ONO MANA

ONO MANA is a 1980 passenger vessel (inspected). The Coast Guard has recorded 83 inspections since 1985, most recently in October 2025, along with 260 deficiencies — 2 with no resolution recorded —, 1 operational control and 3 casualty investigations between 2004 and 2013.

Records from 1985 to 2025. Most recent: inspection, 10 October 2025.

Built
1980
Last inspected
10 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTD4370
Flag
UNITED STATES
367331130
Maury page id
psix-53823

Inspections, by type

…with no type recorded7
Years with a record 36 calendar years (1985–2025)
The 83 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 31.0 ft × 6.0 ft
Registered tonnagegross 87 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HONOLULU · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
82 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTD4370MMSI 367331130 · active · compulsorily equipped · granted 10 January 2018, expires 24 March 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HULA KAI Passenger (Inspected) · MISLE 47193 · 21 February 2012 · activity 4249356

Inspection history · 83

10 October 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8254206
27 November 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8038371
21 October 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8016313
19 July 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7962394
21 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7820935
18 May 2023 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7681862
25 August 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7537755
7 June 2022 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7474029
21 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082054
1 June 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7093782
9 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6711332
30 May 2019 Administrative Inspection · In-Service Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6676169
19 January 2018 DAPI Audit · Internal Structural Exam · Examination of Repairs · Administrative Inspection · COI Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6340426
5 July 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6199041
13 April 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6121689
13 January 2016 Administrative Inspection · Drydock Exam · DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5825900
21 February 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4249356
30 December 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4216307
2 September 2011 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4134198
24 April 2009 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3460061
26 March 2009 Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3438736
16 January 2008 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3131449
24 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2939290
25 April 2007 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2916176
25 April 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2993051
17 March 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2604577
27 September 2005 Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2503394
21 July 2005 Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2339291
13 April 2005 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2331567
27 March 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2033466
26 January 2004 Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1980624
1 April 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1763004
24 January 2003 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1730897
30 January 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1481065
26 April 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449456
2 March 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1059091
2 February 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1058599
26 January 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376426
17 February 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815659
26 January 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369499
7 July 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1091747
25 May 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360901
7 April 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360794
26 January 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1462719
28 January 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364539
23 May 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1106550
18 April 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404345
11 March 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388222
29 January 1997 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1433149
18 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077584
15 February 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1192138
24 January 1996 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371283
1 May 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1435622
20 March 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357083
26 January 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1450939
22 March 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 3366
4 March 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1425417
15 February 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354577
28 January 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356501
27 April 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836768
30 March 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 831960
1 February 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1141676
7 August 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1261182
30 January 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1007314
26 November 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937034
25 October 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1253985
14 June 1991 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339467
1 March 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 912901
30 January 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926157
9 February 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1223700
26 January 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1223255
1 September 1989 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1194490
2 March 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 887541
6 February 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341656
15 December 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1209217
17 February 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1330442
29 January 1988 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018939
1 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1326916
20 February 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1327672
23 May 1986 Re-Inspection · Credit Drydock
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 986374
28 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1304480
27 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288701
25 February 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982519

Deficiency record · 260

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 October 2024 Resolved
Provision shall be made by means of plugs, covers, etc. to percent admission of air into the space. Ventilation louvers would not shut for both engine room spaces. 46 CFR 181.20-35 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2024
Resolution: Corrected. Louvers and assembly were rebuilt and added heavier material to close.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Port side mid-compartment and port side engine room bilge alarm is not operational. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2024
Resolution: Bilge alarm audible and visual are operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2024 No resolution recorded
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. 46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2024 No resolution recorded
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Vessel's O/O is developing a chemical testing program to include random-testing by third party, but has not completed the program. Provide satisfactory evidence of a chemical testing program. 46 CFR 16.230(a)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2024 Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers" and with the number contained therein, in at least 1-inch letters and figures. This legends shall indicate the separate stowage of children's life preservers. Missing port and starboard bench seating stowage markings for adult and child life preservers. 46 CFR 180.25-15(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: New signage was posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on vessels of not more than 65ft in length carrying not more than 49 passengers, provided that: The pump is permanently mounted. Bilge pumps and floats must be permanently mounted. 46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilge floats and pumps are mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilges were full of debris and rags. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilges in both engine rooms were clear of debris.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The bilge pipe on the port side mid-compartment was not properly secured. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilge pipe on the port side mid compartment was secured to a new 2 X 4 that was coated to protect from wood rot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Three holes were found in the port side engine compartment towards the stern. Replace with missing hardware. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Holes were filled and made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The battery banks located in both engine compartments have overloaded terminals. Provide an additional terminal post so no more than four cables/wires are on each post, an ensure locking nut is fully threaded on. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: A new battery terminal was installed for each battery bank and wires and were evenly distributated between batteries and new terminal with proper lugs and connectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 July 2024 Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per 176.615 of this part: (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo drydock examination and an internal structural at least once every two years. Vessel's drydocking due date of June 29, 2024 has lapsed and vessel is overdue for credit drydocking. Vessel is not to operate with passengers onboard or conduct any dry docking repairs unless approved by the attending marine inspector. 46 CFR 176.600(c)(1)
Action required: 705 - Other - as specified
Resolved 20 December 2024
Resolution: Received credit drydock. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 1 Life jacket was ripped and unserviceable. 14 of required 140 life jackets onboard had wasted or missing retroreflective material. Replace 1 unserviceable life jacket. Install retroreflective material on 14 life jackets. Vessel passenger count reduced from 128 passengers to 113 passengers until deficiency is corrected. 46 CFR 180.71 46 CFR 185.604
Action required: 705 - Other - as specified
Resolved 4 December 2023
Resolution: Received photograph of new life jacket with appropriate markings. Additionally, received photograph of newly installed retroreflective material on 14 affected life jackets.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 November 2023 Resolved
Endorsements on Certificates of Documentation are valid for one year. Vessel's Certificate of Documentation expired on April 30, 2023. Provide proof that vessel owner has applied for renewal and received endorsement for a valid Certificate of Documentation. 46 CFR 67.163
