Records from 1999 to 2004. Most recent: inspection, 9 February 2004.
Engineering › Compressed Air System (control)
Issued 9 December 2003
Resolved
Clean and gage or replace in kind. If gauged, provide original thickness, U1A report.
Pop off valve (PRV) - provide test data or replace in kind
Pressure gage - Glass lens cracked
LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 4 March 2004
Lifesaving › Inflatable Liferafts
Issued 17 October 2002
Resolved
Provide liferafts meeting manufactures suggested stowage hieght requirement. Due date extended on 835 to 31DEC02 on 18NOV02 by [name withheld] via e-mail dated 18NOV02 4:33pm. LEGACY COMPONENT DESC: Carriage Requirement
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 14 January 2003
Resolution: Installed life rafts with proper stowage height of 36 meters. Work done by [name withheld].
Engineering
Issued 24 October 2001
Resolved
Provide & install exhaust lagging for #1 ships service generator bellow assembly.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758
Electrical
Issued 24 October 2001
Resolved
Remove dead-end wire in wire tray above air compressor room & pump room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001
Resolved
Properly mount junction box located in overhead wire tray in pump room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001
Resolved
Renew deck grating next to welding shack & inspect condition of frames
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001
Resolved
Provide two certificated lifeboatmen designated for each lifeboat with a capacity greater than 40 persons IAW 46 CFR 109.323(c)(2).
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Navigation
Issued 24 October 2001
Resolved
Repair obstruction lighting - port side.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001
Resolved
Repair/renew handrail courses - starboard leg.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001
Resolved
Provide cable guard for pulley on brake system for both lifeboats.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001
Resolved
Prove proper operation of emergency lighting for watermaker room & pumproom.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Construction/Loadline
Issued 24 October 2001
Resolved
Properly adjust all dogs for mud pit room doors.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001
Resolved
Properly secure all electrical wiring/cable with metal straps throughout vessel (no plastic tie wraps).
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Deck/Cargo
Issued 24 October 2001
Resolved
Provide & install plugs/caps for all storage tank drain pipes.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001
Resolved
Repair/renew wasted food storage container in port lifeboat.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Engineering
Issued 24 October 2001
Resolved
Repair leaking fuel nozzle on #2 ships service generator located on #3 cylinder, right bank.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001
Resolved
Renew pyrotechnics in all line throwing apparatus.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Lifesaving
Issued 24 October 2001
Resolved
Repair cracks in canopy on port lifeboat IWO cradle support brackets. Repairs to be completed by authorized service facility.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Construction/Loadline
Issued 24 October 2001
Resolved
Repair wasted knife-edge combing around hospital space weather deck door.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001
Resolved
Provide guards for exposed bulbs in racks - various staterooms.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001
Resolved
Replace batteries in SARTs.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 24 October 2001
Resolved
Repair #4 agitator pump oil seal.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Engineering
Issued 24 October 2001
Resolved
Repair/replace exhaust lagging shield for #5 ships service generator exhaust piping located in Halliburton Room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 24 October 2001
Resolved
Make permanent repairs to 8 inch, 90 degree elbow recirculation line for #1& #2 eductor pumps.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001
Resolved
Repair/renew lower handrail course located on port leg.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 30 October 2000
Resolved
MAKE PERMANATE REPAIRS TO FIRE MAIN IWO #1 FIRE PUMP DISCHARGE DUE TO PIN HOLE LEAK.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Construction/Loadline
Issued 30 October 2000
Resolved
REMOVE DEBREE (CEMENT) FROM BILGE AREA IWO SUCTION STRAINERS.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Construction/Loadline
Issued 30 October 2000
Resolved
MAKE PERM. REPAIRS TO BILGE SUCTION ELBOW, REMOVE TEMP PATCH.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Electrical
Issued 1 November 1999
Resolved
CONDUCT THOROUGH INSPECTION OF ALL ELECTRICAL INSTALLATIONS IN SHALE SHAKERAREA UPON COMPLETION OF SAND BLASTING.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
UPON COMPLETION OF YARD WORK AND PRIOR TO DEPARTURE FROM YARD ENSURE ALL FIRE FIGHTING EQUIPMENT IS ON LOCATION IN ACCORDANCE WITH FIRE CONTROL PLAN.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 1 November 1999
Resolved
RECONFIGURE FUEL OIL SUPPLY AND RETURN LINES BETWEEN DAY TANK AND CEMENT SKID UNIT. NO SECTION OF FLEXIBLE PIPING CAN EXCEED 30 INCHES.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Electrical
Issued 1 November 1999
Resolved
INSTALL APPROVED LIGHT FIXTURE FOR STERN NAVIGATION LIGHT.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Unknown
Issued 1 November 1999
Resolved
INSTALL SAFETY RELIEF VALVES OF 100 PSI OR LESS ON HOT WATER HEATERS.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
System not recorded
Issued 1 November 1999
Resolved
ADDRESS MARINE GROWTH ON LEG ESCAPE LADDERS.
Condition: Unknown
Due 1 December 1999
Resolved 9 December 2003
Construction/Loadline
Issued 1 November 1999
Resolved
CROP AND RENEW WASTED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999