MAURY USCG vessel records Sign in
← All vessels

GLOMAR ADRIATIC X

GLOMAR ADRIATIC X is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 11 inspections since 1999, most recently in February 2004, along with 35 deficiencies.

Records from 1999 to 2004. Most recent: inspection, 9 February 2004.

Built
1981
Last inspected
9 February 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

HO6382
505415
Flag
UNKNOWN
—
Maury page id
psix-505415

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (1999–2004)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4426 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ZION M FALGOUT Towing Vessel · MISLE 131148 · 9 February 2004 · activity 2005575

Inspection history · 11

9 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2005575
9 December 2003 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1962242
12 October 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2007992
20 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760325
5 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1753133
17 October 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713758
24 October 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1408854
24 September 2001 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1075225
17 July 2001 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1068803
30 October 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465601
1 November 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442901

Deficiency record · 35

Engineering › Compressed Air System (control)
Issued 9 December 2003 Resolved
Clean and gage or replace in kind. If gauged, provide original thickness, U1A report. Pop off valve (PRV) - provide test data or replace in kind Pressure gage - Glass lens cracked LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 4 March 2004
Lifesaving › Inflatable Liferafts
Issued 17 October 2002 Resolved
Provide liferafts meeting manufactures suggested stowage hieght requirement. Due date extended on 835 to 31DEC02 on 18NOV02 by [name withheld] via e-mail dated 18NOV02 4:33pm. LEGACY COMPONENT DESC: Carriage Requirement
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 14 January 2003
Resolution: Installed life rafts with proper stowage height of 36 meters. Work done by [name withheld].
Engineering
Issued 24 October 2001 Resolved
Provide & install exhaust lagging for #1 ships service generator bellow assembly.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758
Electrical
Issued 24 October 2001 Resolved
Remove dead-end wire in wire tray above air compressor room & pump room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001 Resolved
Properly mount junction box located in overhead wire tray in pump room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
Renew deck grating next to welding shack & inspect condition of frames
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001 Resolved
Provide two certificated lifeboatmen designated for each lifeboat with a capacity greater than 40 persons IAW 46 CFR 109.323(c)(2).
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Navigation
Issued 24 October 2001 Resolved
Repair obstruction lighting - port side.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
Repair/renew handrail courses - starboard leg.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001 Resolved
Provide cable guard for pulley on brake system for both lifeboats.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001 Resolved
Prove proper operation of emergency lighting for watermaker room & pumproom.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Construction/Loadline
Issued 24 October 2001 Resolved
Properly adjust all dogs for mud pit room doors.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001 Resolved
Properly secure all electrical wiring/cable with metal straps throughout vessel (no plastic tie wraps).
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Deck/Cargo
Issued 24 October 2001 Resolved
Provide & install plugs/caps for all storage tank drain pipes.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001 Resolved
Repair/renew wasted food storage container in port lifeboat.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Engineering
Issued 24 October 2001 Resolved
Repair leaking fuel nozzle on #2 ships service generator located on #3 cylinder, right bank.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001 Resolved
Renew pyrotechnics in all line throwing apparatus.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Lifesaving
Issued 24 October 2001 Resolved
Repair cracks in canopy on port lifeboat IWO cradle support brackets. Repairs to be completed by authorized service facility.
Condition: Unknown
Due 24 November 2001
Resolved 17 October 2002
Resolution: Cleared by MORMS Act #1713758.
Construction/Loadline
Issued 24 October 2001 Resolved
Repair wasted knife-edge combing around hospital space weather deck door.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 24 October 2001 Resolved
Provide guards for exposed bulbs in racks - various staterooms.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 24 October 2001 Resolved
Replace batteries in SARTs.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 24 October 2001 Resolved
Repair #4 agitator pump oil seal.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Engineering
Issued 24 October 2001 Resolved
Repair/replace exhaust lagging shield for #5 ships service generator exhaust piping located in Halliburton Room.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 24 October 2001 Resolved
Make permanent repairs to 8 inch, 90 degree elbow recirculation line for #1& #2 eductor pumps.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Accommodation/Occupational Safety
Issued 24 October 2001 Resolved
Repair/renew lower handrail course located on port leg.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Fire Fighting
Issued 30 October 2000 Resolved
MAKE PERMANATE REPAIRS TO FIRE MAIN IWO #1 FIRE PUMP DISCHARGE DUE TO PIN HOLE LEAK.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Construction/Loadline
Issued 30 October 2000 Resolved
REMOVE DEBREE (CEMENT) FROM BILGE AREA IWO SUCTION STRAINERS.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Construction/Loadline
Issued 30 October 2000 Resolved
MAKE PERM. REPAIRS TO BILGE SUCTION ELBOW, REMOVE TEMP PATCH.
Condition: Unknown
Due 30 November 2000
Resolved 18 November 2000
Electrical
Issued 1 November 1999 Resolved
CONDUCT THOROUGH INSPECTION OF ALL ELECTRICAL INSTALLATIONS IN SHALE SHAKERAREA UPON COMPLETION OF SAND BLASTING.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Fire Fighting
Issued 1 November 1999 Resolved
UPON COMPLETION OF YARD WORK AND PRIOR TO DEPARTURE FROM YARD ENSURE ALL FIRE FIGHTING EQUIPMENT IS ON LOCATION IN ACCORDANCE WITH FIRE CONTROL PLAN.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 1 November 1999 Resolved
RECONFIGURE FUEL OIL SUPPLY AND RETURN LINES BETWEEN DAY TANK AND CEMENT SKID UNIT. NO SECTION OF FLEXIBLE PIPING CAN EXCEED 30 INCHES.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Electrical
Issued 1 November 1999 Resolved
INSTALL APPROVED LIGHT FIXTURE FOR STERN NAVIGATION LIGHT.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Unknown
Issued 1 November 1999 Resolved
INSTALL SAFETY RELIEF VALVES OF 100 PSI OR LESS ON HOT WATER HEATERS.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
System not recorded
Issued 1 November 1999 Resolved
ADDRESS MARINE GROWTH ON LEG ESCAPE LADDERS.
Condition: Unknown
Due 1 December 1999
Resolved 9 December 2003
Construction/Loadline
Issued 1 November 1999 Resolved
CROP AND RENEW WASTED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.