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Received photograph of valid COD for the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 November 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. Vessel's FCC Safety Radiotelephony certificate is expired. Provide proof of a valid FCC Safety Radiotelephony certificate to attending marine inspector. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Received photograph of valid FCC Safety Radiotelephony Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 November 2023 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material. Vessel's valid COI is not posted or kept onboard. Post vessel's valid COI in appropriate location. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Recieved photograph of valid COI posted onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmemeber assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Community service hot-line number and employer's EAP policy are not posted or kept onboard. Display employer's EAP policy and hot-line number onboard to the satisfaction of the marine inspector. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 8 December 2023
Resolution: Received photograph of employer's policy for drug/alcohol and hot-line number postage onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2022 Resolved
Vessels less than 65' carrying more than 49 passengers shall be outfitted with one fixed, power, bilge pump that is permanently connected to the bilge main. Both of the provided power bilge pumps were unable to dewater any of the compartments served by the bilge main. Vessel passenger count limited to 49 until the vessel is provided with a fixed, power, bilge pump capable of dewater all watertight compartments on the vessel. 46 CFR 185 2.25-10
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 September 2022
Resolution: Power bilge pumps were operational in all compartments.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2022 Resolved
An adult life jacket must be provided for each person on board a vessel. 12 Adult life jackets were either missing or un-serviceable. Vessel is restricted to 116 passengers until all life jackets required by the COI are provided. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 September 2022
Resolution: 12 new lifejackets were placed onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 August 2022 Resolved
Emergency exits used as a means of escape must be marked in legible letters "EMERGENCY EXIT, KEEP CLEAR". Markings provided were worn an illegible. Provide required markings. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2022
Resolved 7 September 2022
Resolution: Emergency exit was properly marked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 August 2022 Resolved
An audible and visual bilge high level alarm is required at the operating station for normally unmanned spaces with a non-watertight closure on the main deck. The audible and visual high water indicator for the port fuel tank space was inoperable. Provide the required alarm. 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Resolved 25 August 2022
Resolution: Bilge alarm provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 August 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds. The starboard forward stanchion, second from outboard and the starboard, aft stanchion for the forward ladder railings were not secure to the deck. Repair and secure to the satisfaction of the attending marine inspector. 46 CFR 176.25-1 46 CFR 177.900
Action required: 10 - Deficiency Rectified
Resolved 25 August 2022
Resolution: Railings were repaired and secured to the deck.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 June 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The fiberglass in way of the strut mount for the port and stbd hulls were cracked and presented indications of water intrusion and delamination. Grind back for further inspection. Hull material found wasted, crop and renew per approved plans. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 29 June 2022
Resolution: Repairs completed IAW approved plans and industry accepted procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020 Resolved
The owner or operator shall make a vessel available for drydock examinations. Vessels drydock was due 3/31/2020. Vessel must complete credit drydock with attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2022
Resolution: Vessel completed credit dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 June 2019 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss; vessels hatch covers does not have any device to prevent its loss. Attach hinges, captive chains or another device to prevent loss of hatch cover.-(OLD)46 CFR 171.124(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2019
Resolution: Received pictures hatch covers secured by stainless steel coated cable attached to wood frame by 1/4 inch eye
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel's starboard fuel tank void and port side forward void visual indicators are inoperable. Repair visual indicator for each void.-46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proving visual indicators have been repair and are operable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; Vessel's port midship void visual indicator indicates port midship void, port engine room, and port steering room is operating when only port midship void bilge pump is operating. Vessel must repair visual indicators to indicate when the correct bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proving each individual visual indicator is now operating for the correct bilge pump.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2019 Resolved
Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such a system. Cross space unites port and starboard engine rooms, thus creating one space. Secure cross space to separate engine rooms-46 CFR 181.420(c)
Action required: 705 - Other - as specified
Due 11 June 2019
Resolved 11 June 2019
Resolution: received photo. Cross spaces have been secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 June 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system; Closure devices for port and starboard engine room spaces does not properly close to secure ventilation. Repair closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video showing the operation of securing devices. Vessels closure devices properly secure each engine room
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice; Vessel's port side drip less shaft seal is constantly leaking into engine room. Repair shaft seal. -46 CFR 176.800(a)
Action required: 705 - Other - as specified
Due 11 June 2019
Resolved 11 June 2019
Resolution: Received video proving drip less shaft seal has been repaired and no longer leaking.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2019 Resolved
Repairs and alterations that affect the safety of the vessel must not be made without the approval of the cognizant OCMI; Vessel's swimming platform starboard support bracket is cracked at welding. Repair cracked welding on support bracket. Passengers are not allowed on swimming platform until repaired.-46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2019
Resolution: Received photos of weld repair. vessel rep tested secureness of swimming platform. Platform is secure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Submersible electric power pumps in port side steering void, starboard mid void, and piping for fixed power hand pumps are not secure. Secure submersible electric pumps and piping for fixed power pumps - 46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proof submersible electric pump has been secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 June 2019 Resolved
Repairs and alterations that affect the safety of the vessel must not be made without the approval of the cognizant OCMI; Vessel's forward port cleat has loosened and cracked the surrounding deck. Make surrounding deck around the cleat watertight.-46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel has renewed surrounding deck around cleat. Deck is now watertight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 June 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 applied at any point in any direction. Forward deck rails are loose from deck. Tighten stanchions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received photos showing the securing of the stanchions in fordeck area.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct test and have vessel ready for inspection of the hull structure, electrical, and machinery. Vessel was not prepared for annual inspection. Vessel is restricted from operating with passengers for hire until a satisfactory annual inspection is completed as required by 46 CFR 176.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
Resolution: Inspection Completed
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 April 2017 Resolved
Port and Stbd ventilation shutdowns for engine room are inoperable. Renew ventilation shutdowns to create vapor tight seal in space for fire suppression system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2017
Resolved 18 April 2017
Resolution: Verified ventilation shutdowns properly function to create vapor tight seal in engine space for fire suppression system.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 April 2017 Resolved
Make entire engine room space vapor tight for fixed fire suppression system in port and stbd engine space. Multiple holes found in the overhead and forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2017
Resolved 18 April 2017
Resolution: Operator used fire retardant expansion foam to seal holes and create vapor tight barrier in engine space.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 April 2017 Resolved
Passengers are restricted from using aft swim step ladder until the proper repairs are made to the following: cracked fiberglass stairs on the stbd transom, cracked fiberglass transom where swim step support detached, disconnected railing on port side and under wooden swim step.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Proper repairs made to the aft swim step and transom.
Engineering › Steering Gear System › Linkage
Issued 13 April 2017 Resolved
Witnessed excessive movement at the tiller arm connection to the hydraulic arm on the port and starboard rudder. Operator will disconnect for further inspection of linkage.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator removed linkage pins and discovered severe wastage. Linkage pins replaced in kind and found satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 13 April 2017 Resolved
Repair seven inch long cracked and softened passenger deck located starboard side, five feet forward of the doorway leading to the forward passenger deck.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Passenger deck repaired with epoxy fiberglass and reinforced with marine grade plywood; all sat.
Engineering › Fuel Oil Service System › Piping
Issued 13 April 2017 Resolved
Replace or renew severed grounding wire on the port and starboard fill pipe for the fuel tank.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Grounding wire on the port and starboard fill pipe for the fuel tank attached and found in good order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 April 2017 Resolved
Replace cracked flexible hose connected to the thru hull valve in the starboard hull used to provide sea water to the MSD tank.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Flexible hose replaced.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 13 April 2017 Resolved
Provide written weather limitations and in-water briefing instructions for the crew to comply with reduced manning for snorkel operations IAW Sector Hono CID work instruction 31.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Company provided written weather limitations and in-water safety brief instructions for crew.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2017 Resolved
Replace ring life buoy and water light battery with USCG approved ring life buoy and battery for water light.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Ring buoy and battery replaced with USCG approved type.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 April 2017 Resolved
A/C generator positive conductor ring terminal connection hole is larger than the nut used to fasten it. Replace the nut or ring terminal connection with appropriate size.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: A/C generator conductor connection and nut properly sized.
