

5 April 2009Routine · role: Involved in a Marine Casualty · activity 3447966
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record