Records from 1985 to 2026. Most recent: inspection, 15 May 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2025
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. You must submit your written application for renewal of a Certificate of Inspection (COI) to the OCMI at least 30 days prior to the expiration date of the COI, as required in 176.105 of this part. Vessel is overdue for drydock examination date and COI is coming due 29JUL2025. Complete a drydocking to the satisfaction of a Coast Guard Marine Inspector and new COI immediately after drydocking.
46 CFR 176.600(c)(1)
46 CFR 176.404(b)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2024
Resolved
Retro-reflective material required by this section must be Type I material that is approved under subpart 164.018 of this chapter. 32 Life preservers had inadequate retro-reflective tape affixed. Vessel is restricted to carrying no more than 96 passengers until retro-reflective tape is replaced, to the satisfaction of the attending Marine Inspector. 46 CFR 180.25-25(b) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 18 September 2024
Resolution: Retroreflective was placed on lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 September 2024
Resolved
The ring life buoy shall have attached to it a line at least 60 feet in length. The ring life buoy line was 50 feet. Provide a 60 foot line, to the satisfaction of the attending Marine Inspector. 46 CFR 180.30-10(b) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 19 September 2024
Resolution: Appropriate line placed on lifering.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2024
Resolved
All vessels must have operable navigation lights in
accordance with the Navigation Rules. Stern light was
inoperable. Repair or replace stern light, to the
satisfaction of the attending Marine Inspector.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 18 September 2024
Resolution: Stern light replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 September 2024
Resolved
EAP training program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Provide an attendance roster for the required training signed/dated by company crew members, supervisory personnel, and DER to the satisfaction of the attending Marine Inspector. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2024
Resolved 19 September 2024
Resolution: Vessel provided proof of EAP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2023
Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes. The grounded and ungrounded connectors for the macerater pump were spliced outside of a junction box. Properly enclose the splices in a junction box.
46 CFR 183.05-50 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: Splice enclosed into a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2023
Resolved
Propulsion machinery shall be suitable and capable of not exceeding its design limitations. The front main seal presented leakage. Repair the oil leak.
46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: Front seal leak corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2022
Resolved
Vessels at least 26' in length are required an audible and visual alarm at the operating station indicating high water levels in normally unmanned spaces containing through hull penetrations below the deepest loaded water line. The high water alarm in the starboard head compartment is inoperable. Prove proper operation of the high bilge water alarm in the starboard head compartment. While passengers are on board or have access to the vessel an additional crew member shall be required and will be required to make regular rounds of the starboard head compartment.
46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 25 October 2022
Resolved 14 October 2022
Resolution: Bilge high level alarm in the starboard head compartment proven operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 October 2022
Resolved
Equipment and materials not covered by the standards in this subchapter may be inspected in accordance with the standards acceptable to OCMI as good marine practice. The emergency escape in the port hull was difficult to open due to no handle being provided. Provide a handle to make access to the emergency escape easier.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 14 October 2022
Resolution: A handle aiding access to the emergency escape was provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 October 2022
Resolved
Hatches exposed to the weather on vessel's operating protected waters may be weathertight. The port and starboard engine forward engine room hatch gaskets are deteriorated. Replace gaskets.
46 CFR 178.35-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 14 October 2022
Resolution: The gaskets on the forward hatches in both engine rooms were replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 October 2022
Resolved
In general, compliance with structural standards established by a recognized classification society will be considered satisfactory for structural adequacy of a vessel. The wood coaming around the forward hatch to the starboard engine room is separating from main hull structure and shows evidence of water saturation. Remove and replace at next dry dock.
46 CFR 177.10-1
Action required: 705 - Other - as specified
Resolved 25 October 2022
Resolution: The rotten portion of the hatch frame was removed and replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 October 2022
Resolved
All vessels shall be fitted with ground tackle and hawsers as deemed necessary my the [name withheld] of the cleats the vessel is equipped with are wasted. Remove and replace at next dry dock.
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: The wasted cleats were removed and replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2021
Resolved
A vessel of not more than 19.8 meters (65 feet) in length must have a collision bulkhead if it: (1) Carries more than 49 passengers. Vessel has 4'x4' gaps in both collision bulkheads. Fill in gaps with in-kind planking.
46 CFR 179.210 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: The 4' x 4' inspection hatches were reinstalled and properly sealed closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2021
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to drain STBD amidships compartment with fixed bilge system due to weak suction. Repair fixed bilge suction to properly drain the space.
46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: Bilge system was satisfactorily tested.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 August 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The majority of contents in the first aid kit were expired. Replace expired contents.
46 CFR 184.710(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 1 September 2021
Resolution: A new first aid kit was provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 August 2021
Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. Master's medical credential was expired. Provide proof that medical status is current.
46 CFR 15.515 (c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2021
Resolved 1 September 2021
Resolution: The master was able to provide sufficient evidence that his medical card was current and that a duplicate had been applied for.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2021
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drills were not be appropriately logged. Corrected on scene.
46 CFR 185.524 (d)
Action required: 10 - Deficiency Rectified
Resolved 19 August 2021
Resolution: Vessel began logging drills correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Stbd main engine has significant oil leak from front end.
