HAPPY BIRD

HAPPY BIRD is a 1999 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in December 2021, along with 8 deficiencies and 4 operational controls.

Records from 2016 to 2021. Most recent: inspection, 4 December 2021.

Built
1999
Last inspected
4 December 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 December 2021
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9197727
507248
Flag
ISLE OF MAN
Maury page id
psix-507248

Documentation record

Tonnage as PSIX records it2398 - Convention (Subpart B), Net Ton
11589 - Displacement, Metric Ton
7876 - Dead Weight, Metric Ton
6051 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

4 December 2021 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7362334
23 July 2020 PSC B · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7007657
22 July 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7012902
20 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6688601
17 May 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6690681
5 April 2019 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6650676
8 November 2018 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6577504
29 October 2018 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6570750
6 July 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6469154
13 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6413121
9 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6410061
24 April 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6398115
21 June 2017 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6182155
27 April 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6128811
8 February 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5808054
3 February 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5813727

Deficiency record · 8

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 December 2021 Resolved
Each cargo tank should be fitted with a high liquid level alarm operating independently of other liquid level indicators. Another sensor operating independently of the high liquid level alarm should automatically actuate a shutoff valve. (74 SOLAS (20) VII/13.1)(IGGC (93) 13.3.1) Liquid high level alarm failed to actuate automatic shtoff valve on #2 cargo tank liquid fill line.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 7 December 2021
Resolved 7 December 2021
Resolution: Alarm and valve were returned to working order prior to team's departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2018 Resolved
0830-Pipes wires (insulat.)-accident prev. Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. Identified multiple incorrect wiring connections at stuffing tubes for the following components: 1) STBD Manifold Bunkering Alarm 2) Port and STBD Manifold Lights 3) Vapor System Overdischarge and 4) Port and STBD Cargo Monitoring Instrument Panel Box located in the forecastle. 74SOLAS(97)VII/13.1, IGC Code 10.1.2
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 13 May 2018
Resolution: Cleared 01 deficiencies from MSD [name withheld] #6398115 with proper class report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 April 2018 Resolved
0750-Fire Prevention-Fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Three doors were found to be modified with closure devices penetrating the door. Doors identified no longer meet class division. 74SOLAS(97) II-2/47.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 July 2018
Resolution: Three doors that were found modified with closure devices penetrating doors in galley have been replaced and renewed. Additional fire doors were also placed in laundry room and 2 in the Engine control room. All doors were found to be approved fire doors.
Documentation › Logs/Records › Oil Record Book
Issued 24 April 2018 Resolved
1710-Oil Record Book-Any failure of the oil filtering equipment shall be recorded in the Oil Record Book Part I. Correspondence provided by vessel identified a component failure for OWS on 17MAR2018. Vessel has requisitioned part, but did not log OWS failure in ORB Part I. MARPOL(11) I/17.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2018
Resolution: Received satisfactory documentation attesting to rectified issue.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 24 April 2018 Resolved
1499-Other (Prop. and Aux. Machinery)-Associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended to reduce any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. Observed improper air connection on main propulsion engine at No. 5 Cylinder Fuel Injection Pump. 74SOLAS(97) II-1/26.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 April 2018
Resolution: Chief Engineer removed improperly installed air connection, and replaced it with the correct part.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 April 2017 Resolved
Deck Water Spray System insufficient coverage of required areas IAW IGC CODE 11.3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 29 April 2017
Resolution: Received report (HOU 1700210 28APR2017) from class stating proper operation of DWS, satisfying the requirements to clear this deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 27 April 2017 Resolved
Unable to properly calibrate Gas Detection system IAW technical manual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 29 April 2017
Resolution: Received report (HOU 1700210 28APR2017)from class stating proper operation of Gas Detection System, satisfying the requirements to clear this deficiency.
Deck/Cargo › Cargo Stowage › General
Issued 8 February 2016 Resolved
1840- INSTRUMENTATION- GAS DETECTION EQUIPMENT ACCEPTABLE TO THE ADMINISTRATION AND SUITABLE FOR THE GASES TO BE CARRIED SHOULD BE PROVIDED IAC WITH COLUMN F IN THE TABLE OF CH. 19. PSCO OBSERVED THE STARBOARD ACCOMODATION SENSOR AT THE ENTRANCE WAS INOPERABLE.- IGC CODE 1993 13.6.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2016
Resolved 8 February 2016
Resolution: THE CHIEF MATE O/B THE HAPPY BIRD HAD THE ELECTRICIAN REPLACE THE SENSOR AND RESET THE FIXED GAS DETECTION SYSTEM THEN RETESTED THE SENSOR. ALL SYSTEMS AND SENSORS FOUND TO BE SAT.