Records from 1985 to 2007. Most recent: inspection, 2 February 2007.
Inspection history · 118
2 February 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2866026
26 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2862316
10 January 2007
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2853810
21 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2438978
3 June 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2378446
29 May 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2375377
16 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2337248
26 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2248457
25 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2256148
8 September 2004
COC-GAS Annual
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2190679
13 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2131969
13 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2024672
10 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1981940
4 November 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1942044
1 September 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1909523
20 March 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1760235
19 March 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1759660
10 March 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1755584
9 March 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1755169
25 February 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1749819
18 February 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745961
11 February 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1743530
31 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1738930
19 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1733218
11 January 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1729066
8 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1728914
30 December 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1728039
29 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1724802
15 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1720231
5 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1714807
24 November 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1710038
23 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1710294
18 November 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1706933
12 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1705171
24 October 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1697034
20 October 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1694090
9 October 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1687495
4 October 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1695427
25 September 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1680686
12 September 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1676037
2 September 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1670025
23 August 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1665544
21 August 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1666834
13 August 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1660778
2 August 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1655985
30 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1656143
14 July 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1657756
13 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1646400
10 July 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1648826
1 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1642751
15 June 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1643050
6 June 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1627282
6 June 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1627482
26 May 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1622004
14 May 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1616529
1 May 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1617155
21 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1607478
11 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1604019
1 April 2002
Administrative Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1599780
1 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1600484
20 March 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1495347
11 March 2002
Security Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1492740
10 March 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1492735
27 February 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1490125
16 February 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1487355
6 February 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1484772
28 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1481772
25 January 2002
In-Service Inspection · Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1481592
16 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1479350
10 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1477301
10 January 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1477574
9 December 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 296167
27 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295879
18 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295626
9 November 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295387
8 November 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296178
30 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295115
29 October 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295134
19 October 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294851
8 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294507
29 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294223
19 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293892
9 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293624
26 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293252
26 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1076537
5 May 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 428262
28 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25350
4 February 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1108637
3 February 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412469
2 February 1998
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 785729
23 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405985
4 December 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 398273
15 November 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 397479
1 September 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 395801
26 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 394744
19 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 386891
20 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384320
20 October 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1188810
10 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 686563
2 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 109148
12 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382709
3 August 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 842832
17 July 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 359513
17 July 1993
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 845065
9 July 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 647516
30 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 105418
21 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463206
7 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 949085
27 August 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1253255
6 August 1989
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1039342
28 March 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 451411
27 June 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 324181
15 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 489736
2 September 1987
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002350
4 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022035
4 May 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329762
4 February 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 538005
7 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 300682
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2007
Resolved
The deck plating support on the anchor platform is completely wasted.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "The anchor platform support was repaired accordingly."
Construction/Loadline › Structures › Deck Plating
Issued 10 January 2007
Resolved
Various guard rails on catwalk are wasted and missing.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "The wasted & missing guard rails on catwalk have been repaired by cropping and renew, as per indication in the USCG PSC report of inspection."
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 10 January 2007
Resolved
Deck water spray system is not receiving enough pressure to activate the nozzels above tank #1.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2007
Resolution: Crew cleared stopped up nozzels and fixed various leaks on system while inspectors were still on sight.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 10 January 2007
Resolved
Temperature gauges on cargo tanks #2 and #5 are cracked.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "Temperature gauges glass cracked from no.2 and no. 5 cargo tanks have been replaced."
Deck/Cargo › Cargo Transfer (solid) › General
Issued 10 January 2007
Resolved
The hand wheel for the group #1 valve on top of cargo tank #3 is missing.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "The hand wheel for group #1 valve on top of #3 cargo tank was repaired accordingly."
Deck/Cargo › Cargo Transfer (solid) › General
Issued 10 January 2007
Resolved
The #2 cargo tank chiller ground line insulation is wasted.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "The no. 2 cargo tank chiller group line insulation have been repaired."
Deck/Cargo › Cargo Transfer (solid) › General
Issued 10 January 2007
Resolved
Various studs on couplings of the electric conduit line are completly wasted.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "electric conduct line were replaced due to wasted."
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 January 2007
Resolved
The fire control plan has not designated the various fire sections enclosed by class "A" divisions or class "B" divisions.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "Fire control plan has been marked/indicated the various enclosed by "A" class divisions with red color and by "B" class yellow color accordingly."
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 January 2007
Resolved
Fire doors fail to close and latch providing the proper seal for smoke and flame.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 1 February 2007
Resolution: Class report states "Fire doors have been repaired in order to close and lash providing a seal for smoke & flame properly."