Electrical › Electric Generation Source (service) › Generator
Issued 13 April 2017 Resolved
Provide double hose clamps on generator exhaust discharge piping located in the port engine compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Double hose clamps found on generator exhaust discharge piping located in the port engine compartment.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 13 April 2017 Resolved
Provide over current protection IAW 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: AC circuit breaker replaced with QOU E84967 50 amp breaker, approved standards UL 489 and IEC-60947-2.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Replace all electrical terminal connections and provide covers for terminal connections in the port and starboard machinery space.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Electrical terminal strips and conductor connections were replaced in kind in the DC circuit, port and starboard side.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 13 April 2017 Resolved
Overcurrent protection fuse found severely corroded in the D/C circuit. Replace overcurrent protection IAW 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: DC circuit overcurrent protection, after the battery switch in port and starboard engine room, replaced with Ace Hardware 250 V a.c. Class RK5 cartridge fuse rated for 100 amps and an interupt rating of 200,000 amps.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2017 Resolved
Battery storage box located in the starboard machinery space found is constructed of wood. Wood rot found under the box and on both sides. Wood supports for the battery storage box found disconnected from the battery storage box due to wood rot.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fiberglass battery storage box contructed and found in sat condition.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 April 2017 Resolved
Flexible hoses on raw water cooling system for port and starboard main engine found with soft spots, kinks, cracks, and holes. Hose clamps fell off of flexible hoses when touched by hand. Replace raw water cooling hoses in kind for port and starboard main engines.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Operator replaced in kind the main engine cooling water flexible hoses on the port and starboard main engine.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 April 2017 Resolved
Port main engine exhaust flexible piping is kinked at the thru hull penetration due to poor support for the entire exhaust piping. Starboard main engine exhaust is supported by nylon straps previously used on lifejackets. Provide adequate support for exhaust piping on the port and starboard main engines.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Port and starboard main engine exhaust hose is adequately supported by metal supports.
Engineering › Fuel Oil Service System › Piping
Issued 13 April 2017 Resolved
Port main engine fuel delivery line found kinked just before the primary fuel filter in the port engine compartment. Replace fuel delivery line IAW 46 CFR 182.20-40.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fuel delivery line replaced with new piping. Replacement made in kind.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 April 2017 Resolved
Repair exhaust leak on the starboard main engine exhaust. Leak detected at the thru hull penetration.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Exhaust leak repaired. Double hose clamps were wasted and removed by operator. Operator replaced hose clamps in kind which stopped the leak of exhaust fumes in the engine room.
Construction/Loadline › Structures › Door
Issued 13 April 2017 Resolved
Repair door hinge to door providing access to port engine compartment found disconnected from the fiberglass it was bolted to.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator placed block of marine grade plywood under hinge to support bolts and fastened the hinge with new bolts; all sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 April 2017 Resolved
Remove oil and water in port and starboard machinery space bilge for inspection.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Bilge was found dry and inspected.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 13 April 2017 Resolved
All battery connections shall be made to the battery terminals with permanent connections.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Permanent connections made at battery terminals.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Secure all dead end wires in the engine compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Dead end wires secured in engine room.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 April 2017 Resolved
95 adult and 03 child lifejackets found unfit for service. Passenger count reduced to 45 adult and 11 child unitl replaced IAW 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: 95 adult and 03 child new lifejackets purchased by operator and placed into service.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 April 2017 Resolved
Repair inoperable visual auto bilge indicator for starboard steering compartment and port forward void.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Visual auto bilge indicator for starboard steering compartment and port forward void found satisfactory.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Properly secure electrical conduit piping in port steering compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Electrical conduit piping in port steering compartment found supported.
Fire Fighting › Fire Main › Condition
Issued 13 April 2017 Resolved
Fire pump piping located in the port hull found leaking at a pipe connection and at the manifold. Repair leaks to fire pump piping.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator repaired piping. Piping tested under pressure of the fire pump and found satisfactory.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2017 Resolved
Electrical junction box in the port fuel tank compartment found corroded. Replace junction box. 46 CFR 183.05-50(b)
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Electrical junction box in the port fuel tank compartment found replaced in kind.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 April 2017 Resolved
Secure fuel fill delivery flexible hose line on the port side fuel tank with double hose clamps.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fuel fill delivery flexible hose line on the port side fuel tank found with double clamps.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 April 2017 Resolved
Lifejacket placard found onboard is in Japanese. Provide a lifejacket placard in languages for all passengers carried.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Lifejacket placard in Japanese and English found onboard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 13 April 2017 Resolved
Emergency instructions do not align with equipment carried onboard. Provide emergency instructions for equipment carried on the vessel.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: New emergency instructions found onboard and found satisfactory.
Navigation › Piloting/Steering › Marine Charts
Issued 13 April 2017 Resolved
Provide current marine charts and publications for operating area.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Current marine charts found onboard.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2017 Resolved
Approved vessel plans indicate the vessel is outfitted with two generator and no battery chargers. Vessel currently has one generator and two battery chargers. Provide electrical drawings for A/C and D/C circuits onboard.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 July 2017
Resolution: Electrical drawing submitted with updated items included.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 March 2016 Resolved
Valid original not available. Provide prior to carrying passengers
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 March 2016 Resolved
9 child-sized life jackets unsat. Passenger count restricted to 5 persons under 90 pounds
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2016
Fire Fighting › Fire Hoses › Material
Issued 11 March 2016 Resolved
Provide appropriate hose and nozzle per regulations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 21 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 11 March 2016 Resolved
Provide a report from a third-party surveyor on condition of port hull prior to operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 January 2016 Resolved
Repair or replace electrical wires and cables damaged in engine room and void spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Construction/Loadline › Hull › Side Shell
Issued 13 January 2016 Resolved
Repair external hull structure areas in which delamination was found.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 January 2016 Resolved
Replace port side shaft and conduct proper alignment test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 January 2016 Resolved
Reomove and replace rotted transversal wood frames in stbd void #2 and port void #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 January 2016 Resolved
Remove and replace engine exhaust pipe insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 January 2016 Resolved
Remove oil soaked lagging and repair excessive oil leak from port side steering gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 January 2016 Resolved
Remove and replace insulation located in overhead engine room spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 January 2016 Resolved
Remove and replace engine exhaust pipe insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 April 2009 Resolved
Provide updated light list and Notice to Mariners for chart.
Due 11 May 2009
Resolved 11 May 2009
Resolution: Verified vessel had updated Light List and NTM.
Documentation › Logs/Records › Logbook (official)
Issued 27 April 2009 Resolved
Provide logbook with recorded drills.
Due 11 May 2009
Resolved 11 May 2009
Resolution: Verified that vessel provided logbook and started logging drills.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2009 Resolved
Provide current Safety Radiotelepathy Certificate.
Due 11 May 2009
Resolved 11 May 2009
Resolution: Verified current FCC Safety Radiotelepathy Certificate.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2009 Resolved
Install new battery in lifering float light and log date installed.
