MAURY USCG vessel records
← All vessels

CAPT T LE

CAPT T LE is a 1979 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2016, most recently in May 2026, along with 44 deficiencies, 1 operational control and 4 casualty investigations between 2005 and 2011.

Records from 2005 to 2026. Most recent: inspection, 29 May 2026.

Built
1979
Last inspected
29 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8982553
WDC9568
Flag
UNITED STATES
Maury page id
psix-50085

Documentation record

Registered dimensions (L × B × D)94.5 ft × 25.2 ft × 7.1 ft
Registered tonnagegross 99 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC. · PATTERSON, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

29 May 2026 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8383017
11 March 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8087298
20 November 2024 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7851214
12 March 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867880
20 March 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7636188
3 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7631870
27 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613877
21 November 2022 Examination of Repairs · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7585027
2 March 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7403586
28 June 2021 Examination of Repairs
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7240420
12 May 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7166539
14 January 2021 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7120466
12 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7110827
8 December 2020 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7108360
8 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7108590
3 June 2020 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6933938
8 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6655103
29 November 2018 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6578205
10 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6369187
8 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6303587
6 March 2017 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6081976
27 October 2016 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6031513
9 March 2016 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5825903

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 March 2025 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Fwd bilge suction piping after manifold was wasted. Replaced wasted piping and provide SAT test to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2025
Resolution: Vessel replaced suction piping elbow and strainer. Reported test Sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 November 2024 Resolved
Make repairs to crack in upper middle portion starboard deck rail. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 November 2024
Resolution: Received picture proof of rectification.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 November 2024 Resolved
Make repairs to wasted deck weld on port quarter freeing port stanchion. 46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 22 November 2024
Resolution: Received picture proof of rectification.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 November 2024 Resolved
Make repairs to cracked starboard bow chock. 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 November 2024
Resolution: Received picture proof of rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 November 2024 Resolved
Fill bulkhead wire penetrations located WT Bulkhead # 2, port side adjacent to salon head. 46 CFR 179.320
Action required: 10 - Deficiency Rectified
Resolved 20 November 2024
Resolution: Corrected during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 March 2024 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust gas was present during port generator operation in the lazarette space. Remove exhaust lagging, identify piping leak and submit repair proposal. Port generator is restricted to emergency use only until leak is repaired. Vessel is to draft safety plan for entry into space for crew awareness to include use of atmospheric testing and air changes until repair is completed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 28 March 2024
Resolution: Lazarette exhaust piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Port forward bit showed weld failure in the deck inboard deck area. Submit repair proposal and complete repairs NLT 2024 dry dock to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 April 2024
Resolved 20 November 2024
Resolution: Provided repair plan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Starboard cargo deck rail has a crack in the upper middle portion. Submit repair proposal and complete repairs NLT 2024 dry dock to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2024
Resolved 20 November 2024
Resolution: Provided repair plan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. The port quarter 2nd freeing port stanchion from the stern is wasted at the deck weld. Submit repair proposal and complete repairs NLT 2024 dry dock to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2024
Resolved 20 November 2024
Resolution: Provided repair plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2024 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Remove all combustible waste receptacles and replace with non-combustible type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 28 March 2024
Resolution: Replaced with non-combustible metal waste receptacles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2024 Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. All (5) fuel strainer assemblies on board were missing plugs or caps. Install plug or cap assembly for each strainer.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 28 March 2024
Resolution: Plugs provided for all fuel strainers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 12 March 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Stbd bow chock was completely damaged beyond use with a crack in bulwark. Damage looked to be localized to bulwark chock. Submit repair proposal and complete repairs NLT 2024 dry dock to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 20 November 2024
Resolution: Provided repair plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2024 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck, or, if it is readily accessible under service conditions, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead. Reach rod was stuck and not operable on initial test. Vessel exercised and greased on site with SAT test from weather deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 March 2024
Resolution: Valve maintenance was conducted on site with SAT test results.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 March 2024 Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. Waring device was not working for Port main diesel engine exhaust. Vessel replaced flow alarm on site with SAT alarm test from operating station.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 12 March 2024
Resolution: Vessel replaced flow switch.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 March 2023 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of 46 CFR. Waterlight had weak strobe. Replace battery/or repair as per manufacturer requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 3 April 2023
Resolution: Floating waterlight strobe satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Retroreflective marking was wasted on numerous lifejackets. Make lifejackets in compliance to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 3 April 2023
Resolution: Retroreflective marking on lifejackets in compliance to the satisfaction of attending Marine Inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 March 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel's testing devices were expired. Until such time that valid testing devices are available onboard, vessel representative has stated that obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Vessel will need to replace testing devices as required and or show written policy attesting to how the vessel will obtain the devices and conduct the required alcohol tests within 2 hours from the time of occurrence of the SMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 7 March 2022
Resolution: Vessel replaced testing devices as required.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 2 March 2022 Resolved
When a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Vessel did not have stability letter posted. Post stability letter as required per regulation and to the satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Posted stability letter as required per regulation and to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel's charts were not updated. Provide current/corrected charts for operational areas. Vessel has paper charts, but utilizes electronic charts while navigating. Electronic charts are from May 2009. Provide proof of up-to date electronic charts unless vessel intends to use paper charts for navigation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 16 March 2022
