Records from 1982 to 2020. Most recent: inspection, 21 April 2020.
Inspection history · 122
21 April 2020
ISPS Exam · COC-MODU Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6941397
8 July 2019
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6745666
27 April 2018
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6405969
9 July 2017
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6202838
31 May 2017
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6170694
4 February 2017
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6082768
13 November 2016
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6039969
2 November 2016
Administrative Inspection · In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6036941
28 April 2016
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5858733
13 September 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5733708
8 August 2015
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5209424
3 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4998412
26 August 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4965955
24 June 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4898332
24 June 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4898528
3 May 2014
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4848751
7 June 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4336856
16 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4313383
26 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4127553
22 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3960773
15 January 2011
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928424
14 December 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3910524
14 October 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3869739
1 March 2010
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686295
3 February 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3681938
24 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666210
1 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3644603
12 May 2009
Examination of Repairs · In-Service Inspection · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3493652
23 March 2009
Administrative Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3441570
8 April 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3179020
26 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974479
8 May 2007
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2925113
17 April 2007
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2919797
25 March 2006
Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2610991
11 March 2005
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2309065
9 December 2004
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2249833
19 April 2004
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2042701
6 October 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1922503
5 October 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1967125
5 June 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1810377
2 June 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1807817
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760039
14 December 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718892
28 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667973
26 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666712
9 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1686171
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607022
11 March 2002
Re-Inspection · Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495616
24 February 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488773
4 September 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072322
1 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 87919
6 July 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067600
6 March 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435254
4 March 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 58431
29 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822479
8 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820141
9 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415327
16 December 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386649
6 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813340
10 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121943
12 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094050
25 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799694
12 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446734
21 December 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808721
28 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797366
11 March 1998
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400737
30 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116632
22 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782940
3 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777983
19 June 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413196
26 March 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459302
19 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099070
12 March 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 171961
16 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438516
12 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111186
26 April 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080673
18 March 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439708
21 September 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1186769
30 June 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1190843
3 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 869789
29 March 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1144524
20 December 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429978
26 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 865143
11 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176780
7 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173841
24 June 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332029
13 May 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1169466
22 April 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 857099
23 March 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358352
21 December 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849720
12 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 848325
24 March 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405380
24 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 177276
21 April 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949218
24 March 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440621
29 October 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940189
3 June 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939849
18 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922592
15 May 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931250
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917765
5 December 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220962
17 May 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1204579
24 January 1989
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 895193
19 May 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1194507
20 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310177
2 June 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314829
3 January 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009267
28 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993829
17 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301995
16 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303211
22 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326766
14 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297659
9 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988410
28 August 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987963
14 June 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297392
7 June 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984676
15 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973367
15 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974338
31 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970746
18 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970581
17 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274517
29 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274826
14 - Pollution Prevention › 146 - MARPOL Annex VI › Diesel engine relating to air pollution control
Issued 27 April 2018
Resolved
Engine Installation post Jan 1, 2000, not IAW MARPOL Annex VI. EIAPP Certificate Tech Files and Parts change out inventory. Unit has 2005 engine #4 installed with none of the above nor is it an exempted engine. Obtain certification or exemption for engine #4. MARPOL Annex VI Reg 13.2.1. 50 a, b, c. Extended to 30Aug due to Flag state interaction.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 25 May 2018
Resolution: Letter of exemption by Liberia Flag State granted.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 April 2018
Resolved
To qualify for an MMC an applicant must meet the medical and physical standards in this section. 03 members have expired medical certificates. Update certificates. 46 CFR 10.215. 40 c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 27 May 2018
Resolution: Email from operator stating all mariner's medical onboard and company policy changed about 2 year STCW medical requirements being in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 27 April 2018
Resolved
Missing Lifeboat Equipment and equipment in good condition. #1 LB has cracked oars, missing handle for e-steering. Engine compartment covers were not secured for sea. #2 LB compass card could not be seen. Air pressure levels are incorrect on data plate posted. Correct maintenance deficiencies on both LB’s. 46CFR 108.515. 50 c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 27 May 2018
Resolution: Email from operator stating all deficiencies had been cleared accompanied by 3rd party servicing report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 April 2018
Resolved
Deck line must be marked permanently in contrasting color IAW ILL Certificate. Unit is not permanently marked in contrasting color. ILL 1966. 40 c.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 27 May 2018
Resolution: Photo of new load line marks on hull.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2018
Resolved
An updated EEP must be submitted for approval for every change of location. Submit updated EEP for approval. 33CFR 146.210. Cleared on site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 27 May 2018
Resolution: Cleared on site.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 31 May 2017
Resolved
Each unit must have a chain suspension ladder or vertical ladder for each lifeboat and liferaft launching station. The two means of escape to waterline are within legs and are covered in barnacles. (Old I-A 46CFR108.151)
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 5 June 2017
Resolution: Barge Sup sent in email with attached pictures showing that ladders had been cleared/repaired.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 31 May 2017
Resolved
Each lifesaving appliance must be in good working order and ready for immediate use at all times when unit is in operation. #1 lifeboat coxswain window was cloudy and unable to see through. (Old I-1 46CFR109.301(a))
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 5 June 2017
Resolution: Barge Sup sent in email with attached pictures showing that window panel had been replaced.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 2 November 2016
Resolved
Paint locker was found in disrepair with numerous paint cans leaking thus increasing the fire load potential. Top shelf of paint locker had paint stored above discharge nozzle for CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 15 November 2016
Resolution: MODU's crew made proper changes to paint locker. OIM sent pics which showed sat results.
