Records from 1983 to 2018. Most recent: inspection, 1 February 2018.
Inspection history · 104
1 February 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6347864
26 January 2018
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6345328
3 November 2017
Administrative Inspection · SIP Initial Entry
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6503225
7 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6233056
8 June 2017
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6169506
4 February 2016
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5809521
10 September 2015
Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5717854
3 September 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5233718
2 September 2015
Annual Inspection · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5718783
2 July 2015
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5835995
3 February 2015
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5063827
14 October 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5004606
7 October 2014
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5001742
9 April 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4832587
2 April 2014
COI Inspection · Deficiency Check · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4826886
11 September 2012
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4438313
20 March 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4269233
26 January 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3677984
11 February 2009
COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection · Cargo Tank Internal · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3416534
5 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3413005
28 August 2008
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3311341
28 August 2008
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3425520
23 July 2008
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3276843
29 April 2008
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3195259
5 September 2007
Periodic Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3050024
1 February 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2865570
22 September 2006
Examination of Repairs
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2786564
17 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2751035
16 August 2005
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2464788
19 April 2005
MTSA Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337513
10 May 2004
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2063705
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996971
20 January 2004
Periodic Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1988384
5 March 2003
Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1753468
30 January 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1737616
24 May 2002
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1620430
30 May 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470607
3 March 2000
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1365604
15 January 2000
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 470870
8 April 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449136
1 December 1997
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 781422
20 November 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414899
15 November 1997
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1123530
18 July 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 64234
13 January 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363913
14 May 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1083785
12 March 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 436753
20 November 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360321
10 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1192418
28 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 881210
25 April 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 861019
24 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182099
23 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842222
23 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849436
13 January 1995
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175658
16 May 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1172845
4 May 1994
Hull Examination · Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377135
30 November 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417587
19 November 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415917
3 November 1993
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 961036
24 February 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435341
30 September 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 505911
9 January 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1265348
3 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 443761
14 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920134
7 January 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 505717
12 December 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 466758
20 November 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296850
15 November 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1240756
26 October 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1236297
17 October 1990
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 902766
11 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 460736
29 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 515319
14 February 1990
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227448
12 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925161
16 August 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352935
13 January 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 497895
13 January 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202867
19 January 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318733
11 January 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1010298
9 October 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 461308
23 September 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1315152
2 September 1987
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1312579
29 June 1987
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 462708
29 June 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1317320
4 May 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1020545
23 October 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 467731
18 March 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 485105
21 February 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993184
21 February 1986
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228939
13 December 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1299103
2 December 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 995200
8 October 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 985644
26 September 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 457105
14 June 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1286548
6 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 982086
12 February 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1280930
12 February 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1289130
4 February 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 974756
5 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282209
26 July 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 977380
20 July 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 972750
23 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967043
4 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967666
Deck/Cargo › Cargo Heating › General
Issued 7 October 2014
Resolved
Thermal fluid heater low level switch not functional. Repair/Replace and demonstrate proper operation of thermal fluid heater to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2014
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 October 2014
Resolved
Cargo pump motor heat shield missing from exhaust manifold. Replace heat shield to satisfaction of marine inspector. 46 CFR 58.10-5(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2014
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 2 April 2014
Resolved
Approved MSC test procedures are not onboard for thermal fluid heater. 46 CFR 63.10-1(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 4 April 2014
Resolution: Test procedures on board barge as required.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 2 April 2014
Resolved
Repair/Replace RPM indicator on cargo prime mover.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2014
Resolution: New RPM indicator was installed and tested.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 April 2014
Resolved
Repair/Replace exhaust guards on hot surfaces of generator. 46 CFR 58.10-5(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 4 April 2014
Resolution: Exhaust guards installed over hot areas of exhaust.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 April 2014
Resolved
"Danger Keep Out" in 3" letters not posted on all cargo hatches. 46 CFR 35.05-15(b)(3)(ii)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 4 April 2014
Resolution: All cargo hatches marked as required.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 1 April 2014
Resolved
Repair/Replace RPM indicator on generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2014
Resolution: New RPM gauge was installed and tested.
Engineering › Steam Boiler (auxiliary/waste heat) › Combustion Air System
Issued 1 April 2014
Resolved
Repair/Replace blower air switch on thermal fluid heater. 46 CFR 61.35-3
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2014
Resolution: Air switch was replaced and tested all alarms on TFH
Engineering › Fuel Oil Service System › Hose
Issued 1 April 2014
Resolved
Provide protection to flexible fuel lines from vibration for cargo pump prime mover. 46 CFR 56.50-70(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2014
Resolution: Hose protection placed on fuel lines as needed.
