MAURY USCG vessel records
← All vessels

ONO MANA

Built
1980
Last inspected
10 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 October 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTD4370
Flag
UNITED STATES
Maury page id
psix-53823

Documentation record

Registered dimensions (L × B × D)62.0 ft × 31.0 ft × 6.0 ft
Registered tonnagegross 87 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHONOLULU · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
82 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 79 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

10 October 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8254206
27 November 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8038371
21 October 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8016313
19 July 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7962394
21 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7820935
18 May 2023 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7681862
25 August 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7537755
7 June 2022 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7474029
21 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082054
1 June 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7093782
9 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6711332
30 May 2019 Administrative Inspection · In-Service Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6676169
19 January 2018 DAPI Audit · Internal Structural Exam · Examination of Repairs · Administrative Inspection · COI Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6340426
5 July 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6199041
13 April 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6121689
13 January 2016 Administrative Inspection · Drydock Exam · DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5825900

Deficiency record · 79

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 October 2024 Resolved
Provision shall be made by means of plugs, covers, etc. to percent admission of air into the space. Ventilation louvers would not shut for both engine room spaces. 46 CFR 181.20-35 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2024
Resolution: Corrected. Louvers and assembly were rebuilt and added heavier material to close.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Port side mid-compartment and port side engine room bilge alarm is not operational. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2024
Resolution: Bilge alarm audible and visual are operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2024 No resolution recorded
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills. 46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2024 No resolution recorded
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Vessel's O/O is developing a chemical testing program to include random-testing by third party, but has not completed the program. Provide satisfactory evidence of a chemical testing program. 46 CFR 16.230(a)
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2024 Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers" and with the number contained therein, in at least 1-inch letters and figures. This legends shall indicate the separate stowage of children's life preservers. Missing port and starboard bench seating stowage markings for adult and child life preservers. 46 CFR 180.25-15(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: New signage was posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on vessels of not more than 65ft in length carrying not more than 49 passengers, provided that: The pump is permanently mounted. Bilge pumps and floats must be permanently mounted. 46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilge floats and pumps are mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room bilges were full of debris and rags. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilges in both engine rooms were clear of debris.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The bilge pipe on the port side mid-compartment was not properly secured. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Bilge pipe on the port side mid compartment was secured to a new 2 X 4 that was coated to protect from wood rot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Three holes were found in the port side engine compartment towards the stern. Replace with missing hardware. 46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: Holes were filled and made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The battery banks located in both engine compartments have overloaded terminals. Provide an additional terminal post so no more than four cables/wires are on each post, an ensure locking nut is fully threaded on. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2024
Resolution: A new battery terminal was installed for each battery bank and wires and were evenly distributated between batteries and new terminal with proper lugs and connectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 July 2024 Resolved
If your vessel is not operated on international voyages and does not meet the conditions in paragraph (d) of this section, it must undergo a drydock and internal structural examination as follows unless it has been approved to undergo an underwater survey (UWILD) per 176.615 of this part: (1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo drydock examination and an internal structural at least once every two years. Vessel's drydocking due date of June 29, 2024 has lapsed and vessel is overdue for credit drydocking. Vessel is not to operate with passengers onboard or conduct any dry docking repairs unless approved by the attending marine inspector. 46 CFR 176.600(c)(1)
Action required: 705 - Other - as specified
Resolved 20 December 2024
Resolution: Received credit drydock. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 1 Life jacket was ripped and unserviceable. 14 of required 140 life jackets onboard had wasted or missing retroreflective material. Replace 1 unserviceable life jacket. Install retroreflective material on 14 life jackets. Vessel passenger count reduced from 128 passengers to 113 passengers until deficiency is corrected. 46 CFR 180.71 46 CFR 185.604
Action required: 705 - Other - as specified
Resolved 4 December 2023
Resolution: Received photograph of new life jacket with appropriate markings. Additionally, received photograph of newly installed retroreflective material on 14 affected life jackets.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 November 2023 Resolved
Endorsements on Certificates of Documentation are valid for one year. Vessel's Certificate of Documentation expired on April 30, 2023. Provide proof that vessel owner has applied for renewal and received endorsement for a valid Certificate of Documentation. 46 CFR 67.163
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Received photograph of valid COD for the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 November 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years. Vessel's FCC Safety Radiotelephony certificate is expired. Provide proof of a valid FCC Safety Radiotelephony certificate to attending marine inspector. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Received photograph of valid FCC Safety Radiotelephony Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 November 2023 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material. Vessel's valid COI is not posted or kept onboard. Post vessel's valid COI in appropriate location. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 4 December 2023
