LYNDA ANN

LYNDA ANN is a 1979 offshore supply vessel. The Coast Guard has recorded 57 inspections since 1981, most recently in July 2025, along with 63 deficiencies, 1 operational control and 3 casualty investigations between 2005 and 2008.

Records from 1981 to 2025. Most recent: inspection, 11 July 2025.

Built
1979
Last inspected
11 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4744
Flag
UNITED STATES
367701520
Maury page id
psix-50168

Inspections, by type

…with no type recorded15
Years with a record 37 calendar years (1981–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)83.5 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 October 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4744MMSI 367701520 · active · compulsorily equipped · granted 21 November 2025, expires 7 November 2035
WDC6763MMSI 367060950 · expired · compulsorily equipped · granted 6 August 2005, cancelled 10 October 2015
WCV3965MMSI 338033000 · cancelled · compulsorily equipped · granted 29 April 1998, cancelled 8 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KELLIE L FEDKOE Towing Vessel · MISLE 94262 · 30 April 2008 · activity 3413367

Inspection history · 57

11 July 2025 COI Inspection · Internal Structural Exam · Deficiency Check · Vessel Attendance · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8157054
6 December 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7834594
28 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7636177
14 September 2021 Drydock Exam · Annual Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7323646
22 February 2021 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7144228
22 October 2019 Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6830452
25 October 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6562689
4 August 2017 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226149
24 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6028436
12 August 2016 Annual Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5962720
10 November 2015 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5757051
22 October 2014 Internal Structural Exam · Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5005738
22 September 2010 Examination of Repairs · Drydock Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3854813
18 August 2008 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3305616
1 May 2008 Damage Survey · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3196269
30 April 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3413367
16 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3201845
17 October 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2802245
23 August 2006 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2757604
9 May 2005 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798432
24 March 2005 Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2318337
15 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2319234
27 August 2004 Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2153539
18 September 2003 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1907609
16 September 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1905982
2 August 2002 COI Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1653748
23 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7935
29 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815575
26 May 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802395
12 March 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464827
23 February 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378377
10 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778330
20 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448911
22 March 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441058
14 March 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449797
14 March 1994 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1166210
16 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366793
18 February 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1010956
8 April 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917225
10 November 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932656
25 June 1990 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 913302
16 April 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211352
2 August 1989 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1335357
24 February 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888306
1 August 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342950
6 October 1987 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1328970
30 April 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985200
30 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308812
5 November 1985 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296536
10 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982395
2 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978445
2 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284531
19 March 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284984
10 March 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279026
15 March 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276293
12 March 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965824
7 April 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968191

