Records from 2022 to 2026. Most recent: inspection, 10 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
10 August 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8460815
13 July 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8437014
8 June 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8395014
1 June 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8385394
12 May 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8376428
4 May 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8361926
29 April 2026
COC-CVE Annual · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8354987
17 March 2026
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8327677
4 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8057395
26 November 2024
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8037710
1 May 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7904870
11 April 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7893559
9 March 2024
PSC B · COC-CVE Quarterly · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7874843
27 January 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7856559
9 September 2023
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7785350
7 July 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7735763
25 May 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7696248
19 March 2023
Ballast Water Examination · COC-CVE Quarterly · Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7653172
8 March 2023
ISPS Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7647965
14 November 2022
ISPS Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7594061
14 November 2022
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7595322
17 October 2022
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7578688
18 September 2022
COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7558539
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 April 2026
Resolved
In passenger ships such units shall give an indication of any
fire and its location in any space served by the system and
shall be centralized on the navigation bridge or in the main
fire control station, which shall be so manned or equipped as
to ensure that any alarm from the system is immediately
received by a responsible member of the crew. PSCO
observed smoke detector C0775 did not activate locally or
on the bridge during testing.
74 SOLAS 01 II-2/12.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Class Survey report was submitted, rectifying defs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2026
Resolved
Fire doors in main vertical zone bulkheads and stairway
enclosures shall satisfy the following requirements. The
doors shall be self-closing and be capable of closing with an
angle of inclination of up to 3.58 opposing closure, and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s with the ship in the upright position. PSCO observed fire doors 3790 and 3759 unable to close.
74 SOLAS 97 II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Class Survey report was submitted, rectifying defs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2026
Resolved
Fire doors in main vertical zone bulkheads and stairway
enclosures shall satisfy the following requirements. The doors shall be self-closing and be capable of closing with an
angle of inclination of up to 3.58 opposing closure, and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s with the ship in the upright position. PSCO observed multiple fire doors within varying MVZs close quicker than 10 seconds.
74 SOLAS 97 II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
Resolution: Class Survey report was submitted, rectifying defs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 November 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready or immediate use. Lifeboat #2 and lifeboat #6 were found with exhaust leaks. The exhaust leaks were such that
excessive smoke was accumulating in the engine
compartment and throughout the lifeboat.
74 SOLAS 20 III/20.2 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2024
Resolved 4 January 2025
Resolution: Exhaust pipe of life boats 02 & 06 replaced in entirely. Engines now satisfactorily tested and exhaust piping found tight.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 November 2024
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Category 10 space fan room # 7-2 contained carboardboxes amongst other combustible material. In addition, the room had a “workshop” table with tools and a chair for maintaining equipment.
74 SOLAS 97 II-2/26.2.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2024
Resolved 4 January 2025
Resolution: All combustible materials and working table were removed. Now fan room 7-2 verified and found satisfactory to surveyor satisfaction.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway
enclosures, designed to re-open upon contacting an object
in its path shall re-open sufficiently to allow a clear passage of at least 0.75m but no more than 1m. PSCP observed FSD 28008, 3756A, and 87598 did not open upon activation of "crash bar."
14 SOLAS 97 11-2/30.4.2. 16 ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2024
Resolved 4 January 2025
Resolution: Now sliding FSD 28008, 3756A, and 87598 satisfactorily verified and found re-opening upon activation of 'crash" bar.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway
enclosures shall be self-closing and shall have an
approximately uniform rate of closure of no more than 40 seconds and no less than lO seconds. FD# 10757,9785,9737,8753,8770,7755, 7748, 7732A, 6751, 6761, 6784, 6783D, 5802B, & 5798A were Closing within 10 seconds.
74 S0LAS 97 II-2/30.4.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 4 January 2025
Resolution: now FSD’s 10757,9785,9737,8753,8770,7755, 7748, 7732A, 6751, 6761, 6784, 6783D, 5802B, & 5798A satisfactorily tested and found closing between 15 & 40 sec.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 November 2024
Resolved
Obstructions shall not be permitted in passenger and crew corridors forming escape routes. PSCO discovered
multiple waste receptacles in escape routes.
74 SOLAS 97 II-2/41-2.4.10 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 November 2024
Resolved 26 November 2024
Resolution: Waste recipticle were removed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 November 2024
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed high pressure water mist system nozzle obstructed by the overhead forward of steering gear in the reefer area. The nozzle was installed i such a way that it was mostly inside the overhead/ceiling.
74 SOLAS 20 II-2/14.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2024
Resolved 26 November 2024
Resolution: Nozzle was repositioned.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 November 2024
Resolved
Fire protetion systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed fire extinguisher and hydrant not readily available due to being obstructed by multiple ladders within a fie station.
74 SOLAS 20 II-2/14.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2024
Resolved 26 November 2024
Resolution: Ladders were removed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 March 2024
Resolved
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for girders, beams or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired.
While conducting the engine room portion of the exam, PSCO observed several cable transits located on watertight bulkheads in the engine room which were improperly installed with two manufacturer's types in one A boundary metal sleeve.
74 SOLAS 97 II-2/18.1.1
50 ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2024
Resolved 25 March 2024
Resolution: Received class survey attesting to satisfactory repairs
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2023
Resolved
07120-Doorways and corridors and intermediate landings included in means of escape shall be sized in the same manor as the stairways. PSCO observed escape door partially obstructed by an arcade machine bolted to the floor.
Cite 74 Solas 97 II-2/28.1.5.3 action taken 10c
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 9 September 2023
Resolved 9 September 2023
Resolution: ships crew unbolted arcade machine and moved from the escape pathway.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 19 March 2023
Resolved
Code 15113: Safety management objectives of the Company should provide for safe practices in ship operation and a safe working environment. PSCO identified multiple ongoing projects in the engine room (boiler #1 re-tubing, diesel generator #3 overhaul and a fuel split project). These multiple projects led to the storage of new and old parts, palletized equipment, large 4-5 foot toolboxes and other equipment to be stored in walkways and in escape routes leading to two escape trunks, partially blocking the walkway to them. Large equipment was ratchet strapped in place following PSCO identification, but remain in engine spaces. Additionally, to be installed equipment is stored in the I-95 passageway awaiting installation. ISM A.1.2.2.1, 16C.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2023
Resolved 29 March 2023
Resolution: Vessel submitted pictures after removing excess materials and tools from walkways to escape routes. A statement was submnitted by vessel master, see deficiency documents titled ISM Code 151132 Corrective Actions.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 March 2023
Resolved
Code 07120: In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators. Exit sign shall be marked by lighting or photoluminescent strip indicators. Exit sign located in the backstage of the theater was broken and illuminated. 74SOLAS(97)II-2/28.1.10, 10ac.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 March 2023
Resolution: Corrected prior ending the exam by replacing a lightbulb and the cover of the other sign.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 September 2022
Resolved
IT SHALL BE POSSIBLE FOR EACH DOOR TO BE OPENED AND CLOSED FROM EACH SIDE OF THE BULKHEAD BY ONE PERSON ONLY. SWTD 1.18, DECK 1, COULD NOT BE OPENED USING THE LATCH FROM EITHER SIDE. THE DOOR COULD ALSO NOT BE OPENED FROM ONE SIDE IN THE POWER CLOSE MODE, PREVENTING EGRESS FROM BUNKER STATION.
74SOLAS (2020 CONS.) CH II-2 REG 9.4.1.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 September 2022
Resolved 18 September 2022
Resolution: CREW REPLACED THE LOCKING MECHANISM, ALLOWING THE DOOR TO BE OPENED FOR EGRESS FROM BUNKER STATION