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 April 2014
Resolved
Install ammeter on generator. 46 CFR 111.30-25(b)(3)
Condition: Placed in Improper Service
Due 2 May 2014
Resolved 9 April 2014
Resolution: Ammeter was installed and tested.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 1 April 2014
Resolved
Provide protection to hydraulic lines from vibration on cargo pump prime mover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2014
Resolution: Protection installed as required.
Construction/Loadline › Hull › Side Shell
Issued 11 September 2012
Resolved
#1 Stbd void has 15' of side shell plating and bottom knuckle that needs cropped and renewed and the #3 void has 25' of side shell plating and bottom kncukle that needs cropped and renewed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 October 2012
Resolution: Cropped and renewed to satisfaction of attending marine inspector.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 29 April 2008
Resolved
Company TBSIP Examiner identified the COFR was Out of date. Notified company who paid for a new COFR. Supporting Documentation will be faxed to office tomorrow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2008
Resolved 30 April 2008
Resolution: COFR purchased.
Deck/Cargo › Cargo Heating
Issued 30 January 2003
Resolved
Prove the proper operation of the vessels Thermal Fluid Heater and all alarms/shutdowns. Cargos requiring the operation of the Thermal Fluid Heater may not be carried prior to completion of this requirment to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Thermal Fluid Heater
Due 28 February 2003
Resolved 6 March 2003
Resolution: Found correct.
Construction/Loadline
Issued 1 December 1997
Resolved
Renew draft marks forward and aft, port and starboard.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Deck/Cargo
Issued 20 November 1997
Resolved
PRIOR TO RELOADING CARGO, TEST THERMAL FLUID HEATER SAFETIES TO SATISFACTION OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Deck/Cargo
Issued 20 November 1997
Resolved
PRIOR TO RELOADING CARGO, PRESENT THERMAL FLUID HEATER FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Construction/Loadline
Issued 20 November 1997
Resolved
PRIOR TO RELOADING CARGO, PRESENT BARGO IN A LIGHT DRAFT CONDITION FOR INSPECTION OF THE EXTERNAL HULL/SIDE SHELL.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Deck/Cargo
Issued 20 November 1997
Resolved
PRIOR TO RELOADING CARGO, PRESENT CARGO TANK COVERS/GASKETS FOR INSPECTION BY COAST GUARD.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Deck/Cargo
Issued 20 November 1997
Resolved
PRIOR TO RELOADING CARGO, OPEN & PRESENT PV VALVES FOR INSPECTION BY COAST GUARD.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Construction/Loadline
Issued 25 April 1995
Resolved
SUBMITT PROPOSAL FRO REPAIR OF DAMAGE DECK GUNALE IN WAY OF #2 STARBOARD WING TANK TO WEST BANK DETAIL OFFICE (733-1820).
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Construction/Loadline
Issued 25 April 1995
Resolved
MAKE STARBOARD VOID #2 AVAILABLE FOR INSPECTION BY COAST GUARD MARINE INSPECTOR. VALID MARINE CHEMIST CERTIFICATE TO BE MAINTAINED.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 13 January 1995
Resolved
PROVIDE FLAME SCREEN MISSING FROM BOW BOX VOID.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Construction/Loadline
Issued 13 January 1995
Resolved
MAKE PERMANENT REPAIRS TO PORT BOW BUTTON FRACTURED ON ITS UPPER INSIDE RADIUS FOR APPROXIMATELY 14 INCHES.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Unknown
Issued 4 May 1994
Resolved
THE REPAIRS TO THE APEX 1703 ARE CONSIDERED A MAJOR CONVERSION IN THAT THE REPAIRS APPEAR TO SUBSTANTIALLY PROLONG THE VESSEL'S SERVICE LIFE. PROVIDE EVIDENCE TO THE COGNIZANT OCMI THAT THE VESSEL MEETS THE DOUBLE HUL REQUIREMENTS OF OPA-90 (33 CFR 157.10D).
