Records from 1999 to 2012. Most recent: inspection, 10 February 2012.
Inspection history · 53
10 February 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4241951
26 January 2012
Ballast Water Examination · ISPS III Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4226952
13 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4143724
13 September 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4145659
13 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4145681
30 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4130823
29 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4130249
10 October 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3862450
10 October 2010
COE-Offshore · Ballast Water Examination · COC-TVE Renew · ISPS I Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3863549
30 September 2008
MARPOL Annex V Examination · COC-TVE Annual · MARPOL Annex I Examination · NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3335312
5 September 2008
NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3307224
29 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3307223
29 August 2008
Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 3355997
25 October 2007
MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3085595
15 February 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2872802
18 January 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2858131
24 September 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2785738
22 September 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2784530
22 September 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2794943
21 August 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2758424
23 July 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2721646
21 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2687117
1 May 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2639094
27 April 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2635323
27 April 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2645453
8 December 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2548032
23 November 2005
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2539861
21 November 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2540156
7 July 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2418214
8 April 2005
Spot Check · Random ISPS/MTSA/PSC
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2331522
21 December 2004
PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2263283
14 December 2004
ISPS III Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2258859
13 December 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2258558
13 December 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308062
10 December 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257265
12 September 2004
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2193117
23 July 2004
ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2140156
1 March 2004
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2016267
24 September 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1916146
15 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1905196
28 February 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1746128
7 October 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1685939
18 April 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1604910
23 January 2002
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1480822
29 December 2001
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1474807
29 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294220
29 September 2001
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074079
28 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073683
9 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288977
30 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283565
10 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 279725
24 February 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 178362
18 November 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434833
Fire Fighting › Fixed Deck Foam System › Piping
Issued 26 January 2012
Resolved
1850-Fire Protection cargo deck area-Any change after the survey must be sanctioned by the administration. PSCO discovered a 3/4" by 1" hole in the piping for the #4 foam monitor. As a temporary repair crew installed a clamp and soft patch. Provide documentation from the certificate issuing authority attesting to satisfactory repair.-SOLAS74a I/11.
Action required: 705 - Other - as specified
Due 9 February 2012
Resolved 10 February 2012
Resolution: Received class report from ABS satisfying the requirement.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 26 January 2012
Resolved
0615-Rescue Boats-Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min. Crew was unable to start the rescue boat engine to meet the launching time requirements.
Action required: 705 - Other - as specified
Due 26 January 2012
Resolved 26 January 2012
Resolution: Crew was able to dry out the engines electrical system which experienced heavy downpour of rain the morning before the CG''s arrival. In result the engine started and ran on it''s own fuel supply to the satisfaction of the PSCO.
Engineering › Steering Gear System › Motor
Issued 13 September 2011
Resolved
The vessel experienced a steering loss while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2011
Resolved 14 September 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the steering gear motor was repaired, tested and found satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 30 August 2011
Resolved
Two (2) solenoid valves were sticking/faulty.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Resolution: Solenoid valves were replaced.
Engineering › Compressed Air System (start air) › Valve
Issued 29 August 2011
Resolved
Start air valve found to be inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Resolution: Unit replaced.
Engineering › Freshwater System (piston cooling) › Containment
Issued 18 January 2007
Resolved
Cylinder cooling water leaking out of propulsion main engine cylinders of #1 and #3 leaking due to failure of O-rings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 15 February 2007
Resolution: Recieved class report attesting to the repair of the leaking cooling water on the main diesel engine.
Construction/Loadline › Hull › Bottom Plating
Issued 27 April 2006
Resolved
CODE: 9800. Prior to departing the Port of Guayanilla, PR provide attestation from the vessel's Classification Society that the vessel is fit for safe service. The Class report is required because of the vessel running aground offshore of Guayanilla, PR on 27Apr06. The report may be faxed to [phone withheld]. Contact [name withheld] at [phone withheld] w/ questions/comments.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2006
Resolved 30 April 2006
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 14 December 2004
Resolved
The tankship liquid overfill protection loss of power alarm could not be demonstrated. Provide class report attesting to proper operation. The vessel is prohibited from loading and or use of the Vapor Recovery System until the loss of power alarm is demonstrated to a CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 December 2004
Resolved 21 December 2004
Resolution: Received tech report from Radio Holland satisfying requirement.