46CFR182.100
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 14 July 2021
Resolution: Conducted operational test of starboard main engine, and no oil leak was observed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessels drydock inspection due 31 January 2020 and has not been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2021
Resolved 24 June 2021
Resolution: Drydock completed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 September 2019
Resolved
Port pre-engineered fixed gas fire extinguishing system does not shut down the generator in port engine compartment. A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 27 September 2019
Resolution: Both port generator and main engine shutdown as designed when Fireboy fixed firefighting system was engaged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Port main engine did not shutdown when the shutdown switch was engaged. All engines must have at least two means for stopping the engine(s) under any operating conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2019
Resolved 27 September 2019
Resolution: Port engine shutdown switch worked as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2019
Resolved
Vessel ring lifebuoy not marked with vessel name and retro-reflective tape. Properly mark ring lifebuoy with vessels name and with retro-reflective tape in accordance with 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New ring buoy with required retro-reflective tapes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2019
Resolved
Hand portable bilge pump was not operational. Provide operational portable hand bilge pump in accordance with 46 CFR 182.520(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2019
Resolved 27 September 2019
Resolution: Bilge pump tested satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 July 2019
Resolved
Port porthole in forward toilet is not watertight. All openings in the side of a vessel below the bulkhead or weatherdeck shall be watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Window is sealed to be watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 31 July 2019
Resolved
Replace broken lightbulb and cover in wetsuit locker. Each lighting fixture must comply with 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New light bulb cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 July 2019
Resolved
The port main diesel engine exhaust piping is pitted and has been temporarily repaired with an epoxy like substance. Repair or replace the exhaust piping to the satisfaction of the attending USCG Marine Inspector. Pipes used for wet exhaust lines must be schedule 80 or corrosion resistant material and adequately protected
from mechanical damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: New exhaust hose installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 July 2019
Resolved
The port diesel generator fuel supply non-metallic hose is secured with plastic zip ties and the port main diesel engine exhaust non-metallic hose is missing a hose clamp. In systems and applications where flexible hoses are permitted to be clamped.... the clamps must be of a corrosion resistant metallic material and two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Two hose clamps installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 July 2019
Resolved
The port diesel generator fuel return line is not secured and is chaffing against metal components in the engine room. Secure the fuel piping in accordance with the standards detailed in 46 CFR 182. 455 (b) (3) and install chaffing gear to prevent against further fuel line damage. Fuel lines must be accessible, protected from mechanical injury, and effectively secured again excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Fuel return line secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2019
Resolved
There is a ground conductor laying in the bilge in front of the port main diesel engine. Reattach the grounding conductor to its appropriate securing location. On a nonmetallic vessel, the enclosures & frames of electric
equipment must be bonded together to a common ground by a normally non-current carry conductor.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Grounding wire reattached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2019
Resolved
The battery located about the port diesel generator has conductors secured to the battery terminals with wing nuts. Replace the wing nuts with permanent type connectors. Connections must be made to the battery terminals with permanent type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Battery posts properly secured with compression nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 31 July 2019
Resolved
The port engine room ladder is temporarily secured with rope. Permanently secure the port engine room ladder with metallic hardware. The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous spaces, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Ladder secured properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2019
Resolved
Port and Starboard Engine room spaces protected by fixed fire extinguishing system allowed for free communication with both port/starboard engine rooms thru transverse tunnel and not found vapor tight. Make engine room vapor tight to ensure that the quantity of the extinguisher.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2019
Resolved 11 September 2019
Resolution: Engine bulkheads made vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 January 2019
Resolved
CONDUCTORS IN POWER AND LIGHTING CIRCUITS MUST BE NO. 14 AMERICAN WIRE GAUGE OR LARGER. WELDING CABLE WAS PRESENT IN MACHINERY ROOM. REPLACE WELDING CABLE WITH NO.14 AMERICAN WIRE GAUGE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2019
Resolution: Welding cable replaced with marine grade cable.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 January 2019
Resolved
WOOD FOUND IN CROSS DECK SHOWED EVIDENCE OF TERMITE DAMAGE. REPAIR DAMAGED CROSS DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2019
Resolution: Cross deck renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2018
Resolved
An adult lifejacket must be provided for each person carried on board. 11 faulty life jackets found on board. Replace faulty life jackets. Adult passenger count is reduced to 121 until replacements are onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 18 July 2018
Resolution: Vessel rep emailed picture of new replacement lifejackets onboard.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 26 July 2017
Resolved
Replace unserviceable child life vest. Child passenger count is reduced to 13 until replacement is onboard. 46CFR180.71
Condition: Improper/Lack of Maintenance
Due 25 August 2017
Resolved 10 August 2017
Resolution: Replaced child life vest with new approved life vest.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 July 2017
Resolved
Provide suitable markings for child life vest. 46CFR180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided suitable markings as evidenced by photograph.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 26 July 2017
Resolved
Provide/post emergency instruction list. 46CFR185.510
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided/posted emergency instruction list as evidenced by photograph.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 26 July 2017
Resolved
Provide/post waste management plan. 33CFR151.57
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided/posted waste management plan as evidenced by photograph.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 July 2017
Resolved
Post employee assistance program for drug abuse prevention hotline numbers in a common space. 46CFR16.401
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Posted employee assistance program for drug abuse prevention hotline numbers in a common space as evidenced by photograph.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 26 July 2017
Resolved
Provide 1 additional portable light so that at least 2 are onboard and at operating station and at access to propulsion machinery space. 46CFR183.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 2 August 2017
Resolution: Provided 1 additional portable light as evidenced by photograph.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 June 2016
Resolved
01 Child and 05 Adult Life Jackets Unserviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new PFDs.
Lifesaving › Lifebuoys › Serviceable
Issued 17 June 2016
Resolved
Ring Buoy faded and line is deteriorated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new ring buoy.
Navigation › Piloting/Steering › Marine Charts
Issued 17 June 2016
Resolved
Nautical charts outdated.
Due 17 July 2016
Resolved 8 July 2016
Resolution: Vessel Rep provided reciepts for purchase of marine charts.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 June 2016
Resolved
Portable Fire Extinguishers expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2016
Resolution: Vessel provided reciepts for purchase of new extinghuisher.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 June 2016
Resolved
Operating instructions not posted at operating station and in space
Due 17 July 2016
Resolved 17 July 2016
Resolution: vessel provided proof of resolution.
Communications › Public Address System › Loudspeaker
Issued 17 June 2016
Resolved
No PA system installed, required to procure battery powered bull horn.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided reciept of purchase.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 June 2016
Resolved
Anchor deteriorated.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided reciept of purchase.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 June 2016
Resolved
Deck rail on stern gangway missing life lines.
Due 24 June 2016
Resolved 24 July 2016
Resolution: Vessel provided photographic evidence of resolution.
Construction/Loadline › Structures › Deck Plating
Issued 17 June 2016
Resolved
Stern swim platform not secured properly.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 17 June 2016
Resolved
STBD fuel tank vent line not properly secured to the fuel tank.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Tank
Issued 17 June 2016
Resolved
Fuel tank bonding wire not secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 June 2016
Resolved
Flexible cooling hose collapsed.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 June 2016
Resolved
Guard on STBD engine fire pump not functional/deteriorated.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2016
Resolved
STBD engine battery box cover missing.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2016
Resolved
Port Side generator battery not properly mounted/secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electric Supply System (service) › Cable
Issued 17 June 2016
Resolved
Exposed power wires on port engine alternator.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 June 2016
Resolved
Engine Tachometer guage at control station inoperable.
Due 17 July 2016
Resolved 17 July 2016
Resolution: Vessel provided proof of resolution.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2016
Resolved
Remove unused/exposed wiring.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Engineering › Fuel Oil Service System › Hose
Issued 17 June 2016
Resolved
Reroute port side generator fuel line, laying across deck/not secured.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Vessel provided proof of resolution.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 10 January 2011
Resolved
Conduct sea-trials prior to carrying passengers.
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 27 July 2011
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 10 January 2011
Resolved
Provide copies of CPR cards.
Due 27 August 2011
Resolved 2 September 2011
Stability › Watertight Integrity › Deadlight Cover
Issued 10 January 2011
Resolved
Repair as original securing devices for port lights.
Due 27 August 2011
Resolved 3 October 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 January 2011
Resolved
Make stbd fwd engineroom bulkhead vapor tight.
Due 27 August 2011
Resolved 2 September 2011
Engineering › Fuel Oil Service System › Piping
Issued 10 January 2011
Resolved
Remove epoxy patch from stbd F/O return line and stbd exhaust piping.
