Inspection history · 32
24 June 2026
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8413483
26 February 2026
Deficiency Check · Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8317139
21 July 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8194360
21 May 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8140756
20 March 2025
Drydock Exam · Administrative Inspection · In-Service Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8097058
7 February 2025
Annual Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8072415
13 February 2024
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7865079
8 February 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7862136
9 February 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7634434
14 January 2023
In-Service Inspection · Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7621457
1 November 2021
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7343184
22 October 2020
MTSA Verification · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7082421
8 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6950382
21 November 2011
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4193216
11 February 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3943342
30 July 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3851911
17 August 2009
MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3568784
7 March 2008
Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3160216
11 June 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2679867
9 June 2005
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2384850
3 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2058352
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973422
28 October 2002
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1697539
28 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101673
24 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182099
22 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 365512
3 November 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 362151
26 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 670356
21 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 528825
5 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 645183
28 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 89531
19 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 162994
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 February 2026
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel missed its annual inspection. Complete satisfactory annual inspection prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 March 2026
Resolution: Conducted annaul inspection on 11MAR26.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 26 February 2026
Resolved
Master was missing his medical card. Vsl must have a valid mmc with the correct endorsements for towing as well as a valid medical card, prior to operating the vsl.
Action required: 705 - Other - as specified
Resolved 24 June 2026
Resolution: Medical Certificate was provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 February 2026
Resolved
Vsl had a trouble alarm for the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 26 March 2026
Resolution: Vsl fixed trouble alarm.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2026
Resolved
Vsl has a 10 B:C portable extinguisher protecting the paintlocker/flam locker. Vsl is requires to replace the extinguisher with the required 40 B.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 23 March 2026
Resolution: Vsl replaced 10 B:C with an 80 B:C extinguisher.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 February 2026
Resolved
Vsl had excessive oil accumulation in the both shaft seal pockets in the e/r.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 23 March 2026
Resolution: Vsl cleaned bilges of excessive oil.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 February 2026
Resolved
STBD MDE had an inop oil pressure guage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 30 April 2026
Resolution: Vsl replace the l/o psi gauge, sat operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 February 2026
Resolved
Both steering pumps were missing pressure guages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 22 April 2026
Resolution: Installed pressure guages.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 26 February 2026
Resolved
Vsl was missing low level for the steering gear tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 22 April 2026
Resolution: Low level guage was installed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 February 2026
Resolved
E/r general alarm bell was inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 22 April 2026
Resolution: Audio and visual alarm were operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026
Resolved
Vsl did not log or conduct engine/gen alarm set point testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 4 May 2026
Resolution: Third party testing conducted.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 26 February 2026
Resolved
VHF radios did not have position plugged into them for DSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026
Resolved 22 April 2026
Resolution: GPS was reading on radio.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 28 March 2025
Resolved
During vessels credit internal structural examination, numinous bottom shell and fwd WTB frames in the port and starboard lazarettes were wasted beyond 25% of original. Vessel refloated on 29MAR2025. Prior to operating in commercial service, all wasted frames in the lazarettes are to be crop out and renewed to original as required by 46 CFR 137.330(b).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 15 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 February 2024
Resolved
The vessel must have on board a properly installed, operational Coast Guard type-approved AIS Class A Device.
AIS was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2024
Resolution: New AIS installed. Op tested, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 8 February 2024
Resolved
Each vessel must have the following: An illuminated rudder angle indicator in the wheelhouse.
Rudder angle indicator was inaccurate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 13 February 2024
Resolution: Calibrated rudder angle indicator.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 8 February 2024
Resolved
Each towing vessel must be equipped with... an echo depth sounding device.
No depth sounder onboard.
Install depth sounder at next drydock availability. Mitigate risk by utilizing a lead line depth sounder.
Action required: 705 - Other - as specified
Resolved 13 February 2024
Resolution: Owner has a lead line onboard to take depth soundings.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 8 February 2024
Resolved
Verify that bilges... are free from excessive oil.
