MAURY USCG vessel records Sign in
← All vessels

CYRUS ANTHONY

CYRUS ANTHONY is a 1979 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1981, most recently in May 2014, along with 58 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2004.

Records from 1981 to 2014. Most recent: inspection, 20 May 2014.

Built
1979
Last inspected
20 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7732
Flag
UNITED STATES
367105580, 367106040 (licence lapsed)
Maury page id
psix-50424

Inspections, by type

…with no type recorded25
Years with a record 23 calendar years (1981–2014)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC9732MMSI 367106040 · expired · compulsorily equipped · granted 12 April 2006, cancelled 18 June 2016
WDC9698MMSI 367105580 · cancelled · voluntarily equipped · granted 7 April 2006, cancelled 11 April 2006
WCW2283MMSI not assigned · expired · compulsorily equipped · granted 28 February 1996, cancelled 6 May 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SARGASSO Tank Ship · MISLE 54693 · 28 July 1998 · activity 25350

Inspection history · 57

20 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4862311
13 May 2014 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4857825
8 May 2014 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4852817
1 May 2014 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4847621
6 May 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4303186
26 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4232102
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200097
26 March 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438416
9 April 2008 Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3176098
15 January 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3175454
31 May 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2948132
30 May 2007 Damage Survey · In-Service Inspection · Re-Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2946552
26 April 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2916057
26 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2916217
4 May 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2640161
3 April 2006 Deficiency Check · Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2615192
2 November 2005 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2526939
27 April 2005 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2343964
14 December 2004 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2258957
14 May 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2070594
12 May 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2078874
22 March 2004 Hull Examination · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2029369
8 May 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1786738
2 April 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1599806
29 June 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472281
2 May 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399356
7 April 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361406
19 July 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450322
20 October 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801523
28 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25350
28 July 1998 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130804
11 June 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791639
20 May 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454551
26 March 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788178
1 January 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 23885
22 May 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411480
15 April 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 711720
18 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1106778
14 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 711721
13 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 768621
12 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 63816
12 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 199608
12 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 711719
11 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 95571
9 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 149450
23 May 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385727
5 September 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005885
5 September 1985 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1297391
29 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283702
24 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982645
6 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282728
4 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280488
25 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965718
30 September 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965690
2 November 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271156
7 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964030
5 October 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969020