Due 11 May 2009
Resolved 11 May 2009
Resolution: Verified that vessel replaced battery and logged the date.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2009 Resolved
Provide guards on rotating gear near fire pump lever for both port and starboard fire pump.
Due 11 May 2009
Resolved 2 June 2009
Resolution: Verified adequate guard for rotating gear.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 27 April 2009 Resolved
Prove proper operation of generator.
Due 11 May 2009
Resolved 23 April 2010
Resolution: Generator is on board and working.
Personnel › Training › First Aid/CPR
Issued 27 April 2009 Resolved
Provide CPR Cards for 50% of crew.
Due 11 May 2009
Resolved 28 May 2009
Resolution: Received faxed copies of all crew members CPR and First Aid cards.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 April 2009 Resolved
Conduct annual DAPI Audit.
Due 11 May 2009
Resolved 29 May 2009
Resolution: Completed annual DAPI Audit.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 24 April 2009 Resolved
Provide proof arrangements for testing for serious marine incident for drug and alcohol testing program.
Due 29 June 2009
Resolved 8 June 2009
Resolution: Received fax stating the arrangement with Reliable Drug Testing Services in case of a serious marine incident.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 24 April 2009 Resolved
Provide proof of arrangements for testing (drug/alcohol) for reasonable cause.
Due 29 June 2009
Resolved 8 June 2009
Resolution: Received fax stating the arrangement with Reliable Drug Testing Services in case of reasonable cause.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 21 April 2009 Resolved
Provide proof of normal starting operation of both #1 and #2 main diesel engine.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Resolution: Observed both main diesel engines started normally, after batteries had been replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 31 March 2009 Resolved
In starboard engine room, inboard side, provide plans/specifications for size, type, and location of materials used in frame replacement.
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Received plans submittal. Please see document "Engine Room Repair Plan 2009 DD"
Construction/Loadline › Hull › Transverse Frame
Issued 31 March 2009 Resolved
In starboard engine room, inboard side, remove (02) partially replaced frames (#3 and #4 from aft bulkhead) and renew each with one solid frame.
Action required: 705 - Other - as specified
Resolved 2 April 2009
Resolution: Verified that repairs were maded IAW submitted plans. Please see document Engine Room Repair Plan 2009 DD for specifics.
Construction/Loadline › Structures › Superstructure
Issued 31 March 2009 Resolved
Remove passenger railing on bow for visual inspection of rail post mounts/bedding.
Action required: 705 - Other - as specified
Resolved 2 April 2009
Resolution: Observed hull with removed railing, no damage found. Discussed how to reattach railing, decided on prior used bolt holes where filled with dowels and sealed with epoxy, and the rails were secured in new bolt holes.
Construction/Loadline › Hull › Hull Plating
Issued 31 March 2009 Resolved
Grind to good/solid foam and dry the following areas for further inspection: port hull approximately 2 feet forward of keel amidships, through hull penetration in port hull forward, 2 spots on starboard hull inboard amidships, large area from starboard inboard to keel to starboard outboard- 1/3 from bow, 2 large areas starboard inboard bow, and 1 small port starboard bow outboard side.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: Verified that ground to good foam and reglassed.
Construction/Loadline › Hull › Hull Plating
Issued 31 March 2009 Resolved
Ensure all hull repairs preparations are beveled to a 12:1 ratio and inspected by Marine Inspector prior to commencing repairs.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: Verified that all repairs ground to an approximate 12:1 ratio before reglassed
Construction/Loadline › Structures › Manhole
Issued 31 March 2009 Resolved
Renew port lazarette hatch.
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Verified that hatch was renewed in kind.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 27 March 2009 Resolved
Renew main engine exhaust lagging both port and starboard.
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Verified that renewed main engine lagging.
Construction/Loadline › Hull › Transverse Frame
Issued 27 March 2009 Resolved
Grind back the following identified areas of wood rot to good wood and submit repair proposals for: starboard lazarette forward bulkhead- dry rot around bolts, all rotted frames inboard side of starboard engine room, starboard engine room, second and third frame from forward outboard side, starboard engine room forward overhead beam outboard. Repair in accordance with approved plan.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: Verified that ground back to go wood and preserved.
Construction/Loadline › Hull › Transverse Frame
Issued 27 March 2009 Resolved
Grind back the following identified areas of wood rot to good wood and submit repair proposals for: starboard engine room second from forward overhead beam, inboard side, void in front of engine room, starboard side, forward overhead and deck rot including deck support, dry rot around screws in starboard fuel tank compartment at forward overhead beam. Repair in accordance with approved plan.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Verified that ground to good wood and preserved.
Construction/Loadline › Hull › Transverse Frame
Issued 27 March 2009 Resolved
Grind back the following identified areas of wood rot to good wood and submit repair proposals for: line locker hatch hinge seats, and hatch cover starboard side, second void aft from bow starboard side ring frame in the vicinity of the keel and forward bulkhead beam, starboard forepeak, two aft overhead frames. Repair in accordance with approved plan.
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Verified that ground to good wood and preserved.
Construction/Loadline › Hull › Hull Plating
Issued 27 March 2009 Resolved
Grind crack on port forepeak deck for further inspection.
Action required: 705 - Other - as specified
Resolved 2 April 2009
Resolution: Verified repairs completed on port forepeak deck.
Construction/Loadline › Structures › Manhole
Issued 27 March 2009 Resolved
Starboard side, third void aft from bow, renew gasket, provide means of dogging hatch down, and attach line from vessel to hatch cover.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Resolution: Verified that renewed gasket, provided crews as means to dog hatch down, and attached line from vessel to hatch cover.
Construction/Loadline › Hull › Stool
Issued 26 March 2009 Resolved
Replace one identified bad spool piece and renew cracked pipe on check valve. Replace 1 identified bad ball valve and prove proper operation of all valves.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Verified replaced in kind and master proved proper operation of ball valve.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2009 Resolved
Grind back to good FRP, scarf, and renew the following identified areas: swim step starboard outboard, 9 previously identified areas on inboard starboard hull, and 5 previously identified areas on outboard port hull. For all areas, prepare area and submit plan for approval prior to renewing the fiberglass and completing repairs
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Observed repairs at multiple stages during the repair process. Verified completion of repairs.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2009 Resolved
Grind back to good FRP, scarf, and renew the following identified areas: blisters behind 2nd ground out area starboard hull inboard, port inboard amidships, and 5-6 areas of water intrusion identified along port keel. For all areas, preparation area and submit plans for approval prior to renewing then fiberglass and completing repairs.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Observed repairs at multiple stages during the repair process. Verified completion of repairs.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2009 Resolved
Grind back to good FRP, scarf, and renew the following identified areas: delamination lower outboard starboard hull, beneath hull and inboard area blisters above large leak from foam starboard. For all areas, preparation area and submit plans for approval prior to renewing then fiberglass and completing repairs.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Observed repairs at multiple stages during the repair process. Verified completion of repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 March 2009 Resolved
Repair cracks identified in outboard railing by starboard swim step.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified repair completion, consisted of grinding down to good wood.