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 8 September 2004
Resolved
Fixed gas detection system not operating properly. Meters and alarms for several sampling inoperable. Existing gas code 13.6.8
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2004
Resolution: Class report attesting to non-working sensors replaced and tested satisfactorily.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 8 September 2004
Resolved
Vacuum alarms unable to be tested. Repair to the satisfaction of Class by next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 September 2004
Resolution: Rcvd Class report attesting to satisfactory test of vacuum alarms.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 8 September 2004
Resolved
Wasted piping on deck water spray line. Deck water spray piping has been addressed by Class and a temporary repair has been made, but deficiency is still outstanding and should be corrected by 22Sep04.
Action required: 705 - Other - as specified
Due 22 September 2004
Resolved 15 October 2004
Resolution: Rcvd Class report attesting to satisfactory repair of deck water spray piping.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 1 September 2003
Resolved
Paint was found on all fusible links serving cargo tank domes on main cargo weather deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2003
Resolved 4 November 2003
Resolution: Verified repairs and received NKK class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 1 September 2003
Resolved
Quick closing valves did not close within the prescribed 30 secon timeframe. LEGACY COMPONENT DESC: Emergency Shut-down
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2003
Resolved 4 November 2003
Resolution: Verified valve closures and received NKK class report.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 August 2002
Resolved
Inoperable turbocharger: Make repairs to turbocharger & test to satisfaction of Safety Construction Certificate issuing authority. LEGACY COMPONENT DESC: Turbocharger
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2002
Resolved 2 August 2002
Resolution: Received Class (NKK) rpt attesting to satisfactory repairs.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 July 2002
Resolved
Inoperable turbocharger on the vsl's main engine rendering a max ahead speed of 7.5 knots. Make permanent repairs to the satisfaction of the Safety Construction Certificate Issuing Authority prior to the departure from the Port of Houston. LEGACY COMPONENT DESC: Turbocharger
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 2 August 2002
Resolution: COTP order cancelled after receiving notification that the turbocharger on the main engine had been repaired.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 July 2002
Resolved
Vessel suffered a reduction in propulsion due to inoperative main diesel engine turbogenerator, 33CFR160.111. Provide class report attesting to the satisfactory repair of the turbogenerator or a proposal for repairs. LEGACY COMPONENT DESC: Turbocharger
Due 18 July 2002
Resolved 23 August 2002
Resolution: Deficiency correction was verified during annual exam. Zero remaining deficiencies.
Unknown
Issued 26 August 2001
Resolved
Prior to departure have all hydraulic oil in steering gear room removed.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Deck/Cargo
Issued 26 August 2001
Resolved
Prior to loading cargo in deck tanks, repair and prove proper operation of high level alarms.
Condition: Unknown
Due 28 September 2001
Resolved 1 April 2002
Resolution: corrected
Fire Fighting
Issued 26 August 2001
Resolved
Prior to loading cargo, prove adequate pressure from all water washdown nozzles.
Condition: Unknown
Due 27 August 2001
Resolved 4 September 2001
Deck/Cargo
Issued 26 August 2001
Resolved
Prior to loading cargo, repair and prove proper operation of high level alarms on cargo tanks one through five.
Condition: Unknown
Due 28 August 2001
Resolved 4 September 2001
Deck/Cargo
Issued 26 August 2001
Resolved
Prior to loading cargo, prove proper settings and operation of all cargo tank safety relief valves.
Condition: Unknown
Due 28 August 2001
Resolved 4 September 2001
Unknown
Issued 26 August 2001
Resolved
Prior to next U.S. port, repair self closing doors in main stairtower and door closure for emergency fire pump space.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Lifesaving
Issued 26 August 2001
Resolved
Prior to departing Houston-Galveston zone, provide unexpired epirb onboard vessel.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Deck/Cargo
Issued 26 August 2001
Resolved
Prior to loading cargo requiring inert conditions, provide Class Report attesting to the proper operation and alarm function test of Inert Gas System.
Condition: Unknown
Due 28 September 2001
Resolved 1 April 2002
Resolution: corrected
Fire Fighting
Issued 3 February 1998
Resolved
Demonstrate adequate emergency fire pump pressure through two jets of waterand provide Class (NKK) Surveyor's Report on behalf of Flag State attestingto correction of deficiency and satisfactory testing prior to departure IAWSOLAS 74, Chapter II-2, Regulation 52.
Condition: Unknown
Due 5 February 1998
Resolved 5 February 1998
Fire Fighting
Issued 3 February 1998
Resolved
REPAIR LEAKING EXHAUST GAS PIPE FOR EMERGENCY FIRE PUMP IAW SOLAS 74, CHAPTER I, REGULATION 11 NLT 04MAR98.
