Records from 2014 to 2026. Most recent: inspection, 23 July 2026.
Inspection history · 82
23 July 2026
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8440926
16 March 2026
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8326384
13 March 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8321320
7 July 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8168594
21 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8116254
21 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8116574
6 January 2025
PSC A
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8051331
30 September 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8018251
13 May 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7911544
29 January 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7857019
24 January 2024
MSP Periodic Oversight
Type not classified · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7849592
16 January 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7849599
29 October 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7815935
25 October 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7814406
24 October 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7815042
29 July 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7780815
21 July 2023
MSP COI Oversight · MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7748063
15 July 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7821207
4 June 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7703001
24 February 2023
MSP Periodic Oversight · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7641042
15 November 2022
Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7597582
18 September 2022
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7565650
3 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7524284
25 July 2022
Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 7515942
29 June 2022
Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7490803
23 June 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7483291
5 May 2022
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7444348
3 May 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7444323
16 February 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7397075
28 January 2022
Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7387008
29 December 2021
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7375792
15 December 2021
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7368303
10 December 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7365767
5 August 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7277808
30 July 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7276496
23 July 2021
MSP Annual Oversight · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7265447
22 March 2021
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7160339
17 March 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7157654
28 February 2021
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7147684
17 February 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7141713
27 January 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7131648
25 January 2021
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7129968
19 January 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7127134
24 December 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7116020
9 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7109344
18 November 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7097637
17 November 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7096605
28 October 2020
Annual Inspection · MSP Periodic Oversight
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7078817
28 October 2020
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7093389
16 October 2020
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7076735
10 October 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7075745
1 September 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7048002
31 August 2020
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7045126
17 August 2020
MARPOL Annex I Examination · In-Service Inspection · Damage Survey · Deficiency Check · ISM Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7036207
12 August 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7030899
8 May 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950308
17 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6928259
13 February 2020
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6908249
13 December 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6873143
16 October 2019
Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6835321
16 August 2019
MTSA/ISPS Verification · MSP COI Oversight · COI Inspection
Physical examination · Activities Europe · Activity 6773399
2 May 2019
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6675773
30 April 2019
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6674799
25 January 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6614868
5 November 2018
Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6575453
15 October 2018
In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6561958
27 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6459580
11 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6446446
30 April 2018
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6402167
25 April 2018
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6399281
21 April 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6399305
21 April 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6436699
5 March 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6365743
29 November 2017
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6314501
27 July 2017
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6211299
28 April 2017
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6136555
2 January 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6329791
9 December 2016
Administrative Inspection · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6053145
23 November 2016
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6046227
20 April 2016
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5858207
15 March 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5834143
16 February 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5815632
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Attending MI’s noted that the Port side open deck fire main isolation valve fire that supply’s the car deck is wasted. Additionally, the hardware to secure the main hydrant valves throughout the open deck were in a poor state of repair.
SOLAS 97 II-2/14.2.1.3 2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems; and Smoke detection alarm systems. Attending MI’s noted that the two smoke detectors located in the steering compartment didn’t not sound an audible alarm in the engineering control station to alert watch standers.
SOLAS 97 II-2/14.2.1.3 2.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: emergency vent louvers used to isolate the emergency generator space have inadequate sealing gaskets and hinges and dogging mechanisms require maintenance.
SOLAS 97 II-2/14.2.1.3 2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: emergency vent louvers used to isolate the port engine-room natural ventilation and the No.1 engine room vent fan cover were providing an inadequate seals due to the poor condition of the sealing metal surface.
SOLAS 97 II-2/14.2.1.3 2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 August 2023
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, the following functional requirements shall be met:means of control for flammable liquids in the space shall be provided; relocate lube oil storage buckets vent intake for E Generator to adequate location.
SOLAS 97 II-2/5.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 4 August 2023
Resolved
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. Personal equipment shall consist of the following: Axe with a handle provided with high voltage insulation. A Firefighters axes shall be provided for each required SCBA with means to safely attach it to the firefighters ensemble.
SOLAS 97 II-2/10.10.1 &
FSS Code 3.2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 August 2023
Resolved
Emergency lighting shall be provided in means of escape locations. Attending MI noted that not all lighting supplied in emergency escape trunks leaving engineering spaces was illuminated.
SOLAS 97 II-2/13.3.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2023
Resolved
Non-metallic expansion joints in piping systems, if located in a system which penetrates the ship's side and both the penetration and the non-metallic expansion joint are located below the deepest load waterline, shall be inspected as part of the surveys prescribed in regulation 1/ 10(a) and replaced as necessary, or at an interval recommended by the manufacturer. Attending MI noted that there was no system in place to track the maintenance and replacement of the installed expansion joints.
