Records from 1981 to 2026. Most recent: inspection, 27 May 2026.
Inspection history · 62
27 May 2026
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8381935
27 October 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8260521
29 October 2024
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026490
24 October 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8027041
9 September 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7999063
26 June 2024
COI Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7942994
20 April 2023
COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7670237
4 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7409345
13 January 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7390363
25 October 2021
Administrative Inspection · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7337896
20 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7337599
23 September 2021
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7319046
23 July 2020
Deficiency Check · In-Service Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7019483
26 June 2020
Deficiency Check · Initial Certification · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6987721
17 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514868
27 October 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5012795
10 September 2014
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4990870
26 June 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4906409
9 January 2013
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4513274
14 September 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4440615
13 September 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4444136
16 August 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4412510
6 July 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4369880
27 June 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4359382
10 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4244123
1 March 2011
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3956363
28 February 2011
Spot Check (Safety) · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3954812
29 November 2010
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3900560
17 November 2010
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3893006
27 July 2010
Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3808179
24 July 2010
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3828418
15 March 2010
Hawser Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3702436
25 January 2010
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3669571
19 October 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3620688
19 October 2009
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3623404
19 August 2009
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3571344
5 February 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3146164
31 October 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3091259
13 December 2006
MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2839620
21 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2826308
18 October 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2803927
21 February 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 693637
23 November 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 213117
18 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244412
19 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185284
12 June 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357196
5 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693638
14 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 65482
17 November 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175994
1 September 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860896
26 July 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438207
16 July 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 501187
1 June 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448436
17 May 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341661
9 September 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350335
2 July 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334903
12 August 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014321
1 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296765
22 May 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281796
29 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272382
5 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276378
16 July 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273536
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 November 2025
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck. Semi-portable not properly secured or in a location where hose would reach E/R.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Resolved.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 10 November 2025
Resolved
The following alarms must be provided: (6) Low hydraulic steering fluid level. Alarm must be visible and audible at operating station. No alarm for steering fluid fitted on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Installed and tested. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 November 2025
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Marked.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 10 November 2025
Resolved
The line throwing appliance must have: An auxiliary line that is at least 1,500 feet long. Line is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Multiple exposed wires found in E/R. One emergency light in E/R works intermittently. Several junction boxes in E/R are not properly mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 November 2025
Resolution: Repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 October 2025
Resolved
The owner and managing operator must ensire that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. The vessel's pilot house alerter system has not been functioning for an extended period of time and personell claimed they did not even have the key to activate it. Ship's horn was also inoperable and has been for some time.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2025
Resolution: Tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel informed that the starboard
M/E turbocharger failed.
46 CFR 143.205(a)
17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2024
Resolution: Vessel installed new turbo.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 3 September 2024
Resolved
A towing vessel with overnight accommodations and alternating watches must have a system to detect when the master or mate become incapacitated. The system must have an alarm in the pilot house distinct from any other alarm, require action from officer in charge not exceeding 10 min. and notify crew with in 30 sec. if not acknowledged. Vessel must be manned with two persons on bridge until installed.
46 CFR 143.450
Code 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2024
Resolved 9 September 2024
Resolution: Installed night watchman II.
01 - Certificates & Documentation › 011 - Ships Certificates › Special Purpose Ship Safety
Issued 26 August 2024
Resolved
The results of the inspections required by 33 CFR 164.76 must be documented in the TVR, official logbook or IAW the TSMS if applicable. Record of type, size and service of each towline, face wire and spring line used to make the towing vessel fast to her tow to include dates when examinations were performed, the identification of each tow gear examined and name of person conducting the exam. Vessel is required to start a new Towing Vessel Record or log these in the official log book.
46 CFR 140.805
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: New log started with all new towing cable installed on the vessel.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 August 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The STBD MDE J/W temp gauge is not working on the bridge. Replace to the satisfaction of the attending MI.
46 CFR 143.230
Code 50c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 9 September 2024
Resolution: New gauge installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 August 2024
Resolved
Illuminated magnetic compass. The compass must be readable at each operating station. Vessels compass light appears to have been disconnected when other repairs were made to the electrical system. Correct to the satisfaction of the attending MI.