Documentation › Logs/Records › Oil Record Book
Issued 2 November 2016
Resolved
Entries shall be made in the oil record book (ORB) on each occasion on a tank to tank basis whenever disposal of oil residue takes place. Liberian flag rules require this entrie to be made on a weekly basis.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 2 November 2016
Resolution: Inspectors provided training to OIM and TP on proper ORB entries and Liberian flag state rules on ORB entries. Def was given a 10C.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2016
Resolved
All "A" class bulkheads and doors shall prevent the passage of smoke and flame for 60 minutes. All self closing fire doors as indicated on the fire plan shall seld close and seal. Numerous fire doors failed to close and latch satisfactorly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 19 December 2016
Resolution: OIM provided pictures of replaced door latches and provided email stating all doors have been sat fixed.
Unknown
Issued 2 November 2016
Resolved
Each unit must have on board a operating manual approved by the Coast Guard. Vessel does not have proof of CG approval of the operating manual.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 2 December 2016
Resolution: Vessel is a foreign flagged MODU and is not required to have a CG approved operating manual.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 28 April 2016
Resolved
Each unit must have a chain ladder or vertical ladder for each lifeboat and liferaft launching station. The only two means of escape to waterline are within the legs and are completely barnacled over (excessive marine growth). Either remove marine growth from ladders or find alternative means of escape. [Pre-'96 46 CFR 108.525]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 17 May 2016
Resolution: Power washed ladders inside legs to waterline. Ladders are not usable, largely free of marine growth.
Lifesaving › Inflatable Liferafts › Painter
Issued 28 April 2016
Resolved
Each inflatable liferaft that is not intended for davit launching must have a means to ensure the liferaft will float free if the unit sinks. Painter of liferaft secured to hard point on vessel rather than the weaklink. Corrected on-the-spot but also ensure the liferafts are installed correctly in the future and crew is trained.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Resolution: Painters made fast to weak link. OIM and BS educated.
Operations/Management › Drills/Instruction › Fire
Issued 28 April 2016
Resolved
The PIC shall ensure that all personnel are able to demonstrate their ability to perform the duties assigned to them. Fire team was unfamiliar with galley ansul fire system. Train fire team personnel on Ansul system, associated risks/benefits.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 17 May 2016
Resolution: Provided training to crews; submitted training log roster and training material to USCG.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 3 May 2014
Resolved
Numerous halon bottles are out of hydro. Have bottles replaced or hydro the bottles.
Action required: 705 - Other - as specified
Due 3 June 2014
Resolved 14 May 2014
Resolution: Bottles replaced by Hiller Offshore Services.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 3 May 2014
Resolved
While testing the lube oil shut-downs for #1 and #2 generators the engines alarmed but did not shut-down. Prove proper operation of the lube oil shut-downs for #1 and #2 generators
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 3 May 2014
Resolution: Adjusted pressure switches.
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 May 2014
Resolved
Found that the remote fuel valve for the fuel separator does not close. Repair and prove operation of the remote fuel valve for the fuel separator.
Action required: 705 - Other - as specified
Due 17 May 2014
Resolved 13 May 2014
Resolution: Repaired remote fuel valve for the fuel separator.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 May 2014
Resolved
When reviewing the third party fire report, found that some items for the installed fixed fire fighting systems were not carried out. Carry out the items not carried out on the fixed fire fighting systems.
Action required: 705 - Other - as specified
Due 3 June 2014
Resolved 14 May 2014
Resolution: Carried out the items not carried out on the fixed fire fighting systems.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 May 2014
Resolved
During the fire drill the galley fire shutters would not shut. Repair and prove proper operation of the galley shutters.
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 13 May 2014
Resolution: Repaired and proved proper operation of the galley shutters.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 15 January 2011
Resolved
Repair/replace air bottles in #2 lifeboat. Air bottles are leaking through the valve stems.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 20 January 2011
Resolution: Replaced air bottles in #2 lifeboat. Barge Engineer provided certificates and pictures.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 January 2011
Resolved
Replace wasted line on the starboard life-buoy.
Action required: 705 - Other - as specified
Due 22 January 2011
Resolved 20 January 2011
Resolution: Replaced wasted line on the starboard life-buoy. Barge Engineer emailed pictures.
Lifesaving › Launching Appliances › Davit
Issued 12 May 2009
Resolved
Complete repairs to lifeboat davits or provide engineers verification that the davit is in satisfactory condition for continued operation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2009
Resolution: [name withheld] attended the vessel, examined repairs and witnessed a 1.1 load test.