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Construction/Loadline
Issued 19 November 1993
Resolved
PRIOR TO THE TRANSFER OR LOADING OF CARGO MAKE STERN VOID STBD CORNER WRAPPER AT BILGE KNUCKLE AVAILABLE FOR CG INSPECTION INSIDE AND OUT. THIS CORNER IS PRESENTLY LEAKING, AND IN NEED OF REPAIRS, MAKE PROPER AND PERMENANT REPAIRS.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Construction/Loadline
Issued 19 November 1993
Resolved
PRIOR TO THE TRANSFER OR LOADING OF CARGO REMOVE "RED HAND PATCH" ON THE PORT SIDE CORNER WRAPPER/STERN HULL AT APPROX THE 5'DRAFT, MAKE AVAILABLE FOR CG INSPECTION INSIDE AND OUT, THEN MAKE PROPER AND PERMENANT REPAIRS.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Construction/Loadline
Issued 19 November 1993
Resolved
PRIOR TO THE TRANSFER OR LOADING OF CARGO AIR TEST ALL VOIDS WHERE REPAIRS HAVE BEEN MADE. NUMEROUS FRACTURES WERE FOUND AND REPAIRED, MORE WERE FOUND IN NEED OF REPAIRS. MAKE PERMENANT AND PROPER REPAIRS.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Deck/Cargo
Issued 19 November 1993
Resolved
PRIOR TO THE TRANSFER OR LOADING OF CARGO AIR TEST THE #1 AND #3 CARGO TANKS FOR POSSIBLE LEAKS AT THE UPPER CORNERS IN THE BOW AND STERN VOIDS. EVIDENCE OF LEAKAGE HAS BEEN FOUND.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Construction/Loadline
Issued 19 November 1993
Resolved
PRIOR TO LOADING OR TRANSFER OF CARGO REMOVE "RED HAND" ON THE BOW VOID STBD CORNER WRAPPER, WHERE A FRACTURE IS BEING WELDED FROM THE OUTSIDE. MAKE AVAILABLE FOR CGT INSPECTION MAKE PERMENANT AND PROPER REPAIRS.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Deck/Cargo
Issued 19 November 1993
Resolved
PRIOR TO LOADING OR TRANSFER OF CARGO REMOVE OIL AND OILY WASTE RAGS FROM UNDER CARGO PUMP ENGINES. POSSIBLE POLLUTION HAZARD.
Condition: Unknown
Due 17 December 1993
Resolved 22 November 1993
Construction/Loadline
Issued 3 November 1993
Resolved
MAKE PERMANENT REPAIRS TO AN APPROX 2' FRACTURE IN THE #1 STBD WING VOID.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Construction/Loadline
Issued 15 November 1990
Resolved
PRIOR TO NEXT LOADING, MAKE PERMANENT REPAIR TO 72"X1" HORIZONTAL FRACTURE IN WAY OF STARBOARD #1 WING VOID AT DECK EDGE.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Construction/Loadline
Issued 17 October 1990
Resolved
THE SIDE PLATE APPEARS TO BE BUCKLED AND THIN IN WAY OF THE INTERNAL FRAME MEMBERS. INTERNALLY EXAMINE ALL VOIDS AND GAUGE THE SIDE PLATE TO THE SATIFACTION OF THE ATTENDING U.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Construction/Loadline
Issued 17 October 1990
Resolved
MAKE PERMANENT REPAIR TO 3" VERTICAL FRACTURE IN WAY STERN VOID PORT CORNER WRAPPER AT DECK NO LATER THAN 17NOV90, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Construction/Loadline
Issued 17 October 1990
Resolved
MAKE PERMANENT REPAIR TO WASTED VERTICAL BUTT WELD IN WAY #2 PORT WING VOID SIDEPLATE NO LATER 17NOV90, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Construction/Loadline
Issued 17 October 1990
Resolved
PRESENT VESSEL TO THE COGNIZANT OCMI FOR AN ALL AROUND EXTERNAL EXAM OF THE VESSELS HULL FROM THE LIGHT WATER LINE NO LATER THAN 17NOV90
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Construction/Loadline
Issued 17 October 1990
Resolved
MAKE PERMANENT REPAIR TO 2" VERTICAL FRACTURE IN WAY #2 PORT WING VOID AT DECK NO LATER THAN 17NOV90, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Construction/Loadline
Issued 12 January 1990
Resolved
MAKE PERMANENT REPAIRS TO DECK GUNNEL FRACTURES AS FOLLOWS: 4" FRACTURE STBD. BOW CORNER WRAPPER, 24" FRACTURE ON KEVEL NO. 1 STBD. WING VOID, 18" FRACTURE NO. 3 STBD. WING VOID AND 6" FRACTURE STBD. STERN CORNER WRAPPER IN ACCORDANCW WITH 46 USC 3313(A)
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Construction/Loadline
Issued 13 January 1989
Resolved
PAINT DRAFT MARKS.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Electrical
Issued 13 January 1989
Resolved
REPLACE MISSING ELECTRICAL BOX COVER AFT.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 13 January 1989
Resolved
DEWATER BOW VOID AND #1P VOID (APPROX 4" OF WATER IN EACH)
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 2 September 1987
Resolved
4-6" FRACTURE AT DECK KNUCKLE / STERN LOG / CORNER WRAPPER JUNCTION. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Construction/Loadline
Issued 2 September 1987
Resolved
STARBOARD STERN TIMBERHEAD HAS BEEN TORN OFF. REPAIR OR REPLACE AS REQUIREDTO SATISFY THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Deck/Cargo
Issued 4 May 1987
Resolved
PROVIDE INSTRUCTION BOOKLET FOR THERMAL FLUID HEATER AS REQUIRED BY 46 CFR 63.05-95.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Engineering
Issued 21 February 1986
Resolved
CONDUCT TEST OF THERMAL FLUID HEATER AS REQUIRED BY 46CFR 61.30-15 AND 46 CFR 61.30-20 RESULTS OF TESTS TO BE TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO 21MAR86.