SOLAS 04 II-1/27.9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 4 August 2023
Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Remove 11.3 from automation PSTP for emergency generator as the engine is air cooled and high water temp is not applicable.
SOLAS 97 II-2/46.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 August 2023
Resolved
Operational readiness Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Attending MI’s noted that the forward mooring deck starboard side life ring bracket wasted.
SOLAS 97 III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: emergency vent accessible and maintenance needs to be addressed in the following locations. 1. Officers mess vent 90. 2. elevator shaft vent / dog seized 3. Dry store room 1 and 2 dampers need a line in order to pull as they are out of reach. 4. Laundry damp dry seized.
SOLAS 97 II-2/14.2.1.3 2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions cable penetrations located in Locker #6 storeroom is missing adequate fire stop.
SOLAS 97 II-2/14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 August 2023
Resolved
Means of control shall be provided for stopping oil fuel transfer pumps, oil fuel unit pumps, lubricating oil service pumps, thermal oil circulating pumps and oil separators (purifiers). Attending MI’s noticed that the ESS #1 is not protected from accidental activation, restore protective cover to original specifications.
SOLAS 97 II-2/5.2.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 4 August 2023
Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power. During the deck walk it was noted that the following lights were inoperable. Cargo deck 12 center aft, Cargo deck 11 hold 3 starboard side.
SOLAS 04 II-1/40.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 August 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems; Attending MI noted that there was an active fault on the Fire detection panel fault that could not be cleared restore to full operations.
SOLAS 97 II-2/14.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 10 August 2023
Resolution: ABS Class surveyor [name withheld] attended the vessel on August 7th 2023 under work order 5977496 and attested to satisfactory correction of this item.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 24 February 2023
Resolved
Numerous technical and operational deficiencies outlined below indicate a serious failure and lack of effectiveness of the implementation of the vessel's safety management system (SMS). Prior to lifting this flag-state detention, an SMS audit must be carried out by the Recognized Organization and submitted to Sector San Diego along with details of any corrective actions sternming from the results of the audit.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: Cleared based on the satisfactory ISM audit report performed by ABS.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 February 2023
Resolved
During a fire drill in the ship's galley, the fire team entered the space with no means of communication with the on-scene leader, and no plan to communicate details to the on-scene leader outside the space. During drill debriefs, the crew stated that they thought they were supposed to be outfitted with radios, but that they had never exercised any means of communication between the fire team and the on-scene leader. No one interviewed onboard had any knowledge of what fire training or guidance on communication during fire events was included in the company's SMS procedures or SOLAS training manuals, nor had they been told the master's expectations for fighting fires.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: Cleared based on the satisfactory fire drill.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 24 February 2023
Resolved
Firefighters outfits were observed to be ineffective at providing adequate protection during the fire drill; the flash hoods were degraded and didn't cover the
firefighters' skin and the helmets didn't fit the
firefighters nor provide protection against impact as
required by the FSS Code. Two (02) SCBA bottles were
half full.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: gear was adequate during the fire drill
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2023
Resolved
The fire detection panel was found to have 05 active
faults, make repairs to faulty loops circuits and prove proper operation of the system. SOLAS 74 am ('97 conEd) Chap. II-2/Reg 13
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: panel faults cleared. Random test of smoke detectors in cargo holds all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2023
Resolved
The L/P CO2 pressure vessel was found to have been
hydrostatically tested in December 2012, provide
evidence of hydrostatic testing from last 10 years.
Cite: NVIC 01-13 ch1 enclosure 3 paragraph 1.14 which requires compliance with 46 CFR 61.10-5(g).
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 9 December 2024
Resolution: Must be completed at next drydock per Seabulk Proposal (November 2024). Gauging report provided to CG from last dry-dock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2023
Resolved
The L/P CO2 sight glass was found to be iced up and unreadable, provide approved means for crew to gauge
liquid level in the tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2023
Resolved 27 March 2023
Resolution: Sight glass heater installed and surveyed by class.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2023
Resolved
The refrigeration units for the L/P CO2 storage tank
were both found to be running continuously throughout
the 4 hour inspection, make class society approved
repairs so that only one refrigeration unit is needed to maintain pressure and the other is in standby.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: Compressors now running independently
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
12 lithium Ion portable tool batteries / chargers were found to be powered by to two daisy chained power strips in the ships office, provide each charger with dedicated electrical outlets.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: Charging station is cleaned up, new company procedure for Li-Ion and power strips to be developed per ISM audit nonconformity.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2023
Resolved
2 smoke detectors were found to be broken in the purifier room and held in place with duct tape, replace broken smoke detectors with approved type.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: Detectors renewed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2023
Resolved
The G/E lube oil settling tank support framing has ahistory of cracked steel and weld repairs made. New additional cracks were discovered on tank support framing, provide vibration analysis and structural re- design of the suspended tank support framing. Additionally, the bottom plate of the tank appears to be cracked and leaking, conduct non destructive testing in suspected area. SOLAS 74 am ('97 ConEd) Chap. II-1/Reg
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2024
Resolved 6 January 2025
Resolution: Added as ABS Condition of Class 815.10. Tank shall remain empty until root cause is identified and permanent repairs are made (Nov 2024 availability).