46 CFR 140.725 (d)
Code 50c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Wiring hooked back up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 August 2024
Resolved
A 40B portable fire extinguisher must be located near the storage cabinet (flame stores). Vessel installed a new flame stores cabinet and is required to move the 40B extinguisher to the new location.
46 CFR 142.225 (d)
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 August 2024
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI. Vessel has a wasted stair structure on the port side of the 01 deck at the bridge entrance. Crop and renew the deck plating and wasted flat stock forming the structure of the stairs to the satisfaction of the attending MI.
46 CFR 144.200 (b)
Code 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Renewed with new metal.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 August 2024
Resolved
Alarms and monitoring: Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm. The alarm beacon located at the aft operation station is not working. It must alarm for high j/w, low l/o pressure of each engine. Aft operating station can only be used if a manned watch is located on the main bridge or in the engine room until corrected.
46 CFR 143.230
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Audible and visual alarm installed and tested satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2024
Resolved
A vessel must be operated IAW applicable laws and regulations in such a manner to afford protection against hazards to life, property, and the environment. Vessel does not have a lock out tag out procedure. A proper lock out tag out log must be maintained to prevent shock from energized equipment.
46 CFR 140.205 (a)
Code 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 August 2024
Resolved
General Alarm: has installed in the engine room a supplemental flashing red light with a sign that reads, "Attention General Alarm-When alarm sounds or flashes go to your station". Vessel must place signage by the general alarm in the engineering space.
46 CFR 143.235 (b)(3)
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Posted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2024
Resolved
Electrical conductors passing through water tight bulkheads must be installed so that the bulkhead remains water tight. Cable penetration running through the engine room forward to the tunnel is open with no water tight preventative filling. Replace to the satisfaction of the attending MI.
46 CFR 143.400 (h)
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Firestop intalled.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 August 2024
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. Bench grinder in the engine room has both guards removed. Replace to the satisfaction of the attending MI.
46 CFR 144.820
Code 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2024
Resolved
Electrical systems must be designed and maintained to provide for safe operation. Hydraulic pump fwd engine room had tape over breaker. Tag out IAW proper lock out tag out procedures.
46 CFR 143.205 (a)
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Properly tagged out.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 August 2024
Resolved
Safety Orientation: Awareness of and expected response to any other hazards inherent to the operation of the towing vessel which may pose a threat to life, property or the environment. Crew unfamiliar with proper aligning of the fire main. Post diagram for proper alignment and have valves labeled so all members of the crew can properly activated the system.
46 CFR 140.410
Code 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Completed
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 26 August 2024
Resolved
Safety Orientation: Awareness of and expected response to any other hazards inherent to the operation of the towing vessel which may pose a threat to life, property or the environment. Crew unfamiliar with proper aligning of the bilge system. Post diagram for proper alignment and have valves labeled so all members of the crew can properly activate the system.
46 CFR 140.410
Code 50c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: Completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 August 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Switchboard amp meters not working. Replace to the satisfaction of the attending MI.
46 CFR 143.400 (a)
Code 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2024
Resolved 3 September 2024
Resolution: New gauges installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 August 2024
Resolved
Each towing vessel must be equipped with navigation lights. Vessel stern light was out, it was corrected on the spot.
46 CFR 140.720
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 August 2024
Resolved 26 August 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 August 2024
Resolved
Smoke detection in berthing space. Each towing vessel must be equipped with a means to detect smoke in berthing spaces. This may be accomplished by an installed detection system or UL 217 smoke detectors. New detectors were taken from company office to install in berthing areas.
46 CFR 142.330 (b)
Code 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 August 2024
Resolved 26 August 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 August 2024
Resolved
An approved 160 B:C semi-portable extinguisher must be provided to protect the engine room. The 160 B:C was in the engine room and was required to be moved to the next space over so it could be used in the event of an engine room fire. Corrected.