Deficiency record · 58

Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 20 May 2014 No resolution recorded
Vessel is not conducting routine visual inspections IAW with EPA VGP.
Action required: 705 - Other - as specified
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 May 2014 Resolved
Vessel needs to post Emergency Instructions for fire, heavy weather, and MOB IAW 46 CFR 185.510.
Action required: 705 - Other - as specified
Resolved 20 May 2014
Resolution: Vessel posted Emergency Instructions.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 20 May 2014 No resolution recorded
Vessel is not updating charts IAW local notice to mariners corrections.
Action required: 705 - Other - as specified
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 13 May 2014 Resolved
Properly rig life floats for float free arrangment, under 400 lbs, labeled, and correct lines installed.
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 20 May 2014
Resolution: Deficiency cleared by attending marine inspector during course of annual inspection on 20May2014.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve, Check (air start)
Issued 13 May 2014 Resolved
Properly secure air starters. Stbd inboard main air starter has one of three bolts holding it in place, loosely.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 20 May 2014
Resolution: Deficiency cleared by attending marine inspector during course of annual inspection on 20May2014.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 May 2014 Resolved
Tighten sea chest so no obesrved leakage comes into hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 20 May 2014
Resolution: Deficiency cleared by attending marine inspector during course of annual inspection on 20May2014.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 6 May 2012 Resolved
Temperature guages for the #3 and #4 engines on the bridge inoperative. Vessel shall repair to original condition.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 8 May 2012
Resolution: Visually inspected new temperature guages for the #3 and #4 engines while both engines were operating.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 May 2012 Resolved
#4 engine E-Stop not working correctly on the bridge. Vessel shall repair to original condition.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 8 May 2012
Resolution: Visually verified #4 engine E-Stop correctly stop the engine upon operation.
Fire Fighting › Fire Hoses › Condition
Issued 26 March 2009 Resolved
STBD side fire hose burst during operation/ was destroyed. Provide with new hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Engineering › Fuel Oil Service System › Pump
Issued 26 March 2009 Resolved
Lable fuel pump in engine room
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 26 March 2009
Communications › Radio Communications › EPIRB
Issued 26 March 2009 Resolved
EPIRB was not easily released from holder. Must be able to demonstrate proper release.
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 26 March 2009
Lifesaving › Lifefloat › Paddle
Issued 26 March 2009 Resolved
Paddles of lifefloat were loose. Tie down paddles to lifefloat.
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 26 March 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 March 2009 Resolved
Plate that stern light is fixed on has been bent upward. Demonstrate proper arc of visibility of stern light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2007 Resolved
Not all bilge alarms were operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 June 2007 Resolved
Two unused overboard discharge locations were found in the engine room that needed to be capped off.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2007
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 30 May 2007 Resolved
The engine room blowers were excessively oiled and missing the rotating machinery guards.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 30 May 2007 Resolved
Cracks were noted in one fuel tank and ballast water tank.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Construction/Loadline › Hull › Side Shell
Issued 30 May 2007 Resolved
An insert was required in the port side shell above the overboard exahust approximately 18" x18" due to deep gouges.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Stability › Weathertight Integrity › General
Issued 30 May 2007 Resolved
The entire engine room was covered in rain water due to missing bolts for the engine access covers.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2007 Resolved
The marine charts onboard were not current and no longer legible due to tears/stains.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 May 2007 Resolved
The overboard discharge for the starboard diesel engine was wasted below the water injection area and covered with silicone to plug severe leaks.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 30 May 2007 Resolved
Exposed wiring was discovered in the rudder compartment (bilge alarm wiring).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2007
Construction/Loadline › Hull › Weld
Issued 30 May 2007 Resolved
Several broken welds were found throughout the engine room and forward machinery space.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Stability › Unintentional Flooding › General
Issued 30 May 2007 Resolved
Piping from the forward head area behind the false bulkhead was left open and covered with tape.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Construction/Loadline › Penetrations › Flange Pad
Issued 30 May 2007 Resolved
The rudder post assembly was not properly secured with bolts/double nuts.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 30 May 2007 Resolved
A CG-2692 was not submitted within the 5 day reporting time frame following a casualty that occurred on 17APR2007.
Action required: 705 - Other - as specified
Resolved 6 May 2010
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 30 May 2007 Resolved
Immediate notice was not made to the CG follwing a marine casualty.
Action required: 705 - Other - as specified
Resolved 6 May 2010
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 May 2007 Resolved
Upon conducting a general walk through of the vessel following a damage survey, the operating condition of the vessel was deplorable. *See MISLE activity #2946552.