Resolution: Recieved photograph of valid COI posted onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmemeber assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Community service hot-line number and employer's EAP policy are not posted or kept onboard. Display employer's EAP policy and hot-line number onboard to the satisfaction of the marine inspector. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2023
Resolved 8 December 2023
Resolution: Received photograph of employer's policy for drug/alcohol and hot-line number postage onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2022 Resolved
Vessels less than 65' carrying more than 49 passengers shall be outfitted with one fixed, power, bilge pump that is permanently connected to the bilge main. Both of the provided power bilge pumps were unable to dewater any of the compartments served by the bilge main. Vessel passenger count limited to 49 until the vessel is provided with a fixed, power, bilge pump capable of dewater all watertight compartments on the vessel. 46 CFR 185 2.25-10
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 September 2022
Resolution: Power bilge pumps were operational in all compartments.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2022 Resolved
An adult life jacket must be provided for each person on board a vessel. 12 Adult life jackets were either missing or un-serviceable. Vessel is restricted to 116 passengers until all life jackets required by the COI are provided. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 26 September 2022
Resolved 7 September 2022
Resolution: 12 new lifejackets were placed onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 August 2022 Resolved
Emergency exits used as a means of escape must be marked in legible letters "EMERGENCY EXIT, KEEP CLEAR". Markings provided were worn an illegible. Provide required markings. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2022
Resolved 7 September 2022
Resolution: Emergency exit was properly marked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 August 2022 Resolved
An audible and visual bilge high level alarm is required at the operating station for normally unmanned spaces with a non-watertight closure on the main deck. The audible and visual high water indicator for the port fuel tank space was inoperable. Provide the required alarm. 46 CFR 182.530
Action required: 10 - Deficiency Rectified
Resolved 25 August 2022
Resolution: Bilge alarm provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 August 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds. The starboard forward stanchion, second from outboard and the starboard, aft stanchion for the forward ladder railings were not secure to the deck. Repair and secure to the satisfaction of the attending marine inspector. 46 CFR 176.25-1 46 CFR 177.900
Action required: 10 - Deficiency Rectified
Resolved 25 August 2022
Resolution: Railings were repaired and secured to the deck.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 June 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The fiberglass in way of the strut mount for the port and stbd hulls were cracked and presented indications of water intrusion and delamination. Grind back for further inspection. Hull material found wasted, crop and renew per approved plans. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 29 June 2022
Resolution: Repairs completed IAW approved plans and industry accepted procedures.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020 Resolved
The owner or operator shall make a vessel available for drydock examinations. Vessels drydock was due 3/31/2020. Vessel must complete credit drydock with attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2022
Resolution: Vessel completed credit dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 June 2019 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss; vessels hatch covers does not have any device to prevent its loss. Attach hinges, captive chains or another device to prevent loss of hatch cover.-(OLD)46 CFR 171.124(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2019
Resolution: Received pictures hatch covers secured by stainless steel coated cable attached to wood frame by 1/4 inch eye
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel's starboard fuel tank void and port side forward void visual indicators are inoperable. Repair visual indicator for each void.-46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proving visual indicators have been repair and are operable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; Vessel's port midship void visual indicator indicates port midship void, port engine room, and port steering room is operating when only port midship void bilge pump is operating. Vessel must repair visual indicators to indicate when the correct bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proving each individual visual indicator is now operating for the correct bilge pump.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2019 Resolved
Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such a system. Cross space unites port and starboard engine rooms, thus creating one space. Secure cross space to separate engine rooms-46 CFR 181.420(c)
Action required: 705 - Other - as specified
Due 11 June 2019
Resolved 11 June 2019
Resolution: received photo. Cross spaces have been secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 June 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system; Closure devices for port and starboard engine room spaces does not properly close to secure ventilation. Repair closure devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video showing the operation of securing devices. Vessels closure devices properly secure each engine room
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice; Vessel's port side drip less shaft seal is constantly leaking into engine room. Repair shaft seal. -46 CFR 176.800(a)
Action required: 705 - Other - as specified
Due 11 June 2019
Resolved 11 June 2019
Resolution: Received video proving drip less shaft seal has been repaired and no longer leaking.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2019 Resolved
Repairs and alterations that affect the safety of the vessel must not be made without the approval of the cognizant OCMI; Vessel's swimming platform starboard support bracket is cracked at welding. Repair cracked welding on support bracket. Passengers are not allowed on swimming platform until repaired.-46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2019
Resolution: Received photos of weld repair. vessel rep tested secureness of swimming platform. Platform is secure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Submersible electric power pumps in port side steering void, starboard mid void, and piping for fixed power hand pumps are not secure. Secure submersible electric pumps and piping for fixed power pumps - 46 CFR 182.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received video proof submersible electric pump has been secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 6 June 2019 Resolved
