MAURY USCG vessel records
← All vessels

COASTAL STAR

Built
1978
Last inspected
10 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN6241
Flag
UNITED STATES
Maury page id
psix-50092

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE, LA, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portROCKPORT, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M/V CONSTELLATION Unclassified · MISLE 108429 · 2 February 2024 · activity 7860689

Inspection history · 20

10 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8109687
3 April 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8104747
4 April 2024 Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7890031
3 February 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7862266
2 February 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7860689
20 April 2023 Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7672600
27 December 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7613570
11 April 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7428608
15 November 2021 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7351049
8 March 2021 Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7152244
1 March 2021 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7148441
16 September 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7059338
14 September 2020 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7058140
3 September 2019 In-Service Inspection · Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6802292
29 April 2019 In-Service Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6672779
24 May 2018 Deficiency Check · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6421612
10 May 2017 COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6143366
10 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6121409
29 August 2016 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5986222
11 March 2016 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5831467

Deficiency record · 10

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 April 2025 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Neither of the two VHF radios on board were connected to the GPS nor programmed with MMSI number. Rectify to the satisfaction of the attending marine inspector. 46CFR184.502 47CFR80.905(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: VHF radio connected to GPS and MMSI number was programmed in.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel charts were not up to date. Rectify to the satisfaction of the attending marine inspector. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: Verified charts updated 24April2025.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 April 2025 Resolved
At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous conditions be corrected. The vessel has a cracked window on the port side of the passenger accommodation. Rectify to the satisfaction of the attending marine inspector. 46CFR176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: Verified window was replaced 24APR2025.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 April 2024 Resolved
An internal structural examination conducted in compliance with 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessels fuel tanks. Found a crack at the top corner of the fuel tank. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 18 April 2024
Resolution: Received objective evidence from the vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024 Resolved
All cabling must be installed with metal supports spaced not more than (24 inches) apart. Found cabling that was spaced more than 24 inches apart. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2024
Resolved 18 April 2024
Resolution: Received objective evidence from the vessel rep.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 November 2021 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has exceeded the 3 month window for its annual inspection. Vessel must complete an annual inspection prior to departure, prior to operations, and prior to the carriage of passengers/cargo to the satisfaction of the attending Marine Inspector. 46 CFR 176.500(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2021
Resolution: Completed satisfactory Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 September 2020 Resolved
Annual inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is not authorized to carry cargo or passengers until COI annual is completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 24 September 2020
Resolution: Completed Annual inspection.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 24 May 2018 Resolved
A VESSEL ON LAKES, BAYS, AND SOUNDS, OR RIVERS MUST CARRY THREE RED FLARE DISTRESS SIGNALS AND THREE HAND ORANGE SMOKE DISTRESS SIGNALS. A HAND RED FLARE DISTRESS SIGNAL MAY BE SUBSTITUTED FOR HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL HAS SIX HAND RED FLARE DISTRESS SIGNALS OF WHICH FOUR WERE EXPIRED.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2018
Resolved 31 May 2018
Resolution: Vessel owner replaced all expired flares.
Engineering › Bilge Water Management System › Valve
Issued 15 May 2017 Resolved
Fore peak submersible bilge pump discharge without positive shutoff valve at hull penetration. A positive shutoff valve must be installed at the hull penetration. Vessel restricted from operating until valve installed.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 May 2017
Resolution: Vessel rep installed a positive action shutoff valve on the spot prior to vessel movement(drills).
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 March 2016 Resolved
Certificate of Documentation expired Nov. 30, 2015. Per VDOC, an application for renewal has not been submitted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 18 March 2016
Resolution: Provided copy of COD and attending MI verified validity in MISLE.

Ownership record