This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
958 - Convention (Subpart B), Gross Ton
287 - Convention (Subpart B), Net Ton
Maury page id
psix-50240
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
In the 5th void port side, the 4th diagonal from fwd on the 1st and 2nd longitudinal the weld was detached and on the 4th longitudinal the weld was cracked.
Action required: 705 - Other - as specified
Resolved 18 August 2008
Resolution: Sent pictures verifying that the welds had been repaired.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 August 2008Resolved
In the 5th void port side, the 1st diagonal from fwd on the 3rd hopper longitudinal (aft side) there was a cracked weld.
Action required: 705 - Other - as specified
Resolved 18 August 2008
Resolution: Sent pictures verifying that the weld was repaired.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 August 2008Resolved
In the Aft rake stbd side, the 2nd support on the 1st longitudinal and 3rd longitudinal there were cracked welds.
Action required: 705 - Other - as specified
Resolved 18 August 2008
Resolution: Customer sent pictures verifying that the welds were repaired.
Documentation
Issued 17 November 1998Resolved
PROVIDE CURRENT VALIDATION FOR CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 30 November 1998
Resolved 29 November 1998
Documentation
Issued 17 November 1998Resolved
PROVIDE ON BOARD CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 30 November 1998
Resolved 29 November 1998
Navigation
Issued 21 November 1997Resolved
RE-MARK VESSEL WITH HAILING/HOMEPORT, LOADLINE, DRAFT MARKS, AND NAME.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 21 November 1997Resolved
PROVIDE AND INSTALL IN MACHINERY SPACE AN OIL POLUTION DISCHARGE PLACARD.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Engineering
Issued 21 November 1997Resolved
RE-MARK EMERGENCY FUEL SHUTOFF VALVE ON DIESEL FUEL OIL TANK.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Unknown
Issued 21 November 1997Resolved
PROPERLY INSTALL HYDRAULIC HOSE WITH PROPER TYPE STANDOFFS FROM DECKS.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Lifesaving
Issued 21 November 1997Resolved
CLEAN ALL FLAMABLE MATERIALS OUT OF MACHINERY SPACE, AND WIPE UP OIL ON DECK.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Navigation
Issued 21 November 1997Resolved
PROVIDE PROPERLY MOUNTED NAVIGATION LIGHTS OF AN APPROVED TYPE.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Electrical
Issued 21 November 1997Resolved
PROPERLY INSTALL ELECTRICAL WIRING WITH WATERTIGHT ENCLOSURES AND METAL STANDOFFS FROM DECKS AND BULKHEADS.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 4 December 1995Resolved
VESSEL IS RESTRICTED TO A ROUTE NO MORE THAN 3 MILES FROM THE COAST UNTIL VALID SOPEP IS REVIEWED AND APPROVED BY USCG.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Deck/Cargo
Issued 19 December 1989Resolved
SHOW PROPER OPERATION OF DIESEL OPERATED HYDRAULIC PUMP LOW LUBE OIL AND OVERSPEED TRIP.
Condition: Unknown
Due 19 December 1989
Resolved 19 December 1989
Deck/Cargo
Issued 1 November 1989Resolved
INSTALL ENVIRONMENTAL CONTAINMENT AROUND ON DECK DIESEL OIL TANK.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Deck/Cargo
Issued 1 November 1989Resolved
INSTALL FLAME SCREENS ON DIESEL OIL STORAGE TANK VENT.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Deck/Cargo
Issued 1 November 1989Resolved
INSTALL REMOTE F/O SHUT OFF VALVE ON DIESEL LINE.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989