Repairs and alterations that affect the safety of the vessel must not be made without the approval of the cognizant OCMI; Vessel's forward port cleat has loosened and cracked the surrounding deck. Make surrounding deck around the cleat watertight.-46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel has renewed surrounding deck around cleat. Deck is now watertight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 June 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 applied at any point in any direction. Forward deck rails are loose from deck. Tighten stanchions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received photos showing the securing of the stanchions in fordeck area.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 May 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct test and have vessel ready for inspection of the hull structure, electrical, and machinery. Vessel was not prepared for annual inspection. Vessel is restricted from operating with passengers for hire until a satisfactory annual inspection is completed as required by 46 CFR 176.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
Resolution: Inspection Completed
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 April 2017 Resolved
Port and Stbd ventilation shutdowns for engine room are inoperable. Renew ventilation shutdowns to create vapor tight seal in space for fire suppression system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2017
Resolved 18 April 2017
Resolution: Verified ventilation shutdowns properly function to create vapor tight seal in engine space for fire suppression system.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 13 April 2017 Resolved
Make entire engine room space vapor tight for fixed fire suppression system in port and stbd engine space. Multiple holes found in the overhead and forward bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2017
Resolved 18 April 2017
Resolution: Operator used fire retardant expansion foam to seal holes and create vapor tight barrier in engine space.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 April 2017 Resolved
Passengers are restricted from using aft swim step ladder until the proper repairs are made to the following: cracked fiberglass stairs on the stbd transom, cracked fiberglass transom where swim step support detached, disconnected railing on port side and under wooden swim step.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Proper repairs made to the aft swim step and transom.
Engineering › Steering Gear System › Linkage
Issued 13 April 2017 Resolved
Witnessed excessive movement at the tiller arm connection to the hydraulic arm on the port and starboard rudder. Operator will disconnect for further inspection of linkage.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator removed linkage pins and discovered severe wastage. Linkage pins replaced in kind and found satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 13 April 2017 Resolved
Repair seven inch long cracked and softened passenger deck located starboard side, five feet forward of the doorway leading to the forward passenger deck.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Passenger deck repaired with epoxy fiberglass and reinforced with marine grade plywood; all sat.
Engineering › Fuel Oil Service System › Piping
Issued 13 April 2017 Resolved
Replace or renew severed grounding wire on the port and starboard fill pipe for the fuel tank.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Grounding wire on the port and starboard fill pipe for the fuel tank attached and found in good order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 April 2017 Resolved
Replace cracked flexible hose connected to the thru hull valve in the starboard hull used to provide sea water to the MSD tank.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Flexible hose replaced.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 13 April 2017 Resolved
Provide written weather limitations and in-water briefing instructions for the crew to comply with reduced manning for snorkel operations IAW Sector Hono CID work instruction 31.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Company provided written weather limitations and in-water safety brief instructions for crew.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2017 Resolved
Replace ring life buoy and water light battery with USCG approved ring life buoy and battery for water light.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Ring buoy and battery replaced with USCG approved type.
Electrical › Electric Generation Source (service) › Conductor
Issued 13 April 2017 Resolved
A/C generator positive conductor ring terminal connection hole is larger than the nut used to fasten it. Replace the nut or ring terminal connection with appropriate size.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: A/C generator conductor connection and nut properly sized.
Electrical › Electric Generation Source (service) › Generator
Issued 13 April 2017 Resolved
Provide double hose clamps on generator exhaust discharge piping located in the port engine compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Double hose clamps found on generator exhaust discharge piping located in the port engine compartment.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 13 April 2017 Resolved
Provide over current protection IAW 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: AC circuit breaker replaced with QOU E84967 50 amp breaker, approved standards UL 489 and IEC-60947-2.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Replace all electrical terminal connections and provide covers for terminal connections in the port and starboard machinery space.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Electrical terminal strips and conductor connections were replaced in kind in the DC circuit, port and starboard side.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 13 April 2017 Resolved
Overcurrent protection fuse found severely corroded in the D/C circuit. Replace overcurrent protection IAW 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: DC circuit overcurrent protection, after the battery switch in port and starboard engine room, replaced with Ace Hardware 250 V a.c. Class RK5 cartridge fuse rated for 100 amps and an interupt rating of 200,000 amps.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2017 Resolved
Battery storage box located in the starboard machinery space found is constructed of wood. Wood rot found under the box and on both sides. Wood supports for the battery storage box found disconnected from the battery storage box due to wood rot.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fiberglass battery storage box contructed and found in sat condition.
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 April 2017 Resolved
Flexible hoses on raw water cooling system for port and starboard main engine found with soft spots, kinks, cracks, and holes. Hose clamps fell off of flexible hoses when touched by hand. Replace raw water cooling hoses in kind for port and starboard main engines.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Operator replaced in kind the main engine cooling water flexible hoses on the port and starboard main engine.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 April 2017 Resolved