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2009
Resolved
Complete SEILOD Phase II Inspection within 90 days or prior to the next rig move.
Due 29 June 2009
Resolved 2 June 2009
Resolution: [name withheld] completed Phase II SEILOD at gulf copper shiyard, Galveston, TX
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 April 2007
Resolved
Prove emergency lights at both liferaft stations.
Condition: Unknown
Due 17 May 2007
Resolved 8 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 17 April 2007
Resolved
Prove sychronization of all obstruction lights.
Condition: Unknown
Due 17 May 2007
Resolved 8 May 2007
Lifesaving › Lifeboat › Hull
Issued 17 April 2007
Resolved
Prove proper repairs to damaged fiberglass on #1 port bow lifeboat, by approved lifeboat company technician.
Condition: Damaged By Earlier Event
Due 17 May 2007
Resolved 8 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 30 December 2004
Resolved
Complete phase II of SEILOD to include proof of required hull plating thickness.
Due 30 April 2005
Resolved 25 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 30 December 2004
Resolved
Repair 3" hole in deck IWO preload tank #38.
Condition: Unknown
Due 3 January 2005
Resolved 31 December 2004
Resolution: Cropped and renewed with 18 X 18 inch insert.
Construction/Loadline › Structures › Deck Plating
Issued 19 April 2004
Resolved
Mud pit room numerous holes and wastage in deck, temp repair and renew within thirty days.
Condition: Improper/Lack of Maintenance
Due 20 May 2004
Resolved 9 May 2004
Resolution: fax by OIM
Fire Fighting › Fire Main › Valves
Issued 19 April 2004
Resolved
relief valves replace or rebuild. fire main relief valves.
Due 20 May 2004
Resolved 9 May 2004
Resolution: OIM sent fax to office
Lifesaving › Thermal Protective Aids › General
Issued 19 April 2004
Resolved
Provide 10% on vessel. 6 per life boat.
Due 5 October 2004
Resolved 5 May 2004
Resolution: OIM fax
Fire Fighting › Fire Main › Condition
Issued 19 April 2004
Resolved
Repair small pin holes in fire main piping
Due 5 May 2004
Resolved 5 May 2004
Resolution: OIM fax
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 19 April 2004
Resolved
Remove refueling hose from sack room and provide a portable 5 gallon container for refueling. 49/176.78 h.3
Due 27 April 2004
Resolved 27 April 2004
Resolution: fax and phone call by OIM.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 11 March 2004
Resolved
Flextible exhuast pipe cracked on welded seam. Replaced with hard pipe.
Condition: Placed in Improper Service
Due 11 March 2005
Resolved 11 March 2005
Fire Fighting › Fire Main
Issued 11 March 2002
Resolved
MAKE PERMANENT REPAIRS TO FIREMAIN PIPING IN #6 PRELOAD TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR
Due 11 April 2002
Resolved 13 March 2002
Deck/Cargo › Holds/Tanks
Issued 11 March 2002
Resolved
MAKE DRILLWATER/PRELOAD TANKS 1A/1B AVAILABLE FOR INTERNAL INSPECTION. ALONG WITH VALVES 1A, 5, 6, 12, 26, AND 27
Due 11 April 2002
Resolved 16 April 2002
Deck/Cargo › Holds/Tanks
Issued 11 March 2002
Resolved
PROVIDE GAUGING RPT AND ORIGINAL SCANTLING OF OVERHEAD ANGLES IN DRILLWATER TANKS 13&14
Due 11 April 2002
Resolved 16 April 2002
Resolution: WITNESS GAUGING. Final report submitted.
Engineering › Pressure Vessel
Issued 11 March 2002
Resolved
MAKE ALL PRESSURE VESSELS AVAILABLE FOR INTERNAL INSPECTION OR PROVIDE GAUGING RPT AND ORIGINAL SCANTLINGS; OR PROVIDE PROOF OF COMPLETION LEGACY COMPONENT DESC: Shell Plate
Due 30 April 2002
Resolved 4 June 2003
Construction/Loadline
Issued 6 March 2001
Resolved
REPLACE SUCTION VALVE ON PORT SIDE BILGE PUMP.
Condition: Unknown
Due 4 April 2001
Resolved 18 July 2001
Construction/Loadline
Issued 6 March 2001
Resolved
PROVE ALL BILGE SUCTIONS TO THE RATED CAPACITY OF EACH BILGE PUMP AS STIPULATED BY MANUFACTURER.
Condition: Unknown
Due 30 August 2001
Resolved 6 March 2001
Construction/Loadline
Issued 6 March 2001
Resolved
REPAIR OR REPLACE VALVE IN STARBOARD BILGE ROOM SUMP.
Condition: Unknown
Due 4 April 2001
Resolved 18 July 2001
Construction/Loadline
Issued 9 March 2000
Resolved
RENEW FLEX COUPLING ON PROT SEA CHEST PUMP.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Deck/Cargo
Issued 9 March 2000
Resolved
POP TEST AND LOG SETTINGS ON SAFETY RELIEF VALVES FOR ALL P-TANKS (6) AND ALL AIR RECEIVERS (3).