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 February 2023
Resolved
The escape hatch on the port side of deck 12 (hatch 2) is inoperable/blocked due to frozen/corroded dogs.
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: escape hatch is operable
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 February 2023
Resolved
9 deck vent dampers and 1 engine room vent damper ailed to close on testing. Repair and retest
Action required: 30 - Ship detained
Resolved 2 March 2023
Resolution: all vent dampers operable
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 24 February 2023
Resolved
The serialized tag affixed to the Oily Water Separator overboard valve was found broken, with no correspor.ding entry in the MARPOL Seal Log required by the Safety management System. Conduct seal audit to validate that controlled valves are sealed in accordance with corr.pany SMS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: tag renewed, logs scrubbed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 February 2023
Resolved
Log entries on the deck log in the bridge were not signed by the master and were missing numerous required entries per the company's SMS procedure for log-keeping.
Bring log into compliance with SMS Procedure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: New logs sat, follow-ups per nonconformity in ISM audit
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
Stores were being kept in the "reception room" which likley creates a fire load larger than authorized for a category 3 space categorization (accommodation spaces).
Remove excess stowage in this accommodation space er
prove that this compartment is authorized for stowage of
shios stores.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: stowage cleaned up
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2023
Resolved
Class A doors leading to the Lifeboat Deck from crew's accommodation did not self close.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Self-closers operational
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 24 February 2023
Resolved
Unauthorized repairs were conducted to the Emergency Generator Exhaust which were covered by inadequate insulation. Obtain approval from class for repairs conducted and re-cover the exhaust with approved insulation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2023
Resolved 23 March 2023
Resolution: Muffler renewed, satisfactory installation veriried by ABS surveyor
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2023
Resolved
The structural fire protection insulation was found to be missing/ damaged in the emergency generator overheard, make class society approved repairs. SOLAS 74 am ('97 ConEd) Chap. II-2/Reg 44
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: insulation sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2023
Resolved
The structural fire protection insulation was found to be missing/ damaged in numerous places in the L/P CO2 room, make class society approved repairs. SOLAS 74 am ('97 ConEd) Chap. II-2/Reg 44
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: insulation sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2023
Resolved
The salt water cooling pipe for the L/P CO2 refrigeration units were found to be recently repaired and missing numerous pipe support brackets, provide piping with adequate support brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: pipe hangers added
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
Outdoor cooking charcoal was found in the hydraulic pump unit room and created an increased combustible fire risk, remove charcoal and properly stow. SOLAS 74 am
('97 ConEd) Chap. II-2/Reg 2.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Stowage cleaned up
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 February 2023
Resolved
Cargo hold ventilation fan D-6S was found to be tagged out and inoperable, notify class society of equipment failure and provide data that the current configuration meets the cargo deck air changing requirements. SOLAS 74 am {'97 ConEd) Chap. II-2/Reg 38
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: remaining ventilation sat per calcs from master
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
The 440 volt switchboard was found to low resistance(ground) to the vessel's hull, isolate grounded circuit and make repairs. SOLAS 74 am . ('97 ConEd) Chap. II-2/ Reg
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Ground isolated to deep fat fryer which is now tagged out
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2023
Resolved
Numerous dead ended electrical cables were found with
bare conductors and resting in the bilge of the purifier room, provide class approved termination of conductor or remove entirely. . SOLAS 74 am . (1 97 ConEd) Chap. II-2/ Reg 40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Dead end cables removed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2023
Resolved
The fire hydrant in the steering gear room was found with the connected hose and hose cradle approximately 12 feet from the hydrant with the hose faked out on the
deck, arrange hydrant and hose as approved by the fire plan. SOLAS 74 am. (' 97 ConEd) Chap. II-2/Reg 4.7.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Stowed hose no longer a tripping hazard
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2023
Resolved
A box of wood scraps was found in vicinity of the main propulsion engine and created a combustible fire risk, remove wood scraps and properly stow/ dispose. SOLAS 74 am. (' 97 ConEd) Chap. II-2/Reg 2.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: wood removed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 February 2023
Resolved
A large majority of the Periodic Safety Test Procedures
had not been completed within the timeline designated
by the company's safety management system. Perform an audit of the PSTP 109:s and perform reguired tests.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: PSTPs caught up, spot checked a couple with sat results
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 February 2023
Resolved
The fire main valve near the water sterilizing unit excessively corroded. Prove operation of the valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: valve renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2023
