MAURY USCG vessel records
← All vessels

SIM 1

SIM 1 is a 2000 tank barge. The Coast Guard has recorded 51 inspections since 1999, most recently in September 2024, along with 43 deficiencies and 3 casualty investigations between 2005 and 2013.

Records from 1999 to 2024. Most recent: inspection, 18 September 2024.

Built
2000
Last inspected
18 September 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 18 September 2024
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1999–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

506921
Flag
UNITED STATES
Maury page id
psix-506921

Documentation record

Registered dimensions (L × B × D)260.0 ft × 52.0 ft × 14.0 ft
Registered tonnagegross 1,589 / net 1,589
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPCS PHOSPHATE COMPANY INC · AMELIA, LA, UNITED STATES · built 2000
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1589 - Simplified, Gross Ton
1589 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 51

18 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8004905
20 July 2023 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7747234
7 September 2022 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7537258
24 September 2021 Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7319711
20 September 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7316344
9 November 2020 Load Line/Change of Employment
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7092523
10 July 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7002907
6 December 2019 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6868553
4 December 2019 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6866940
9 October 2019 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6821646
24 July 2018 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6472865
13 July 2017 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6191706
12 September 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5998936
1 September 2016 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5966002
20 July 2015 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5190045
12 June 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5150718
20 June 2014 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4894011
16 October 2013 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4736777
25 July 2013 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4664048
17 July 2013 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4656296
27 August 2012 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4431625
1 August 2012 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4398282
11 August 2011 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4096197
23 June 2010 MTSA Verification · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3775374
19 February 2010 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3682567
11 June 2009 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3500904
28 January 2009 Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3401450
1 July 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3253649
26 March 2008 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3179151
12 July 2007 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3013484
22 May 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2945294
11 May 2006 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2658048
26 September 2005 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2501730
20 September 2005 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2498163
14 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2426489
18 April 2005 COI Inspection · MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2337026
28 February 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2300463
24 November 2004 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2249549
10 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238905
30 April 2004 Deficiency Check · Administrative Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2056257
29 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997387
10 November 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1945002
22 May 2003 Internal Structural Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1821314
30 November 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1712504
11 September 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439259
21 June 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1065394
22 May 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1067314
4 May 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1067311
22 May 2000 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456836
20 April 2000 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454795
17 December 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 812394