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 9 March 2000
Resolved
CROP AND RENEW WASTED ROTTMER RELEASE GEAR PIPING ON LIFEBOAT # 2.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 9 March 2000
Resolved
CROP AND RENEW HAND RAILS WHERE WASTED AT PROT AFT LEG, AT FIRE MONITOR STATION FOR HELI DECK,AND LADDER TO DRILL FLOOR.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 16 December 1999
Resolved
MAKE THE FOLLOWING AVAILABLE FOR INTERNAL EXAM: PRE-LOAD TANKS #1A AND 1B, AND VOID #2.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Engineering
Issued 16 December 1999
Resolved
INSTALL 30X30 MESH FLAME SCREENS ON ALL FUEL OIL TANK VENTS.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Construction/Loadline
Issued 16 December 1999
Resolved
CROP AND RENEW VENT RISER AT PRE-LOAD TANKS #36 AND 37.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Construction/Loadline
Issued 16 December 1999
Resolved
CROP AND RENEW LADDER, MAIN ACCESS FOR PRE-LOAD TANK # 36.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Construction/Loadline
Issued 16 December 1999
Resolved
CONDUCT PHASE II OF HULL EXAM, SUBMIT COPY OF DIVER'S REPORT AND VIDEO TO THE [name withheld].
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Construction/Loadline
Issued 16 December 1999
Resolved
CROP AND RENEW WASTED AND HOLED DECK SUPPORT AT PORT LIFEBOAT.
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 12 March 1999
Resolved
Ensure that original of current CG approved stability letter (approved 11MAY95) and copy of current CG approved operation manual (with appropriatecurrent revision(s)) are onboard.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 12 March 1999
Resolved
Crop and renew wasted piping on firemain riser at hose station no. 6.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 March 1999
Resolved
Provide better system of indicating loss-of-ventilation alarm in mud pit room. System must indicate actual loss of ventilation flow from mud pump room into pit room and from sack room into pit room via vent flow indicatoror relative presssure differential sensing device.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 12 March 1999
Resolved
Repair or replace all deteriorated/damaged ringbuoys; replace expired or expended smoke signals; outfit ringbuoys in accordance with MODU's most recent CG approved Firefighting/Lifesaving Plan (28MAR97) and in accordancewith 1995 (or earlier edition) requirements of 46 CFR 108.515.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 March 1999
Resolved
Investigate and repair lifeboat no. 1 davit winch internal brake releasing problem. Prove proper operation of same.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 11 March 1998
Resolved
PROVE PROPER OPERATION OF ALL TOTAL RIG SHUT DOWN LOCATION.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 11 March 1998
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELLS IN THE SHELL SHAKER RM.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 11 March 1998
Resolved
REMOVE DEAD ENDED WIRE ON EMEGY RM HOUSE, PORT SIDE.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 11 March 1998
Resolved
REPAIR OR REPLACE EMEGRNY GEN RM VENT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 11 March 1998
Resolved
REPAIR OR REPLACE EMEGENCY LT IN MACH RM.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 11 March 1998
Resolved
PROPER SEAL WIRING IN JUNCTION BOXS IN MUD PIT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Construction/Loadline
Issued 11 March 1998
Resolved
MAKE ALL WTD'S CLOSE PROPERLY.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Construction/Loadline
Issued 19 June 1997
Resolved
COMPLETE UNDERWATER HULL EXAM OF SPUD CANS AND NDT OF CRITICAL CONNECTIONS.COMPLETE REPAIRS AS DISCUSSED WITH ABS SURVEYOR. PROVIDE COPY OF FINAL REPORT OF THIS EXAM AND REPAIRS TO [name withheld].
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Lifesaving
Issued 26 March 1997
Resolved
MAKE REPAIRS, ALTERATIONS AND CHANGES IN POLICY TO COMPLY WITH REVISIONS TO46 CFR 107-109. REFERENCE ISSUED POLICY TO OIM ON 11MAR97 AND FEDERAL REGISTER, VOLUME 61, NO. 98, DATED 20MAY96.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Unknown
Issued 26 March 1997
Resolved
CONDUCT INTERNAL EXAMINATION AND TEST SAFETY RELIEF VALVE OF DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Lifesaving
Issued 26 March 1997
Resolved
CONDUCT WIEGHT TEST OF LIFERAFT DAVITS.
