WAHINE KOA is a 1999 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2016, most recently in May 2026, along with 84 deficiencies — 2 with no resolution recorded — and 13 casualty investigations between 2009 and 2026.

Records from 2009 to 2026. Most recent: inspection, 15 May 2026.

Built
1999
Last inspected
15 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM7053
502197
Flag
UNITED STATES
Maury page id
psix-502197

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded7
…past their stated due date2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)64.5 ft × 27.0 ft × 6.4 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKVICHAK MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HULA KAI Passenger (Inspected) · MISLE 47193 · 15 May 2026 · activity 8410608

Inspection history · 36

15 May 2026 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8374087
15 May 2026 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8410608
24 September 2025 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8236283
29 April 2025 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8113064
18 July 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7960620
16 July 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7959237
21 April 2023 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7627152
24 January 2023 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7622891
10 June 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7489150
29 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7357254
5 November 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362596
2 November 2021 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362176
15 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7313065
26 May 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7207913
29 September 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7067796
23 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842142
16 October 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6844119
11 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6835958
18 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6816792
3 September 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6807661
3 September 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862577
25 April 2019 Damage Survey · Deficiency Check · Hull Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6671243
22 April 2019 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668113
8 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6639047
2 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6636088
17 September 2018 DAPI Audit · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545781
13 June 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6443323
23 April 2018 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6396032
1 December 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6316057
20 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6311770
18 November 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6310549
30 October 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6050156
20 October 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6046872
4 July 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5930905
24 June 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6005347
5 May 2016 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867436

