01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2025
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. You must submit your written application for renewal of a Certificate of Inspection (COI) to the OCMI at least 30 days prior to the expiration date of the COI, as required in 176.105 of this part. Vessel is overdue for drydock examination date and COI is coming due 29JUL2025. Complete a drydocking to the satisfaction of a Coast Guard Marine Inspector and new COI immediately after drydocking.
46 CFR 176.600(c)(1)
46 CFR 176.404(b)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2024
Resolved
Retro-reflective material required by this section must be Type I material that is approved under subpart 164.018 of this chapter. 32 Life preservers had inadequate retro-reflective tape affixed. Vessel is restricted to carrying no more than 96 passengers until retro-reflective tape is replaced, to the satisfaction of the attending Marine Inspector. 46 CFR 180.25-25(b) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 18 September 2024
Resolution: Retroreflective was placed on lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 September 2024
Resolved
The ring life buoy shall have attached to it a line at least 60 feet in length. The ring life buoy line was 50 feet. Provide a 60 foot line, to the satisfaction of the attending Marine Inspector. 46 CFR 180.30-10(b) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 19 September 2024
Resolution: Appropriate line placed on lifering.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2024
Resolved
All vessels must have operable navigation lights in
accordance with the Navigation Rules. Stern light was
inoperable. Repair or replace stern light, to the
satisfaction of the attending Marine Inspector.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 18 September 2024
Resolution: Stern light replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 September 2024
Resolved
EAP training program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Provide an attendance roster for the required training signed/dated by company crew members, supervisory personnel, and DER to the satisfaction of the attending Marine Inspector. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 19 September 2024
Resolution: Vessel provided proof of EAP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2023
Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes. The grounded and ungrounded connectors for the macerater pump were spliced outside of a junction box. Properly enclose the splices in a junction box.
46 CFR 183.05-50 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: Splice enclosed into a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2023
Resolved
Propulsion machinery shall be suitable and capable of not exceeding its design limitations. The front main seal presented leakage. Repair the oil leak.
46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: Front seal leak corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2022
Resolved
Vessels at least 26' in length are required an audible and visual alarm at the operating station indicating high water levels in normally unmanned spaces containing through hull penetrations below the deepest loaded water line. The high water alarm in the starboard head compartment is inoperable. Prove proper operation of the high bilge water alarm in the starboard head compartment. While passengers are on board or have access to the vessel an additional crew member shall be required and will be required to make regular rounds of the starboard head compartment.
46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 25 October 2022
Resolved 14 October 2022
Resolution: Bilge high level alarm in the starboard head compartment proven operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 October 2022
Resolved
Equipment and materials not covered by the standards in this subchapter may be inspected in accordance with the standards acceptable to OCMI as good marine practice. The emergency escape in the port hull was difficult to open due to no handle being provided. Provide a handle to make access to the emergency escape easier.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 14 October 2022
Resolution: A handle aiding access to the emergency escape was provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 October 2022
Resolved
Hatches exposed to the weather on vessel's operating protected waters may be weathertight. The port and starboard engine forward engine room hatch gaskets are deteriorated. Replace gaskets.
46 CFR 178.35-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 14 October 2022
Resolution: The gaskets on the forward hatches in both engine rooms were replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 October 2022
Resolved
In general, compliance with structural standards established by a recognized classification society will be considered satisfactory for structural adequacy of a vessel. The wood coaming around the forward hatch to the starboard engine room is separating from main hull structure and shows evidence of water saturation. Remove and replace at next dry dock.
46 CFR 177.10-1
Action required: 705 - Other - as specified
Resolved 25 October 2022
Resolution: The rotten portion of the hatch frame was removed and replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 October 2022
Resolved
All vessels shall be fitted with ground tackle and hawsers as deemed necessary my the [name withheld] of the cleats the vessel is equipped with are wasted. Remove and replace at next dry dock.
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: The wasted cleats were removed and replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2021
Resolved
A vessel of not more than 19.8 meters (65 feet) in length must have a collision bulkhead if it: (1) Carries more than 49 passengers. Vessel has 4'x4' gaps in both collision bulkheads. Fill in gaps with in-kind planking.
