MAURY USCG vessel records Sign in
← All vessels

GIS-CRUSADER

GIS-CRUSADER is a 1979 offshore supply vessel. The Coast Guard has recorded 49 inspections since 1982, most recently in March 2014, along with 59 deficiencies and 1 casualty investigation in 2013.

Records from 1982 to 2014. Most recent: inspection, 19 March 2014.

Built
1979
Last inspected
19 March 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6000
Flag
UNITED STATES
367012310, 367299060, 367552470 (licence lapsed)
Maury page id
psix-50449

Inspections, by type

…with no type recorded15
Years with a record 26 calendar years (1982–2014)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG6000MMSI 367552470 · expired · compulsorily equipped · granted 3 November 2012, cancelled 7 January 2023
WDD8508MMSI 367299060 · expired · voluntarily equipped · granted 26 June 2007, cancelled 26 August 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC3673MMSI 367012310 · expired · voluntarily equipped · granted 19 January 2005, cancelled 21 March 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCR2321MMSI not assigned · expired · voluntarily equipped · granted 1 May 1995, cancelled 2 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BEST WON Passenger (Inspected) · MISLE 363102 · 26 September 2004 · activity 2338272

Inspection history · 49

19 March 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4819169
30 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3480122
2 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3336996
23 September 2008 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330776
17 November 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2536682
13 October 2005 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2513398
15 September 2005 Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2493450
16 November 2004 Annual Inspection · Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2243402
26 September 2004 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2338272
14 July 2003 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1845990
4 October 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1684546
16 August 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1666551
9 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406925
26 July 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410387
17 May 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817797
16 May 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 162181
5 May 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369149
5 November 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804903
17 September 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804626
30 July 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470956
6 June 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402472
13 March 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360443
30 March 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 861695
21 March 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449802
9 February 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148185
12 April 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431352
7 June 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141325
19 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379740
13 April 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265302
22 March 1991 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219000
26 April 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 920041
24 March 1989 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1348503
23 March 1988 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 985566
6 May 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1018604
22 April 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315072
21 March 1987 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1328614
22 December 1986 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027241
26 March 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1304890
19 March 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 994284
10 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289289
4 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979953
23 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 980859
7 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285568
17 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288576
27 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284016
20 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977457
2 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279467
20 December 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280107
19 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274674