Deficiency record · 84

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2026 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. One of the vessel's main propellers was fouled by line. Demonstrate proper operation of the propeller and associated machinery to the satisfaction of the attending Marine Inspector. 46 CFR 176.700(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2026
Resolution: Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 October 2025 Resolved
A request for amended Certificate of Inspection must be made to the cognizant OCMI by the owner or managing operator of the vessel at any time there is a change in the character of a vessel or in its route, equipment, ownership, operation, or similar factors specified in its current Certificate of Inspection. Vessel moved from Kewalo Basin Harbor to Kaneohe Bay which is outside the permitted Routes and Conditions on the COI. 46 CFR 176.120(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Vessel relocated back to original route.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2025 Resolved
A catamaran vessel must be equipped with bilge pumps for each hull, as if each hull is a separate vessel, in accordance with Table 182.520(a). MI found starboard bilge pump to have insufficient dewatering capacity. Passenger count reduced to 49 until proper operation of bilge can be demonstrated to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 26 September 2025
Resolution: MI witnessed starboard bilge pump dewatering, fully operational. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2025 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. MI found 64 adult and 01 child life jackets require renewal/replacement of retroreflective material. Passenger count reduced to 88 until retroreflective type material is renewed/replaced to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 6 October 2025
Resolution: All life jackets have repaired/renewed retroreflective material. Vessel may carry 149 passengers as per COI. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2025 Resolved
Each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter. MI found 02 adult life jackets condemned on site due to degradation and 07 adult life jackets require repair. Passenger count reduced to 142 until life jackets are replaced/repaired to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 26 September 2025
Resolution: MI verified repairs of 07 adult life jackets with [name withheld] repair kit. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 September 2025 Resolved
Each survival craft required on a vessel by this part must meet one of the following… For a life float-Approved under approval series 160.027 or other standard specified by the Commandant. MI found 01 life float to deteriorated past good and serviceable condition. Passenger count reduced to 132 until replacement of life float to the satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 26 September 2025
Resolution: MI witnessed removal of 04 life floats. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 September 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situation must be correct. MI found inadequate lighting in port engine room. Repair installed lighting to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 26 September 2025
Resolution: MI verified adequate lighting in port engine room. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2025 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI found no log of EPIRB testing. Create log of EPIRB testing to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 15 October 2025
Resolution: EPIRB log for testing created and onboard. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 September 2025 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Create inspection and maintenance log for survival craft to be kept onboard to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 26 September 2025
Resolution: Vessel rep removed life floats. Maintenance log and instructions no longer required. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2025 Resolved
The owner, charter, master or managing operator shall instruct each crew member....at least once every three months, as to the duties that the crew member is expected to perform in an emergency...Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. MI found no log of required crew training or drills. Create log to document training and drills to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 15 October 2025
Resolution: Log book for crew training and drills created and onboard. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 September 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI found expired aspirin. Replace contents of first-aid kit to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2025
Resolved 15 October 2025
Resolution: Valid aspirin placed onboard. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's port engine and generator emergency fuel shutoff valves were not operable. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2024
Resolution: Repaired fuel shutoff valves to operational condition.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 July 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel was not prepared to conduct drills. 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2024
Resolution: Conducted satisfactory fire and abadon ship drills to the satisfaction of the attending MI.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 18 July 2024 Resolved
Each sewage retention device must have a means of indicating when the device is more than 3/4 full by volume. Vessel does not have means of determining when sewage tank is at 3/4 full. Provide usage policy to prevent overflow of sewage tank. 33 CFR 159.85
Action required: 705 - Other - as specified
Resolved 14 August 2024
Resolution: Retracted deficiency due to it not being applicable this vessels Type III marine sanition device. .
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 July 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces. Port 1, 3 and Stbd 1, 2, 3, and 4, bilge alarm light is not operational. Roving watch required to make rounds of spaces containing inoperable equipment every 30 minutes until rectified. 46 CFR 182.530 (a)
Action required: 705 - Other - as specified
Resolved 26 August 2024
Resolution: Witnessed operational test of all bilge high level alarms. Test found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2024 Resolved
On a vessel not more than 65 feet in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. Gauge at pump outlet less than 60 psi. 46 CFR 181.300 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 26 August 2024
Resolution: Witnessed operational test of fire pump. Gauge was reading over 60 psi. Test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 July 2024 Resolved
Each launching appliance and each survival craft must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Life floats onboard are deteriorated from UV radiation from the sun. 46 CFR 185.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 15 August 2024
Resolution: Received email with three photographs as evidence the life floats were repaired; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2024 Resolved
Electrical equipment used in the following locations must be drip proof: A machinery space. 100v outlets installed in engine room are not drip proof. 46 CFR 183.210 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 15 August 2024
Resolution: Received email from vesel rep with photograph of the new outlets drip proof covers; all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2024 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. In port tank space, bilge piping not properly secured to the vesel. 46 CFR 177.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 15 August 2024
Resolution: Received email from vessel rep with photogrpah of the port tank space bilge pipe secured; all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2024 Resolved