Condition: Unknown
Due 5 February 1998
Resolved 5 February 1998
Deck/Cargo
Issued 23 July 1997
Resolved
PROVIDE CLASS DOCUMENTATION ON CARGO TANK SAFETY RELIEF VALVES SEALED BY CLASS.
Condition: Unknown
Due 6 February 1998
Resolved 6 February 1998
Accommodation/Occupational Safety
Issued 23 July 1997
Resolved
REPAIR GASKET ON WATER TIGHT DOOR PORT SIDE TO CARGO COMPRESSOR ROOM.
Condition: Unknown
Due 6 February 1998
Resolved 6 February 1998
Deck/Cargo
Issued 23 July 1997
Resolved
REPAIR SALT WATER COOLING SUPPLY LINE FOR CARGO COMPRESSOR LOCATED IN ELECTRIC MOTOR ROOM.
Condition: Unknown
Due 6 February 1998
Resolved 6 February 1998
Unknown
Issued 15 November 1996
Resolved
OUTDATED FIXED FIREFIGHTING SERVICE CERTIFICATES. (SOLAS 74/78 II-2 6.5)_x001C_ ACTION REQ'D: PROVIDE CERTIFICATES TO USCG PRIOR TO 28 NOV 96
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Lifesaving
Issued 15 November 1996
Resolved
OUTDATED EEBA/SCBA SERVICING CERTIFICATES.(VIOLATION OF GAS CODE 14.7)_x001C_ ACTION TAKEN: PROVIDE CERTIFICATES TO USCG PRIOR TO 28 NOV 96.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Documentation
Issued 15 November 1996
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. (33CFR155.720)_x001C_ ACTION REQ'D: PROVIDE TO USCG PRIOR TO 28NOV96.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Lifesaving
Issued 26 August 1996
Resolved
PORT AND STARBOARD LIFEBOAT EMBARKATION LADDERS WEATHERED.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Accommodation/Occupational Safety
Issued 26 August 1996
Resolved
A CREWMEMBER WAS LIVING IN THE HOSPITAL SPACE.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Accommodation/Occupational Safety
Issued 26 August 1996
Resolved
REPAIR OR REPLACE THE CREW'S WASHERS AND DRYERS.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Accommodation/Occupational Safety
Issued 26 August 1996
Resolved
CREW'S TOILETS DID NOT FLUSH CREATING A VERY UNHEALTHY LIVING ENVIRONMENT.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Deck/Cargo
Issued 20 October 1995
Resolved
PROVIDE FLAG STATE REPORT OF CARGO RESTRICTIONS DUE TO THE PRESENT INOPERABLE CONDITION OF THE INERT GAS PLANT FOR ALL CARGOES LISTED ON THE CURRENT CERTIFICATE OF FITNESS._x001C_ GAS CARRIER CODE 13.2
Condition: Unknown
Due 20 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 20 October 1995
Resolved
WHEN CARGOS REQUIRING ENVIRONMENTAL CONTROL FOR THE INTERBARRIER SPACES; IE, INERT GAS PAD, IN U.S. WATERS ARE CARRIED PROVIDE ADEQUATE INERT GAS TOMAINTAIN THE PAD FOR 30 DAYS EITHER BY STORED GAS OR AN INERT GAS GENERATOR. GAS CARRIER CODE 13.2
Condition: Unknown
Due 20 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 20 October 1995
Resolved
PROVIDE ACCURATE CALCULATIONS SHOWING THE REQUIRED INTER GAS TO MAINTAIN ANINERT GAS PAD ON THE ENVIRONMENTALLY CONTROLLED INTERBARRIER SPACES FOR 30 DAYS._x001C_ GAS CARRIER CODE 13
Condition: Unknown
Due 20 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 20 October 1995
Resolved
PROVIDE FLAG STATE VERIFICATION OF WHAT DOCUMENTATION IS REQUIRED TO SATISFY THE MINIMUM SAFE MANNING CERTIFICATE REQUIREMENT THAT AN A.B. SEAMAN OR QUALIFIED MECHANIC IS A QUALIFIED PUMPMAN._x001C_ ILO 147 ANNEX I, RESOLUTION A.481 (XIII)
Condition: Unknown
Due 20 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 20 October 1995
Resolved
PROVIDE CARGO COMPRESSOR LOW PRESSURE ALARMS & COMPRSSOR SHUTDOWNS OR VACUUM RELIEF VALVES, WHEN OPERATING THE CARGO COMPRESSORS IN U.S. WATERS._x001C__x001C_ 46CFR154.804
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Fire Fighting