Due 27 August 2011
Resolved 9 September 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 January 2011
Resolved
Remove hose clamp and rubber from stbd exhaust piping make a permanant repair.
Due 27 August 2011
Resolved 3 October 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 January 2011
Resolved
Fasten stbd engineroom ladder.
Due 27 August 2011
Resolved 3 October 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 January 2011
Resolved
Claean all battery terminals.
Due 27 August 2011
Resolved 2 September 2011
Electrical › Electric Generation Source (service) › Generator
Issued 10 January 2011
Resolved
Provide data plate for generator IAW 46CFR183.10-5(a)
Due 27 August 2011
Resolved 3 October 2011
Fire Fighting › Combustible Materials › Insulation
Issued 10 January 2011
Resolved
Remove all spray foam from the vessel.
Due 27 August 2011
Resolved 2 September 2011
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 10 January 2011
Resolved
Provide locking devices on sewage ovbd discharge valves.
Due 27 August 2011
Resolved 2 September 2011
Construction/Loadline › Hull › Side Shell
Issued 21 January 2009
Resolved
Worklist - Starboard - Found wet-rotted planks in hull, inboard 18' from stern 18" above turn of bilge. Crop out rotted wood and repair planks IAW NVIC 7-95. Note: Rotted wood appears to involve both layers of planks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Damge exclusive of exterior plank. One exterior plank cropped and renewed with 12:1 scarf, sealed with epoxy resin and painted.
Construction/Loadline › Hull › Side Shell
Issued 21 January 2009
Resolved
Worklist - Port - Found rotted wood on stem outboard 3" in from the edge, 18" below waterline. Crop out rotted wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: One damaged exterior plank indentified. Plank cropped approx 13" aft of stem and renewed with new wood. Sealed with epoxy resin and painted.
Construction/Loadline › Hull › Side Shell
Issued 16 January 2009
Resolved
Worklist - Fasteners - Due to high percentage of wasted and necked exterior fasteners found on the 14th and 15th, vessel is to be re-fastened as follows: Port Hull - Entire hull. Stbd Hull - Aft of frame #12. Vessel rep/surveyor proposed refastening with #10, 3.5" galvanized deck screws consistent with majority of existing steel fasteners. Proposal approved 27 January.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Refastening completed IAW approved plan. Installed at 6" intervals AWL and at 4" intervals BWL on each frame.
Construction/Loadline › Hull › Keel
Issued 16 January 2009
Resolved
Worklist - Fasteners - Remove wormshoes and pull (3) keel bolts from each hull, (1) forward, (1) midship, (1) aft. (Vessel surveyor proposed a keelbolt refastening schedule rather than removal of old keel bolts due to likely destruction of wooden keel integrity likely when pulling keel bolts. Re-fastening plan approved.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: IAW approved plan: installed sister frames with new 5/8" galv-steel keel bolts at every fourth frame in each hull through metal keel plate. Holes in keel plate sealed with epoxy resin. Frames #7, #11, #15, and #19 refastened in 2009.
Fire Fighting › Structural - Horizontal Zones › General
Issued 15 January 2009
Resolved
Worklist - Starboard - Found plywood installed to provide a vapor seal in the engineroom rotted and missing foam sealant. Replace vapor tight boundary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Vapor barrier reinstalled and foam sealed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 15 January 2009
Resolved
Worklist - Starboard - Found engine room hatch separated from the hinge. Re-attach the engine room hatch to hinge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: New hinge installed.
Engineering › Bilge Water Management System › Piping
Issued 15 January 2009
Resolved
Worklist - Port and Starboard - Found 6" heavily pitted bilge/fire main piping directly beneath the engine room hatch forward of the half-frame at the ladder. Crop and renew bilge/fire main piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2009
Resolution: All deteriorated bilge piping replaced in stbd and port hulls. Operationally checked prior to getting underway.
Construction/Loadline › Hull › Transverse Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found dry rot (angel hair) as follows: a. Lazerette: inboard of exhaust. b. Fuel tank space: overhead outboard of fuel tank, transverse beam in wing aft-most beam. c. 4th frame from stern at knee. d. Engine space: Frame 15 near aft inboard corner of engine, overhead bulkhead of wing inboard of generator. Sand to good wood and protect as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: All dry rot sanded and treated/sealed throughout.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 January 2009
Resolved
Worklist - There are no guards on the bilge/fire pump levers located at the engine power take-offs (PTO). Install protective guards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2009
Resolution: Fabricated guards installed over exposed belts near PTOs.
Construction/Loadline › Hull › Keel
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted wood on the keel near the keel bolt aft of rudder post in the lazerette. Grind to good wood and preserve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Rotted wood removed and then new piece scarfed in. Secured with screws and glue. Keel bolt retightend.
Construction/Loadline › Hull › Transverse Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted wood on frame 18 inboard below the step entrance and at hull/wing junction inboard of fire extinguisher in the fuel tank space. Expose good wood to determine extent of damage, and make available to USCG prior to completing repair. (Note: rotted plywood cropped out about 21January)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: Bad wood was cropped and renewed in all places and adequately sealed.
Construction/Loadline › Hull › Transverse Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted wood on frame #17 inboard of the fuel tank below engine exhaust. Expose to good wood and make available to USCG to determine extent of damage prior to completing repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Damage confined within outer, 3/4" plywood frame, fwd of 2"x12" center frame member. Damaged plywood removed and replace in kind and secured with bronze fasteners.
Construction/Loadline › Hull › Keel
Issued 15 January 2009
Resolved
Worklist - Port Found rotted wood on the keel below the fuel tank. Grind to good wood and preserve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: Area cleaned to good wood and treated.
Construction/Loadline › Hull › Transverse Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted wood on frame #16 inboard at junction with vertical. Expose to good wood and make available to USCG to determine extent of damage prior to completing repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Damage confined within outer, 3/4" plywood frame, fwd of 2"x12" center frame member. Damaged plywood removed and replace in kind and secured with bronze fasteners.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted wood on longitudinal inboard of engine between the 15th and 16th frames in the wing. Expose to good wood and make available to USCG to determine extent of damage prior to completing repair. Repair plan to consist of grinding to good wood and preserving or cropping and scarfing in new wood depending on depth of wood rot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Damage was rotted 2x4 support and 3/4 plywood underwing decking. Void discovered behind and underneath same. Repair entailed cropping and removing damaged wood, installation of 4x4 in void space, new 2x4 and plywood. Secured w/bronze screws.
Construction/Loadline › Hull › Side Shell
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted planks and transverse frame #10 at turn of bilge, outboard below storage door sill with deteriorated fastener hole. Provide repair proposal and crop and renew per approved plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotted planks cropped and renewed and frame/door sill cropped and renewed to approx hull centerline IAW approved plan. Fastener hole plugged with new fastener installed.
