Inspection history · 19
23 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8241145
27 March 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8100541
18 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8059660
28 October 2024
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8019700
24 January 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853941
11 January 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7619764
1 November 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7587223
18 July 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7510285
18 October 2021
COI Inspection · DAPI Audit · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7335024
8 January 2021
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7121674
6 November 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7096468
7 August 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7028929
9 July 2020
Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7001972
6 September 2019
Internal Structural Exam · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6804983
23 October 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6561536
1 May 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6426858
28 April 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6134565
31 October 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6038537
5 May 2016
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5867294
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2025
Resolved
Aft high water alarm has audible alarm and no visual alarm. Repair/replace alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 24 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 February 2025
Resolved
Distress box is to small to hold all 12 flares. Replace box with new water tight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 24 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2025
Resolved
FWD high water alarm only has audible and no visual indicator.Replace/Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 24 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 February 2025
Resolved
Emergency procedures need to be posted on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 24 February 2025
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 January 2024
Resolved
Fume detection system test failed. Make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 29 January 2024
Resolved
Vessel was missing 4 red flares. Must replace 4 missing red flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 January 2024
Resolved
Failed to conduct annual inspection with the 90 days before and 90 days after the COI Certification Date. Must conduct annual inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 January 2023
Resolved
Vessel was un able to complete annual inspection within the 90 days before and 90 days after the anniversary date. Vessel must complete annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2022
Resolved
Vessels drydock and internal structural inspections were due by OCT 31st, 2022. Vessel is having some electrical issues and unable to start the engine to move from dock to boat yard. Vessel failed to make vessel available for drydock examinations and internal structural examinations. Must have drydock inspection completed prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2022
Resolution: Conducted drydock/ISE inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2021
Resolved
Vessel failed to have annual inspection done for yr 2020 making the COI invalid. Vessel must complete a COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 8 January 2021
Resolved 17 November 2021
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 November 2020
Resolved
Multiple fiberglass repairs required throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 18 November 2020
Resolution: Repairs made.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 6 November 2020
Resolved
Multiple frames are rotted on the vessel. Repair framing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 18 November 2020
Resolution: Repairs made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2019
Resolved
Main engine will not start. Repair & provide proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2019
Resolution: Vessel’s engine was a little slow to start, however it started on the first attempt.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2019
Resolved
Navigation lights are inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2019
Resolved 19 September 2019
Resolution: All required navigational lights are in good working order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2019
Resolved
All fire extinguishers are expired. Inspect &provide inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2019
Resolution: All fixed and portable fire extinguishers were serviced or replaced on 18SEP19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2019
Resolved
Aft bilge pump does not operate. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2019
Resolution: Aft bilge pump and high water alarm both are in good working order.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 September 2019
Resolved
Provide & post emergency instructions list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Posted
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 6 September 2019
Resolved
Life ring is required to have 60’ of floating UV resistant polypropylene line. Replace retrieval line for life float. The vessel only had 30’ of line on the life ring, and was not whipped or spliced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Line was provided and spliced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 September 2019
Resolved
Provide up to date coast pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Local area coast pilot was printed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2019
Resolved
Console had holes in it one as large approximately 3”. Blank off/cover holes in console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: All opening in the console were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2019
Resolved
Aluminum bracket for raw water strainer was wasted and hanging more than half way down. Renew raw water strainer bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Raw water strainer bracket was renewed and installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2019
Resolved
Clean back fire flame arrester.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Cleaned to perform proper operations.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 September 2019
Resolved
Provide proper operation of vapor detection & blower. Upon inspection, audible and visual alarm activated, but blower never energized. When the blower switch was switched, the blower was energized proving the blower worked. When the vapor detection system was retested, the same results happened.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Vapor detection system was repaired and tested all sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 23 October 2018
Resolved
Repair forepeak floor, and FRP tabbing from hull to deck and hull to floor.
Action required: 705 - Other - as specified
Resolved 21 December 2018
Resolution: Flooring and tabbing were renewed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 October 2018
Resolved
Remove thru-deck post for parachute towing to allow for re-inspection. Deck cutout for post was saturated in honey comb core and FRP was soft where 2 of the post fasteners were bolted thru.
Action required: 705 - Other - as specified
Resolved 21 December 2018
Resolution: All wasted core was renewed and repaired per repair plan.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 23 October 2018
Resolved
Remove port inboard swim platform fasteners on transom for re-inspection. 1 of the 4 fasteners was crushing into FRP due to possible wastage in transom.
Action required: 705 - Other - as specified
Resolved 21 December 2018
Resolution: Area IWO of swim step hardware was ground out and new core installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 October 2018
Resolved
Make sea valve (ball valve) for raw water engine cooling available for inspection.
Action required: 705 - Other - as specified
Resolved 21 December 2018
Resolution: Valve was tested and inspected sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 May 2018
Resolved
Company's drug and alcohol policy is not on board. Provide written policy.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 8 May 2018
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 May 2018
Resolved
Provide documentation of enrollment of all crewmembers in a drug and alcohol testing program.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 8 May 2018
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 May 2018
Resolved
Vessel must maintain updated charts and nautical publications. Provide required charts and publications.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 8 May 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 1 May 2018
Resolved
VHF radio must be connected to GPS or have integrated GPS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 8 May 2018
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 31 October 2016
Resolved
Renew blower ducting in engine room that is damaged.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2016
Resolution: Purchased and installed new ducting.
Stability › Watertight Integrity › General
Issued 5 May 2016
Resolved
Replace watertight gasket on forward compartment access hatch.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Vessel replaced watertight gasket on forward compartment access hatch.