46 CFR 179.210 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: The 4' x 4' inspection hatches were reinstalled and properly sealed closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2021
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to drain STBD amidships compartment with fixed bilge system due to weak suction. Repair fixed bilge suction to properly drain the space.
46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: Bilge system was satisfactorily tested.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 August 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The majority of contents in the first aid kit were expired. Replace expired contents.
46 CFR 184.710(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: A new first aid kit was provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 August 2021
Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. Master's medical credential was expired. Provide proof that medical status is current.
46 CFR 15.515 (c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 1 September 2021
Resolution: The master was able to provide sufficient evidence that his medical card was current and that a duplicate had been applied for.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2021
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drills were not be appropriately logged. Corrected on scene.
46 CFR 185.524 (d)
Action required: 10 - Deficiency Rectified
Resolved 19 August 2021
Resolution: Vessel began logging drills correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Stbd main engine has significant oil leak from front end.
46CFR182.100
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 14 July 2021
Resolution: Conducted operational test of starboard main engine, and no oil leak was observed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessels drydock inspection due 31 January 2020 and has not been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2021
Resolved 24 June 2021
Resolution: Drydock completed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 September 2019
Resolved
Port pre-engineered fixed gas fire extinguishing system does not shut down the generator in port engine compartment. A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 27 September 2019
Resolution: Both port generator and main engine shutdown as designed when Fireboy fixed firefighting system was engaged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Port main engine did not shutdown when the shutdown switch was engaged. All engines must have at least two means for stopping the engine(s) under any operating conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 27 September 2019
Resolution: Port engine shutdown switch worked as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2019
Resolved
Vessel ring lifebuoy not marked with vessel name and retro-reflective tape. Properly mark ring lifebuoy with vessels name and with retro-reflective tape in accordance with 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New ring buoy with required retro-reflective tapes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2019
Resolved
Hand portable bilge pump was not operational. Provide operational portable hand bilge pump in accordance with 46 CFR 182.520(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2019
Resolved 27 September 2019
Resolution: Bilge pump tested satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 July 2019
Resolved
Port porthole in forward toilet is not watertight. All openings in the side of a vessel below the bulkhead or weatherdeck shall be watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Window is sealed to be watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 31 July 2019
Resolved
Replace broken lightbulb and cover in wetsuit locker. Each lighting fixture must comply with 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New light bulb cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 July 2019
Resolved
The port main diesel engine exhaust piping is pitted and has been temporarily repaired with an epoxy like substance. Repair or replace the exhaust piping to the satisfaction of the attending USCG Marine Inspector. Pipes used for wet exhaust lines must be schedule 80 or corrosion resistant material and adequately protected
from mechanical damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New exhaust hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 July 2019
Resolved
The port diesel generator fuel supply non-metallic hose is secured with plastic zip ties and the port main diesel engine exhaust non-metallic hose is missing a hose clamp. In systems and applications where flexible hoses are permitted to be clamped.... the clamps must be of a corrosion resistant metallic material and two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Two hose clamps installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 July 2019
Resolved
The port diesel generator fuel return line is not secured and is chaffing against metal components in the engine room. Secure the fuel piping in accordance with the standards detailed in 46 CFR 182. 455 (b) (3) and install chaffing gear to prevent against further fuel line damage. Fuel lines must be accessible, protected from mechanical injury, and effectively secured again excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Fuel return line secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2019
Resolved
There is a ground conductor laying in the bilge in front of the port main diesel engine. Reattach the grounding conductor to its appropriate securing location. On a nonmetallic vessel, the enclosures & frames of electric
equipment must be bonded together to a common ground by a normally non-current carry conductor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Grounding wire reattached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2019
Resolved
The battery located about the port diesel generator has conductors secured to the battery terminals with wing nuts. Replace the wing nuts with permanent type connectors. Connections must be made to the battery terminals with permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Battery posts properly secured with compression nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 31 July 2019
Resolved