Port main engine exhaust flexible piping is kinked at the thru hull penetration due to poor support for the entire exhaust piping. Starboard main engine exhaust is supported by nylon straps previously used on lifejackets. Provide adequate support for exhaust piping on the port and starboard main engines.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 12 May 2017
Resolution: Port and starboard main engine exhaust hose is adequately supported by metal supports.
Engineering › Fuel Oil Service System › Piping
Issued 13 April 2017 Resolved
Port main engine fuel delivery line found kinked just before the primary fuel filter in the port engine compartment. Replace fuel delivery line IAW 46 CFR 182.20-40.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fuel delivery line replaced with new piping. Replacement made in kind.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 April 2017 Resolved
Repair exhaust leak on the starboard main engine exhaust. Leak detected at the thru hull penetration.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Exhaust leak repaired. Double hose clamps were wasted and removed by operator. Operator replaced hose clamps in kind which stopped the leak of exhaust fumes in the engine room.
Construction/Loadline › Structures › Door
Issued 13 April 2017 Resolved
Repair door hinge to door providing access to port engine compartment found disconnected from the fiberglass it was bolted to.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator placed block of marine grade plywood under hinge to support bolts and fastened the hinge with new bolts; all sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 April 2017 Resolved
Remove oil and water in port and starboard machinery space bilge for inspection.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Bilge was found dry and inspected.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 13 April 2017 Resolved
All battery connections shall be made to the battery terminals with permanent connections.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: Permanent connections made at battery terminals.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Secure all dead end wires in the engine compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Dead end wires secured in engine room.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 April 2017 Resolved
95 adult and 03 child lifejackets found unfit for service. Passenger count reduced to 45 adult and 11 child unitl replaced IAW 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 17 April 2017
Resolution: 95 adult and 03 child new lifejackets purchased by operator and placed into service.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 April 2017 Resolved
Repair inoperable visual auto bilge indicator for starboard steering compartment and port forward void.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Visual auto bilge indicator for starboard steering compartment and port forward void found satisfactory.
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 April 2017 Resolved
Properly secure electrical conduit piping in port steering compartment.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Electrical conduit piping in port steering compartment found supported.
Fire Fighting › Fire Main › Condition
Issued 13 April 2017 Resolved
Fire pump piping located in the port hull found leaking at a pipe connection and at the manifold. Repair leaks to fire pump piping.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Operator repaired piping. Piping tested under pressure of the fire pump and found satisfactory.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2017 Resolved
Electrical junction box in the port fuel tank compartment found corroded. Replace junction box. 46 CFR 183.05-50(b)
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Electrical junction box in the port fuel tank compartment found replaced in kind.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 April 2017 Resolved
Secure fuel fill delivery flexible hose line on the port side fuel tank with double hose clamps.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Fuel fill delivery flexible hose line on the port side fuel tank found with double clamps.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 April 2017 Resolved
Lifejacket placard found onboard is in Japanese. Provide a lifejacket placard in languages for all passengers carried.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Lifejacket placard in Japanese and English found onboard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 13 April 2017 Resolved
Emergency instructions do not align with equipment carried onboard. Provide emergency instructions for equipment carried on the vessel.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: New emergency instructions found onboard and found satisfactory.
Navigation › Piloting/Steering › Marine Charts
Issued 13 April 2017 Resolved
Provide current marine charts and publications for operating area.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 8 May 2017
Resolution: Current marine charts found onboard.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2017 Resolved
Approved vessel plans indicate the vessel is outfitted with two generator and no battery chargers. Vessel currently has one generator and two battery chargers. Provide electrical drawings for A/C and D/C circuits onboard.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 July 2017
Resolution: Electrical drawing submitted with updated items included.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 March 2016 Resolved
Valid original not available. Provide prior to carrying passengers
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 March 2016 Resolved
9 child-sized life jackets unsat. Passenger count restricted to 5 persons under 90 pounds
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2016
Fire Fighting › Fire Hoses › Material
Issued 11 March 2016 Resolved
Provide appropriate hose and nozzle per regulations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 21 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 11 March 2016 Resolved
Provide a report from a third-party surveyor on condition of port hull prior to operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 13 January 2016 Resolved
Repair or replace electrical wires and cables damaged in engine room and void spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Construction/Loadline › Hull › Side Shell
Issued 13 January 2016 Resolved
Repair external hull structure areas in which delamination was found.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 January 2016 Resolved
Replace port side shaft and conduct proper alignment test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 January 2016 Resolved
Reomove and replace rotted transversal wood frames in stbd void #2 and port void #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 January 2016 Resolved
Remove and replace engine exhaust pipe insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 January 2016 Resolved
Remove oil soaked lagging and repair excessive oil leak from port side steering gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 January 2016 Resolved
Remove and replace insulation located in overhead engine room spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 January 2016 Resolved
Remove and replace engine exhaust pipe insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.