Construction/Loadline › Hull › Transverse Frame
Issued 15 January 2009
Resolved
Worklist - Port - Found rotted transverse gussets, frame and joint with planks at frame 11 at turn of bilge. Provide repair proposal and crop and renew per plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: 3/4" p;ywood gussets on either side of 1-1/2" fir center frame cropped and renewed and coated with epoxy resin. New 5/8" glav-steel keel bolt installed as part of keel bolt refastening schedule.
Construction/Loadline › Structures › Superstructure
Issued 15 January 2009
Resolved
Worklist - Cabin - Found rotted wood in cabin port aft PFD compartment under seat. Crop and renew. (Note: possibly ties into rotted longitudnal in engine room.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotted wood cropped, renewed and sealed with epoxy resin.
Construction/Loadline › Structures › Superstructure
Issued 15 January 2009
Resolved
Worklist - Cabin - Found rotted wood on port aft window sill in main cabin from aft corner to approx 4' forward. Crop and renew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2009
Resolution: Rotted wood cropped and renewed.
Construction/Loadline › Structures › Superstructure
Issued 15 January 2009
Resolved
Worklist - Cabin - Found dry-rotted paneling in the cabin ceiling. This item noted verbally during past inspections. Due to lack of attention over several years, suspect overhead is now more suceptable to fire hazard. Crop and renew dry-rotted overhead paneling.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotteed paneling cropped and renewed.
Construction/Loadline › Structures › Superstructure
Issued 15 January 2009
Resolved
Worklist - Cabin - Found rotted wood under cabin roof in port aft corner. This item also verbally noted at past inspections but has continued unabated. Crop and renew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotted wood cropped, renewed, sealed and painted.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 15 January 2009
Resolved
Worklist - Port Engine - Found aft engine mount bolts loose. Re-secure engine mounts to engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: New bolts installed.
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 January 2009
Resolved
Worklist - Sea Valves - Found (4) of the sea valves removed for inspection were inoperative or difficult to operate. Repair/replace identified valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2009
Resolution: Two valves were cleaned to satisfactory condition and two others were renewed. Valves checked sat during water re-entry, no leaks noted.
Electrical › Electric Generation Source (service) › Conductor
Issued 15 January 2009
Resolved
Worklist - Port - Found battery cable exposed to weather due to inadequate splice protection. Replace/insulate battery cable against weather exposure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Splice and wires removed. New wire installed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 January 2009
Resolved
Worklist - The vessel appears not to be in substantial compliance with regulations, especially concerning condition of structures and fasteners. Provide a marine surveyor's report attesting to the condition of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Received copy of marine surveyors report attesting to condition of vsl as fit for intended service post dry-dock. Concur with report.
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 15 January 2009
Resolved
Worklist - Make vessel available for a post-drydock operational sea trial.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Resolution: Conducted in water-post drydock exam and sea trial. Witnessed all thru hull fittings (no leaks), bilge system op check, all repairs below the waterline appeared to be sat, no immediate leaks noted, tested propulsion ahead and astern and steering sys sat.
Construction/Loadline › Structures › Superstructure
Issued 14 January 2009
Resolved
Worklist - Found broken brackets at bows for underdeck longitudinal support for foredeck. Replace the port and starboard outboard brackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: New brackets and fasteners installed along with 6" lag screws inserted from above deck into beams.
Construction/Loadline › Structures › Superstructure
Issued 14 January 2009
Resolved
Worklist - Found damaged wood in vicinity of bow ladder support cleats. Remove cleats, grind to good wood and replace cleats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotted wood cropped, renewed and sealed.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found damage to hull outboard 19' from stem, 3' below waterline consisting of eroded FRP sheath and exposed wet-rotted wood approx 2'X4' in area. Exposure revealed extensive damage to planking and associated transverse frame 7. Provide repair proposal and complete repairs per approved plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Rotted interior and exterior planks and all of lower section of frame #7 cropped and renewed. Interior planks replaced w/ 3/4'' plywood from frames #6 to #8. All wood sealed with epoxy resin. Exterior filled in for asthetics, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found damage to hull outboard 13' from stem at turn of bilge consisting of exposed wood and weeping FRP sheath. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, resealed and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found delaminating sheath and running rust from fasteners 18' from stem, 1' below waterline. Grind, repair, and replace fasteners.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found soft FRP sheath and running rust 2' below waterline below the 5th portlight. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found compromised FRP sheath and soft wood below the 6th portlight. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found delaminated sheath and exposed wood 9' forward of the stern at the waterline, approx 1' X 2' in area. Grind to good wood and repair. Retain fasteners removed from this and other repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found delaminated FRP and exposed wood, running rust and weeping at waterline below the 3rd portlight. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Port - Found wet-rotted wood in underwing near hull joint, inboard, amidship. Crop out to good wood, repair and re-sheath. Make this and other repairs available for USCG inspector prior to re-sheathing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Keel
Issued 14 January 2009
Resolved
Worklist - Starboard - Found delaminated FRP on keel at stem. Grind out and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found small dent/soft spot in FRP 6' from stem, 1' above waterline as a result of collision with a jet-ski. Provide repair plan to USCG. Grind to good wood and repair. (Note: Repair ultimately required replacement of plywood skin including butt block).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: IAW approved repair plan; exterior plywood removed, 13"x21'''' interior plywood cropped and renewed with 17"x25'''', 3/4" plywood backing installed. New exterior plywood installed. Sealed with epoxy resin, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found exposed wood approx 8' from stem, 40" X 12" in area. Provide repair plan to USCG prior to crop out and renewal of planks, then complete repair per approved plan. Further examination revealed deteriaration to outer planks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Three outer planks cropped and renewed with 12:1 scarf and one outer plank (second from top) butt jointed IAW approved repair plan, from bow to approx 13'''' aft . Area sealed with epoxy resin, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found exposed wood approx 3' below waterline below 6th portlight. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found exposed wood and weeping 1' below waterline approx 1' aft of the 6th portlight. Grind to good wood and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found soft wood at bilge/fire pump suction inlets where hardware secured strainers to the hull. Grind/dry to good wood and reinstall/replace /reseal strainers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, fastener renewed, new FRP applied, sanded and painted.
Construction/Loadline › Penetrations › Valve Flange
Issued 14 January 2009
Resolved
Worklist - Stbd - Vessel rep is sealing (2) unused throughhulls outboard 11' forward of stern keel, the 1st 1' above the W/L and the 2nd 30" below. Repair IAW plan: a. Grind exterior out in prep to fair in sheathing. b. Crop interior to scarf/inlay new 1/4" marine plywood. c. Insert dowels. d. Screw and glue dowels and inlay. e. Re-sheath.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Repairs made IAW approved plan.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Starboard - Found delaminated FRP inboard near keel 6.5' from keel stern. Grind out and re-sheath.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Area ground to good wood, dried, new FRP applied, sanded and painted.