Deficiency record · 59

Communications › Alarms/Indicators › General Alarm
Issued 19 March 2014 Resolved
The General alarm speaker box in the engine room is the wrong voltage. When alarm is activated the speaker has smoke coming from it. Speaker has been removed and a new speaker will be installed. All repairs will be done to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2014
Resolved 10 April 2014
Resolution: Attended vsl to sound check new general alarm speaker and sound checked the engine alarm speaker, all SAT.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 November 2004 Resolved
Overspeed failed to trip engine during test
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Replaced overspeed device, tested satisfactorily
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 16 November 2004 Resolved
F/O transfer pump leaking at metering device, electrical motor seal spinning freely on pump shaft
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Repaired all leaks and replaced seal on pump
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 16 November 2004 Resolved
Stbd MDE, F/O leak on return side of F/O system
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Replaced hose & fittings
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 November 2004 Resolved
Excessive L/O and F/O in engineroom bilges
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 17 November 2004
Resolution: Pumped out engine room bilges, visually inspected satisfactorily during 30Nov def check.
Deck/Cargo › Ballast › Piping
Issued 16 November 2004 Resolved
Crop and renew lower pipe, and replace valve, on piping to aft void tank
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Piping renewed, new valve installed
Engineering › Fuel Oil Service System › Filter
Issued 16 November 2004 Resolved
Port MDE, no flame sheild mounted on secondary fuel filter assembly
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: install new flame bowl
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 16 November 2004 Resolved
Stbd MDE, no air cleaner mounted on aft,in-board blower intake
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Installed new air intake
Construction/Loadline › Hull › Side Shell
Issued 16 November 2004 Resolved
Crop and renew inset in way of F/O transfer pump, stbd-fwd engine room
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 2 March 2005
Resolution: Item repaired, vessel changed ownership to International Boat Rentals
Communications › Radio Communications › EPIRB
Issued 16 November 2004 Resolved
EPIRB Battery expired
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2004
Resolved 16 November 2004
Resolution: Replaced battery
Communications › Radio Communications › EPIRB
Issued 16 November 2004 Resolved
EPIRB Hydrostatic release expired
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2004
Resolved 16 November 2004
Resolution: Replaced hydrostatic release
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2004 Resolved
All bridge electronic equipment plugged into electrical outlets, hardwire all bridge electronic equipment
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 17 November 2004
Resolution: Hard wired all electronics on bridge
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 November 2004 Resolved
Bilge alarm panel not labled
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: labled bridge bilge alarm panel
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 November 2004 Resolved
Port navigational light assembly not properly fastned to vessel (bailing wire is holding assembly in place)
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 18 November 2004
Resolution: Remounted nav light
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 16 November 2004 Resolved
Paint locker CO-2 expired, out of hydro
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 22 November 2004
Resolution: Replaced CO-2 cylinder
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 16 November 2004 Resolved
No established documentation to check for expiration, required testing, or calibration of safety equipment.
Action required: 705 - Other - as specified
Due 23 November 2004
Resolved 17 November 2004
Resolution: Established equipment log
Documentation › Certificates/Documents
Issued 4 September 2003 Resolved
Provide proof of the Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 27 October 2003
Electrical › Electrical Distribution System (service)
Issued 4 September 2003 Resolved
Provide switchboard safety interlock for circuit breakers. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 5 September 2003
Fire Fighting › Means of Escape
Issued 4 September 2003 Resolved
Stencil engine room emergency exit in galley. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 5 September 2003
Electrical › Lighting (emergency)
Issued 4 September 2003 Resolved
Install emergency light in galley. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 5 September 2003
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 September 2003 Resolved
Provide current tide tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 5 September 2003
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 4 September 2003 Resolved
Provide proof of operation for stbd generator over speed device. LEGACY COMPONENT DESC: Over speed Device
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 4 September 2003 Resolved
Label remote engine stops at aft operating station.
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Fire Fighting › Fire Pumps › Gland Sealing
Issued 4 September 2003 Resolved
Renew fire pump shaft seal.
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 4 September 2003 Resolved
Make stbd refrigerator ready for sea. LEGACY COMPONENT DESC: Refrigerator
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 5 September 2003
Engineering › Steering Gear System
Issued 4 September 2003 Resolved
Make repairs to #1 steering pump power failure alarm. LEGACY COMPONENT DESC: Steering Panel
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 4 September 2003 Resolved
Provide ventilation for the operating station back-up battery.
