Inspection history · 55
6 April 2026
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8369473
15 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8186635
9 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8155877
22 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7964561
17 November 2023
In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7828046
11 August 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7765528
11 August 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7802901
11 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739967
19 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7535958
27 May 2022
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7460542
27 July 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7025976
17 January 2020
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6891630
16 August 2019
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6785373
12 August 2019
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6798086
12 December 2018
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6596491
12 December 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6598817
30 April 2018
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6402299
29 April 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6136223
3 August 2016
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5967725
16 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5943755
8 May 2014
MTSA Verification · Industry Initiated Exam · Administration · DAPI Audit
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4854076
17 January 2013
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4517889
25 June 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4356590
19 August 2010
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3845832
9 August 2010
Damage Survey · Deficiency Check · Spot Check (Safety) · Marine Casualty Follow Up · Administration
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3819236
29 April 2010
Administration · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3729874
24 August 2009
Spot Check (Safety)
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3668037
23 August 2009
Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3651866
1 April 2009
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3492243
13 January 2009
Administration
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3394348
9 December 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3377001
9 December 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3378713
30 July 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3284003
12 July 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3268411
1 August 2006
MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2734029
29 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2443988
23 November 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2247417
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1986238
8 March 2003
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1754466
19 June 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1638831
17 January 1999
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511024
23 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 180835
26 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185601
4 January 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 88605
3 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 45252
20 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 14997
20 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113236
12 March 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 90898
24 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182099
20 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 658835
25 August 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 369920
25 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 176312
24 October 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255548
22 January 1988
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 320972
24 January 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313999
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025
Resolved
Each life jacket must have a life jacket light securely attached to the front shoulder area of the life jacket. 04 lights were not operational and 01 light was missing. 705: Vessel restricted to daytime operations until rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2025
Resolved 18 July 2025
Resolution: All identified life jackets were fitted with new emergency lights.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2025
No resolution recorded
The name of the vessel must be marked on som elearly visible part of the port and starboard bow and stern of the vesse, using materials which result in durable markings. Name of vessel was painted on. 705: Must be fixed during vessel's next Dry Dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2027
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2025
Resolved
b)The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. These examinations may include a drydock examination, including:
MI observed vessel in drydock conducting extensive repairs to include the removal of rudders, USCG will require the vessel to conduct satisfactory underway trials with the Coast Guard prior to operations. As well as a list of all repairs that have/will be made at drydock.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2025
Resolved 17 June 2025
Resolution: Witnessed satisfactory steering gear test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 July 2024
Resolved
All watertight door seals were dry rotted and did not provide a sufficient seal. Towing vessels must be maintained and operated so that watertight integrity is not compromised. The seals must be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 22 July 2024
Resolution: Recieved pictures of replaces watertight seal.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 July 2024
Resolved
The front two white masthead lights did not illuminate upon energizing all navigation lighting. Each towing vessel must be equipped with properly working lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2024
Resolved 30 July 2024
Resolution: Recieved pictures of properly working lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 August 2022
Resolved
Shore tie cable had an unsatisfactory had an unsatisfactory splice. Electrical systems and equipment must function properly and minimize system failure and shock hazards. Remove shore tie cable slice to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 28 September 2022
Resolution: Shore tie cable was repaird.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 August 2022
Resolved
Generator gauges are not in working order. The following systems must be equipped with gauges at the machinery location: Auxiliary engine oil pressure, cooling water temp and RPM. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 28 September 2022
Resolution: Generator guage repaird.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2022
Resolved
Racor fuel filter heat protector bowl is full of fuel. All seals and gaskets must be properly maintained to prevent leaks of flammable and combustible liquid. Clean affected area of fuel to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 19 August 2022
Resolution: Owner emptied and clean bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2022
Resolved
Bilge level are in excess amounts of oily water. All seals and gaskets must be properly maintained to prevent leaks. Remove excess oily water from bilge to the satisfaction of the
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2022
Resolved 28 September 2022
Resolution: Inspected bigles and found to be dry.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 19 August 2022
Resolved
Vessel does not have sufficient exterior hand rails or chains to protect from man overboard. Rails or equivalent protection must be installed near periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed hand rails. Install hand rails to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 22 July 2024
Accommodation/Occupational Safety
Issued 24 January 1987
Resolved
VESSEL IS EQUIPPED WITH INSTALLED TOILETS AND WAS FOUND DISCHARGING RAW SEWAGE DIRECTLY OVERBOARD BYPASSING THE TYPE II MSD ON BOARD IN VIOLATION OF 33CFR159.7
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987