Records from 1998 to 2025. Most recent: inspection, 30 November 2025.
Documentation record
Registered dimensions (L × B × D)50.6 ft × 14.5 ft × 4.8 ft
Registered tonnagegross 30 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGUNDERSON BROS ENGINEER · PORTLAND, OR, UNITED STATES · built 1955
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNAKNEK, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Net Ton
30 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
30 November 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8278465
16 April 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8112969
16 April 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8113033
3 September 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7995404
6 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7907674
17 April 2024
Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7896769
28 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7658742
31 January 2022
COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7377745
28 May 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5139101
26 January 2015
Deficiency Check · Administration · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5059198
3 May 2013
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586270
30 November 2011
MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4197544
21 March 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976126
23 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701475
14 March 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2602620
28 April 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2348721
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978364
5 March 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1754801
30 December 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 126097
4 August 1998
Uninspected Towing Vessel
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 795955
21 July 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 38162
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2024
Resolved
Emergency lighting in the engine room was wired incorrectly. Install emergency lighting in accordance with current regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2024
Resolved 9 May 2024
Resolution: Received photos of e-lighting wiring do correctly and light working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2023
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Vessel requires a check valve on all bilge suction. Engine room bilge suction failed to remove water from the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2023
Resolution: Tested bilge pumping arrangements. Satisfactorily dewatered compartment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 March 2023
Resolved
Fire-detection systems. Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29 CFR 1910.7; and the system is installed, tested, and maintained in accordance with the manufacturer's design manual. The vessel's fire control panel is overdue on inspection from an approved authority.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2023
Resolution: Received copy of fire detection servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Bus bar on forward most bulkhead of engine room requires an enclosure to limit hazards.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 27 April 2023
Resolution: Bus bar enclosed and protected from hazards
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2023
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessels sound signal (horn) failed to actuate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 27 April 2023
Resolution: Successfully tested horn.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 March 2023
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass. The compass must be readable from each operating station. The vessel's magnetic compass failed to illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 27 April 2023
Resolution: Magnetic compass light fixed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 28 March 2023
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. Master in attendance could not adequately describe required details needed in a navigational assessment. The company operations procedures fail to provide details on these requirements listed in 46 CFR 140.635(a)(1-13).
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2023
Resolution: The Navigation assessment has been added to their required pre-departure checks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 January 2022
Resolved
There must be an installed or portable bilge pump for emergency dewatering. All installed bilge piping must have check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. The vessel had two installed pumps, however they did not work when inspected by MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2022
Resolved 2 February 2022
Resolution: Witnessed satisfactory operation of bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 January 2022
Resolved
Vessel shall have means provided for stopping each ventilation system serving machinery spaces and for closing in case of fire. MI observed no vent covering below the ladder that has access to the engine room.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 2 February 2022
Resolution: Witnessed installation of vent cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 January 2022
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 1 inch high "WATERTIGHT DOOR-KEEP CLOSED". MI observed 2 watertight doors that were not marked, 1 for the estate room and 1 forward space for head/ gear room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: Put correct labels on doors satisfaction of MI
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 January 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas for sufficient illumination under emergency egress from each space. Crew estate room emergency lighting was inoperable.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: Corrected on the spot.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010