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 4 September 2003 Resolved
Provide collection bucket for dryer exhaust. LEGACY COMPONENT DESC: Laundry
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Navigation › Piloting/Steering › Marine Charts
Issued 4 September 2003 Resolved
Provide updated charts for operating area.
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 September 2003 Resolved
Route main engine oil pressure gauge lines to the correct gauge. LEGACY COMPONENT DESC: Gauges
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 5 September 2003
Communications › Alarms/Indicators
Issued 16 August 2002 Resolved
STEERING PUMP INDICATOR FOR #1 PUMP OOC. LEGACY COMPONENT DESC: STEERING PUMP INDICATOR
Due 16 September 2002
Resolved 16 August 2002
Engineering › Bilge Water Management System › Valve
Issued 16 August 2002 Resolved
FOREPEAK REACHROD BILGE VALVE INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2002
Resolved 16 August 2002
Documentation › Safety/Response Plans/Programs
Issued 16 August 2002 Resolved
NO FIRE SAFETY PLAN INSTALLED ON VESSEL.. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 16 September 2002
Resolved 16 September 2002
Resolution: POSTED REQUIRED SAFETY PLAN ON BOARD.
Construction/Loadline › Structures
Issued 16 August 2002 Resolved
MAKE TEMPORARY REPAIRS TO AFT STBD TRANSVERSE BULKHEAD IWO STBD SHAFT AND BOTTOM PLATING. CONDUCT PERMANENT REPAIRS PRIOR TO 09/16/02 TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 16 September 2002
Resolved 16 September 2002
Resolution: VESSEL DRYDOCKED AND PERMANENT REPAIRS MADE IWO STBD SHAFT AREA BOTTOM PLATING BY INSERTING 18"X20" 3/8" PLATING.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 16 August 2002 Resolved
LOCAL NOTICE TO MARINERS NOT PROVIDED.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2002
Resolved 16 August 2002
Construction/Loadline
Issued 30 July 1998 Resolved
CROP AND RENEW AS ORIGINAL DIRTY OIL TANK TOP.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Documentation
Issued 21 March 1995 Resolved
PROVIDE ON BOARD ORIGINAL CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Navigation
Issued 19 February 1993 Resolved
PROVIDE ON BOARD RUDDER ANGLE INDICATOR. INSTALL AND DEMONSTRATE _x001C_ SATISFACTORY OPERATION TO COGNIZANT OCMI.
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Lifesaving
Issued 21 March 1987 Resolved
PROVIDE TWO (02) SIX FT. BOAT-HOOKS FOR THE LIFEFLOATS.
Condition: Unknown
Due 21 March 1987
Resolved 21 March 1987
Electrical
Issued 21 March 1987 Resolved
MAKE PERMANENT REPAIRS TO THE PORT GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 21 March 1987
Resolved 21 March 1987
Engineering
Issued 21 March 1987 Resolved
MAKE PERMANENT REPAIRS AND TEST BOTH MAIN ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 21 March 1987
Resolved 21 March 1987
Electrical
Issued 21 March 1987 Resolved
MAKE PERMANENT REPAIRS TO THE AFT ALTERNATE STEERING STATION SOUND POWERED PHONE SYSTEM BELL.
Condition: Unknown
Due 21 March 1987
Resolved 21 March 1987
Electrical
Issued 21 March 1987 Resolved
MAKE PERMANENT REPAIRS TO THE ENGINE ROOM SOUND POWERED PHONE SYSTEM AND LIGHT AND BELL.
Condition: Unknown
Due 21 March 1987
Resolved 21 March 1987
Documentation
Issued 19 March 1986 Resolved
SUBMIT TO [name withheld], TEXAS, AN APPLICATION FOR REDUCED MANNING WHILEUTILIZING OFFSHORE MOORING BUOYS.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Navigation
Issued 19 March 1986 Resolved
REINSTATE THE RUDDER ANGLE INDICATORS IN THE PILOT HOUSE AND THE AFTER STEERING STATION.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Navigation
Issued 19 March 1986 Resolved
PROVIDE ONBOARD A CURRENT COPY OF VOLUME 2 OF THE COAST GUARD LIGHT LIST.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Electrical
Issued 19 March 1986 Resolved
MAKE OPERABLE THE BELL ON THE SOUND POWERED TELEPHONE IN THE ENGINEROOM.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Electrical
Issued 19 March 1986 Resolved
INSTALL A BATTERY BOX ON THE RADIO BATTERY IN THE WHEELHOUSE.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Fire Fighting
Issued 19 March 1986 Resolved
INSTALL A FIXED CO2 EXTINGUISHING SYSTEM OF AN APPROPRIATE SIZE ON THE PAINT LOCKER.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Lifesaving
Issued 4 April 1985 Resolved
NO MORE THAN 17 TOTAL PERSONS ARE TO BE CARRIED UNITL THREE ADDITIONAL LIFEPRESERVERS WITH LIGHTS ARE PROVIDED.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Accommodation/Occupational Safety
Issued 4 April 1985 Resolved
MAKE OPERABLE THE REMOTE MACHINERY SPACE BLOWER SHUTDOWN.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Lifesaving
Issued 4 April 1985 Resolved
STENCIL THE VESSEL'S NAME ON THE ONE 12-MAN LIFEFLOAT.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Construction/Loadline
Issued 23 March 1985 Resolved
PRIOR TO DEPARTING H & H SHIPYARD, BRIDGE CITY, TEXAS, REPAINT ALL DRAFT MARKS, VESSEL NAME, AND HAILING PORT.
Condition: Unknown
Due 23 March 1985
Resolved 23 March 1985
Navigation
Issued 7 March 1985 Resolved
REPAIR ALL THE ATTACHMENT POINTS ON STEERING MECHANISM TO REMOVE SLACK.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 20 December 1984 Resolved
REPLACE THE LIGHT GLOBES IN THE ENGINE ROOM AND UPPER CREW'S HEAD.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Lifesaving
Issued 20 December 1984 Resolved
THE VESSEL IS LIMITED TO TEN (10) PERSONS ON BOARD UNTIL TEN (10) MORE LIGHTS ARE ATTACHED TO THE PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Engineering
Issued 20 December 1984 Resolved
MAKE NECESSARY REPAIRS TO THE OVERSPEED TRIPS TO ENSURE PROPER OPERATION.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1983 Resolved
REMOVE OR REPAIR THE DEFECTIVE RUDDER ANGLE INDICATORS IN THE WHEELHOUSE AND AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 20 December 1983
Resolved 20 December 1983
Unknown
Issued 20 December 1983 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE ARGOSY CRUSADER, DN613095.
Condition: Unknown
Due 20 December 1983
Resolved 20 December 1983

Casualty record · 1

11 April 2013Routine · role: Involved in a Marine Casualty · activity 4573189
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.