Deficiency record · 63

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2025 Resolved
The two required fixed power bilge pumps shall be self-priming and shall each be driven by different sources of power. If one pump is driven off the main engine in a single propulsion engine installation, the other shall be independently driven. Found bilge pump to not be self primming. 46CFR182.25-10(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 December 2025
Resolved 22 December 2025
Resolution: Check valve was installed in the wrong direction, valve was installed correctly, system operated sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 December 2025 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. Found aft escape hatch in engine room inoperable. 46CFR177.15-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 December 2025
Resolved 22 December 2025
Resolution: The securing wheel shaft was removed and straightened allowing for proper operation. WTD test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 17 December 2025 Resolved
The setting of safety valves or relief valves on boilers and unfired pressure vessels shall be checked. Observed relief valve pop at 165PSI and then the valve did not re seat once pressure was relieved. 46CFR176.25-30(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 December 2025
Resolved 22 December 2025
Resolution: Owner procured and installed new SRVs.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 17 December 2025 Resolved
The minimum number of portable fire extinguishers required on each vessel shall be as determined in accordance with Table 181.30-1(a). Vessel was missing 1 40B extinguisher. 46CFR181.30(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 17 December 2025
Resolved 22 December 2025
Resolution: Owner procured 01 40B extinguisher, installed.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 17 December 2025 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. 46 CFR 185.410(b)
Action required: 705 - Other - as specified
Due 17 March 2026
Resolved 12 March 2026
Resolution: Installed FURUNO BNWAS BR-570.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 February 2023 Resolved
Gauges to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines. Port M/E cooling water gauge and RPM gauge is inoperable, Vsl has operable Stbd gauges. 46 cfr 182-15-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vsl submitted proof of functional tachometer for both engines.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2023 Resolved
Interconnected detection and alarm system. (a) An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); 46 cfr 181.450
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 21 April 2023
Resolution: Vessel installed 7 hard-wired interconnected fire detectors that all alarm when one detector alarms.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 February 2023 Resolved
Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. 01 portable fire extinguisher was found without sufficient extinguishing agent. Replace inoperable extinguisher with proper extinguisher. 46 cfr 176.810 a (1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vsl submitted proof of replaced/serviced portable extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock and shall minimize accidental personnel contact with energized parts. Opening in distribution panel missing a cover. Cover opening to protect against contact. 46 CFR 183.200 (b)&(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 14 March 2023
Resolution: Vsl covered opening of spare breaker in distribtion panel
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 January 2022 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The Marine Inspector (MI) observed the Call Sign listed on the FCC Safery Certificate did not match the one listed on the Station License. Provide updated FCC documents. CITE: 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Updated FCC documents provided.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 January 2022 Resolved
A card of instructions giving a clear summary of the radiotelephone distress procedure must be securely mounted and displayed in full view of the principal operating position. The MI observed the Call Sign on the Emergency Broadcast Placard does not match the FCC Station License. Update Placard. Cite: 47 CFR 80.868
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Photo of updated Emergency Broadcast Placard provided.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 3 January 2022 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. The MI observed there was not a Garbage Management Plan onboard. Cite: 33 CFR 151.57
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Photos of Garbage Management Plan onboard provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 January 2022 Resolved
All marine employers must submit drug testing program data required by 49 CFR 40.26 and appendix H to 49 CFR part 40. The MI observed the Drug and Alcohol Program was not onboard to include details about the submission of Management Information System data. Cite: 46 CFR 16.500
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Proof of drug consortium letter and last tests onboard provided.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 January 2022 Resolved
The master or person in charge of a ship, including a drilling rig or platform, to which this section applies shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. The MI observed the MARPOL placards were an out dated version. Cite: 33 CFR 151.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: MARPOL placards replaced with new placards.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 3 January 2022 Resolved
All GMDSS equipment capable of transmitting an automatic distress alert which includes position of the ship must have either an integral navigation receiver or capability of being connected to an external navigation receiver. If an external navigation receiver is installed, it shall be connected to all of the alerting devices referred to in paragraph (a) of this section. The MI observed the GPS coordinates were not showing in the VHF DCS data. Cite: 47 CFR 80.1085 (c )
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: GPS coordinates entered into the VHF DCS data.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 January 2022 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. The MI observed the foam in one of the Ring Life Buoys is not functioning as designed. Replace in kind. Cite: 46 CFR 180.70 (a) (3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: New Ring Life Buoy to replace old one.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 January 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The MI observed the date on the sticker needs to be replaced to match the last inspection certificate. Cite: 46 CFR 180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: EPIRB certification date is current.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 January 2022 Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The MI observed the gage is not of an adequate range. Cite: 46 CFR 54.15-5 (f)