Condition: Unknown
Due 10 April 1997
Resolved 31 March 1997
Electrical
Issued 26 March 1997
Resolved
MAKE MUD PIT DOORS SELF-CLOSING AND GAS TIGHT; REPAIR HOLES IN BULKHEAD BETWEEN PITS AND PUMP ROOM; INSTALL STUFFING TUBES FOR WIRE PENETRATIONS ASNECESSARY.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Documentation
Issued 26 March 1997
Resolved
RESUBMIT HAZARDOUS AREA LAYOUT PLAN TO THE COGNIZANT OCMI WITH NOTED CHANGES FOR APPROVAL. (REF. MORMS LETTER OCS-70147)
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Electrical
Issued 26 March 1997
Resolved
CONDUCT EMERGENCY BATTERY LOAD TEST AND LOG.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Fire Fighting
Issued 26 March 1997
Resolved
CALIBRATE O2 / LEL METERS.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Lifesaving
Issued 26 March 1997
Resolved
INSTALL CAGES AROUND SERVICE LADDERS ON LEG JACKING HOUSES THAT ARE 20 FOOTOR HIGHER.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Lifesaving
Issued 26 March 1997
Resolved
SUBMIT SERVICING REPORT OF #3 LIFERAFT ANNUAL INSPECTION.
Condition: Unknown
Due 26 April 1997
Resolved 31 March 1997
Electrical
Issued 26 March 1997
Resolved
VERIFY THAT LIFEBOAT EMBARKATION STATIONS ARE ADEQUATELY LIT WITH EMERGENCYLIGHTING AND THAT THE EMERGENCY LIGHTING IS PROPERLY MARKED.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Lifesaving
Issued 26 March 1997
Resolved
SUBMIT 3rd PARTY REPORT OF LIFEBOAT INSPECTIONS AND WIEGHT TEST.
Condition: Unknown
Due 3 April 1997
Resolved 31 March 1997
Construction/Loadline
Issued 26 March 1997
Resolved
CONDUCT NDT OF LEG TO CAN CRITICAL CONNECTIONS AND CONDUCT UNDERWATER INPECTION OF SPUD CANS.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Fire Fighting
Issued 16 December 1996
Resolved
RENEW OR REMOVE ALL THREE FIRE MONITORS ON HELO DECK. RENEW THE WASTED FIREMAIN PIPING THAT SUPPLIES FIRE FIGHTING WATER TO THE HELO DECK.
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Documentation
Issued 16 December 1996
Resolved
RESUBMIT FIRE CONTROL AND SAFETY PLAN TO THE COGNZANT OCMI WITH NOTED CHANGES FOR APPROVAL.
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Lifesaving
Issued 18 March 1996
Resolved
Conduct weight tests ojn both lifeboat/davits and davit for davit launched liferafts at 100 percent maximum load (58 men X 165 lbs for each lifeboat; 25 men X 165 lbs plus 400 lbs for liferaft davit).
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
Repair or replace the following of port lifeboat: 1) free-up stiff rudder movement. 2) replace two crimped air hoses for emergency breathing air cylinders.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Documentation
Issued 18 March 1996
Resolved
Standardized all posted fire control/lifesaving plans on rig. Some were appoved 1983, others 1992. Posted plans must be latest revision and must approved by CG.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Electrical
Issued 18 March 1996
Resolved
Repair and prove proper operation of low lube oil pressure shutdown on no. 1 generator.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
Replace missing self-activating smoke signal on stbd side ring buoy. Install reflective tape on all ring bouys.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
Repair or replace following on stbd lifeboat: 1) replace signalling mirrors, 2) replace one crimped hose on emergency breathing air cylinders, and 3) free-up binding rudder movement.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Documentation
Issued 18 March 1996
Resolved
Provide onboard a Coast Guard or ABS approved construction portfolio.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 30 June 1995
Resolved
MAKE LOWER HULL (PHASE II) AVAILABLE FOR INSPECTION PRIOR TO NEXT RIG MOVE.THIS REQUIREMENT INITIALLY ISSUED BY MORMS. NO FURTHER EXTENSIONS WILL BE GRANTED.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Construction/Loadline
Issued 20 December 1994
Resolved
CONDUCT REPAIRS TO #41 PRELOAD TANK SIDE SHELL PLATE AND SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Construction/Loadline
Issued 20 December 1994
Resolved
MAKE LOWER HULL (PHASE II) AVAILABLE FOR INSPECTION PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Documentation
Issued 26 October 1994
Resolved
SUBMIT INFORMATION/CALCULATIONS AND OPERATING MANUAL TO THE MARINE SAFETY CENTER FOR REVIEW AND APPROVAL. SUBMIT COPIES OF CORRESPONDENCE TO MSO PORTARTHUR.