Excessive oil observed under generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2024
Resolution: Cleaned bilges.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2023
Resolved
Each life float and rigid buoyant apparatus must be
fitted with a lifeline, pendants, a painter, and
floating electric water light approved under approval
series 161.010. Port floating electric water light was
missing battery, starboard light had an expired battery.
Vessel is restricted to daytime operations until
rectified.
Action required: 705 - Other - as specified
Resolved 3 March 2023
Resolution: Attended the vessel, rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 February 2023
Resolved
A towing vessel must carry a combination of day and
night visual distress signals indicated in Table 141.370
of § 141.370 for specified areas where the vessel
operates. Based on routes and conditions, vessel is
required to carry 6 day and 6 night distress signals.
Vessel was missing two day signals. Vessel is restricted
to operating within 3NM of shore until rectified.
Action required: 705 - Other - as specified
Resolved 3 March 2023
Resolution: Attended the vessel, rectified.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 9 February 2023
Resolved
When operating a vessel on a body of water where the
discharge of treated or untreated sewage is prohibited
by the Environmental Protection Agency under 40 CFR
140.3 or 140.4, the operator must secure each Type I or
Type II device in a manner which prevents discharge of
treated or untreated sewage. Acceptable methods of
securing the device include - (1) Closing the seacock and removing the handle; (2) Padlocking the seacock in the
closed position; (3) Using a non-releasable wire-tie to
hold the seacock in the closed position; or (4) Locking
the door to the space enclosing the toilets with a
padlock or door handle key lock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 3 March 2023
Resolution: Attended the vessel, rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 February 2023
Resolved
The following systems must be equipped with gauges at
the machinery location: Main engine cooling water
temperature; Auxiliary generator engine cooling water
temperature. Both gauges were unreadable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 3 March 2023
Resolution: Attended the vessel, rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2023
Resolved
Electrical components that pose an electrical hazard
must be in an enclosure. Cover missing over starboard
batter box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 3 March 2023
Resolution: Attended the vessel, rectified.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2023
Resolved
Unless an exemption is granted under § 26.09 and except
as provided in paragraph (a)(4) of this section, this
part applies to: every towing vessel of 26 feet or over
in length while navigating. Missing Bridge to Bridge
Certificate, Safety Radiotelephony Certificate, Radio
Station Authorization.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 4 April 2023
Resolution: Closed outstanding deficiency per CVC’s request.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 January 2023
Resolved
A towing vessel must be maintained and operated so the water tight integrity and stability of the vessel are not compromised. A breach was discovered in the STBD aft exterior corned IWO the bulwark, main deck and hull intersect. Provide repair proposal prior to repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2023
Resolution: ground and rewelded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 January 2023
Resolved
A towing vessel must be maintained and operated so the water tight integrity and stability of the vessel are not compromised. A breach was discovered in the STBD aft exterior corned IWO the bulwark, main deck and hull intersect. Provide repair proposal prior to repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2023
Resolution: New shaft packing. No leaks.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 January 2023
Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel. Vessel replaced wasted and deteriorated deck hatches with used barge hatch covers that were not suitable causing flooding in compartments.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2023
Resolution: Hatches reseated and tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 14 January 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather tight function properly. Master replaced vessel's wasted deck hatches with used barge hatches that did not fit and were not water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2023
Resolution: hatches repaired.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 November 2021
Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover, and must be operable from a safe place outside the space where the valve is installed. Stbd side fuel shut off valve was inoperable from outside the space. Repair fuel shut off valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2021
Resolved 10 November 2021
Resolution: Fuel shut off valve repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021
Resolved
Internal combustion engine exhaust ducts must be insulated with non combustible insulation if less than 18 inches away from combustible material. Lagging was missing on portions of stbd engine exhaust piping. Replace or repair lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 10 November 2021
Resolution: Lagging added, repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 November 2021
Resolved
Each towing vessel must be equipped with sound signals in accordance with COLREGS. Ship's horn was inoperable. Repair ship's horn.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2021
Resolved 10 November 2021
Resolution: Ship's horn repaired.