Deficiency record · 43

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2018 Resolved
Void #2 STBD Side goose neck vent wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 16 August 2018
Resolution: Replaced with new, SAT
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 24 July 2018 Resolved
Replaced wasted electrical junction boxes on bow
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: All bow conduit and junction boxes replaced, all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2018 Resolved
Generator exhaust stack flap not operating properly. Flap will not cover exhaust stack.
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 16 August 2018
Resolution: Flap replaced,all SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2018 Resolved
Generator gen set cable block missing, causing the gen set to have an open hole.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: Installed new hole block, all SAT.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 13 July 2017 Resolved
#1 and #2 sight glasses on cargo tanks for ullage/transfer is blocked and preventing sight of gauging to be used as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 22 August 2017
Resolution: M/I verified that the sight glasses were cleaned.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 July 2017 Resolved
2" fractured weld on longitudinal starboard aft frame on aft bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 22 August 2017
Resolution: M/I verified that the weld was cropped and renewed.
Deck/Cargo › Cargo Heating › General
Issued 1 September 2016 Resolved
Low process flow limit (Differential)rep needs to prove proper operation of TFH. Prior to onload of carge
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2016
Resolved 12 September 2016
Resolution: Replaced pressure switch for low flow limit.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 1 September 2016 Resolved
Cargo tank valves missing valve indicators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 12 September 2016
Resolution: Installed new valve indicators on port and STBD discharge valves.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 July 2015 Resolved
The vessel certificate of Documentation is expired.
Condition: Invalid
Due 21 August 2015
Resolved 5 August 2015
Resolution: Proof of vessel documentation has been received from the NVDC. The vessel document has not been received yet but is en-route.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 July 2015 Resolved
Provide updated piping diagram indicating current pipeline and pump confirguation onboard. Two cargo pumps were removed from the barge, they were properly closed off from the piping system but the piping diagram onboard was not corrected.
Due 21 August 2015
Resolved 24 July 2015
Fire Fighting › Ventilation Systems › Fans
Issued 20 July 2015 Resolved
Replace gasket material on vent closure to thermal fluid heater space.
Due 21 August 2015
Resolved 24 July 2015
Engineering › Fuel Oil Service System › Burner
Issued 20 July 2015 Resolved
Calibrate the TRH burner ingition sequence switch.
Due 21 August 2015
Resolved 24 July 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 July 2015 Resolved
INsulate all exposed cargo piping in way of #1 and #2 cargo pump and transfer area.
Due 21 August 2015
Resolved 24 July 2015
Deck/Cargo › Cargo Heating › General
Issued 20 July 2015 Resolved
Remove all debris from inside the Thermal Fliud Heater. Excessive rust scaling was noted upon internal inspection of the fire box.
Due 21 August 2015
Resolved 24 July 2015
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2015 Resolved
Repair or replace lighting fixtures in the generator space.
Due 21 August 2015
Resolved 24 July 2015
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 29 July 2014 Resolved
Renew main breaker IWO generator (will not trip) and perform operational test upon completion.
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Construction/Loadline › Hull › Weld
Issued 29 July 2014 Resolved
Re-weld pickups IWO fwd coaming
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 29 July 2014 Resolved
Bolt down spare cargo pump motor (or remove)
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Electrical › Electric Supply System (service) › Transformer
Issued 29 July 2014 Resolved
Renew transformer IWO main breaker panel
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 29 July 2014 Resolved
Renew/repair ventilation fans IWO heater space
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 29 July 2014 Resolved
Provide guard for emergency stop IWO generator
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 July 2014 Resolved
Paint STBD fwd draft marks
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 22 August 2014
Deck/Cargo › Cargo Heating › General
Issued 1 August 2012 Resolved
Sight glass for Thermal Fluid Heater (TFH) was not installed properly (cut to short at top).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2012
Resolved 27 August 2012
Resolution: Attending inspectors verified new installation of sight glass for TFH.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 August 2012 Resolved
Electrical outlet located in Tankerman Shack was not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2012
Resolved 27 August 2012
Resolution: Attending inspectors verified corrections made to electrical outlet located in Tankerman''s shack.
Deck/Cargo › Cargo Stowage › General
Issued 1 August 2012 Resolved
Cargo tank sight glasses were clouded due to cargo (molten sulfur).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2012
Resolved 27 August 2012
Resolution: Attending inspectors verified that all cargo tank sight glasses were transparent.
Deck/Cargo › Cargo Heating › General
Issued 1 August 2012 Resolved
Exhaust stack venting inside of Thermal Fluid Heater (TFH)/Generator room (open plug located inboard side of TFH exhaust stack)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2012
Resolved 27 August 2012
Resolution: Attending insepctors verified repairs made to TFH exhaust stack located in generator/TFH room.
Deck/Cargo › Cargo Heating › General
Issued 1 August 2012 Resolved
Testing instructions for Thermal Fluid Heater (TFH) were not for unit installed on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2012
Resolved 13 May 2013
Deck/Cargo › Cargo Heating › General
Issued 11 August 2011 Resolved
Properly mount Fuel solenoid for Boiler control system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 16 August 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2009 Resolved
Install missing plug in navigation light junction box on the port side nav light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 12 June 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 11 June 2009 Resolved
Repair/replace ullage inspection box lid, lid is frozen and unusable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 15 June 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 June 2009 Resolved
Repair/replace phase sequence transfer switch handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 19 June 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 March 2009 Resolved
Provide a report of ultrasonic testing shots in a grid with 24 inch spacing on forward bulkhead, with belts on same plane of holed area from bottom of cargo tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 27 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 March 2009 Resolved
Once UT report is completed provide a written repair proposal addressing all areas of plate that are less than 25% wastage from original. Report is to include welding details, edge preparation, and final testing of cargo tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 27 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 March 2009 Resolved
UT reading are to be taken on all cargo tanks to determine the extent of wastage on the other tanks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 27 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 March 2009 Resolved
Prior to the commencement of work all welders are to be certified by the Coast Guard, ABS, other federal government agency, or authorized code inspector. Documents proving certifications need to be provided to this office for verification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 27 March 2009
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 24 December 2008 Resolved
Barge is not to carry cargo until #1 Cargo tank is properly repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 27 March 2009
Construction/Loadline › Hull › Double Hull
Issued 26 March 2008 Resolved
Stbd corner crop fractured #2 frames as marked into deep web and scarf new frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 25 April 2008
Construction/Loadline › Hull › Double Hull
Issued 26 March 2008 Resolved
Stbd corner #3 frame crop and scarf and insert corner.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 25 April 2008
Construction/Loadline › Hull › Bottom Plating
Issued 26 March 2008 Resolved
Stbd corner #4 frame crop and scarf and insert corner.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 25 April 2008
Construction/Loadline › Hull › Bottom Plating
Issued 26 March 2008 Resolved
Stbd corner grind and weld fractures as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 25 April 2008
Deck/Cargo › Holds/Tanks
Issued 10 November 2003 Resolved
REPLACE BROKEN DOGS ON FWD STBD WING TANK HATCH COVER. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Due 5 December 2003
Resolved 6 May 2004
Resolution: DOGS REPLACED.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 10 November 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 November 2003
Resolved 10 November 2003
Deck/Cargo
Issued 22 May 2001 Resolved
Demonstrate adequate testing for high media (oil) differential pressure forthermal fluid heater.
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001

Casualty record · 3

20 September 2005Routine · role: Involved in a Marine Casualty · activity 2498163
17 July 2013Routine · role: Involved in a Marine Casualty · activity 4656296
16 October 2013Routine · role: Acknowledged Pollution Source · activity 4736777
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PCS 3 (2005–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.