Construction/Loadline › Penetrations › Bottom Plug Seat
Issued 26 March 2009 Resolved
Remove deck drain inboard starboard stringer (by starboard hull) and rebed.
Action required: 705 - Other - as specified
Resolved 2 April 2009
Resolution: Observed completed repair of rebedding the deck drain.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2009 Resolved
Clean up all identified areas of exposed mat woven and re-epoxy.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Observed repairs at multiple stages during the repair process. Verified completion of repairs.
Engineering › Steering Gear System › Rudder
Issued 26 March 2009 Resolved
Re-glass rudder post attachments. Grind back to good FRP and make available for inspection before re-glassing.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Verified that crew ground to good fiberglass, repaired water intrusion, and reglassed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 March 2009 Resolved
Remove and treat angel hair on the rudder support in port lazarette.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and glassed over area.
Construction/Loadline › Hull › Stringer
Issued 26 March 2009 Resolved
Treat rot/termite damage in port lazarette aft stringer in overhead- remove all bad wood and treat.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and glassed over area.
Construction/Loadline › Hull › Side Shell
Issued 26 March 2009 Resolved
Outboard in port lazarette, grind back previous repair that is delaminating and re-fiberglass. Make available for inspection prior to commencing repairs after removal of delamination.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and glassed over area.
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 March 2009 Resolved
Treat rot in aft two overhead frames in port engine room.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and preserved.
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2009 Resolved
Treat rot in overhead at aft bulkhead inboard corner in port engine room.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and preserved.
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2009 Resolved
Treat inboard aft two frames and submit plans for renewal of third frame from aft bulkhead inboard side in port engine room. conduct repairs IAW plans.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified repair, which was treatment only and not replacement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 March 2009 Resolved
Clean up and properly support wiring throughout the vessel
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Verified that bundled wiring and supported wiring throughout vessel.
Construction/Loadline › Hull › Stringer
Issued 26 March 2009 Resolved
Void in front of port engine room space- treat rot in inboard stringer.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground down to good wood and preserved.
Construction/Loadline › Penetrations › Bottom Plug Seat
Issued 26 March 2009 Resolved
Grind saturated fiberglass out from around thru hull penetration in port fuel tank space. Prep and submit plans for repair.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Verified that ground to good fiberglass and refiberglassed in thru hull penetration.
Construction/Loadline › Penetrations › Gasket
Issued 26 March 2009 Resolved
Renew gasket on hatch port side third void aft from bow.
Action required: 705 - Other - as specified
Resolved 21 April 2009
Resolution: Verified that gasket was renewed in kind.
Construction/Loadline › Structures › Manhole
Issued 26 March 2009 Resolved
Renew port line locker hatch cover and aft hinge connection point.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Verified that renewed hatch cover in kind and resecured aft hinge to vessel.
Engineering › Diesel Engine (auxiliary) › Gear, Timing
Issued 26 March 2009 Resolved
Vessel must conduct underway operational tests (engines, steering, and generator) prior to completion of credit drydock exam.
Action required: 705 - Other - as specified
Resolved 27 April 2009
Resolution: Went underway with vessel, proved proper operation on engines and steering. Generator was written as new deficiency and given 2 weeks to prove proper operation.
Engineering › Fuel Oil Service System › Filter
Issued 16 January 2008 Resolved
STBD MDE stalling
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Resolution: Changed fuel filter
Lifesaving › Lifebuoys › Serviceable
Issued 16 January 2008 Resolved
Lifering need replacement
Action required: 705 - Other - as specified
Resolved 16 January 2008
Resolution: replaced life ring
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 24 May 2007 Resolved
Missing two fire extinguishers, that are being serviced. Provide two BII extinguishers IAW 46 CFR 181-30-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 May 2007 Resolved
34 adult and 1 Child size life jackets have deteriorated retro reflective material. Renew reflective tape IAW 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 25 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 May 2007 Resolved
13 Adult size life jackets were deteriorated due to age. Provide replacement jackets IAW 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 25 May 2007
Resolution: Purchased 15 brand new jackets.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 May 2007 Resolved
Vessel required to have 3 deckhands for operations. Only 1 deckhand was available at time of annual inspection. Provide 3 qualified deckhands to complete emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: 3 deckhands that are enrolled in the drug and alcohol program were available to conduct drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 May 2007 Resolved
Unable to complete annual inspection due to insufficient fire fighting equipment, and missing crew members. Annual inspections is beyond 90 days from anniversary date. Vessel must complete 4th annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Completed drills and inspection.
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 May 2007 Resolved
Both Potable water tanks are dirty with sediment and debris in the bottom. Make both tanks clean and sanitary as required 46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 2 July 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 May 2007 Resolved
Fresh water tanks have no covers, vent pipes and inadequate fill lines. Make fresh water tanks as per original drawings to include installation of access covers, vent and fill pipes.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 2 July 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 April 2007 Resolved
Conduct annual reinspection. Anniversary date is January 24th. 90 day window expiration date was April 24th.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 17 March 2006 Resolved
Properly mount fixed fire system in port engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2006
Resolved 17 March 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 March 2006 Resolved
Repair/Replace raw water overboard main hose on starboard engine.
Condition: Improper/Lack of Maintenance
Due 5 April 2006
Resolved 2 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 17 March 2006 Resolved
Repair/Replace raw water pump on starboard engine.
Condition: Improper/Lack of Maintenance
Due 5 April 2006
Resolved 2 April 2009
Engineering › Bilge Water Management System › Not Operational
Issued 27 September 2005 Resolved
Make all audible bilge/high water alarms operable to the satisfaction of the OCMI prior to operations with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2005
Resolution: Provided operable audible bilge/high water alarms to the satisfaction of the OCMI.
Stability › Intact Righting Energy › General
Issued 13 April 2005 Resolved
Provide rigging report prior to carrying passengers. Found fractures in mast rigging.
Condition: Improper/Lack of Maintenance
Due 13 April 2005
Resolved 21 July 2005
Engineering › Bilge Water Management System › Piping
Issued 13 April 2005 Resolved
Prove proper operation of fixed bilge system prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 13 April 2005
Resolved 21 July 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 April 2005 Resolved
Repair deck railing throughout vessel prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 20 April 2005
Resolved 21 July 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 13 April 2005 Resolved
Fumigate vessel prior to dry dock or next inspection.
Condition: Improper/Lack of Maintenance
Due 13 April 2005
Resolved 21 July 2005
Construction/Loadline › Structures › Scuttle
Issued 13 April 2005 Resolved
Prove proper operation of all quick acting scuttles prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 13 April 2005
Resolved 21 July 2005
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2005 Resolved
Provide plan approval for alterations to main deck above engine spaces.
Condition: Placed in Improper Service
Due 13 April 2005
Resolved 21 July 2005
Construction/Loadline › Structures › Superstructure
Issued 13 April 2005 Resolved
Provide survey report prior to dry dock inspection.
Condition: Improper/Lack of Maintenance
Due 13 April 2005
Resolved 21 July 2005
Engineering › Diesel Engine (auxiliary)
Issued 26 January 2004 Resolved
Install guard over generator belt and flywheel.
