Records from 1981 to 2011. Most recent: inspection, 13 December 2011.
Inspection history · 59
13 December 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4207951
13 December 2011
Commercial Dive Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4212751
8 July 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4073885
14 February 2011
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3945323
27 October 2008
Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3352257
25 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3086678
27 July 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3008984
27 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3008997
22 May 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2650859
3 May 2006
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2858787
25 April 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2633282
29 July 2005
COI Inspection · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2444166
7 July 2004
Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2125371
12 September 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1903460
9 September 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1900534
29 July 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1860253
17 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1617841
4 April 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1787039
11 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 63823
4 May 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466770
25 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433700
24 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 17851
16 June 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469589
27 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126005
22 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 418593
1 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124145
26 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446589
21 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113827
25 March 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418149
26 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 515385
5 August 1996
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095516
27 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 99823
21 January 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455318
25 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190427
19 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414495
9 February 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 839046
10 August 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380059
21 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356357
6 October 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 77630
8 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248482
4 September 1992
Damage Survey · Permit to Proceed
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245875
3 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 138781
15 May 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357944
25 July 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250850
12 July 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920788
17 July 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888177
27 July 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341339
25 August 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338941
18 July 1987
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1024176
22 December 1986
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1028364
17 July 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985461
7 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305135
5 September 1985
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 991543
3 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291356
15 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286870
1 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282907
3 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278378
22 April 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971954
27 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963605
Electrical › Electric Generation Source (service) › Panelboard
Issued 8 July 2011
Resolved
Switchboard not equipped with interlock for power sources. Install interlock for switchboard
Action required: 705 - Other - as specified
Resolved 14 July 2011
Resolution: interlock installed
Engineering › Steering Gear System › Pump
Issued 27 October 2008
Resolved
Provide P.E. report indicating current steering gear system. Noted that orginal pump was disconnected and new pump installed. Steering pump can only achieve 25 degrees port and starboard.
Due 27 January 2009
Resolved 26 October 2009
Navigation › Piloting/Steering › Marine Charts
Issued 27 July 2007
Resolved
Failure to maintain up to date charts onboard
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2007
Resolved 25 October 2007
Pollution Prevention/Response
Issued 9 September 2003
Resolved
Provide annual hydrostatic test of fuel oil transfer hose prior to transfer of product.
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 15 September 2003
Resolution: Provided annual testing documentation.
Construction/Loadline › Structures › Superstructure
Issued 9 September 2003
Resolved
Repair port side bulkhead set in at aft cabin/bulwark connection at next credit drydock.
Action required: 705 - Other - as specified
Due 4 May 2004
Resolved 7 July 2004
Construction/Loadline › Structures › Superstructure
Issued 9 September 2003
Resolved
02 level at aft cabin door, deck wasted, bulkhead holed, crop and renew at next drydock.
Action required: 705 - Other - as specified
Due 4 May 2004
Resolved 7 July 2004
Navigation
Issued 9 September 2003
Resolved
Steering system idler chain at helm, remove excess slack, chain striking deck.
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 15 September 2003
Navigation
Issued 9 September 2003
Resolved
Provide steering pump run light per 46 CFR 58.25-25.
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 15 September 2003
Lifesaving
Issued 9 September 2003
Resolved
Provide boat hooks in lifefloats prior to carriage of offshore workers per 46 CFR 94.20-35 (old"I").
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 15 September 2003
Construction/Loadline
Issued 9 September 2003
Resolved
Demonstrate operation of forepeak bilge suction reach rod.
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 15 September 2003
Fire Fighting
Issued 9 September 2003
Resolved
Provide fire safety plan that reflects vessel's current equipment layout for approval.
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 18 September 2003
Engineering
Issued 29 July 2003
Resolved
Control air supply for MDE shutdowns improperly run (flex hose, clamps, etc), provide proper run per marine engineering sub "F".