46 CFR 142.315 (a)(3)(i)
Code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 August 2024
Resolved 26 August 2024
Resolution: Corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2021
Resolved
Vessel has multiple unresolved defs from its last annual inspection on 25 Oct 2021. Vessel is restricted from operating until all outstanding defs have been completed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 December 2021
Resolution: All deficiencies have been cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 October 2021
Resolved
The vessel is an inspected towing vessel under sub-chapter M. This vessel is required to conduct an Annual Inspection within three months after or prior to the Anniversary Date. The inspected vessel's deadline lapsed, having an Annual Inspection conducted (05) days after the alloted window in their Anniversary Date
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 October 2021
Resolved 25 October 2021
Resolution: Vessel inspection conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2021
Resolved
Each towing vessel is required to have a sufficient amount of alcohol testing devices ready accessible on board. This vessel contains expired alcohol testing kits. Provide approved equipment able to sufficiently conduct alcohol testing for the crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Alcohol testing strips provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021
Resolved
Towing vessels inspected under sub-chapter M are not permitted to utilize extension cords as a permanent connection to a source of electrical power. This vessel contains multiple sets of extension cords throughout.
Remove all extension cords and multi-outlet adapters.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Improper cabling removed and proper cabling installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 October 2021
Resolved
Towing vessels inspected under sub-chapter M are not permitted to utilize extension cords as permanent
connections. Remove the extension cord for the overhead
deck light and install a permanent connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Extension cords cabling on pilothouse removed and permanent cabling installed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 October 2021
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent injury or risk of fire. Both engine exhausts lack the proper installation of lagging or guarded material to prevent injury and/or to prevent a potential fire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Missing exhaust lagging installed.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 25 October 2021
Resolved
Towing vessels inspected under sub-chapter M are required to have an installed fire detection control panel. The inspected vessel's fire detection control panel has a light identifying a fault in the system and tech report explaining system capability. Replace fire control panel with a proper installed system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2021
Resolved 1 December 2021
Resolution: Fire detection systems faulty card was replaced and tech report provided.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 25 October 2021
Resolved
The inspected vessel contains (01) rusted ladder rung on the starboard side of the maindeck, leading up toward the 0-1
deck. The ladder rung is wasted beyond repair, renew as original.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Wasted steps replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021
Resolved
All fire stations are missing spanner wrenches. Provide spanner wrenches for fire stations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Spanner wrenches installed at all fire stations.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 October 2021
Resolved
The Bridge aft escape route is obstructed by a Spill Kit. Escape routes shall be unobstructed and able for safe and effective access; make escape route free from obstruction.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Obstructions removed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 25 October 2021
Resolved
Towing vessels inspected under sub-chapter M are required to have individual circuit breakers on switchboards labeled with a description of the loads they serve. The switchboard located in the Engine Room is missing proper labeling to identify each individual component.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: All breakers properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021
Resolved
Inspected towing vessels must maintain machinery and electrical systems to provide for the safe operation of the vessel and persons onboard during normal/emergency conditions. The interlock system provided on the switchboard is inoperable and provides an unsafe condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Switchboard mechanical interlock properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 25 October 2021
Resolved
Towing vessels inspected under sub-chapter M are
required to have proper retrieval equipment to
adequately respond to a Man overboard situation. This
vessel does not contain a rescue ladder, thus
eliminating the potential to retrieve an injured or
incapacitated crewmember.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Visually inspected new rescue ladder. Satisfactory condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021
Resolved
Emergency lighting must be provided in all working areas throughout the vessel. Repair or replace all inoperable emergency lighting devices in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: White strobe light repaired and in satisfactory condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021
Resolved
The batteries for the starboard engine ECU are inproperly installed. Properly wire batteries.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 17 November 2021
Resolution: Starboard engine ECU batteries properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2021
Resolved
The shaft packing gland backing plates for both shafts are wasted and warped beyond repair. Repack glands and replace or renew backing plates.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Both port and starboard shaft packing have been replaced and are in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021
Resolved
Inspected towing vessels are required to store paints, coatings, and other flammable or combustible products in an approved flam locker when not in use. Remove or properly stow 5 gallon buckets of hydraulic fluid stored in Engine room vestibule.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 1 December 2021
Resolution: Vessel has ensured that all flammable and combustible products have been placed in a designated storage space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 October 2021
Resolved
Inspected towing vessels that have watertight doors must ensure their watertight integrity and functionality. The watertight door leading to the engine room is placed in improper service held on by damaged hinges. Additionally, the watertight door is being supported by rope, and inoperative. Marine Inspectors put into question the installation of the watertight door and its current placement. Provide scantlings to verify if the validity of the watertight door's placement.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2021
Resolved 1 December 2021
Resolution: Watertight door is satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2020
Resolved
Marine Employer placed Master into safety sensative position prior to obtaining a negative pre-employment test
Action required: 10 - Deficiency Rectified
Due 7 August 2020
Resolved 7 August 2020
Resolution: Negative test received 3 days after master was placed into position
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2020
Resolved
Marine Employer failed to submit MIS reports as per regulations
Action required: 10 - Deficiency Rectified
Due 7 August 2020
Resolved 7 August 2020
Resolution: MIS Reports submitted retroactively following discovery by CG
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 20 July 2020
Resolved
Each towing vessel 79 feet or more in length operating on oceans and coastwise routes that does not have an installed fixed fire-extinguishing system must have at least two firefighter's outfits and two SCBA with minimum 30-minute air supply. Vessel does not have a fixed fire-fighting system and does not have any firefighters outfit or SCBA’s.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 July 2020
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires that is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a NICET level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience. Detection system was not certified
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 10 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020
Resolved
The marine employer must ensure that their crew members meet the requirements for drug and alcohol testing. The master was unable to provide any drug testing records. The master was unaware of the DER or SAP. The person listed as the Company POC for drug testing does not work for Beyel. Marine employer must successfully pass a DAPI Audit.