Due 26 February 2004
Resolved 3 February 2004
Fire Fighting › Fire Pumps
Issued 26 January 2004 Resolved
Repair leaks on port side fire pump.
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Install plugs on racor fuel filters for both port and stbd main engines.
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Make permanent repairs to port main engine exhaust leaks. LEGACY COMPONENT DESC: Piping (exhaust)
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Insulate exhaust piping in port and stbd engine rooms. LEGACY COMPONENT DESC: Piping (exhaust)
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Repair crimped hose on port side exhaust cooling water injection line. LEGACY COMPONENT DESC: Piping (exhaust)
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Insure all hoses connected to thru hull fittings are double clamped.
Due 26 February 2004
Resolved 3 February 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004 Resolved
Repair broken pipe hanger on stbd side exhaust cooling water injection line.
Due 26 February 2004
Resolved 3 February 2004
Electrical › Electrical Distribution System (service)
Issued 26 January 2004 Resolved
Close all open holes on pilot house instrument panel.
Due 26 February 2004
Resolved 3 February 2004
Operations/Management › Drills/Instruction
Issued 26 January 2004 Resolved
Provide evidence that drills are being conducted.
Due 26 February 2004
Resolved 3 February 2004
Electrical › Lighting (service)
Issued 26 January 2004 Resolved
Prove navigation lights.
Due 26 February 2004
Resolved 3 February 2004
Fire Fighting › Fire Main
Issued 26 January 2004 Resolved
Repair leaking fire main/bilge system piping in comp. forward of engine room in the stbd side hull .
Due 26 February 2004
Resolved 3 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 26 January 2004 Resolved
Prove deck railing port side aft. LEGACY COMPONENT DESC: Deck Rail
Due 26 February 2004
Resolved 3 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 January 2004 Resolved
Replace one child PFD. LEGACY COMPONENT DESC: Condition
Due 26 February 2004
Resolved 3 February 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 January 2004 Resolved
Properly mark engine room closure vents. LEGACY COMPONENT DESC: Operating Controls
Due 26 February 2004
Resolved 3 February 2004
Operations/Management › Drills/Instruction
Issued 26 January 2004 Resolved
Complete U/W Drills.
Due 26 February 2004
Resolved 3 February 2004
Construction/Loadline › Hull
Issued 1 April 2003 Resolved
Repair as original rotten wood in the port NR.1 compartment aft of WTH. LEGACY COMPONENT DESC: Under Deck Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Hull
Issued 1 April 2003 Resolved
Repair as original rotten wood in the port NR.2 compartment forward of the WTH. LEGACY COMPONENT DESC: Under Deck Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Hull › Stiffener
Issued 1 April 2003 Resolved
Repair as original rotten wood in the port NR.3 compartment, inboard side NR.1 vertical stiffener.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 April 2003 Resolved
Fumigate vessel for roaches and bugs. LEGACY COMPONENT DESC: Fumigate vessel for roaches and bugs
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Hull
Issued 1 April 2003 Resolved
Repair as original rotten wood in the starboard NR.2 compartment at the NR.2 transverse deck frame. LEGACY COMPONENT DESC: Under deck transverse frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Structures
Issued 1 April 2003 Resolved
Renew rotten deck around the starboard steering room hatch cover. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Structures › Scuttle
Issued 1 April 2003 Resolved
Seal/Caulk port steering gear hatch cover at deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Construction/Loadline › Hull › Bottom Plating
Issued 1 April 2003 Resolved
Grind 07 blistered areas on the port hull and prep. for visual inspection.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Resolution: No delamination or soft spots detected after further inspection. Areas affected were filled w/ epoxy resin.
Construction/Loadline › Hull › Transverse Frame
Issued 1 April 2003 Resolved
Repair as original the NR. 12 transverse deck frame under the wing and repair rotten wood around deck drain holes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 18 April 2003
Engineering › Steering Gear System › Linkage
Issued 1 April 2003 Resolved
Renew/Repair wasted and holed steering tie rod and adjust to prevent rubbing on the hull and frames.
Condition: Unknown
Due 1 May 2003
Resolved 18 April 2003
Resolution: Installed new tie rod. Witnessed operational test of the steering system, all sat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 30 January 2002 Resolved
Show proper operation of tachometer for port main deisel engine in accordance with 46 CFR 182.410. LEGACY COMPONENT DESC: Tachometer
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 February 2002
Resolved 24 January 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 30 January 2002 Resolved
Provide proper first aid kit in accordance with 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2002
Resolved 24 January 2003
Lifesaving
Issued 26 January 2001 Resolved
Replace worn lower mast stay starboard amidships IAW 46 CFR 177.330.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Fire Fighting
Issued 26 January 2001 Resolved
Demonstrate operation of fire and smoke detection system IAW 46 CFR 176.810(a)(7).
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Construction/Loadline
Issued 26 January 2001 Resolved
Crop and renew as original dry rotted wood in deck above port engine compartment. Area is appprox 50" X 25" total and is on either side of frame aft of engine block.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Fire Fighting
Issued 26 January 2001 Resolved
Make deck above port engine compartment vapor tight IAW 46 CFR 182.465(h).
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Accommodation/Occupational Safety
Issued 26 January 2001 Resolved
Replace badly rusted hot water heater in starboard engine compartment IAW 46 CFR 176.818.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Accommodation/Occupational Safety
Issued 26 January 2001 Resolved
Provide ventilation for port and starboard sewage tanks IAW 33 CFR 159.95.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Fire Fighting
Issued 26 January 2000 Resolved
Seal small hole in deck above port engine compartment iaw 46CFR 182.465._x001C_
Condition: Unknown
Due 9 February 2000
Resolved 17 February 2000
Navigation
Issued 26 January 2000 Resolved
Provide tide table/calendar iaw 46CFR 184.420.
Condition: Unknown
Due 9 February 2000
Resolved 17 February 2000
Navigation
Issued 26 January 2000 Resolved
Provide exterior mount for ship's bell iaw COLREGS.
Condition: Unknown
Due 9 February 2000
Resolved 17 February 2000
Engineering
Issued 26 January 2000 Resolved
Prove proper operation of tachometer for stbd engine iaw 46CFR 182.410(b).
Condition: Unknown
Due 9 February 2000
Resolved 17 February 2000
Navigation
Issued 7 April 1999 Resolved
Effect permanent repairs and prove proper operation of port hydraulic steering ram.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 7 April 1999 Resolved
Repair as original the rotted under deck beam just aft of the manhole in the starboard lazerette.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Construction/Loadline
Issued 7 April 1999 Resolved
Complete installation & prove proper operation of high bilge level alarm system.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Fire Fighting
Issued 7 April 1999 Resolved
Complete installation of fixed fire extinguishing system for both engine rooms.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Engineering
Issued 7 April 1999 Resolved
Provide means to secure ventilation to spaces protected by the fixed fire extinguishing systems.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Documentation
Issued 28 January 1998 Resolved
Post current FCC Safety Radio Certificate for VHF radio.