Issued 12 September 1995
Resolved
PRIOR TO RECEIVING A LETTER OF COMPLIANCE: REPLACE ALL MISSING NOZZELS IN THE DECK WATER SPRAY SYSTEM. _x001C_ _x001C_ GAS CODE 11.3
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
PRIOR TO RECEIVING A LETTER OF COMPLIANCE: MAKE PERMANENT REPAIRS TO SOFT PATCHES ON THE DECK WATER SPRAY.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Deck/Cargo
Issued 12 September 1995
Resolved
PRIOR TO RECEIVING A LETTER OF COMPLIANCE: PROVIDE SPAN GAS AND PROVE CALIBRATION/AND OPERATION OF THE GAS DETECTION SYSTEM. _x001C_ _x001C_ GAS CODE 13.6
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Deck/Cargo
Issued 12 September 1995
Resolved
PRIOR TO RECEIVING A LETTER OF COMPLIANCE: PROVE OPERATION OF THE OXYGEN ANALYZER ON THE INERT GAS SYSTEM._x001C_ _x001C_ 46CFR32.53
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
PROVIDE A DECK SPRAY SYSTEM WITH NOZZELS CAPABLE OF FREE FLOW OF WATER. NOZZELS ON PORT SIDE AMIDSHIPS ARE CLOGGED. ITEM TO BE COMPLETED PRIOR TO CARGO TRANSFER. GAS CODE 11-3.
Condition: Unknown
Due 12 September 1995
Resolved 2 October 1995
Deck/Cargo
Issued 12 September 1995
Resolved
PROVIDE EXPIRATION DATE FOR INHIBITOR ADDED TO CARGO OF BUTADINE ADDED ON 8-30-95. ITEM TO BE COMPLETED PRIOR TO TRANSFER OF CARGO. GAS CODE 17.10.
Condition: Unknown
Due 12 September 1995
Resolved 2 October 1995
Deck/Cargo
Issued 12 September 1995
Resolved
PROVIDE OIL FOR OILS SEALS IN MOTOR ROOM.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
PROVE OPERATION OF EMERGENCY FIRE PUMP
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Navigation
Issued 12 September 1995
Resolved
PROVE OPERATION OF STEERING GEAR LOSS OF POWER ALARMS
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
REMOVE PAINT FROM THE FUSIBLE PLUGS AT EACH CARGO TANK
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
PROVIDE FLASHLIGHTS FOR THE FIREMAN'S OUTFITS
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Fire Fighting
Issued 12 September 1995
Resolved
PROVIDE TENDING LINES FOR THE FIREMAN'S OUTFITS
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Deck/Cargo
Issued 12 September 1995
Resolved
MAKE QUICK CLOSING VALVES OPERATE PROPERLY. ALL VALVES SHOULD CLOSE WITHIN30 SECONDS. ITEM TO BE COMPLETED PRIOR TO TRANSFER OF CARGO. GAS CODE 5-3
Condition: Unknown
Due 12 September 1995
Resolved 2 October 1995
Deck/Cargo
Issued 17 July 1993
Resolved
PROVIDE PROPERLY OPERATING LIQUID HIGH TEMP INDICATORS AND ALARMS FOR CARGOTANKS #1,3,4 & 5. _x001C_
Condition: Unknown
Due 17 July 1993
Resolved 17 July 1993
Deck/Cargo
Issued 17 July 1993
Resolved
PROVIDE PROPERLY OPERATING VAPOR HIGH TEMP INDICATOR AND ALARM FOR CARGO TANK #4.
Condition: Unknown
Due 17 July 1993
Resolved 17 July 1993
Deck/Cargo
Issued 17 July 1993
Resolved
MAKE INERT GAS SYSTEM AVAILABLE FOR COAST GUARD INSPECTION PRIOR TO PLACINGINTO OPERATION.
Condition: Unknown
Due 17 July 1993
Resolved 17 July 1993
Fire Fighting
Issued 27 June 1988
Resolved
PROVIDE REPAIRS TO THE SPRINKLER SYSTEM NOZZLES ON BOARD AND PROVE PROPER OPERATION.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Unknown
Issued 7 March 1985
Resolved
RELABEL OR REPAINT WHERE NECESSARY ALL QUICK CLOSING VALVE VISUAL INDICATORS.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Navigation
Issued 7 March 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Unknown
Issued 7 March 1985
Resolved
REMOVE WIRE ROPE IN WAY OF SMALL DIAMETER PIPE IN THE MOTOR ROOM USED TO DAMPEN VIBRATION OF ADJACENT MACHINERY
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985