All fuel tanks must be electrically bonded to a common ground. Grounding wire for stbd fuel tank is corroded. 46 CFR 182.440(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 15 August 2024
Resolution: Received email from vessel rep with photograph of the fuel tank bonding wire connected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2024 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Coolant recovery tanks currently using a water bottle to catch overflow. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 26 August 2024
Resolution: Correct coolant recovery tanks installed on the main engines.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 July 2024 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Port rudder room submersible pump for nuisance water inoperable. 46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 24 October 2024
Resolution: Replaced and secured submersible pump to the deck.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 18 July 2024 Resolved
The design, installation and testing of each LPG system must meet ABYC A-1, Chapter 6 of NFPA 302, or other standard specified by the commandant. LPG regulator on gas grill corroded. No warning label posted on cooking equipment. 46 CFR 184.240(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 26 August 2024
Resolution: Regulator and propane tanks removed from grilling assembly. Grill has been taken out of service.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 July 2024 No resolution recorded
A vessel must comply with the structural design requirements of one of the standards listed. Wastage identified on port bilge manifold. Rectify at next drydock. 46 CFR 177.300
Action required: 705 - Other - as specified
Due 1 May 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 July 2024 No resolution recorded
A vessel must comply with the structural design requirements of one of the standards listed. Wastage identified on inboard side of port rudder room. Rectify at next drydock. 46 CFR 177.300
Action required: 705 - Other - as specified
Due 1 May 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 July 2024 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Wastage and possible cracking identified on stbd hull near engine room ventilation. Rectify at next drydock. 46 CFR 177.300
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 29 April 2025
Resolution: Inspected areas described, found no evidence of cracking.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2024 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel failed to undergo an annual inspection within the allowable time constraints. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2024
Resolution: Inspection completed 18 Jul 2024. Activity: 7960620
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 April 2023 Resolved
A vessel must comply with the structural design requirements of one of the listed standards. The inboard side aft bilge knuckle of the starboard lazzarette presented pitting in excess of 50% thickness. Crop and renew hull plating per verbal repair proposal. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 5 May 2023
Resolution: Wasted hull plating was cropped and inserted per verbal repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 21 April 2023 Resolved
A vessel must comply with the structural design requirements of the one of the listed standards. The transverse frame in way of the port rudder post presented signs of structural fatigue. Crop damaged section of the frame and insert per verbal repair proposal. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 5 May 2023
Resolution: The transverse frame was repaired per the verbal repair proposal.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 January 2023 Resolved
Fixed gas fire extinguishing systems are required to be serviced and inspected. Vessel required to provide satisfactory evidence of the required servicing. Fixed gas fire extinguishing systems have not been serviced within the last year. Provide satisfactory evidence of required servicing to attending marine inspector. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2023
Resolution: Received servicing records for fixed gas fire extinguishing systems.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2023 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's hand orange smoke distress signals are expired. Vessel has eight red hand flare distress signals and is required to have 4 hand orange smoke signals in order to meet the regulation. Vessel restricted to a Lakes/Bays/Sounds route. 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel rep provided proof of 12 red flares.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 24 January 2023 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Provide new HRUs for life floats. Vessel restricted to a Lakes/Bays/Sounds route. 46 CFR 185.740
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel Rep. provided new HRUs for life floats.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2023 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Anchor light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Rep provided proof of operable anchor light.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 January 2023 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. During operational test of fire pump, pressure gage at outlet reading 30 psi. Make 60 psi in presence of attending Marine Inspector. 46 CFR 181.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 24 February 2023
Resolution: Vessel rep provided video of fire pump gauge at 60 psi.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2023 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Aspirin in first aid kit expired. Renew aspirin. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 10 February 2023
Resolution: Vessel provided new asprin for first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 January 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel rep provided proof of new chart.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 January 2023 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the forward port electric bilge pump. Prove proper operation of the forward port side bilge pump. 46 CFR 182.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 1 March 2023
Resolution: Vessel owner demonstrated proper operation of electric and fixed bilge pumps in the forward port side bilge.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 January 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces The # 2 bilge pump visual indicator is inoperable. Prove proper operation of the required visual indicator. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 9 February 2023
Resolution: Vessel rep provided video evidence of the indicator operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 January 2023 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles missing vessel name. Mark life float paddle with vessels name. 46 CFR 185.604(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 9 February 2023
Resolution: Vessel rep provided photo of paddles with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 January 2023 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Life floats not separated with spacers. Provide spacers between life floats. 46 CFR 180.137 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 9 February 2023
Resolution: Vessel rep provided spacers between life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 January 2023 Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. 46 CFR 180.175(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel rep replaced floating waterlight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2023 Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrical hazards, including fire and electrical shock. Four dead ended wires are present in the helm console. Provide an immediate temporary repair of wire nuts and electrical tape on each wire end. Provide a proper repair by removing the dead end cables or properly terminating them. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 9 February 2023