Condition: Unknown
Due 28 February 1998
Resolved 30 January 1998
Fire Fighting
Issued 29 January 1997 Resolved
Service 2 B-II portable fire extinguishers to check gauge.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Lifesaving
Issued 29 January 1997 Resolved
Replace snap hook on 1 child size PFD. _x001C_
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Lifesaving
Issued 29 January 1997 Resolved
Replace snap hooks on 4 adult PFDs.
Condition: Unknown
Due 29 January 1997
Resolved 29 January 1997
Construction/Loadline
Issued 24 January 1996 Resolved
Provide handles for all sea valves. Presently, two valves are missing their handles.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Engineering
Issued 24 January 1996 Resolved
Make permanent repairs to holes in both main engine exhaust lines.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Engineering
Issued 24 January 1996 Resolved
Remove all oil from both machinery space bilges and make permanent repairs to any oil leaks on the diesel engines.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Engineering
Issued 24 January 1996 Resolved
Remove the non-metallic flexible fuel hoses from the port fuel system afterthe bulkhead penetration and prior to the fuel filter. Coast Guard approved non-metallic hose or a loop of tubing main be used between the fuel filter and the engines.
Condition: Unknown
Due 24 January 1996
Resolved 24 January 1996
Electrical
Issued 24 January 1996 Resolved
Install the missing belt drive protective guard located on the front of thegenerator engine.
Condition: Unknown
Due 15 February 1996
Resolved 20 February 1996
Construction/Loadline
Issued 24 January 1996 Resolved
Make permannet repairs to the bilge system piping in the starboard engine room in way of the broken brazed 90 degree fitting at the forward bulkhead penetration.
Condition: Unknown
Due 15 February 1996
Resolved 20 February 1996
Construction/Loadline
Issued 26 January 1995 Resolved
REPLACE BILGE LINE CLAMP IN STARBOARD FUEL TANK COMPARTMENT.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Construction/Loadline
Issued 26 January 1995 Resolved
REPAIR OR REPLACE BILGE SUCTION STRAINER IN STARBOARD STORAGE COMPARTMENT.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Navigation
Issued 26 January 1995 Resolved
REPLACE HYDRAULIC STEERING HOSE CLAMP IN STARBOARD ENGINE COMPARTMENT.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Engineering
Issued 26 January 1995 Resolved
RENEW OR REPAIR ENGINE FUEL SHUTOFF CABLE LOCATED IN STARBOARD FUEL TANK COMPARTMENT.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Construction/Loadline
Issued 28 January 1994 Resolved
REPLACE MISSING LETTERS FOR THE HULL IDENTIFICATION NUMBERS LOCATED AT THE AFT END OF THE PILOT HOUSE.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Fire Fighting
Issued 28 January 1994 Resolved
PRIOR TO CARRYING PASSENGERS, DEMONSTRATE PROPER OPERATION OF BOTH FIRE PUMPS.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Electrical
Issued 28 January 1994 Resolved
REMOVE UNNECESSARY LABELS FOR NON-EXISTANT ELECTRICAL SYSTEMS LOCATED ON THE ELECTRIC CONTROL CONSOLE IN THE PILOT HOUSE.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Lifesaving
Issued 28 January 1994 Resolved
ADD AN ADDITIONAL PA SPEAKER TO THE MAIN PASSENGER SEATING AREA.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Engineering
Issued 28 January 1994 Resolved
REPLACE (4) BROKEN GAUGE INDICATORS AT THE PILOT HOUSE CONTROL STATION._x001C_ (2) 12 VOLT GAUGES, (1) TACHOMETER FOR THE STBD MAIN, & (1) AMP METER FOR THE STBD MAIN.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 28 January 1994 Resolved
TIGHTEN ALL WEATHER DECK HATCHES AND PROVE WATER TIGHT BY HOSE TESTING IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Engineering
Issued 28 January 1994 Resolved
PROPERLY LABEL THE FUEL SHUT OFF VALVES AS PERSCRIBED BY 46 CFR 185.30-20.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Construction/Loadline
Issued 28 January 1994 Resolved
PRIOR TO CARRYING PASSENGERS, DEMONSTRATE PROPER OPERATION OF THE BILGE SUCTION SYSTEMS FOR BOTH HULLS. PROVE OPERABLE BY DRAINING WATER FROM THE AFT VOIDS, THE FWD VOIDS, AND THE VOIDS JUST FORWARD OF THE ENGINE ROOM. EACH HULL TO BE DRAINED USING THE PUMP DEDICATED FOR EACH HULL.
Condition: Unknown
Due 12 February 1994
Resolved 31 January 1994
Navigation
Issued 1 February 1993 Resolved
SECURE BOTH ENDS OF THE 2"x4" SUPPORT BEAM FOR THE STEERING LINKAGE CROSS BAR, PORT SIDE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 1 February 1993 Resolved
PROPERLY LABEL BOTH BILGE SUCTION MANIFOLDS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 1 February 1993 Resolved
RAISE FLOAT SWITCHES FOR ELECTRIC BILGE PUMPS IN EACH ENGINE ROOM, TO REDUCE POSSIBILITY OF ACCIDENTAL OIL DISHARGE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Fire Fighting
Issued 1 February 1993 Resolved
PROPERLY LABEL BOTH FIRE STATIONS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 1 February 1993 Resolved
PERMANENTLY SEAL HOLES IN #4 WATERTIGHT HATCH, STARBOARD SIDE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 1 February 1993 Resolved
DEMONSTRATE PROPER OPERATION AND CHALK TEST #2 WATERTIGHT HATCH AND #6 WATERTIGHT HATCH, BOTH STBD SIDE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Documentation
Issued 1 February 1993 Resolved
PROVIDE PROOF THAT VESSEL'S CREW COMPLIES WITH THE RANDOM DRUG TESTING PROCEDURES. THIS ITEM CAN BE COMPLETED BY FAX TO OUR OFFICE [phone withheld].
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Engineering
Issued 1 February 1993 Resolved
INSTALL 30x30 CORROSION RESISTANT WIRE FLAME SCREENS (REMOVABLE) FOR BOTH FUEL TANKS.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Documentation
Issued 1 February 1993 Resolved
PROVIDE A MARPOL V PLACARD.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Documentation
Issued 1 February 1993 Resolved
PROVIDE A WASTE MANAGEMENT PLAN DESIGNATING A PERSON IN CHARGE.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Accommodation/Occupational Safety
Issued 25 October 1991 Resolved
REPLACE STANCHIONS AND RAILINGS ON FOREDECK PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Construction/Loadline
Issued 14 June 1991 Resolved
RENEW HANDLES FOR SEA VALVES IN PORT AND STBD STORAGE COMPARTMENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Engineering
Issued 30 January 1991 Resolved
REPAIR FUEL SHUT-OFF VALVE TO PORT INDEPENDENT GENERATOR.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Accommodation/Occupational Safety
Issued 30 January 1991 Resolved
REPAIR LEAKY HOSE TO PORT WATER ACCUMULATOR.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Navigation
Issued 30 January 1991 Resolved
RENEW HYDRAULIC RAM PIN FOR STARBOARD RUDDER.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Electrical
Issued 30 January 1991 Resolved
REMOVE LOOSE ELECTRICAL WIRING AND PLUG ENDS TO ELECTRICAL WIRING IN PORT_x001C_ ENGINE ROOM.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Engineering
Issued 30 January 1991 Resolved
REPAIR INSULATION AT MAIN ENGINE EXHAUST MANIFOLD FLANGE IN PORT ENGINE_x001C_ ROOM.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Lifesaving
Issued 30 January 1991 Resolved
ADD A 60 FT LIFELINE TO RING BUOY WITH WATER LIGHT.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Construction/Loadline
Issued 30 January 1991 Resolved
PERMANENTLY AFFIX LADDER IN MAIN CABIN, PORT STORAGE COMPARTMENT.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Construction/Loadline
Issued 30 January 1991 Resolved
PERMANENTLY AFFIX LADDER IN MAIN CABIN, STBD STORAGE COMPARTMENT.