Construction/Loadline › Hull › Side Shell
Issued 14 January 2009
Resolved
Worklist - Exterior Fasteners - Pull as follows: a. (1) from stbd aft wing-hull bracket connection. b. (2) from each keel metal wormshoe. c. Retain all fasteners salvaged from hull repairs. d. (3) from port aft 4'-5' forward of stern approx 3' above W/L as marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Pulled as required with the following results; 95% taken from jet-ski hit repair (fwd stbd bow abv W/L) and 83% above W/L port aft were necked & wasted. As a result worklist #20 required: refasten entire port hull and stbd hull aft of frame #12.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 January 2009
Resolved
Worklist - Internal Fasteners - Pull as follows: Stbd Lazerette: Middle fastener from 1st side vertical member outboard & bottom fastener from 1st side vertical member inboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Outboard moderately wasted, threads cleaned, new nut installed & tightened. Inboard had wasted threads & couldn''t be removed due to boat structure. Sistered bottom fastener approx 4'' above old. Top bolt appeared in good shape. New bolt installed however
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 January 2009
Resolved
Worklist - Port Lazz - Found rotted wood on bottom, fwd face of frame #20. Crop and renew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2009
Resolution: Damage was relegated to outer 3/4" plywood. Entire piece (width of frame) was repalced with new plywood, adhesive and 304 S/S screws.
Construction/Loadline › Structures › End Bulkhead
Issued 14 January 2009
Resolved
Worklist - Cabin - Found rotted wood under cabin roof at stbd, inside, aft corner approx 5' fwd of aft corner and 3' to center from corner. Crop and renew.
Action required: 705 - Other - as specified
Resolved 22 March 2009
Resolution: Entire aft corner rebuilt, all rotted wood cropped and renewed.
Engineering › Bilge Water Management System › Piping
Issued 14 January 2009
Resolved
Worklist - Port - found severely deteriorated bilge piping throughout vsl. Renew deteriorated bilge piping in kind. Incorporated with worklist #25.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2009
Resolution: Piping in both port and stbd main hull and eng room spaces was renewed. operationally tested sat during post exan sea trial.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 January 2009
Resolved
Worklist - Port and STB - found automatic bilge pump wiring lying in bilge. Relocate wires away from bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2009
Resolution: Wires were reloacted appx 12" above the bilge and secured to longs with metal fasteners.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 January 2009
Resolved
Worklist - found interior cabin lights not to UL standards. Renew to meet standard.
Due 18 March 2009
Resolved 26 February 2009
Resolution: New lights installed to meet 33 CFR/ABYC standards IAW MSC.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 January 2009
Resolved
Worklist - found wiring to interior overhead cabin lights with non-standard connections (wire nuts and electrical tape). Rewire same to meet standard.
Due 18 March 2009
Resolved 26 February 2009
Resolution: Wire nuts were removed and replaced with environmental splices.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 26 June 2008
Resolved
Found installed system undersized when compared to approved plans. Provide measurements of engine compartments demonstrating installed Fireboy MA-2-700 meets the volume requirements, or provide Fireboy MA-2-900 system per approved plans.
Due 25 July 2008
Resolved 1 July 2008
Resolution: See Special Note regarding carriage of additional portable fire extinguishers.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 4 June 2008
Resolved
Found (1) BI portable fire extinguisher with loss of charge indicated in the pressure gauge. Recharge/replace the undercharged BI portable fire extinguisher. 46CFR 181.500
Due 11 June 2008
Resolved 1 July 2008
Resolution: Sighted new extinguisher installed to replace undercharged unit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 June 2008
Resolved
The Certificate of Inspection on the vessel is missing all pages after the first page. Post entire COI on the vessel. 46CFR 176.302,
Due 4 July 2008
Resolved 1 July 2008
Resolution: Current COI (all pages) posted in visible location.
Stability › Watertight Integrity › Deadlight Cover
Issued 4 June 2008
Resolved
The deadlight just forward of the engine in the stbd hull is missing (2) clamps. Replace missing clamps so that the deadlight may be firmly secured. 46CFR 171.117
Due 4 July 2008
Resolved 1 July 2008
Resolution: New deadlight assembly installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 June 2008
Resolved
The stbd entrance forward stanchion is holed. Repair the holed stanchion.
Due 4 July 2008
Resolved 1 July 2008
Resolution: Sighted welded repair in stanchion.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 4 June 2008
Resolved
The men's toilet is inoperative and has been replaced with a small port-a-potty. The vessel is certificated to carry up to 149 passengers with 4 crew and the working toilet facilities are inadequate to the task. Repair the inoperative macerator on the men's toilet. 01Jul08: extended repair to 14Jul08.
Due 14 July 2008
Resolved 10 July 2008
Resolution: Sighted reconnected toilet and observed proper operation.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2008
Resolved
The required masthead light is not installed. In its place is an all around white light of low luminosity. Install a masthead light visible for 5 miles and covering an arc of visibility from right ahead to 22.5 degrees abaft the beam on either side of the vessel. (225 degrees total).
Due 4 July 2008
Resolved 1 July 2008
Resolution: Sighted new masthead light installed meeting luminosity and arc of visiblity requirements.
Fire Fighting › Means of Escape › Stairways
Issued 4 June 2008
Resolved
The emergency means of escape from the port and stbd toilet facilities is blocked by a table and other loose gear. Clear, and keep clear the emergency escape route from the toilets.
Action required: 705 - Other - as specified
Resolved 4 June 2008
Resolution: The table and other obstructions were moved to unblock emergency egress from the toilet facilities.
Engineering › Fuel Oil Service System › Valve
Issued 4 June 2008
Resolved
The remote shutoff valve for the port fuel tank required by 46CFR 182.455(a)(4) does not completely close the fuel flow. Adjust the shutoff to completely close fuel shutoff valve.
Action required: 705 - Other - as specified
Resolved 4 June 2008
Resolution: The remote fuel oil cut-off arrangement was adjusted to provide for complete cut-off.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 4 June 2008
Resolved
Found fwd port CO2 portable fire extinguisher discharge nozzle corroded inside of horn. Clean or replace as necessary to make operable IAW 46CFR176.810 (a) (1).
Due 8 July 2008
Resolved 10 July 2008
Resolution: Sighted new discharge nozzle on port portable CO2 bottle. Verfied good condition of the stbd CO2 nozzle.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2007
Resolved
Prove proper operation of the installed engine-driven bilge & fire pumps. (46CFR182.520 & 46CFR 181.300) Vessel is restricted to the carriage of no more than 49 passengers and the meantime (3) 2.5 gallon fire buckets must be provided.
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 7 August 2007
Resolution: Engine-driven bilge and fire pumps tested. Bilge water removal is adequate. Fire-fighting water provided is marginal. Vessel is equipped with Fireboy fixed gas extinguishing systems and ample portable fire extinguishers.