Condition: Unknown
Due 21 February 1986
Resolved 21 February 1986
Construction/Loadline
Issued 21 February 1986
Resolved
MAKE THE BARGE AVAILABLE FOR AN INTERNAL STRUCTURAL EXAMINATION.
Condition: Unknown
Due 21 February 1986
Resolved 21 February 1986
Deck/Cargo
Issued 8 October 1985
Resolved
CONDUCT ANNUAL REQUIRED TESTS ON (A) CARGO PIPING (B) RELIEF VALVE (C) CARGO HEADER GAGE
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Deck/Cargo
Issued 8 October 1985
Resolved
REPLACE RUSTED OUT SPARK ARRESTOR ON LEFT EXHAUST MANIFOLD PRIOR TO OPERATION OF ENGINE.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Construction/Loadline
Issued 6 April 1985
Resolved
MAKE PERMANANT REPAIRS TO HOLE AND STRUCTURAL DAMAGE IN WAY OF #1 AND #2 STARBOARD WING VOIDS
Condition: Unknown
Due 6 April 1985
Resolved 6 April 1985
Construction/Loadline
Issued 4 February 1985
Resolved
MAKE PERMANANT REPAIRS TO FRACTURES IN #2 AND #3 STARBOARD WING VOID, ALSO #1 AND #3 WING VOID.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Construction/Loadline
Issued 4 February 1985
Resolved
DEWATER BOW AND STERN RAKES AND MAKE AVAILIBLE FOR INSPECTION.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Construction/Loadline
Issued 4 February 1985
Resolved
CLEAN MAIN DECK AREA OF OIL IN VICINITY OF CARGO MACHINERY.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Engineering
Issued 4 February 1985
Resolved
REINSTALL COUPLING GUARD ON CIRCULATING PUMP.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Engineering
Issued 26 July 1984
Resolved
PROVE PROPER OPERATION OF SAFETY RELIEF VALVE AND THAT IT IS OF THE ADEQUATE SIZE. TEST TO SATISFACTION OF COGNIZANT OF OCMI.
Condition: Unknown
Due 26 July 1984
Resolved 26 July 1984
Construction/Loadline
Issued 20 July 1984
Resolved
MAKE PERMANENT REPAIRS TO DAMAGE IN WAY OF SOFT PATCH ON STARBOARD BOW SHELL PLATE.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Deck/Cargo
Issued 20 July 1984
Resolved
REPLACE FAN GUARD ON CARGO PUMP ENGINE.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Deck/Cargo
Issued 4 February 1983
Resolved
HYDRO TEST THERMAL FLUID HEATER IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1983
Resolved 4 February 1983
Deck/Cargo
Issued 4 February 1983
Resolved
OPERATE THERMAL FLUID HEATER TO PROVE OPERATION OF SAFETY DEVICES.
Condition: Unknown
Due 4 February 1983
Resolved 4 February 1983
Deck/Cargo
Issued 4 February 1983
Resolved
INSTALL NEW TACHOMETER ON CARGO PUMP ENGINE.
Condition: Unknown
Due 4 February 1983
Resolved 4 February 1983
Deck/Cargo
Issued 4 February 1983
Resolved
MAKE PERMANENT REPAIRS TO HYDRAULIC PUMP FOR THE HYDRAULIC ACCUMULATOR.
Condition: Unknown
Due 4 February 1983
Resolved 4 February 1983
Unknown
Issued 4 February 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL APEX 1703, DN557584
Condition: Unknown
Due 4 February 1983
Resolved 4 February 1983