Condition: Unknown
Due 7 November 1994
Resolved 19 May 1995
Deck/Cargo
Issued 23 March 1994
Resolved
PROVIDE "UL" LABEL FOR RIG FORKLIFT. 46 CFR 91.25-10
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Lifesaving
Issued 23 March 1994
Resolved
RENEW EXPIRED RED HAND FLARES (7 EA) IN PORT LIFE BOAT. 46CFR 91.25-15
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 23 March 1994
Resolved
PROVIDE PROPER H/W HEATER PRESSURE/TEMPERATURE RELIEF VALVES WITH <100PSI/<210 DEG. F, UNITS.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Lifesaving
Issued 23 March 1994
Resolved
REPLACE FISHING KITS IN BOTH LIFE BOATS. 46CFR 91.25-15
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 24 March 1993
Resolved
RENEW L/B #1 & #2 FALLS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 24 March 1993
Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR #4 DAVIT LAUNCHED LIFERAFT AND #3 & #5 THROW OVER LIFE RAFTS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 24 March 1993
Resolved
REPLACE MISSING SWITCHES ON DRILL FLOOR ELECTRICAL PANEL EL-6(4 EA.) AND RESTORE PANEL TO FACTORY SPECS.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 24 March 1993
Resolved
SERVICE FIRE EXTINGUISHERS AS INDICATED ON PENDANT LINE SERVICING REPORT.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993
Resolved
MAKE ALL ELECTRICAL INSTALLATIONS FOR "GUST I CENTERFUGE" IN ACCORDANCE WITH CLASS I, DIV I REQUIREMENTS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Accommodation/Occupational Safety
Issued 24 March 1993
Resolved
PROVIDE DOCUMENTATION TO PROVE WINDOW SHUTTERS INSTALLED ON WINDOWS FACING DRILL FLOOR ARE INSTALLED PROPERLY (I.E. AUTOMATIC RELEASE ACTIVATION)
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 24 March 1993
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Lifesaving
Issued 24 March 1993
Resolved
INSTALL PROPERLY RATED SHACKLE FOR DAVIT LAUNCHED LIFERAFT (I.E. 3 TON 5/8"SHACKLE)
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 24 March 1993
Resolved
REINSTALL MISSING AIR BOTTLES FOR #1 & #2 LIFEBOATS._x001C_
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 24 March 1993
Resolved
INSTALL WEAK LINK FOR #5 THROW OVER LIFERAFT.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 24 March 1993
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Engineering
Issued 24 March 1993
Resolved
RENEW CONTAINMENT UNDER DF VENTS 20,22,24 AND DF VENTS 29,21,31._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 24 March 1993
Resolved
PROVIDE ACCURATE MEANS OF INDICATING ENGINE SPEED (RPM) AND RETEST ENGINE OVERSPEED SHUTDOWNS ON ALL EMD'S AND EMERGENCY GENERATOR. (MUST SHUTDOWN AT NO MORE THAN 15% OVER RATED SPEED).
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Construction/Loadline
Issued 24 March 1993
Resolved
PROVIDE REPORT OF ULTRASOUND GAUGINGS ON MUDPIT ROOM FWD BULKHEAD BEHIND MUD TROUGH. TAKE GAUGINGS AT 1' LEVEL ABOVE DECK IN AREAS OF WORST WASTAGE(APPROX. 20' X 2').
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 24 March 1993
Resolved
INSTALL ELECTRICAL CABLE STUFFING TUBES MUD PIT ROOM OVER PIT/PUMP ROOM DOOR AND REMOVE AND/OR PROPERLY SECURE EXCESS 3RD PARTY ELECTRICAL CABLE INOVERHEAD.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Accommodation/Occupational Safety
Issued 24 March 1993
Resolved
REPLACE RELIEF VALVE ON SANITARY WATER PRESSURE TANK AND INSTALL SCHRAEDER(NEEDLE TYPE) AIR VALVE AT AIR CHARGE CONNECTION. (RELIEF VALVE MUST BE <100 PSI
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Accommodation/Occupational Safety
Issued 24 March 1993
Resolved
INSTALL GASKET MATERIAL ON MUD PIT ROOM SELF-CLOSING DOORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 24 March 1993
Resolved
REMOVE 3RD PARTY NON EXPLOSION-PROOF PRESSURE SWITCH BEHIND BOP CHOKE PANELON DRILL FLOOR.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 24 March 1993
Resolved
REMOVE ALL "SO" TYPE CABLE COMING FROM PETROBRAS TRAILER TO SHALE SHAKER, MUDPITS, AND DRILL FLOOR. NEW CABLE MUST BE IN CABLE TRAYS AND ARMORED CABLE IN CLASS I DIV.I LOCATIONS. MINIMUM OF "MI" TYPE IN ALL OTHER LOCATIONS.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 15 May 1990
Resolved
IN ACCORDANCE WITH NFPA 496 PROVIDE LOSS OF PURGE ALARM FOR GAS DETECTOR PANEL LOCATED IN DOG HOUSE ON RIG FLOOR.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
REPAIR VISUAL LOSS OF PURGE ALARM TO TOTCO PUMP STROKE COUNTER RIG FLOOR.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