Engineering › Bilge Water Management System › Pump
Issued 25 July 2007
Resolved
Prove proper operation of hte 10 GPM portable bilge & fire pump. (46CFR 182.520)
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 7 August 2007
Resolution: New pump purchased and demonstrated satisfactorily.
Fire Fighting › Fire Hoses › Material
Issued 25 July 2007
Resolved
Provide (2) 50' lined commercial fire hoses. (46CFR 181.320(b) (1))
Action required: 705 - Other - as specified
Due 1 August 2007
Resolved 7 August 2007
Resolution: Sighted proper hoses in place on vessel.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 25 July 2007
Resolved
Clean/repair port and stbd fuel tank ventilation screens. The stbd screen is painted over and the port screen is holed. (46CFR 182.450)
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 7 August 2007
Resolution: Sighted newly installed proper fuel tank ventilation screens.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 25 July 2007
Resolved
Repair/replace the port and stbd propulsion engine tachometers. (46CFR 182.410(b)
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 10 July 2008
Resolution: Observed proper operation of the tachometers.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 25 July 2007
Resolved
Provide scientific method for completing random drug screening. (46CFR Part 16)
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 4 June 2008
Resolution: Completed program audit and noted random screening selected by computer system.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 3 May 2006
Resolved
Replace deteriorated fuel tank vent hose and properly install in an upward gradient.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2006
Resolved 3 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2006
Resolved
Provide service report for all fire fighting equipment prior to expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 16 January 2007
Resolution: Sighted Oahu Fire Protection, Inc. servicing report dated 9 May 2006 for fixed and portable fire extinguishers
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 September 2005
Resolved
Provide serviced B-I fire extinguisher properly mounted at wheelhouse prior to operating/sailing with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2005
Resolution: Provided serviced B-I fire extinguisher properly mounted at wheelhouse prior to operating/sailing with passengers.
Engineering › Bilge Water Management System › Not Operational
Issued 27 September 2005
Resolved
Make all audible/visual bilge/highwater alarms operable prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2005
Resolution: Provided operable audible/visual bilge/highwater alarms prior to operating with passengers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 May 2005
Resolved
Prove operation of fixed gas fire-fighting system to include engine shut-downs IAW 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2005
Engineering › Bilge Water Management System › Not Operational
Issued 16 May 2005
Resolved
Prove operation of bilge system IAW 46 CFR 182.510.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2005
Resolved 23 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2005
Resolved
Label location and make available to passengers IAW 46 CFR 184.710.
Due 30 May 2005
Resolved 23 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 May 2005
Resolved
Mount all portable fire extinguishers IAW 46 CFR 181.520.
Due 30 May 2005
Resolved 23 May 2005
Fire Fighting › Fire Pumps › Power Source
Issued 16 May 2005
Resolved
Prove operation of fire pump driven off port main engine (engine inoperable) IAW 46 CFR 181.10.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2005
Resolved 23 May 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 May 2005
Resolved
Make vessel ready for USCG COI inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2005
Stability › Watertight Integrity › Deadlight Cover
Issued 12 May 2005
Resolved
Secure/repair all deadlight covers IAW 46 CFR 171.117 and 179.350.
Due 30 May 2005
Resolved 30 May 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 May 2005
Resolved
Mark means of escape from passenger accessible spaces IAW 46 CFR 185.606.
Due 30 May 2005
Resolved 23 May 2005
Engineering › Bilge Water Management System › Not Operational
Issued 12 May 2005
Resolved
Prove operation of bilge high level alarms IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 12 May 2005
Resolved
Prove proper operation of port main engine. Vessel transmission gear is sheared. Vessel will not engage foward or reverse.
Condition: Unknown
Due 23 May 2005
Resolved 31 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 May 2004
Resolved
Renew expired aspirin and re-supply existing contents of first aid kit.
Due 26 May 2004
Resolved 26 May 2004
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 May 2004
Resolved
Renew FCC Safety Radiotelephony Certificate.
Due 26 May 2004
Resolved 26 May 2004
Construction/Loadline
Issued 24 July 2003
Resolved
Due to extensive drydock repairs, and numerous safety item deficiency list on surveyors report, vessel is required to complete a annual inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2003
Stability › Watertight Integrity
Issued 29 May 2002
Resolved
Repair/replace dead light covers in port engine room and port stairway leading to head in accordance with 46 CFR 179.350. LEGACY COMPONENT DESC: Deadlight covers
Condition: Improper/Lack of Maintenance
Due 14 June 2002
Resolved 12 May 2003
Construction/Loadline › Structures
Issued 29 May 2002
Resolved
Make permanent repairs to rotted keelson in starboard ama in way of starboard rudder in accordance with 46 CFR 177.100 and NVIC 7-95. LEGACY COMPONENT DESC: Keelson
Condition: Improper/Lack of Maintenance
Due 7 June 2002
Resolved 12 May 2003
Construction/Loadline › Structures
Issued 29 May 2002
Resolved
Make repair proposal and submit for review for repairs to be conducted to keelson in accordance with 46 CFR 176.700. LEGACY COMPONENT DESC: Keelson
Due 7 June 2002
Resolved 12 May 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 May 2002
Resolved
Repair/replace port engine oil pressure guage at control station in accordance with 46 CFR 182.15.5(b). LEGACY COMPONENT DESC: Oil pressure gauge
Condition: Improper/Lack of Maintenance
Due 14 June 2002
Resolved 12 May 2003
Construction/Loadline
Issued 30 May 2001
Resolved
Provide a rigging survey report prior to operating with passengers under sail. Alternately provide written report detailing how sailing rig has beendisabled to preclude sailing in accordance with 46 CFR 177.330.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Engineering
Issued 30 May 2001
Resolved
Prove condition of the starboard fuel tanks in accordance with 46 CFR 182.440(b).
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Construction/Loadline
Issued 30 May 2001
Resolved
Repair or replace (1) chainplate in port head and (2) chainplates in each_x001C_ engine compartment in accordance with 46 CFR 177.330 prior to operating with passengers under sail.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Navigation
Issued 12 May 2000
Resolved
Provide applicable section of U.S. Coast Pilot (Kaneohe Bay), iaw 46CFR 184.420.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 12 May 2000
Resolved
Prove proper operation of the Fireboy fixed gas system alarms iaw 46CFR 176.810(a)(7).
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
Provide bilge alarm in port and starboard hulls, forward compartment (mid- section), iaw 46CFR 182.530(b).