Resolution: Provided proof of up-to date electronic charts for navigation.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 2 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables; and Current tables. Vessel did not have electronic versions or hard copies of these publications. Electronic versions were kept on server that vessel did not have access to due to poor wireless connection. If vessel intends to use electronic versions of these publications they must be downloaded for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Downloaded electronic versions of required publications.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 2 March 2022 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Rudder stops had large gap at hard over (port & starboard). Make rudder stops as required as per regulation and to the satisfaction of attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 15 April 2022
Resolution: Made rudder stops as required as per regulation and to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 March 2022 Resolved
In a vessel of 12 meters or more in length but less than 50 meters in length, A sidelight must be visible for 2 miles. Port sidelight was not illuminating. Make port sidelight illuminate as per regulation and to satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Made port sidelight illuminate as per regulation and to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 March 2022 Resolved
A 40-B portable fire extinguisher installed outside the space may be substituted for a fixed gas fire extinguishing system in a paint locker, with a volume of not more than 200 cubic feet. portable fire extinguisher discharge hose permanently affixed to port leading through paint locker bulkhead. Port inside paint locker was blocked with debris that could impede effectiveness of extinguishing agent. Clear area around extinguisher discharge port and keep clear at all times to the satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Cleared area around extinguisher discharge port to the satisfaction of attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2022 Resolved
Each Class 1 door on a vessel must be designed to withstand a head of water equivalent to the depth from the sill of the door to the margin line but in no case less than 10 feet. Vessel was not prepared to test watertightness. Test in accordance with ASTM F 1196. Another effective watertight test is the “chalk test.” Rub chalk on the knife edge of the door frame and close the door securely. It should leave a continuous chalk impression on the door gasket. If it is not continuous, the door requires adjustment or the frame requires replacement. Conduct testing in accordance with ASTM F 1196 or a chalk test and send results to attending Marine Inspector with Master attesting to completion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 16 March 2022
Resolution: Conduct a satisfactory chalk test.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 June 2021 Resolved
Provide a repair proposal for the starboard side #3 frame that is fractured.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2021
Resolved 20 July 2021
Resolution: Proper repairs were completed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 May 2021 Resolved
Public address speakers on aft deck inoperable. Speakers not installed in galley and lower passenger areas. Demonstrate proper operation of public address system in all spaces accessible to passengers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 21 May 2021
Resolution: Vessel installed speakers below decks and repaired exterior speakers.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 12 May 2021 Resolved
Safety orientation not being conducted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 May 2021
Resolved 12 May 2021
Resolution: Crew provided verbal safety orientation during inspection. Company representative to address fleetwide.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2021 Resolved
Monthly portable fire extinguisher checks not being conducted or logged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 May 2021
Resolved 12 May 2021
Resolution: Vessel representative provided inspection tags and crew will use them to document inspections.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2021 Resolved
Switchboard hertz meter inoperable. Demonstrate proepr operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 21 May 2021
Resolution: Vessel rpelaced herz meter and demonstrated operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2021 Resolved
Pressure gauge on starboard air receiver not reading accurately. Replace and demonstrate proper operation of relief valve.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 21 May 2021
Resolution: Vessel replaced pressure gauge and relief valve then demonstrated operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2020 Resolved
Vessel is required to complete a hull exam every 2 yerars. Vessel is overdue for hull exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2021
Resolution: Vessel completed sea trails.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 April 2018 Resolved
Make fire dampers seal better with gasket materials and additional securing devices.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 23 April 2018
Resolution: Dampers seal were corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 March 2017 Resolved
Complete hydro testing of portable CO2 fire extinguisher for paint locker, or replace bottle with currently serviced unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 22 March 2017
Resolution: CO2 bottle was hydroed and stamped.
Construction/Loadline › Structures › Scuttle
Issued 6 March 2017 Resolved
Make emergency escape hatch for forward salon operable; passengers restricted to main deck untl operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 22 March 2017
Resolution: Escape hatch working properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2017 Resolved
Replace corroded wire from battery, stbd side gen compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 22 March 2017
Resolution: Wire replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 March 2017 Resolved
Provide crew training on rescue sling/block & tackle assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 22 March 2017
Resolution: Crew training completed and documented.
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2016 Resolved
Clad weld isolated pit in E/R just aft of hydraulic tank.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 10 November 2016
Resolution: Clad weld completed sat.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 7 November 2016 Resolved
Repair/replace leaking valve on sight glass for lube oil tank.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 10 November 2016
Resolution: New valve installed.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 November 2016 Resolved
Ventilate laz for inspection.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 10 November 2016
Resolution: Laz ventilated for inspection.
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2016 Resolved
Clad weld isolated pit just inboard of stbd rudder.
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 10 November 2016
Resolution: Clad weld completed sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 November 2016 Resolved
Repair support bracket for port exhaust line in laz.
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 10 November 2016
Resolution: Bracket repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 October 2016 Resolved
Complete credit drydock exam prior to carrying passengers after 31OCT16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2016
Resolved 10 November 2016
Resolution: Drydock exam completed
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 March 2016 Resolved
Repair exhaust leak: starboard piping in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 March 2016
Engineering › Bilge Water Management System › Valve
Issued 9 March 2016 Resolved
Repair forepeak remote bilge valve closure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 25 March 2016

Casualty record · 4

12 July 2005Routine · role: Involved in a Marine Casualty · activity 2427052
2 October 2008Routine · role: Sighted in Area · serious marine incident, as classified · 2 dead · activity 3337650
26 November 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3369758
7 June 2011Routine · role: Involved in a Marine Casualty · activity 4073290
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PRICE TIDE (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.