PROVIDE LOSS OF PURGE ALARM TO THE PUMP SPM 1,2,3, TACHOMETER PANEL LOCATEDBY DRILLERS CONSOLE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
PROVIDE NEGATIVE PRESSURE FOR MUD PITS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Lifesaving
Issued 15 May 1990
Resolved
REPLACE SIDE AND REAR WINDOWS ON COXSWAIN FLAT BOTH #1, #2 LIFEBOATS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
RE-MOUNT ELECTRICAL JUCTION BOX AFT OF QUARTERS EXTERIOR BY FIRE EXTINGUISHER #24.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Construction/Loadline
Issued 15 May 1990
Resolved
REPLACE TWO MISSING DOGS ON DRY BULK ACCESS WATER TIGHT HATCH ON MAIN DECK AFT OF QUARTERS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Lifesaving
Issued 15 May 1990
Resolved
RE-ATTACH RUB RAIL TO #1 LIFE BOAT.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
PROVIDE ADDITIONAL GENERAL ALARM FOR EXTREME PORT AFT AREA OF RIG.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Documentation
Issued 15 May 1990
Resolved
PROVIDE ON BOARD AN APPROVED OPERATING MANUAL MEETING THE REQUIREMENTS OF 46CFR 109.121, OR SUBMIT DOCUMENTATION MANUAL HAS BEEN SUBMITTED TO USCG FOR APPROVAL
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Construction/Loadline
Issued 15 May 1990
Resolved
PROVIDE FLUSH MOUNTED FLAME SCREENS FOR FUEL TANK VENTS DF-20, DF-24, DF-28AND BOTH DAY TANK VENTS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Construction/Loadline
Issued 5 December 1989
Resolved
COMPLETE UNDERWATER EXAMINATION IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Fire Fighting
Issued 17 May 1989
Resolved
INSTALL RUBBER MOUNTS ON BOTH FIRE PUMPS OR HARD PIPE FIRE MAIN.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
REPLACE SADDLE REDUCER ON OVERHEAD FIRE MAIN IN STARBOARD BILGE PUMP ROOM FOR AFT FIRE PUMP AND CONDUCT HYDROSTATIC TEST OF REPAIR.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
CONDUCT OPERATIONAL TEST OF BOTH SAFETY RELIEF VALVES FOR FIRE PUMPS.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989
Resolved
RECHARGE FIXED HALON BOTTLE FOR SCR ROOM. UNTIL SYSTEM IS RECHARGED MAINTAIN TWO ADDITIONAL B-II PORTABLE FIRE EXTINGUISHERS IN SCR ROOM.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 24 January 1989
Resolved
PROVIDE ON BOARD TWO OPERATIONAL OXYGEN METERS.
Condition: Unknown
Due 24 January 1989
Resolved 24 January 1989
Lifesaving
Issued 2 June 1987
Resolved
FILL LIFEBOAT AIR CYLINDERS TO 1800-2000 PSI, LIFEBOAT #1
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Engineering
Issued 2 June 1987
Resolved
REPAIR WASTAGE TO POLLUTION CONTAINMENT BINS PORT AND STBD SIDE.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987
Resolved
PROVIDE STUFFING TURNS FOR BULKHEAD PENETRATIONS INTO MUD PIT ROOM.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Construction/Loadline
Issued 2 June 1987
Resolved
MAKE PERMANENT REPAIR TO WASTED FRAMING ON GAS TIGHT DOOR TO MUD PIT ROOM
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Fire Fighting
Issued 2 June 1987
Resolved
REFILL AND CONDUCT HYDRO TEST OF SELF CONTAINED BREATHING APPARATUS CYLINDER
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Accommodation/Occupational Safety
Issued 16 June 1986
Resolved
MAKE OPERABLE THE MARINE SANITATION DEVICE. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Documentation
Issued 16 June 1986
Resolved
PROVIDE ON BOARD CURRENT CERTIFICATE OF DOCUMENTATION. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Fire Fighting
Issued 16 June 1986
Resolved
PROVIDE FULLY CHARGED AIR TANKS AND SPARES FOR THE FIREMEN'S OUTFITS. COMPLIANCED DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Electrical
Issued 16 June 1986
Resolved
PROVE PROPER OPERATION OF THE REMOTE VENTILATION, FUEL OIL TRANSFER AND DIRTY OIL PUMP SHUTDOWNS. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Electrical
Issued 16 June 1986
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR HIGH WATER TEMP AND LOW LUBE OIL PRESSURE ALARMS. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Accommodation/Occupational Safety
Issued 16 June 1986
Resolved
PROVIDE RELIEF VALVES SET AT NOT MORE THAN 100 PSI FOR THE HOT WATER HEATERS AND THE SANITORY WATER PRESSURE TANK. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Documentation
Issued 16 June 1986
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO. COMPLIANCE DATE IS 16JUL86.