Action required: 10 - Deficiency Rectified
Due 1 February 2022
Resolved 1 February 2022
Resolution: Proper gage installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 January 2022 Resolved
At each intial and subsequent inspection for certification, reinspection and at every other vessel inspection the MI shall require that all observed unsafe practices and hazardous situations be corrected. The MI observed the relief valve on the water heater was not piped to below the bilge to protect crew. Cite: 46 CFR 176.25-50 (a) [Old T]
Action required: 10 - Deficiency Rectified
Due 1 February 2022
Resolved 1 February 2022
Resolution: Relief valve on the water heater piped to below the bilge to protect crew.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 January 2022 Resolved
All escape hatches and emergency exits shall be marked on both sides using 1" letters; "Emergency Exit. Keep Clear". The MI observed the emergency exit from the engine room was not marked. Cite: 46 CFR 185.30-15 (a) [Old T]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Emergency exit from the engine room properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 January 2022 Resolved
Each generator, motor and other major items of power equipment shall be provided with a name plate indicating the maker's name, its rating in volts and amperes or in volts and watts and when intended for connection to a normally grounded supply, the grounding polarity. The MI observed both generators need new name plates. Cite: 46 CFR 183.05-5 (a) [Old T]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2022
Resolved 31 January 2022
Resolution: Provided pictures of new data plates on both generators with 50 degrees celcius rating.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 March 2021 Resolved
No public address(PA) system found functioning for the below deck crew accommodations. Install fixed PA system to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2021
Resolved 15 March 2021
Resolution: MI witnessed a satisfactory testing of the crew accommodation PA system.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 1 March 2021 Resolved
EPIRB was found with a expired hydrostatic release unit. Replace with new EPIRB hydro static release unit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2021
Resolved 15 March 2021
Resolution: Expired EPIRB was replaced with a new item. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2021 Resolved
Vessel's Alcohol testing strips were found expired. Replace with new testing strips IAW drug and alcoholic program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2021
Resolved 15 March 2021
Resolution: MI verified operator replaced the expired alcohol testing strips with 6 new items. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2021 Resolved
Bottom stowed life float was found with dry rotted pendants. Recondition life float or replace with a approved one.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2021
Resolved 15 March 2021
Resolution: MI verified damaged life float was replaced with another suitable life float meeting USCG requirements and conditions.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 March 2021 Resolved
Replace expired aspirins in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 15 March 2021
Resolution: vsl operator replaced existing first aid kit with a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 October 2018 Resolved
Watertight doors and the E/R escape hatch has soft foam gaskets. Replace with proper watertight rubber gaskets and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 30 October 2018
Resolution: Watertight gaskets doors and E/R escape hatch replaced with proper gasket and tested
Engineering › Fuel Oil Service System › Hose
Issued 29 August 2016 Resolved
Replace identified fuel hoses on main engine.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 August 2016 Resolved
Repipe temp relief valve on hot water tank into bilge.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 August 2016 Resolved
Close openings and label distribution panels throughout the vessel.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 August 2016 Resolved
Replace gasket on paint locker.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 29 August 2016 Resolved
Repair sight glass on lube oil tank.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 29 August 2016 Resolved
Repair filter for clothes dryer.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Electrical › Electric Generation Source (service) › Generator
Issued 29 August 2016 Resolved
Clean windings on both generators (dust).
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Engineering › Fuel Oil Service System › Hose
Issued 29 August 2016 Resolved
Place chaffing gear on all hose/engine contacts.
Due 29 September 2016
Resolved 12 September 2016
Resolution: Received email with attached picture attesting to satisfactory corrective action.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 November 2015 Resolved
Vessel does not currently hold a valid COD. Provide valide COD onboard to the satisfaction of attending CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2015
Resolved 13 November 2015
Resolution: New owners applied for COD.
Stability › Watertight Integrity › General
Issued 10 November 2015 Resolved
Bulkhead penetrations in the FWD bulkhead of the engine room on port side at the base of the stairs are not watertight. Prove watertight integrity to attending CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2015
Resolved 12 November 2015
Resolution: All penetrations properly sealed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 November 2015 Resolved
Both ships service generators and workshop bench grinder to not have guards around rotating components. Provide guards to the satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 24 November 2015
Resolved 12 November 2015
Resolution: Proper guards installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 November 2015 Resolved
Remote fuel oil shutoff was not labeled. Crew labeled and corrected on the spot.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Crew stenciled fuel shutoff valves with paint.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 10 November 2015 Resolved
#2 F/O vent did not contain a flame screen. Corrected on the spot.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Crew installed correct flame screen on fuel vent. Corrected on the spot.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 30 October 2014 Resolved
M/I found inoperative starboard generator. Prove proper operation of the stbd generator prior to returning to service. To be cleared by the attending marine inspector.
