Records from 2005 to 2025. Most recent: inspection, 18 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)72.1 ft × 24.0 ft × 9.5 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROTHERS BOAT · VANCOUVER WA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; 5 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
18 December 2025
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8283123
1 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8123380
5 March 2025
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8089015
6 March 2024
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7862051
28 December 2023
Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7841241
8 November 2022
SIP Inspection/Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7584379
14 December 2021
Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7363284
10 November 2021
SIP Inspection/Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7349839
29 January 2021
Annual Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7132924
11 December 2019
Drydock Exam · In-Service Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6871258
21 November 2019
SIP Inspection/Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6859980
19 December 2018
Administrative Inspection · SIP Inspection/Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600469
11 June 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441099
28 November 2017
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313952
14 November 2017
SIP Inspection/Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6306248
30 November 2016
SIP Inspection/Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6049097
20 April 2016
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5859189
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2025
Resolved
A power-driven fire pump shall be installed on each mechanically propelled “S” vessel which is a ferry vessel or which is permitted to carry more than 49 passengers, and on each mechanically propelled “L” vessel. During the annual inspection, MI observed the fire pump leaking. Repair to MI satisfaction prior to the carriage of passengers.
46 CFR 181.10-1(Old T)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: MI attended and observed SAT repairs and operational test of fire pump.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.. Crack was found below the waterline in the lazarette between rudder post and forward bulkhead that is actively seeping in water. Conduct temporary repair to the crack while vessel awaits to be hauled out for emergency dry dock. Once vessel is hauled out, provide repair proposal for permanent repairs to the satisfaction of the MI. Vessel is authorized a one time transit to BSY for the emergency haul out.
46 CFR 116.100(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2025
Resolution: Vessel made satisfactory repairs, MI witnessed satisfactory NDT to insert.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel was missing 07 life jackets on board. Reduce total persons allowed from
302 to 295 until life jackets are replaced.
1. Vessel self-reported 05 life jackets missing
2. Identified 02 life jackets not in serviceable
condition that were destroyed in the presence of the MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2024
Resolution: Vessel representative presented 10 new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2024
Resolved
Each life jacket must be marked with Type I retroreflective material. Multiple life jackets, including 03 child life jackets, needed the Type 1 retroreflective tape to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 14 March 2024
Resolution: Vessel replaced unsat life jackets and witnessed in person.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 March 2024
Resolved
A vessel must comply with the applicable requirements
for any radio and Electronic Position Indicating
Radiobeacon (EPIRB) installations, including the
requirements for a station license and installation
certificates to be issued by the FCC, as set forth in 47
CFR part 80. The vessel did not have its MMSI numbers
programmed into the VHF-DSC radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 11 April 2024
Resolution: Vessel rep sent satisfactory evidence to show MMSI programmed into the vessel radios.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
Except as provided otherwise in this subpart, all
electrical equipment including motors, generators, controllers, distribution panels, etc., shall be
drippoof protected. One of the lights on the main passenger deck was missing a guard.
46 CFR 183.10-10 (a)
"Old T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 14 March 2024
Resolution: Vessel representative put guard on light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 December 2023
Resolved
periodic examination made in accordance with the requirements of this subpart shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudders, through hull fittings, sea valves and strainers, and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended... Cutlass bearing on the port and starboard struts are wasted. Provide evidence of less than 50% waste or replace bearings.
46 CFR 176.15-5(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 January 2024
Resolution: Operator will replace at next credit dry dock
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 December 2023
Resolved
periodic examination made in accordance with the requirements of this subpart shall include the.. propellers, shafting, stern bearings..and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended...Operator plans to replace both port and starboard propellers.
46 CFR 176.15-5(a)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 February 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 December 2023
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel... Operator report two broken windows. Port forward and Starboard midship main deck. Replace windows to the satisfaction of the marine inspector.
46 CFR 116.1020
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 February 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 December 2023
Resolved
(a) The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection...Marine inspectors were unable to determine suitability of the interior hull due to excessive build up in the lazarette and water in the engine room bilge. Operator to conduct Ultrasonic thickness measurements of the entire lazarette void and the center line of the engine room.
46 CFR 177.01-5 “Old T”
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 February 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022
Resolved
A Coast Guard marine inspector will conduct required periodic and follow-on inspections necessary to ensure compliance with Coast Guard regulations. Certain components of company action plan lists inspection intervals at daily/monthly/quarterly (steering/lifesaving/firefighting) that are not being documented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 6 March 2024
Resolution: Vessel is no longer in SIP
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 November 2022
Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Both pilot house doors and engine room door had portions of gasket material missing.
46 CFR 116.1160
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 6 March 2024
Resolution: Verified weathertight condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 November 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Discovered 04 kapok PFD's that were were wasted and not serviceable. Replace PFD's accordingly.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2021
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
Electrical equipment exposed to the weather must be watertight. Discovered emergency batteries with slight water accumulation due to missing caps on covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2021
Resolved 21 January 2022
Resolution: Verified new caps on covers are installed to prevent future rain water from accumulating in battery box.
Construction/Loadline › Hull › Bottom Plating
Issued 14 November 2017
Resolved
Provide repair proposal for hole in the hull in engine room. 46 CFR 116.300
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2017
Resolved 28 November 2017