Condition: Unknown
Due 16 June 1986
Resolved 16 June 1986
Deck/Cargo
Issued 14 June 1985
Resolved
MAKE AVAILABLE FOR INSPECTION TO AN ATTENDING USCG INSPECTOR THE FOLLOWING ITEMS: (A) #8 AND #25 PRELOAD DUMP VALVES (B) THE (3) THREE MUD PIT DUMP
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Construction/Loadline
Issued 14 June 1985
Resolved
PLACE AN 18 INCH BY 18 INCH RADIUS INSERT IN DAMAGED SHELL PLATE LOCATED APPROXIMATELY 3 FEET DOWN FROM DECK IN NUMBER (20) TWENTY PRELOAD TANK.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Unknown
Issued 14 June 1985
Resolved
PROVIDE ABOARD THE RIG AN FMC CERTIFICATE (CERTIFICATE OF FINANCIAL RESPON-SIBILITY) WITH A VALID EXPIRATION DATE.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Deck/Cargo
Issued 7 June 1985
Resolved
PROVIDE ON THE FUEL HOSE THE RATED MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Deck/Cargo
Issued 7 June 1985
Resolved
PROVIDE MARKING "OIL SERVICE" ON THE FUEL OIL TRANSFER HOSE.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Unknown
Issued 7 June 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 87, O.N. DN648969. THE COMPLIANCE DATE FOR THE MODU IS 07 JULY 1985.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Deck/Cargo
Issued 7 June 1985
Resolved
PROVIDE A 'D' OR 'DS' DESIGNATION ON THE FORKLIFT (46CFR108.613)
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Deck/Cargo
Issued 7 June 1985
Resolved
PROVIDE A UL OR FM APPROVAL STAMP ON THE FORKLIFT.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Deck/Cargo
Issued 15 June 1984
Resolved
NO. 1 LIFEBOAT APPEARS TO RUB ON OVERBOARD DISCHARGE TROUGH WHEN LOWERED. CHECK FOR ANY DAMAGE TO PORT SIDE AT TIME OF REINSPECTION.
Condition: Unknown
Due 15 June 1984
Resolved 15 June 1984
Unknown
Issued 15 June 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE MODU PENROD 87, DN648969 AND IS TO BE COMPLIED WITH BY 15JUN85.
Condition: Unknown
Due 15 June 1984
Resolved 15 June 1984
Fire Fighting
Issued 17 June 1983
Resolved
PROVIDE SUITABLE GENERAL ALARM BELLS FORWARD OF THE QUARTERS ON MAIN DECK AND IN THE MUD PITS COMPARTMENT.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Electrical
Issued 17 June 1983
Resolved
SUBMIT VESSEL'S HAZARDOUS LOCATION PLAN FOR REVIEW AND APPROVAL TO [name withheld], LOUISIANA AS PER 46 CFR 111.05-5.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Unknown
Issued 17 June 1983
Resolved
PROVIDE SUITABLE OIL TRANSFER PROCEDURES AS PER 33 CFR 155.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Lifesaving
Issued 17 June 1983
Resolved
PROVIDE TWENTY-THREE (23) ADDITIONAL QUARTS OF WATER FOR THE PORT LIFEBOAT AS PER 46 CFR 108.503.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Navigation
Issued 17 June 1983
Resolved
PROVIDE THREE (3) BALLS AND ONE (1) DIAMOND DAY SHAPE AS PER 1972 COLREGS AND ANNEX I.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Navigation
Issued 17 June 1983
Resolved
PROVIDE A SHIP'S BELL FOR THE VESSEL AS PER 1972 COLREGS AND ANNEX III.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Fire Fighting
Issued 17 June 1983
Resolved
SUBMIT VESSEL'S FIRE CONTROL/LIFESAVING PLAN FOR REVIEW AND APPROVAL TO [name withheld], LOUISIANA AS PER 46 CFR 107.305.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Documentation
Issued 17 June 1983
Resolved
PROVIDE VALID LOADLINE CERTIFICATE AS PER 46 CFR 107.231
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Construction/Loadline
Issued 17 June 1983
Resolved
PROVIDE SUITABLE CLOSURES FOR OPENINGS ON EMERGENCY GENERATOR ROOM AS PER 46 CFR 108.181(D).
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Unknown
Issued 17 June 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 87, DN648969
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Fire Fighting
Issued 17 June 1983
Resolved
PROVIDE LOW VELOCITY FOG APPLICATORS FOR ALL HOSE STATIONS PROTECTING MAIN GENERATOR ROOM AS PER 46 CFR 108.425.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Electrical
Issued 17 June 1983
Resolved
PROVIDE AIR PURGE ALARM FOR GAS DETECTOR CABINET ON DRILL FLOOR AS PER N.F.P.A. 496.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Electrical
Issued 17 June 1983
Resolved
REMOVE ALL DEAD END CABLES FROM DRILL FLOOR DOG HOUSE AS PER 46 CFR 111.80-5.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Electrical
Issued 17 June 1983
Resolved
REPAIR OR REPLACE FORWARD LIMIT SWITCH ON STARBOARD LIFEBOAT AS PER 46 CFR 111.80-55.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Lifesaving
Issued 17 June 1983
Resolved
PROVIDE NINETEEN (19) ADDITIONAL QUARTS OF WATER FOR THE STARBOARD LIFEBOATAS PER 46 CFR 108.503.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Lifesaving
Issued 17 June 1983
Resolved
PROVIDE APPROPRIATE 500 FEET AUXILIARY LINE FOR LINE-THROWING GUN AS PER 46 CFR 108.517.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983
Lifesaving
Issued 17 June 1983
Resolved
PROVIDE THREE (3) ADDITIONAL CARTRIDGES FOR LINE-THROWING GUN AS PER 46 CFR 108.517.
Condition: Unknown
Due 17 June 1983
Resolved 17 June 1983