Resolution: Vessel rep terminated dead end cables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 January 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Bow life jacket storage not label properly. Label storage to reflect number of adult and children life jackets are in place. 46 CFR 180.78 (a)(50)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel rep provided photograph of proper stowage and labeling of adult and child life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2023 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Surge protector installed above helm area. Remove surge protector, use provided outlets. 46 CFR 183.340(r)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Vessel owner removed surge protector and now using provided outlets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2023 Resolved
Each pressure type wire connector and lug must meet UL 486A (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration; and twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice or extending the length of a circuit. Port engine room has a exposed wire nut. Make a permanent type connection. 46 CFR 183.340(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 9 February 2023
Resolution: Vessel rep removed wire nut and made a permanent type connection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 January 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name on forward and aft main deck ring life buoy wasted. Renew vessel name on ring life buoy. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 26 January 2023
Resolution: Name clearly printed onto ring life buoy by vessel rep.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 January 2023 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. 46 CFR 185.520(f)
Action required: 10 - Deficiency Rectified
Due 24 January 2023
Resolved 24 January 2023
Resolution: Vessel rep logged drills conducted during COI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 January 2023 Resolved
The master of the vessel shall ensure that: Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator. Log test. 46 CFR 185.728
Action required: 10 - Deficiency Rectified
Due 24 January 2023
Resolved 24 January 2023
Resolution: Vessel rep tested EPIRB for attending MI and recorded it.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 December 2021 Resolved
Each life jacket and ring buoy must be marked in clearly legible block capital letters with the vessel's name. All life jackets currently have the previous vessel name. Provide proper marking and identification on all life jackets. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2021
Resolution: Life jackets properly marked.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 December 2021 Resolved
Wire, other than in switchboards, must meet the requirements in sections 24.6.7 and 24.8 of IEEE 45-2002, NPFC MIL-W-76D, UL 44, UL 83 (all four standards incorporated by reference; see 46 CFR 110.10-1), or equivalent standard. Found multiple non-marine grade wires. Remove or replace wires IAW with above regulation. 46 CFR 111.60-11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2021
Resolution: Unapproved wire replaced with approved boat cable of the appropriate guage.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 December 2021 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length, a battery powered bullhorn may serve as the public address system if audible throughout the accommodation spaces of the vessel during normal operating conditions. Vessel missing bullhorn. Re-install vessel's PA system, or acquire a bullhorn. 46 CFR 184.610(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2021
Resolution: A permanent PA system was provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 December 2021 Resolved
A Certificate of Documentation (COD) is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. Vessel Operator does not have new COD. Provide the COD with vessel's new name. 46 CFR 67.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 January 2022
Resolution: NVDC issued a new, updated, correct COD for the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 20 December 2021 Resolved
Each vessel must (1) Have permanent draft marks at each end of the vessel; or, (2) Have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel does not have loading marks. Add loading marks during next drydock. 46 CFR 185.602(c)
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: Verified presence of loading marks.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 November 2021 Resolved
A vessel on which a pre-engineered fixed gas fire extinguisher system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Operator was able to restart both main engines without engaging override function during auto shutdown test of Fireboy system. 46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2021
Resolution: Tested Fireboy and engines. Both working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2021 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. A stop-check valve located at a control point or manifold will meet the requirements for both a stop valve and a check valve. No check valves or stop-check valves installed on bilge line. Provide proper valve arrangement prior to next credit dry dock. 46 CFR 182.510(c)
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: Check valves in the bilge lines were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all supervisory personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 30 November 2021
Resolution: Supervisors completed required EAP Training.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 September 2021 Resolved
As appropriate for intended voyage a vessel must carry updated CG Light List. Light list out dated. Provide current light list. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 8 October 2021
Resolution: Light list provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2021 Resolved
Each life jacket must be marked clearly with the vessels name. New life jackets missing marking. Provide vessel name on all life jackets. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 8 October 2021
Resolution: Lifejackets marked.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 15 September 2021 Resolved
The name of the vessel must be marked on each life float paddle. Life float paddles missing vessel name. Provide proper marking on paddles. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 6 October 2021
Resolution: Names provided on paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 15 September 2021 Resolved
Each life float must be marked with retro-reflective tape. Provide new retro tape for life floats. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 11 October 2021
Resolution: Retro tape provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2021 Resolved
Visual alarm must be at the operating station to indicate a high water level. Space S2 did not have a functioning visual alarm. Provide visual alarm for high water for S2 space at operating station. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 16 September 2021
Resolution: Light replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021 Resolved
Max number of passengers on an upper deck must be indicated at the entranceway to the deck. Signage missing indicating max passengers allowed. Provide sign. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 14 October 2021
Resolution: Sign provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2021 Resolved
Unused fire fighting components still onboard vessel. Remove all associated CO2 piping and signage. Pull handles at galley still say CO2. Piping and sirens located in engine room. 46 CFR 181.120
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 14 October 2021