Condition: Unknown
Due 30 January 1991
Resolved 30 January 1991
Engineering
Issued 6 February 1989 Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF BOTH FUEL TANK REMOTE SHUT OFFS AND INSTALL A REMOTE SHUT OFF FOR THE GENERATOR FULE SUPPLY LINE AT THE FUEL TANK SUPPLY VALVE.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Engineering
Issued 6 February 1989 Resolved
PROVIDE FLAME SHIELDS ON BOTH RACOR FUEL FILTERS AND INSTALL COAST GUARD APPROVED FLEXIBLE FUEL HOSES ON THE GENERATOR FUEL SUPPLY LINE.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Lifesaving
Issued 6 February 1989 Resolved
REPLACE ALL DEFECTIVE REFLECTIVE TAPE ON LIFE JACKETS.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Navigation
Issued 6 February 1989 Resolved
PROVIDE AND MAINTAIN ONBOARD COPIES OF SUBCHAPTER "T", RULES OF THE ROAD, AND LIGHT LIST, TIDE AND CURRENT TABLES AND COAST PILOT FOR KANEOHE BAY.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Navigation
Issued 6 February 1989 Resolved
MAKE PERMANENT REPAIRS TO THE VHF RADIO ANTENNA AND OR POWER SUPPLY AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Lifesaving
Issued 6 February 1989 Resolved
RENEW WORN GRAB LINE ON THE PILOT HOUSE LIFE RING.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Fire Fighting
Issued 6 February 1989 Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION TO BOTH BILGE/FIRE PUMPS.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Navigation
Issued 6 February 1989 Resolved
REPAIR AND PROVE OPERATION OF THE VLS'S HORN.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Navigation
Issued 6 February 1989 Resolved
EXTEND STERN LIGHT PASSED THE ANGLE BAR TO PROVIDE PROPER VISIBILITY OF THELIGHT.
Condition: Unknown
Due 6 February 1989
Resolved 6 February 1989
Construction/Loadline
Issued 29 January 1988 Resolved
PROVE DECK HATCH COVERS LOCATED FORWARD AND AFT PART OF VESSEL ARE WATER- TIGHT.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Engineering
Issued 29 January 1988 Resolved
DEMONSTRATE PROPER OPERATION OF THE STARBOARD EMERGENCY FUEL SHUT-OFF CONTROL VALVE.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Engineering
Issued 29 January 1988 Resolved
DEMONSTRATE PROPER OPERATION OF THE BILGE SYSTEM IN THE AFT COMPARTMENTS.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Documentation
Issued 29 January 1988 Resolved
PROVIDE A COPY OF CURRENT FCC (FORM 824) CERTIFICATE ON BOARD THE VESSEL.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Unknown
Issued 20 February 1987 Resolved
MAKE PERMANENT REPAIRS TO PORT HULL IN WAY OF OUTBOARD STERN AREA AT NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Unknown
Issued 20 February 1987 Resolved
PROVIDE AND PLACE ON BOARD 2 ADDITIONAL CHILD'S PERSONAL FLOTATION DEVICES.UNTIL THIS ITEM IS COMPLETE, THE NUMBER OF CHILDREN AUTHORIZED TO BE CARRIED IS LIMITED TO 12 TOTAL.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Unknown
Issued 20 February 1987 Resolved
REPAIR OR REPLACE WIRE CONNECTION FOR THE FUEL LEVEL INDICATOR CONNECTION AT THE PORT FUEL TANK.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Unknown
Issued 20 February 1987 Resolved
REPLACE OR REPAIR STERN LIGHT AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 20 February 1987
Resolved 20 February 1987
Unknown
Issued 23 May 1986 Resolved
PROVIDE RAILS AROUND PERIPHERY OF FORWARD DECK.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Unknown
Issued 23 May 1986 Resolved
PROVIDE RUNNING LIGHTS IN ACCORDANCE WITH CURRENT NAVIGATION RULES.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Unknown
Issued 23 May 1986 Resolved
PROVIDE TWO 50-FT. LENGTHS OF 5/8" MINIMUM DIAMETER HOSE AND SUITABLE BRONZE NOZZLE FOR FIRE STATIONS AND MARK ACCORDINGLY.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Unknown
Issued 23 May 1986 Resolved
ATTACH 60 FEET OF LINE TO RING BUOY.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Unknown
Issued 23 May 1986 Resolved
SUBMIT STRUCTURAL PLANS FOR FORWARD DECK ALTERATIONS BETWEEN HULLS.
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Accommodation/Occupational Safety
Issued 25 February 1985 Resolved
AFT DECK FLUSH DECK STRAINERS TO BE COVERED TO PREVENT A TRIPPING HAZARD.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Fire Fighting
Issued 25 February 1985 Resolved
FIRE AND BILGE SYSTEMS MUST COMPLY WITH 46 CFR 182.40-5 METALLIC PIPING MATERIALS.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Electrical
Issued 25 February 1985 Resolved
PROVIDE VESSEL WITH U.L. APPROVED JUNCTION BOXES. PLASTIC BOXES ARE NOT APPROVED.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Engineering
Issued 25 February 1985 Resolved
PROPERLY SECURE ENGINE EXHAUST AND GENERATOR EXHAUST LINES.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Electrical
Issued 25 February 1985 Resolved
INSTALL RIGID SEAWATER SUCTION PIPING FOR GENERATOR.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Unknown
Issued 25 February 1985 Resolved
STARBOARD FUEL OIL SPACE PROPERLY SECURE PIPING.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Electrical
Issued 25 February 1985 Resolved
PROVIDE COVERS FOR MISSING LIGHTING FIXTURES.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Lifesaving
Issued 25 February 1985 Resolved
REPAIR OR REPLACE 4 BUOYANT APPARATUS.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Lifesaving
Issued 25 February 1985 Resolved
INSTALL FLOAT FREE LINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Fire Fighting
Issued 25 February 1985 Resolved
PROVIDE MARINE TYPE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985

Casualty record · 3

27 March 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2033466
21 February 2012Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 4249356
15 September 2013Routine · role: Involved in a Marine Casualty · activity 4717497
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.