Action required: 705 - Other - as specified
Resolved 26 March 2009
Electrical › Electric Generation Source (service) › Generator
Issued 30 May 2007 Resolved
The port and starboard generator's had excessively oily armatures.
Due 30 June 2007
Resolved 13 June 2007
Operations/Management › Ballast Water Managment › Training
Issued 3 April 2006 Resolved
The vessel had a very generic BWMP. Must provide vessel specifics.
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 6 May 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 April 2006 Resolved
Vessel had a mix up with the application for the COD due to vessel name change. Vessel has expired COD onboard and application for a new COD.
Action required: 705 - Other - as specified
Due 13 May 2006
Resolved 4 May 2006
Resolution: COD receieved, with new vessel name.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Grid and reweld broken weld on first frame, port side in lazarette.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Grid and reweld broken weld for support to port steering gear ram.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Construction/Loadline › Hull
Issued 23 March 2004 Resolved
Grid and reweld cracked welds on rear planning wedges in way of rudders.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Construction/Loadline › Penetrations
Issued 23 March 2004 Resolved
Clean hull penetration valve seats from marine growth.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004 Resolved
Provide CPR/First Aid training and documentation for 50% of the crew.
Action required: 705 - Other - as specified
Due 25 April 2004
Resolved 14 April 2004
Communications › Radio Communications › EPIRB
Issued 23 March 2004 Resolved
Ensure EPIRB registration is renewed prior to 30 Sep 04.
Due 30 September 2004
Resolved 14 December 2004
Resolution: Received faxed confirmation of EPIRB registration. New registration expires 03AUG2006.
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004 Resolved
Renew expired medication in both first aid kits.
Action required: 705 - Other - as specified
Due 25 April 2004
Resolved 14 April 2004
Electrical › Lighting (service)
Issued 23 March 2004 Resolved
Replace broken light covers in master and engineers staterooms.
Action required: 705 - Other - as specified
Due 25 April 2004
Resolved 14 April 2004
Fire Fighting › Means of Escape › Escape Route Signs
Issued 23 March 2004 Resolved
Stencil emergency exits on both sides of exit in upper passenger area and aft bridge.
Action required: 705 - Other - as specified
Due 25 April 2004
Resolved 25 April 2004
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 8 May 2003 Resolved
Provide third party gauging report and U-!As for both air receivers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 28 April 2005
Resolution: Conducted sat hydrostatic testing of both air receivers.
Construction/Loadline
Issued 28 July 1998 Resolved
REPAIR DAMAGE SUSTAINED IN COLLISION TO THE FORWARD STBD BULWARK AND FOREPEAK. ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMIPRIOR TO GETTING UNDERWAY, BUT NOT LATER THAN 13AUG98.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 28 July 1998 Resolved
REPAIR/REPLACE WATERTIGHT DOOR INDICATOR POSITION INDICATING PANEL IN WHEELHOUSE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Unknown
Issued 28 July 1998 Resolved
THE FOLLOWING IS A RECOMMENDATION MADE IN KEEPING WITH STANDARDS OF GOOD MARINE PRACTICE. IT IS STRONGLY RECOMMENDED THAT YOU PROVIDE TRAINING FOR THE CREW ON THE IMPORTANCE OF MAINTAINING WATERTIGHT DOORS CLOSED AT ALL TIMES WHILE UNDERAY.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 28 July 1998 Resolved
REPAIR/REPLACE VHF RADIO HANDSET ADJACENT TO AFT STEERING CONSOLE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 28 July 1998 Resolved
THE FOLLOWING RECOMMENDATION IS MADE IN KEEPING WITH GOOD MARINE PRACTICE. IT IS RECOMMENDED THAT THE COMPANY MOVE THE VHF RADIO OVER THE CHART TABLE TO THE FORWARD STEERING CONSOLE IN THE WHEELHOUSE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Construction/Loadline
Issued 28 July 1998 Resolved
LABEL ALL WATERTIGHT DOORS ON BOTH SIDES TO INDICATE THAT THEY SHALL REMAINCLOSED AT ALL TIMES WHILE UNDERWAY.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Engineering
Issued 28 July 1998 Resolved
REPAIR FUEL LEAK TO ENGINE # 3 (STBD INBOARD) AND CLEAN TURBO.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
REPAIR/REPLACE DOGGING MECHANISM FOR THE AFT PORT SIDE ENGINE ROOM ESCAPE HATCH.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 28 July 1998 Resolved
REPLACE ALL BLOWN BULBS FOR LIGHTING, AND REPAIR/REPLACE LIGHT FIXTURE IN ENGINE ROOM.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
REPAIR/REPLACE CRACKED WINDOW IN WHEELHOUSE FORWARD STBD SIDE.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 20 May 1998 Resolved
FIX AND PROVE PROPER OPERATION OF ENGINE RPM GAUGES ON BRIDGE.
Condition: Unknown
Due 20 June 1998
Resolved 23 June 1998
Engineering
Issued 22 May 1997 Resolved
REPAIR FUEL OIL LEAK ON #1 MAIN DIESEL ENGINE LOCATED ON INBOARD HEAD ASSEMBLY.
Condition: Unknown
Due 5 June 1997
Resolved 29 May 1997
Fire Fighting
Issued 18 March 1997 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Documentation
Issued 23 May 1996 Resolved
Obtain current radio safety equipment certificate to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 23 June 1996
Resolved 4 June 1996
Accommodation/Occupational Safety
Issued 23 May 1996 Resolved
Repair passenger toilet facilities to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 30 May 1996
Resolved 4 June 1996
Unknown
Issued 30 September 1983 Resolved
ATTACH A 100 FOOT PAINTER TO THE LIFE FLOATS WITH A WEAK LINK CONNECTED TO THE DECK.
Condition: Unknown
Due 30 September 1983
Resolved 30 September 1983
Unknown
Issued 30 September 1983 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE DESTINY, DN612066.
Condition: Unknown
Due 30 September 1983
Resolved 30 September 1983

Casualty record · 1

12 May 2004Routine · role: Involved in a Marine Casualty · activity 2078874
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

C/RENEGADE (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record