Resolution: CO2 piping removed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 September 2021 Resolved
Door sill/threshold cut out from forward door leading to exterior seating. Provide documentation stating USCG approved this change or bring back to original condition. 46 CFR 179.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 5 November 2021
Resolution: Door sill welded into place.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. No auto bilge pump have visual indication. Provide visual indication at operating station. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 10 November 2021
Resolution: Visual indicators operational.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 September 2021 Resolved
Sewage system must be secured in a manner that prevents the discharge of sewage. No padlock on valve. Provide padlock on valve in closed position or remove valve handle in closed position. 33 CFR 159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 8 October 2021
Resolution: Sewage overboard handle removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 September 2020 Resolved
Visual high water bilge alarm for compartment starboard 4 did not work. Provide visual indicator for S4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2020
Resolution: New light installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 September 2020 Resolved
Numerous extension cords and surge protectors located under helm. Remove extension cords and surge protectors. Make electrical wiring conform to approved electrical drawings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: Cords removed and electricla drawings submitted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 29 September 2020 Resolved
Sewage overboard not locked. Provide lock for sewage overboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: Valve handles removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2020 Resolved
Starboard engine room CO2 bottle showing heavy rust at retaining band/strap. CO2 bottle cannot visually pass inspection. The bottle is condemned. Provide fire extinguishing capabilities for starboard engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2020
Resolution: New fire boy system installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2020 Resolved
Fire fighting pump does not have PSI gauge. Provide gauge at fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2020
Resolved 29 October 2020
Resolution: New gauge installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 September 2020 Resolved
Pitting shown in hull at numerous areas throughout vessel. Submit/provide drawing where all pitting is located and crop and renew at next drydock.
Action required: 705 - Other - as specified
Resolved 21 June 2021
Resolution: Drydock completed. All repairs made.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 October 2019 Resolved
Port and stbd engine compartment CO2 bottles and heat activation pilot cylinders were not weighed during annual maintenance. Complete annual maintenance in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 23 October 2019
Resolution: CO2 bottles and pilot cylinders were weighed. Weights were within tolerance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2019 Resolved
CO2 fixed extinguishing system did not secure port generator during test. Prove system secures generator when activated in accordance with 46 CFR 181.410.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 11 October 2019
Resolution: Port generator secured during test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2019 Resolved
Port CO2 time delay was 10 seconds and stbd time delay was 13 seconds when tested. Both time delays are marked 30 seconds. Renew time delays in accordance with 46 CFR 181.410.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 11 October 2019
Resolution: Port and stbd time delays functioned correctly. Stbd 36 seconds. Port 31 seconds.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 September 2019 Resolved
Stbd bilge pump failed to dewater test space. Prove correct operation in accordance with 46 CFR 176.804. Vessel limited to 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 September 2019
Resolution: Video provided showing satisfactory operation of pump. Matt with Pacwhale maintenance stated he changed impeller and tightened engine driven belt.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 September 2019 Resolved
3 lifefloats outer coverings exposed to sun were faded. Repair or renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 23 October 2019
Resolution: Satisfactory life floats provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 September 2019 Resolved
Stbd tank room bilge lines have epoxy patches where dissimilar metal clamps made contact with pipe. Renew piping in accordance with 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 11 October 2019
Resolution: Stbd bilge lines containing epoxy patches were renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2019 Resolved
Port and stbd aft engine room watertight bulkheads had unsealed penetration in outboard upper corners. Seal penetrations in accordance with 46 CFR 176.802.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 11 October 2019
Resolution: Bulkheads sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 April 2019 Resolved
The vessel suffered a 18 inch long seam crack in its under wing metal allowing for water intrusion. . Submit repair proposal to Sector Honolulu in accordance with 46 CFR 176.700. Repair prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2019
Resolution: Area cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2019 Resolved
Maintain operation of machinery. Vessel port shaft sheared at reduction gear coupling. Repair and prove operation on accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2019
Resolution: Shaft replaced. Seatrial observed.
Construction/Loadline › Hull › Keel Plate
Issued 23 April 2018 Resolved
Submit repair proposal for STBD #1 compartment frame 3-4 keel area under bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2018
Resolution: Repair proposal was submitted and approved. Witnessed Successful NDT for welds.
Fire Fighting › Fire Main › Condition
Issued 20 November 2017 Resolved
Epoxy patches in fire main port engine room. Repaur/renew in accordance with 46CFR 181.310.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 1 December 2017
Resolution: Firemain repaired.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 October 2016 Resolved
Port aft lifejacket storage is infested with roaches. Clean and remove all lifejackets and exterminate roaches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2016
Resolved 21 October 2016
Resolution: Vessel cleaned all jackets and space. Also had exterminator come spray the storage locker and the rest of the vessel.

Casualty record · 13

19 June 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3620168
29 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3712377
13 August 2013Routine · role: Involved in a Marine Casualty · activity 4719076
22 October 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4739447
23 December 2013Routine · role: Acknowledged Pollution Source · activity 4774820
30 December 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5045986
24 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6005347
4 July 2016Routine · role: Involved in a Marine Casualty · activity 5930905
30 October 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6050156
18 November 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6310549
16 October 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6844119
5 November 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7362596
15 May 2026Routine · role: Involved in a Marine Casualty · 1 injured · activity 8410608
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

OCEAN QUEST (2009–2017), OCEAN QUEST ADVENTURES (2019–2021). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.