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Lifesaving
Issued 12 May 2000
Resolved
Provide battery operated bullhorn for public address iaw 46CFR 184.610.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 18 June 1999
Resolved
Accomplish repair to automatic engine shutoff solenoid for Fireboy Fixed Gas firefighting system.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Construction/Loadline
Issued 18 June 1999
Resolved
Crop and renew as original rotted wood planking/plywood in vicinity of portengine room air intake (where brackets were re-attached). Bad wood extends60" X 18" in port engineroom overhead.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 18 June 1999
Resolved
Acquire approved 1st Aid Kit for vessel.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Construction/Loadline
Issued 16 June 1998
Resolved
Renew the raw water through hull valve for the port engine intake prior to sailing with passengers.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Engineering
Issued 9 December 1997
Resolved
Flush and remove all water and deposits from both main diesel fuel tanks.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Electrical
Issued 22 May 1997
Resolved
Remove dead end wire run in port engineroom.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Construction/Loadline
Issued 22 May 1997
Resolved
Repair or replace watertight hatches for both enginerooms.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Accommodation/Occupational Safety
Issued 22 May 1997
Resolved
Safely secure access ladders for both enginerooms.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Construction/Loadline
Issued 22 May 1997
Resolved
Rmove excess oily waste from engine room bilges.
Condition: Unknown
Due 22 May 1997
Resolved 22 May 1997
Construction/Loadline
Issued 28 June 1996
Resolved
Reposition the starboard forward bilge suction so that it is properly positioned in the lower bilge area. Suction opening is presently about 8 inches above the lowest point in the bilge.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Engineering
Issued 28 June 1996
Resolved
Replace the starboard fuel line short section of hose in way of the previously removed external fuel pump and replace with an approved type hose.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Engineering
Issued 28 June 1996
Resolved
Replace the worn generator exhaust hoses from the engine to the muffler andfrom the muffler to the overboard connection.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Engineering
Issued 28 June 1996
Resolved
Reinstall the two port fuel tank fill connections into the new section of the main deck.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Fire Fighting
Issued 28 June 1996
Resolved
Provide mounting bracket for the galley portable CO2 extinguisher.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 28 June 1996
Resolved
Make permanent repairs to all wire runs. Remove all twist lugs and replacewith crimp type lugs, either remove or dead end any unused cables & providemetal cable straps properly spaced for all horizontal cable runs.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Lifesaving
Issued 28 June 1996
Resolved
Provide 55 adult PFDs. Vessel limited to 98 adult passengers until the new PFDs are on board.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Engineering
Issued 28 June 1996
Resolved
Provide insulation on both main engine exhaust pipes from the engine to thecooling water inlet connections.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 7 June 1996
Resolved
Provide portable lights at helm and port and starboard engine room access in accordance with IFR 46 CFR 183.430.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
Install positive shutoff valves at hull penetrations for electric submersible bilge pumps (2) in accordance with new T regulations.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Engineering
Issued 7 June 1996
Resolved
Prior to carrying passengers for hire, install 30X30 mesh flame screens on port and starboard fuel tank vents.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Navigation
Issued 7 June 1996
Resolved
Provide emergency broadcast placard in accordance with IFR 46 CFR 184.506.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Accommodation/Occupational Safety
Issued 7 June 1996
Resolved
Replace broken stanchion #2 on starboard side of main deck.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Accommodation/Occupational Safety
Issued 7 June 1996
Resolved
Tighten stanchions #3-4 on starboard side and #2 on port side of main deck.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 7 June 1996
Resolved
Provide documentation of fire fighting drills and training in accordance with IFR 46 CFR 185.524.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Lifesaving
Issued 7 June 1996
Resolved
Install retroreflective tape on ring buoy in accordance with IFR 46 CFR 185.604(i).
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Deck/Cargo
Issued 7 June 1996
Resolved
Replace rotten shim on port side of mast step.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
Label port and starboard bilge manifolds.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Documentation
Issued 7 June 1996
Resolved
Prior to carrying passengers for hire, provide written drug testing policy,employee acknowledgements, negative drug test results and documentation of supervisor training in accordance with 46 CFR 16.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Construction/Loadline
Issued 7 June 1996
Resolved
Make proper repairs to port forward engine room hatch.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Lifesaving
Issued 7 June 1996
Resolved
Provide brightly colored, portable watertight container marked "DISTRESS SIGNALS" in at least 0.5-inch letters in accordance with IFR 46 CFR 185.614.
Condition: Unknown
Due 7 July 1996
Resolved 13 June 1996
Lifesaving
Issued 7 June 1996
Resolved
Provide documentation of crew training in accordance with IFR 46 CFR 185.420.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Lifesaving
Issued 7 June 1996
Resolved
Provide life jacket placards in accordance with IFR 46 CFR 185.516.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Lifesaving
Issued 7 June 1996
Resolved
Provide documentation of abandon ship and man overboard drills and trainingin accordance with IFR 46 CFR 185.520.
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Electrical
Issued 1 June 1995
Resolved
REPLACE AS PER ORIGINAL SENSOR TO MAKE PORT ENGINE WATER TEMPERATURE GAUGE OPERABLE.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Electrical
Issued 12 January 1995
Resolved
REMOVE ALL DEAD END ELECTRICAL WIRES OR CAP OPEN ENDS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Electrical
Issued 12 January 1995
Resolved
MAKE ALL TAPED ELECTRICAL CONNECTIONS OF A PERMANENT MARINE APPROVED TYPE THROUGHOUT THE VESSEL.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Lifesaving
Issued 12 January 1995
Resolved
REMOVE ALL HAZARDOUS MATERIAL FROM VESSEL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Construction/Loadline
Issued 12 January 1995
Resolved
REPAIR/REPLACE ALL PORT LIGHT COVERS AND HARDWARE AS PER ORIGINAL.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Construction/Loadline
Issued 12 January 1995
Resolved
REPLACE #2 AND #6 PORTLIGHTS AND REMOVE ROTTED WOOD IN AND AROUND OPENING.
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Accommodation/Occupational Safety
Issued 1 June 1994
Resolved
MAKE PERMANENT REPAIRS TO THE PUMP OUT LINE CONNECTION AT THE TOP OF BOTH MSD TANKS TO MAKE THE CONNECTION GAS TIGHT.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Engineering
Issued 1 June 1994
Resolved
REPLACE STARBOARD ENGINE COOLING WATER INLET HOSE.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Electrical
Issued 1 June 1994
Resolved
MAKE PERMANENT REPAIRS TO THE COOLING WATER INLET GASKET ON THE GENERATOR.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Fire Fighting
Issued 1 June 1994
Resolved
MAKE PERMANENT REPAIRS TO THE PORT FIRE/BILGE PUMP AND DEMONSTRATE SATISIFACTORY OPERATION TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Engineering
Issued 1 June 1994
Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD MAIN ENGINE OIL LEAK IN WAY OF THE EXAUST MAINIFOLD.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Lifesaving
Issued 2 June 1993
Resolved
PROVIDE SIGN INBOARD OF EMERGENCY EXITS WITH "EMERGENCY EXIT - KEEP CLEAR"
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Construction/Loadline
Issued 2 June 1993
Resolved
REPLACE SECURING DOGS FOR PORT LIGHTS.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Accommodation/Occupational Safety
Issued 2 June 1993
Resolved
REPLACE THE VENT FOR THE PORT HULL FORWARD OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Accommodation/Occupational Safety
Issued 15 June 1992
Resolved
PROVIDE ADEQUATE FIXED SEATING FOR 145 TOTAL PASSENGERS. PASSENGER TOTAL RESTRICTED TO 120 UNTIL FIXED SEATING IS INSTALLED ON BOARD.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Accommodation/Occupational Safety
Issued 14 May 1992
Resolved
PROVIDE ADEQUATE FIXED SEATING FOR 145 PASSENGERS. PASSENGER TOTAL IS RESTRICTED TO 120 UNTIL SUCH TIME AS ADEQUATE FIXED SEATING IS PROVIDED.
