Records from 2016 to 2026. Most recent: inspection, 16 June 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 August 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI observed port engine RPM gauge at operating station is inoperable. Vessel to repair/replace with indication it is operating as designed.
46 CFR 182.410(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 26 August 2025
Resolution: Vessel repaired operating station RPM gauge. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 August 2025
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. For each alternating current generator, a means for measuring frequency must also be provided. Ammeter and frequency meter on generator switchboard does not operate. Vessel to repair/replace with indication it is operating as designed.
46 CFR 183.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 26 August 2025
Resolution: Frequency and Ammeter operate satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Generator operating with un-usual noise indicating a possible belt failure. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 26 August 2025
Resolution: Generator operating with no un-usual noise, as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 July 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Attending MI discovered insufficient electrical power for operation of main and auxiliary propulsion systems and associated equipment.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2024
Resolution: Batteries replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 July 2024
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Attending MI discovered fixed fire extinguishing system that failed to shut down the vessels generator during test. Vessel is restricted from operation of generator until deficiency has been rectified.
Action required: 705 - Other - as specified
Resolved 5 August 2024
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Attending MI discovered penetrations through the forward, starboard, main engine room watertight bulkhead that were not sealed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2024
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2024
Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Attending MI discovered plastic wire tie wraps holding wires in the starboard side void below passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2024
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2024
Resolved
As appropriate for the intended voyage, a vessel must carry an adequate and up-to-date Coast Guard Light List.
Attending MI discovered out of date Coast Guard Light List.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Attending MI discovered loose wiring protruding from MDE that was not properly terminated and secured at electrical connection end of wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2024
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 24 July 2023
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel operator failed to conduct drill in safe manner as described by companies written procedures on board vessel. Conduct man overboard drill in accordance with company procedures to the satisfaction of the CG marine inspector. 46 CFR 176.808 (g)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 August 2023
Resolution: Observed satisfactory MOB drill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessels passenger compartment bilge pump indicator light was non operational. Repair or replace with in kind. 46 CFR 182.530 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Observed operational bilge pump indicator light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. MI discovered fuel leak on generator fuel line. Replace with in kind. 46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Operational test of generator test, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2023
Resolved
At least one ring buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must: (2) Be of at least 60 feet in length. Vessels ring buoy life ring not 60 feet in length. Fit life buoy with correct length lifeline.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Life buoy fitted with correct length line.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Vessels radio over current protection device was of unapproved type. Replace with approved over current device. 46 CFR 183.380 (k)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Approved overcurrent device installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2023
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Vessels generator voltmeter was inoperable. Repair or replace in kind. 46 CFR 183.320(c)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: New voltmeter installed on vessel switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2023
Resolved
Each generator must have a nameplate attached to it containing the information required by Article 445 of NFPA 70. Vessels generator was missing nameplate. Install proper nameplate. 46 CFR 183.320 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2023
Resolution: Reviewed installed data plate for vessel generator.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessels pilothouse extinguisher bracket was severely corroded and not supporting fire extinguisher. Replace with in kind. 46 CFR 176.810 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Vessel installed new fire extinguisher bracket.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 July 2023
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weather tight: A hatch on a vessel that operates only on protected waters. Vessels port side topside machinery space hatch had missing gasket material. Repair or replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2023
Resolution: Vessel installed new gasket material for machinery space hatch.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 September 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. 46CFR177.100. Vessel was reported damaged during hurrican IDA. USCG requires a salvage plan, transit plan and/or damage survey approved by our office or the “cognizant OCMI” prior to transit or return to service.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 October 2021
Resolution: The vessel is in drydock getting repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 October 2020
Resolved
46 CFR 176.500 (b)(1):Vessel is required to have a satisfactory annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is past due for annual inspection. Vessel must have satisfactory annual inspection conducted and a plan for prevention of future lapses in meeting annual inspection deadlines.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2020
Resolved 2 November 2020
Resolution: Vessel had a satisfactory Annual inspection 02Nov2020.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Non-captive type electrical connections found under the navigation console panel. Within 7 days, correct to satisfaction of CG marine inspector.
Action required: 705 - Other - as specified
Due 9 October 2019
Resolved 22 October 2019
Resolution: Owner replaced non-captive electrical connections with captive connections.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 September 2019
Resolved
Bulkhead between engine room and cabin void found to have open cable penetration. Within 7 days, correct to satisfaction of CG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2019
Resolved 22 October 2019
Resolution: Owner incerted a proper vapor tight fitting in the bulkhead.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 April 2019
Resolved
BILGES MUST BE FREE AND CLEAR, DISCOVERED EXCESSIVE AMOUNTS OF OILY WATER IN ENGINE ROOM BILGE. CORRECT TO SATISFACTION OF CG MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 May 2019
Resolved 6 May 2019
Resolution: All oily water was satisfactorily removed from bilge.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 April 2019
Resolved
FIXED FIREFIGHTING SYSTEM MUST BE SERVICED ANNUALLY. SERVICING DATE EXPIRED JANUARY 2019. CORRECT TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2019
Resolution: Operator provided report of servicing, dated 4/22/19.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 April 2019
Resolved
NAVIGATION LIGHTS MUST BE OPERABLE, ANCHOR LIGHT NOT FUNCTIONING. CORRECT TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2019
Resolution: Bulb was replaced and operator demonstrated satisfactory operation of anchor light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
AUXILLIARY MACHINERY MUST OPERATE SATISFACTORILY. HYDRAULIC ENGINE CONTROL UNIT UNDER OPERATING STATION HAS MULTIPLE LEAKS AT FITTINGS. CORRECT TO SATISFACTION OF CG MARINE INSPECTOR.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2019
Resolution: Control unit's seals were blown, entire unit was replaced, fittings were tightened, cleaned and demonstrated leak free operation.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 5 June 2017
Resolved
Marine Inspector could not verify operation of the starboard engine. Prior to operation of vessel, identify cause of engine issue and repair to satisfaction of attending marine inspector. 46 CFR 182.200 (Prior to Operation)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 6 June 2017
Resolution: Witnessed satisfactory operation of starboard engine. Conducted operational tests; all sat.
Construction/Loadline › Hull › Weld
Issued 5 June 2017
Resolved
Marine Inspector identified cracked weld in port exhaust between engine room and lazarette. Grind and reweld to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 6 June 2017
Resolution: Inspected repaired weld on port side engine room exhaust; all sat.