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Engineering
Issued 29 July 2003
Resolved
Demonstrate bilge high level audible and visual alarms.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Pollution Prevention/Response
Issued 29 July 2003
Resolved
Provide annual hydro static test for F/O transfer hoses.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Construction/Loadline
Issued 29 July 2003
Resolved
Repair port side shell plate temporary repair (doubler) amidship approx. 4' above waterline, insert per NVIC 7-68.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Fire Fighting
Issued 29 July 2003
Resolved
Provide marine type fire extinguisher brackets.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Navigation
Issued 29 July 2003
Resolved
Provide rudder angle indicator per 46 CFR 113.40.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Navigation
Issued 29 July 2003
Resolved
Provide shaft tachs on pilot house control per 46 CFR 113.37.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 29 July 2003
Lifesaving
Issued 29 July 2003
Resolved
Provide emergency lights at embarkation area per 46 CFR 112.15-1.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Engineering
Issued 29 July 2003
Resolved
Fore peak bilge suction remote reach rod inop.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Lifesaving
Issued 29 July 2003
Resolved
Provide current (updated) fire safety plan for approval.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Engineering
Issued 29 July 2003
Resolved
Port generator F/O flex hose exceeds 30" max length.
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Engineering
Issued 29 July 2003
Resolved
Provide bilge pump suction mud basket strainer per 46 CFR 56.50-50(g).
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 9 September 2003
Navigation › Piloting/Steering
Issued 17 May 2002
Resolved
PROVIDE AND INSTALL A RUDDER ANGLE INDICATOR. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2002
Resolved 18 June 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 May 2002
Resolved
PROVIDE A VISUAL INDICATOR IN ENGINE ROOM FOR THE SOUND POWER PHONE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2002
Resolved 20 May 2002
Construction/Loadline
Issued 25 July 2000
Resolved
Install and demonstrate proper operation of visual bilge alarm indicator atoperating station to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 26 July 2000
Resolved 3 August 2000
Documentation
Issued 22 July 1998
Resolved
MASTER COULD NOT FIND GARBAGE LOG. WHEN FOUND IT WAS 03 MONTHS BEHIND.
Condition: Unknown
Due 23 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 22 July 1998
Resolved
VESSEL HAD LEAK IN RUDDER SHAFT PACKING. LEAK WAS CAUSING STEERING COMPARTMENT TO FLOOD. VESSEL MADE REPAIRS TO SATISFACTION OF INDEPENDENT SURVEYOR NEXT DAY IN CAMERON, LA.
Condition: Unknown
Due 23 July 1998
Resolved 27 July 1998
Engineering
Issued 22 July 1998
Resolved
EXHAUST LEAK IN ENGINE ROOM FORWARD MIDSHIPS ON UPRISER.
Condition: Unknown
Due 23 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 19 July 1995
Resolved
MAKE APPROPRIATE REPAIR TO CRACK AT PORT STERN CORNER AND TEST TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 27 July 1995
Resolved 17 August 1995
Unknown
Issued 7 April 1986
Resolved
SUBMIT TO [name withheld], TEXAS AN APPLICATION FOR REDUCED MANNING WHILETHE VESSEL IS SERVING AS A STAND-BY BOAT AND MOORED TO AN OFFSHORE BUOY.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986
Navigation
Issued 3 August 1985
Resolved
INSTALL ALL KNOBS ON THE SSB RADIO.
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Construction/Loadline
Issued 3 August 1985
Resolved
INSTALL A COUNTER BALANCE SPRING ON THE ENGINE ROOM ACCESS WATERTIGHT HATCH
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Electrical
Issued 3 August 1985
Resolved
INSTALL A GROUND AMMETER ON THE S/S SWITCHBOARD.
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Deck/Cargo
Issued 3 August 1985
Resolved
INSTALL FLAME SCREENS IN THE PORT AND STARBOARD F/O VENTS.
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Navigation
Issued 1 November 1984
Resolved
REPAIR OR REMOVE THE FATHOMETER.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIPS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984