Condition: Unknown
Due 31 July 1992
Resolved 2 July 1992
Engineering
Issued 14 May 1992
Resolved
RENEW THE PORT ENGINE SEA SUCTION HOSE.
Condition: Unknown
Due 15 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 14 May 1992
Resolved
PROPERLY MARK THE NAME OF THE VESSEL ON BOTH SIDES OF THE OUTBOARD HULLS.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 14 May 1992
Resolved
PROPERLY MARK THE STATE LETTERS (HI) ON THE STERN OF THE VESSEL.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Electrical
Issued 14 May 1992
Resolved
LABEL THE ELECTRICAL SWITCH PANEL IN THE STARBOARD HULL WING VOID.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Engineering
Issued 14 May 1992
Resolved
PROVIDE A SECOND HOSE CLAMP FOR EACH OF THE 4 FILL HOSES ON THE FUEL TANKS.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Electrical
Issued 14 May 1992
Resolved
PROVIDE INFORMATION REGARDING THE USE OF THE 250V FUSES LOCATED IN THE STARBOARD HULL.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Engineering
Issued 14 May 1992
Resolved
RENEW THE BROKEN WATER TEMPERATURE GAUGE FOR THE STARBOARD ENGINE ON THE HELM CONSOLE.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Construction/Loadline
Issued 14 May 1992
Resolved
CROP AND RENEW TO GOOD WOOD THE DRY ROTTED PORTION OF THE MAST STEP.
Condition: Unknown
Due 10 June 1992
Resolved 25 June 1992
Navigation
Issued 14 June 1991
Resolved
RENEW STEERING CABLE.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Construction/Loadline
Issued 14 June 1991
Resolved
RENEW/REPLACE THE WOODEN KEEL AREA BY STBD RUDDER POST.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Construction/Loadline
Issued 14 June 1991
Resolved
REMOVE/TAKE DOWN TO GOOD WOOD IN STBD AFT STEERING COMPT.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Lifesaving
Issued 14 June 1991
Resolved
PROVIDE NEW LIFE LINE FOR LIFE RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Fire Fighting
Issued 14 June 1991
Resolved
SERVICE ALL CO2 PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
PROVIDE ELECTRICAL SWITCHBOARDS/DISTRIBUTION BOX FOR WIRING ATTACHED TO PORT AND STBD BATTERIES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
REMOVE ALL UNUSED ELECTRICAL WIRINGS. OUTLETS AND FIXTURES.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
REPLACE RUBBER FUEL HOSES WITH METTALIC FUEL HOSES TO AND FROM GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
PROVIDE BATTERY COVERS TO PORT AND STBD BATTERY BOXES.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
BLOCK THE BATTERIES IN THE BATTERY BOXES.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 14 June 1991
Resolved
PROVE OPERATION OF GENERATOR AND REPAIR THE MUFFLER.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 26 November 1990
Resolved
RENEW WIRING AND WIRING CONNECTORS AS NECESSARY IN ENGINE COMPARTMENTS.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Electrical
Issued 26 November 1990
Resolved
RENEW DEFECTIVE LIGHT FIXTURES BY THE MACHINERY SPACES.
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Navigation
Issued 14 June 1989
Resolved
DEMONSTRATE OPERATION OF MAST HEAD AND RANGE LIGHTS.VESSEL PROHIBITED FROM NIGHT OPERATION UNTIL COMPLETED.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Engineering
Issued 14 June 1989
Resolved
INSTALL HEAT SHIELDS ON RACOR PLASTIC FUEL FILTER BOWLS.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989
Resolved
DEMONSTRATE OPERATION AND EFFECTIVE WATER PRESSURE OF STBD FIRE PUMP.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Engineering
Issued 14 June 1989
Resolved
INSTALL GUARD OVER ROTATING PULLEYS/BELT ON AUXILIARY GENERATOR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Construction/Loadline
Issued 14 June 1988
Resolved
REPLACE PLASTIC PORTLIGHT WITH METALLIC PORTLIGHT AS ORIGINAL.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Construction/Loadline
Issued 14 June 1988
Resolved
AT NEXT DRY DOCK, REPLACE PLASTIC THROUGH HULLS WITH METALLIC FITTINGS.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Documentation
Issued 14 June 1988
Resolved
PROVIDE HEIGHT OF MAST, DISTANCE BETWEEN HULL CENTERLINES, SAIL AREA, AND DISPLACEMENT OF BOTH HULLS IN ORDER TO REVIEW STABILITY CRITERIA.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Unknown
Issued 10 June 1987
Resolved
PROVIDE 5 ADULT APPROVED LIFE PRESERVERS. UNTIL THIS ITEM IS COMPLETED, THE NUMBER OF PASSENGERS ALLOWED IS LIMITED TO 140.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987
Resolved
MAKE REPAIRS TO VHF RADIO VOLUME/SQUELCH CONTROL AND DEMONSTRATE PROPOER OPERATION OF SAME.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1987
Resolved
PROVIDE ONE HAND PORTABLE FIRE/BILGE PUMP ON BOARD THE VESSEL. UNTIL THIS IS COMPLETED, NO PASSENGERS MAY BE CARRIED.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Unknown
Issued 10 June 1986
Resolved
INSULATE SPLICED WIRES IN STARBOARD ENGINE COMPARTMENT.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
ELIMINATE DRY ROT IN STARBOARD ENGINE COMPARTMENT AND PORT AND STARBOARD RUDDER SHAFT COMPARTMENTS.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
PROVIDE SUPPORTS FOR STARBOARD ENGINE COMPARTMENT VENTILATION DUCT.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
REPLACE NIPPLE CONNECTING STARBOARD ENGINE COOLING WATER DISCHARGE TO THRU-HULL FITTING.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
REPAIR STARBOARD ENGINE COOLING WATER INTAKE VALVE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
ATTACH REMOTE FUEL SHUT-OFFS TO DIESEL FUEL LINES SERVICING MAIN ENGINES AND GENERATOR.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
REPAIR/REPLACE WATERLIGHT ON RING BUOY.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Unknown
Issued 10 June 1986
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF STARBOARD FIRE PUMP.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Lifesaving
Issued 10 June 1985
Resolved
REPLACE I.D. PLATE ON STARBOARD BUOYANT APPARATUS.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985