MAURY USCG vessel records
← All vessels

VI QUEST

VI QUEST is a 1999 offshore supply vessel. The Coast Guard has recorded 10 inspections since 2016, most recently in September 2022, along with 27 deficiencies and 4 casualty investigations between 2006 and 2015.

Records from 2006 to 2022. Most recent: inspection, 14 September 2022.

Built
1999
Last inspected
14 September 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 September 2022
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9222637
506871
Flag
TOGO
Maury page id
psix-506871

Documentation record

Tonnage as PSIX records it1766 - Dead Weight, Metric Ton
2649 - Displacement, Metric Ton
1124 - Convention (Subpart B), Gross Ton
337 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

14 September 2022 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7556745
22 June 2021 PSC A · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7232496
14 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6628502
16 May 2018 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6416342
20 February 2018 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6359016
17 February 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6090224
1 February 2017 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6067174
24 August 2016 Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5982272
22 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5960295
19 February 2016 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5816648

Deficiency record · 27

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 February 2019 Resolved
Replace gasket on the aft steering room watertight door and adjust all watertight doors and hatches to ensure watertight integrity. 46 CFR 131.893; 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2019
Resolution: MI attended vessel and cleared the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2019 Resolved
Replace the following non-metallic flexible hose as marked, replace with hose meeting SAE J-1942: Bow thruster engine – (3) oil hoses & (1) fuel oil hose; STBD SSDG – (1) oil gauge hoses; STBD MDE – (2) fuel oil hoses; PORT MDE – (1) oil hose; STBD R/G – (2) oil hoses; and PORT R/G – (2) oil hoses. 46 CFR 56.60-25(b); 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2019
Resolution: MI attended vessel and cleared deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2019 Resolved
Provide personnel light for engine room lifejacket. 46 CFR 133.70(b)(4); 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2019
Resolution: MI attended the vessel and cleared the deficiency.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 14 February 2019 Resolved
Provide fuel transfer procedures at fuel oil transfer pump; 33 CFR 156.120; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended vessel and cleared the deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019 Resolved
Provide emergency steering instructions at engine room steering station. 46 CFR 131.845; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended the vessel and cleared the deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 February 2019 Resolved
Calibrate bridge and rudder angle repeaters to match mechanical rudder angle indicator. 46 CFR 130.140; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended the vessel and cleared the deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 February 2019 Resolved
All five (05) dry-bulk tanks are corroded and leaking at the tank neck. Make necessary repairs to prevent leaking. 46 CFR 127.210; 50a/c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2019
Resolved 20 February 2019
Resolution: MI and Class accepted the proposed repair plans for the vessel cargo tanks to be conducted at drydock w/in 5 months..
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019 Resolved
Replace relief valves on air receivers. 46 CFR 54.15-10; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended vessel and cleared the deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019 Resolved
Make repairs to pinhole leak on #3 air receiver cut-out valve. 46 CFR 127.210; 50a/c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2019
Resolved 20 February 2019
Resolution: MI and Class attended vessel and approved repair procedure.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 14 February 2019 Resolved
Make sewage tank overboard valve operable. 33 CFR 159.17; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended vessel and cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2019 Resolved
Paint locker has insufficient fire protection, install required fire protection. In addition, paint locker is not identified on the Fire Safety Plan, amend for CG approval. 46 CFR 132.310; 46 CFR 95.15-5(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2019
Resolved 20 February 2019
Resolution: MI and Class attended the vessel and approved the changes to the fireplan, installation of required fire extinguishing system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 February 2019 Resolved
Make operational fire pump pressure gauge on bridge. 46 CFR 130.430; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 20 February 2019
Resolution: MI attended the vessel and cleared the deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 February 2019 Resolved
Make operational STBD fuel remote shut off valve. 46 CFR 56.50-60; 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2019
Resolution: MI attended the vessel and cleared the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 February 2019 Resolved
Test all smoke and heat detectors in the engine room for proper operation. 46 CFR 130.470; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: MI attended vessel and verified operation of all fire detection sensors in engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 February 2019 Resolved
Amend the Periodic Safety Test Procedures (PSTPs) to include testing of all smoke and heat detectors; submit to MSU Houma for approval. 46 CFR 130.480; 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2019
Resolved 20 February 2019
Resolution: MI attended the vessel and received updated PSTPs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2019 Resolved
Make necessary repairs to prevent oil leaks on the STBD SSDG. 46 CFR 126.430; 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2019
Resolution: MI attended vessel and verified repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2019 Resolved
Replace Type I retro-reflective material on all stowed lifejackets. 46 CFR 133.70(b)(3).
Action required: 10 - Deficiency Rectified
Resolved 14 February 2019
Resolution: Vessel corrected in presence of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 February 2019 Resolved
Replace Type II retro-reflective material on rescue boat. 46 CFR 131.855; 10c.
Action required: 10 - Deficiency Rectified
Resolved 14 February 2019
Resolution: Vessel corrected in presence of attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 February 2019 Resolved
Provide documentation that rescue boat is approved under 160.156, the rescue boat david is approved under 160.132, and the winch is approved under 160.115. 46 CFR 133.135; 46 CFR 133.160; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Vessel provided series approval documentation for rescue boat, davit, and winch to attending [name withheld] in permanent vessel documents.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 February 2018 Resolved
Several deck rails contained excessive wastage and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 15 March 2018
Resolution: All wasted rails were replaced; pictures provided via email.
Electrical › Electric Generation Source (service) › Conductor
Issued 20 February 2018 Resolved
Windings need to be free of oil, gunk and debris.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 15 March 2018
Resolution: Corrected 12MAR18; pictures were provided via email.
Fire Fighting › Fire Hydrants › Condition
Issued 20 February 2018 Resolved
Fire stations below the main deck were clogged with mud, etc., which did not allow firefighting water to flow through and must be corrected prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 February 2018
Resolution: Cleared mud from piping. All sat.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 20 February 2018 Resolved
STBD shaft tachometer is reading astern propulsion inverted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 15 March 2018
Resolution: Repaired by a technician; report was provided via email.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 1 February 2017 Resolved
Vessel failed to provide updated COFR.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 7 February 2017
Resolution: Vessel provided documentation for COFR.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 1 February 2017 Resolved
Vessel must conduct general house keeping in engine room, address oil soaked exhaust lagging and dirty generator windings.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 15 February 2017
Resolution: Vessel cleaned generator windings and general cleaning of engine room as noted by CG inspector and ABS surveyor. ABS surveyor witnessed cleaning.
Operations/Management › Drills/Instruction › Fire
Issued 19 February 2016 Resolved
Conduct fire drill prior to returning to service.
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 24 August 2016
Resolution: Witnessed satisfactory fire drill
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 19 February 2016 Resolved
Prior to returning to service conduct rescue boat drill and abandon ship drill.
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 24 August 2016
Resolution: Witnessed satisfactory abandon ship drill.

Casualty record · 4

17 May 2006Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 dead · activity 2671289
15 March 2007Routine · role: Involved in a Marine Casualty · activity 2892662
17 January 2009Routine · role: Involved in a Marine Casualty · activity 3397637
13 September 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5733708
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SOUTHERN QUEST (2006–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record