The port engine room ladder is temporarily secured with rope. Permanently secure the port engine room ladder with metallic hardware. The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous spaces, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Ladder secured properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2019
Resolved
Port and Starboard Engine room spaces protected by fixed fire extinguishing system allowed for free communication with both port/starboard engine rooms thru transverse tunnel and not found vapor tight. Make engine room vapor tight to ensure that the quantity of the extinguisher.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Engine bulkheads made vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 January 2019
Resolved
CONDUCTORS IN POWER AND LIGHTING CIRCUITS MUST BE NO. 14 AMERICAN WIRE GAUGE OR LARGER. WELDING CABLE WAS PRESENT IN MACHINERY ROOM. REPLACE WELDING CABLE WITH NO.14 AMERICAN WIRE GAUGE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2019
Resolution: Welding cable replaced with marine grade cable.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 January 2019
Resolved
WOOD FOUND IN CROSS DECK SHOWED EVIDENCE OF TERMITE DAMAGE. REPAIR DAMAGED CROSS DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2019
Resolution: Cross deck renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2018
Resolved
An adult lifejacket must be provided for each person carried on board. 11 faulty life jackets found on board. Replace faulty life jackets. Adult passenger count is reduced to 121 until replacements are onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 18 July 2018
Resolution: Vessel rep emailed picture of new replacement lifejackets onboard.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 July 2017
Resolved
Replace unserviceable child life vest. Child passenger count is reduced to 13 until replacement is onboard. 46CFR180.71
Condition: Improper/Lack of Maintenance
Due 25 August 2017
Resolved 10 August 2017
Resolution: Replaced child life vest with new approved life vest.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 July 2017
Resolved
Provide suitable markings for child life vest. 46CFR180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided suitable markings as evidenced by photograph.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 26 July 2017
Resolved
Provide/post emergency instruction list. 46CFR185.510
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided/posted emergency instruction list as evidenced by photograph.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 26 July 2017
Resolved
Provide/post waste management plan. 33CFR151.57
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided/posted waste management plan as evidenced by photograph.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 July 2017
Resolved
Post employee assistance program for drug abuse prevention hotline numbers in a common space. 46CFR16.401
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Posted employee assistance program for drug abuse prevention hotline numbers in a common space as evidenced by photograph.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 26 July 2017
Resolved
Provide 1 additional portable light so that at least 2 are onboard and at operating station and at access to propulsion machinery space. 46CFR183.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided 1 additional portable light as evidenced by photograph.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 June 2016
Resolved
01 Child and 05 Adult Life Jackets Unserviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new PFDs.
Lifesaving › Lifebuoys › Serviceable
Issued 17 June 2016
Resolved
Ring Buoy faded and line is deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new ring buoy.
Navigation › Piloting/Steering › Marine Charts
Issued 17 June 2016
Resolved
Nautical charts outdated.
Due 17 July 2016
Resolved 8 July 2016
Resolution: Vessel Rep provided reciepts for purchase of marine charts.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 June 2016
Resolved
Portable Fire Extinguishers expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new extinghuisher.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 June 2016
Resolved
Operating instructions not posted at operating station and in space
Due 17 July 2016
Resolved 17 July 2016
Resolution: vessel provided proof of resolution.
Communications › Public Address System › Loudspeaker
Issued 17 June 2016
Resolved
No PA system installed, required to procure battery powered bull horn.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided reciept of purchase.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 June 2016
Resolved
Anchor deteriorated.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided reciept of purchase.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 June 2016
Resolved
Deck rail on stern gangway missing life lines.
Due 24 June 2016
Resolved 24 July 2016
Resolution: Vessel provided photographic evidence of resolution.
Construction/Loadline › Structures › Deck Plating
Issued 17 June 2016
Resolved
Stern swim platform not secured properly.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 17 June 2016
Resolved
STBD fuel tank vent line not properly secured to the fuel tank.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Tank
Issued 17 June 2016
Resolved
Fuel tank bonding wire not secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 June 2016
Resolved
Flexible cooling hose collapsed.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 June 2016
Resolved
Guard on STBD engine fire pump not functional/deteriorated.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2016
Resolved
STBD engine battery box cover missing.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2016
Resolved
Port Side generator battery not properly mounted/secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Cable
Issued 17 June 2016
Resolved
Exposed power wires on port engine alternator.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 June 2016
Resolved
Engine Tachometer guage at control station inoperable.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2016
Resolved
Remove unused/exposed wiring.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Hose
Issued 17 June 2016
Resolved
Reroute port side generator fuel line, laying across deck/not secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.