Records from 2000 to 2015. Most recent: inspection, 4 November 2015.
Inspection history · 37
4 November 2015
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5790783
9 October 2015
Deficiency Check · COC-MODU Renew
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5739657
6 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4851570
2 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4851052
18 December 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4211372
9 September 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4152424
22 February 2011
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3954086
4 March 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3710617
10 March 2009
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3440158
18 March 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3167009
21 March 2007
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2893489
21 March 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608911
7 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2509898
19 April 2005
COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337617
14 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2278750
21 April 2004
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2050741
20 February 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2009865
11 January 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1991365
3 November 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1941058
24 July 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1862577
16 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1847864
27 March 2003
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1763883
26 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735542
11 September 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707543
26 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666611
22 April 2002
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1603632
1 January 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478243
12 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069919
1 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066130
31 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 16603
24 May 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461404
15 March 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1060130
9 March 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 110409
21 August 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 821616
7 July 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1052702
27 June 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 820124
30 May 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1381914
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 4 November 2015
Resolved
Launching and recovery appliances should be such that the appliance operator on the unit is able to observe the survival craft at all times during launching and recovery. L/B#1&3 have newly installed davits/winches that do not allow operator to see lifeboat as it goes down to waterline.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 19 November 2015
Resolution: Crew put a hole or what they called a "viewing port" so that the davit operator could see vessel all the way doen to the waterline
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 4 November 2015
Resolved
All lifesaving appliances should be in working order and ready for immediate use. L/B#3 external blinking navigation light on top of lifeboat is extinguished, replace/repair to original condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 9 November 2015
Resolution: Recived video from Barge Sup showing that the light on top of lifeboat # 3 was operational.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 October 2015
Resolved
Emergency source of power shall provide for a period of 18 hrs, emergency lighting at every embarkation station on deck and over the side. Multiple lights intended to illuminate muster stations and sea sear found extinguished. 1989 MODU Code 5.3.6 40 a,c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 20 October 2015
Resolution: replaced all lightbulbs requiring replacement. E-mailed pictures.
Lifesaving › Launching Appliances › Winch
Issued 13 October 2015
Resolved
All LS appliances shall be clearly marked with approval information, including the administration which approved it and any operational restrictions. LB winches for #1 and #3, newly installed, do not have approval plates attached to winches. LSA 1.2.2.9 50 c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 20 October 2015
Resolution: Provided ABS documentation via email verifying installation and design of newly installed LB winches for #1 and #3. [name withheld] accepted ABS receipt and documentation via email in lieu of plate.
Lifesaving › Launching Appliances › Winch
Issued 13 October 2015
Resolved
All machinery should be of design and consutrction ot reduce to a minimum any danger to POB, with due regard to moving parts. L/B's #1 and #3 newly installed winches do not have adequate protection for persons mustering in immediate area. 1989 MODU Code 4.1.3. 50a,c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 5 November 2015
Resolution: Pictures submitted and inspected by [name withheld] installed surrounding winches, removing personnel hazard.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 9 October 2015
Resolved
L/B shall maintain are pressure inside the L/B for aperiod of not less than 10 minutes, not falling below the outside atmospheric pressure L/B #2 one-way, transparent plastic "flapper" valve not in working condition. '74 SOLAS ('97) III / 45 16 a,c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 October 2015
Resolved 20 October 2015
Resolution: Repaired hinge and knife-edge for proper seal of flapper plate. Emailed picture.
Lifesaving › Lifebuoys › Size
Issued 22 February 2011
Resolved
Replace Liferings for quick release smokes with bridge bouys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 March 2011
Resolution: Cleared per email with picture from barge supervisor [name withheld].
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 22 February 2011
Resolved
Replace all batteries in lights for liferings with approved batteries per manufacturer specifications.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 March 2011
Resolution: Cleared per email with picture from barge supervisor [name withheld].
Construction/Loadline
Issued 1 June 2001
Resolved
ENSURE THAT ALL POWERED WATER TIGHT DOORS ARE WORKING TO THE SATISFACTION OF A ATTENDING ABS SURVEYOR. SUBMIT COPY OF FINAL ABS REPORT TO THE [name withheld].
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Construction/Loadline
Issued 30 May 2000
Resolved
Demonstrate proper operation of ODME (Oil discharge monitoring equipment) Turner design model TD-4100 on-line monitor.
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000
Fire Fighting
Issued 30 May 2000
Resolved
Repair smoke detectors to clear ESD fault indiction (four in thruster room,one in mud pit room).
Condition: Unknown
Due 30 May 2000
Resolved 30 May 2000