Action required: 705 - Other - as specified
Due 20 July 2020
Resolved 10 August 2020
Resolution: DAPI Audit Complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The port and starboard main engine exhausts were missing the first section of lagging after the turbochargers.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 July 2020
Resolved
A towing vessel record is required for vessels not operating in a limited geographical area or required to maintain an official logbook. The master could not provide a towing vessel record of the items required to be recorded in 46CFR140.915.
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020
Resolved
The master of a towing vessel must keep an accurate list of crew members and their assigned positions and responsibilities. Crew members with emergency duties and duty stations on towing vessels equipped with overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. Vessel master could not provide crew member duties regarding fire, flooding, launching survival craft, or man overboard procedures.
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 July 2020
Resolved
The owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include record-keeping procedures. The owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan. Master unable to provide a Health and Safety Plan.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 10 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 July 2020
Resolved
Each towing vessel operating on oceans, coastwise, limited coastwise, or beyond 3 nautical miles from shore upon the Great Lakes must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon (EPIRB) that meets the requirements of 47 CFR part 80. The EPIRB battery expired in January 2020.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
All pressure vessels must have the MAWP indicated by a stamp or nameplate, be externally examined annually, and the relief valves must be tested IAW§ 143.245. Paint covered the name plate MAWP making it ineligible and the crew could not provide evidence the relief valves were examined or tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Gasoline for emergency fire pump was stowed on deck not within a dedicated stowage room or cabinet.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Neither ammeter for starboard or port diesel generator were functioning nor was the ground detection.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 20 July 2020
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance under approval series 160.040. No line throwing appliance is onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 10 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 July 2020
Resolved
Each towing vessel must maintain required navigation equipment in fully-functioning condition. The compass has 10 degrees of deviation with an undated deviation card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2020
Resolved 21 February 2024
Resolution: Def cleared by follow-on annual activity but not cleared in MISLE.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 July 2020
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil…shall provide transfer procedures that meet the requirements of this part and part 156. The vessel has a fuel oil capacity of over 250 barrels and does not have transfer procedures.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2020
Resolved
The fire hose must be fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. The fire hose attached to the engine room hydrant was not capable of producing a solid stream, only a spray pattern.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting at the forward entrance to the engine room was not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Access cover to reach-rod t-handle controlling bilge piping valve in forepeak could not be removed and valve operation could not be verified.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 July 2020
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Several windows throughout the vessel were leaking and one window in the aft steering station was broken/missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 7 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 July 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Noted multiple electrical hazards including, but not limited to; open junction boxes (missing covers), improperly wired air conditioning compressor, missing blanks in breaker panels, several connections made with wing-nut type connectors, not within an enclosure, breaker panels not labeled index, generator starter battery not covered, melted split wire loom lying on top of starboard generator, and multiple outlets with removed/broken opening covers.
Action required: 30 - Ship detained
Due 20 July 2020
Resolved 7 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2019
Resolution: Completed
Documentation
Issued 26 July 1994
Resolved
FCC STATION LICENSE NOT ON BOARD. HAS BEEN APPLIED FOR
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994