Action required: 705 - Other - as specified
Due 30 October 2014
Resolved 4 November 2014
Resolution: Observed proper start up and operation of the vessels starboard generator. Found satisfactory by the attending marine inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 30 October 2014 Resolved
M/I found inoperative emergency light in the engine room. Make repairs and prove proper operation to the attending marine inspector.
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 4 November 2014
Resolution: Observed as satisfactory by the attending marine inspector.
Stability › Unintentional Flooding › General
Issued 22 September 2010 Resolved
When Fire Monitor Pump is operating, it leaks into the bilge. Packing needs to be addressed to prevent leakage. Vessel is restricted from using Fire Montior until leak is addressed.
Due 8 November 2011
Resolved 11 October 2012
Resolution: Fire Monitor was satisfactorily tested during COI exam on 06Aug12.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 September 2010 Resolved
Sight Glasses on Fuel tanks in E/R need to be glass, not plastic in case of fire.
Due 30 October 2010
Resolved 17 November 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2008 Resolved
Vessel has several dead ended cables in E/R. Cables shall be removed.
Due 3 October 2008
Resolved 3 October 2008
Resolution: All dead ended cables were removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 August 2008 Resolved
Exhaust lagging was loose and not attached properly. Attach lagging correctly to piping.
Due 3 October 2008
Resolved 3 October 2008
Resolution: Lagging correctly reinstalled.
Stability › Watertight Integrity › General
Issued 18 August 2008 Resolved
A/C drain drains directly into e/r bilge. Vessel shall pipe drain pipe into vessel for discharge overboard.
Due 3 October 2008
Resolved 3 October 2008
Resolution: Drain pipe repiped to drain into vessel for collection to be discharged overboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 1 May 2008 Resolved
Vessel was missing two B II fire extinguishers required on the COI.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2008
Resolution: Extinguishers replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 May 2008 Resolved
All smoke detectors were not working and batteries were missing. 46 CFR 176.810 (a) 7.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2008
Resolution: All smoke detectors were replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 17 March 2005 Resolved
Vessel was hard aground. A requirement was issued as follows "Do not operate vessel in commercial service until a Coast Guard Inspection has been conducted. Notify the [name withheld] Detail [phone withheld] when the vessel arrives at a drydock facility."
Action required: 705 - Other - as specified
Resolved 24 March 2005
Resolution: A damage/repair survey was conducted. The vessel is fit for route and service.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 18 September 2003 Resolved
Provide proof of hydrostatic test of installed CO2 cylinder for engine room IAW 46 CFR 147.65. LEGACY COMPONENT DESC: Hydrostatic Date
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 27 August 2004
Resolution: Witnessed satisfactory CO2 inspection.
Communications › Radio Communications
Issued 16 September 2003 Resolved
The SSB radio was not able to transmit on 2182 KHZ. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Unknown
Due 16 October 2003
Resolved 18 September 2003
Resolution: Witnessed satisfactory test.
Lifesaving › Liferaft Equipment
Issued 16 September 2003 Resolved
Provide two new lifefloat paddles, stenciled with vessel name and lashed to the lifefloat webbling with a breakable line. LEGACY COMPONENT DESC: Paddle
Condition: Damaged By Earlier Event
Due 16 October 2003
Resolved 18 September 2003
Resolution: Two new lifefloat paddles were provided and stenciled with the vessel''s name and lashed with breakable line.
Lifesaving › Liferaft Equipment
Issued 16 September 2003 Resolved
Tie all lifefloat paddles to the lifefloat webbing with a breakable line. LEGACY COMPONENT DESC: Paddle
Condition: Improper Installation
Due 16 October 2003
Resolved 18 September 2003
Resolution: All lifefloat paddles were tied to the lifefloat webbing with a breakable line.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 September 2003 Resolved
Install a bunk light above the appropriate rack in the main deck accomodation space.
Condition: Improper/Lack of Maintenance
Due 16 October 2003
Resolved 18 September 2003
Resolution: A bunk light was installed above the rack.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 16 September 2003 Resolved
Make hot water available from the sink faucet in the main deck head. LEGACY COMPONENT DESC: Hot and Cold Running Water
Condition: Improper/Lack of Maintenance
Due 16 October 2003
Resolved 18 September 2003
Resolution: Hot water was made available.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 September 2003 Resolved
Replace two sections of flooring, one just aft of the galley and the second, the wooden grate at the entrance to the engine room. LEGACY COMPONENT DESC: Open Deck Space
Condition: Damaged By Earlier Event
Due 16 October 2003
Resolved 18 September 2003
Resolution: The two sections of flooring were replaced.
Deck/Cargo › Holds/Tanks
Issued 16 September 2003 Resolved
Replace flame screens in the #2 and #3 fuel tank vents. LEGACY COMPONENT DESC: Flame Arrester
Condition: Improper/Lack of Maintenance
Due 16 October 2003
Resolved 18 September 2003
Resolution: New flame screen were installed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 September 2003 Resolved
Replace engine foot block on port main engine, inboard side aft. The existing block is cracked. LEGACY COMPONENT DESC: Block
Condition: Damaged By Earlier Event
Due 16 October 2003
Resolved 18 September 2003
Resolution: The engine foot block was replaced.
Construction/Loadline
Issued 12 March 1999 Resolved
Provide vent closures for main deck supply vents to engine room.
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Lifesaving
Issued 12 March 1999 Resolved
Provide on board suitable rescue platform.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Unknown
Issued 2 November 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, LAURIE G, DN603651
Condition: Unknown
Due 2 November 1984
Resolved 2 November 1984
Documentation
Issued 2 November 1984 Resolved
PROVIDE A VALID FCC SAFETY CERTIFICATE NOT LATER THAN 03DEC84 NOTIFY CG MARINE INSPECTION OFFICE UPON RECEIPT OF ABOVE.
Condition: Unknown
Due 2 November 1984
Resolved 2 November 1984

Casualty record · 3

15 March 2005Routine · role: Involved in a Marine Casualty · activity 2319234
16 April 2008Routine · role: Involved in a Marine Casualty · activity 3201845
30 April 2008Routine · role: Involved in a Marine Casualty · activity 3413367
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.