Resolved
The isolation valve on the G/E LO Overflow Tank is
inoperable, and tagged out in the open position. Repair
valve and prove operation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: Valve is operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2023
Resolved
Fuel vents located just aft of the port and starboard lifeboats have flamescreens that are partially detatched from the vent line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Flame screens renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2023
Resolved
Degraded fire hose located at fire station Number Four in the main crew's accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: hose renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2023
Resolved
Ballast water treatment system was found with multiple faults and in an alarm state, prove proper operation of Ballast water treatment system. 33 CFR 151
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: Faults cleared
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2023
Resolved
02 power strips were providing various galley appliances power, provide dedicated outlets for each galley
appliance. ('97 ConEd) Chap. II-2/Req 40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Power strips removed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. Internally inspect the insets located on the forward and aft boundaries of the port side "DOT" Diesel Oil Tank at the time of the Internal Structural Examination due before 3Dec2022.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 December 2022
Resolved 2 December 2022
Resolution: Port DOT was examined and frame was repaired. Hull inset to be addressed at next drydock due to it being near the waterline at the time of survey, condition still outstanding in ABS database.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2022
Resolved
The structure, machinery, and equipment of a cargo ship as referred to in paragraph (b)(i) shall be subject to a minimum of two inspections of the outside of the ship’s bottom during any five year period. Inspect the vessel's sea valves in accordance with NVIC 1-89 as outlined within the provisions in the ship's UWILD enrollment approval letter dated June 26, 2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2022
Resolved 2 December 2022
Resolution: See narrative. Deficiency was cleared and approved by MIDET CID.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2022
Resolved
The structure, machinery, and equipment of a cargo ship as referred to in paragraph (b)(i) shall be subject to a minimum of two inspections of the outside of the ship’s bottom during any five year period. Complete the rudder and stern tube bearing clearance readings in accordance with NVIC 1-89 as outlined within the provisions in the ship's UWILD enrollment approval letter dated June 26, 2020.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2022
Resolved 2 December 2022
Resolution: See narrative. Deficiency was cleared with the approval of MIDET CID.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. Repair stern tube seal that reportedly has leaked 3 liters/week since 2020. Provide Class report attesting to proper repair of seal.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 December 2022
Resolved 2 December 2022
Resolution: Stern tube seal was replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 July 2022
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization. Replace fire extinguisher No. 19 that was found to be passed its annual required servicing date.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 11 August 2022
Resolved 11 August 2022
Resolution: Replaced fire extinguisher with spare that had been serviced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 25 July 2022
Resolved
The company should ensure that changes to documents are reviewed and approved by authorized personnel. Update the PRO-HS-10 LOCK OUT/TAG OUT to reflect the new procedures regarding indexing, paperwork management steps, and Log form numbers. 74 SOLAS(20) IX/3.1, ISM 11.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 11 August 2022
Resolved 11 August 2022
Resolution: Vessel began CAR process to update lock out, tag out procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 July 2022
Resolved
Befor the ship leaves port and at all times during he voyage, all life-saving appliances shall be in working order and ready for immediate use. Internal lifeboat lowing mechanism does not allow boat to be lowered all the way down to the water. 74 SOLAS (97) III/19.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2022
Resolved 9 July 2022
Resolution: Port lifeboat successfully lowered from stowed position to water by boat crew using remote brake release cable. See narrative for details.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 July 2022
Resolved
External openings required to be watertight in accordance with paragraph 1 shall be of sufficient strength and, except for cargo hatch covers, shall be fitted with indicators on the bridge. Indicator light on bridge for AFT loading ramp is indicating ramp is in the open position when it is closed. 74 SOLAS (97) II-1/25-10.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 September 2022
Resolved 11 August 2022
Resolution: Verified repair and operation of stern ramp closure indicator light as part of MISLE Activity 7515942.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 July 2022
Resolved
Ship operations - ISM - In meeting these requirements the company should ensure that records of these activities are maintained. The vessel lockout tag out log has missing paperwork. Items throughout the engine room to include fans are tagged out but there was no paperwork filled out to show who tagged the equipment out and for what reason or what must occur to clear the equipment IAW the companys procedures for lock out tag out. Lock out tag out binder must account for all equipment that has been tagged out for safety of the crew. 74 SOLAS (20) IX.3.2, ISM 10.2.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2022
Resolved 11 August 2022
Resolution: Verified correction of Lock out/Tag out log as part of activity 7515942.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 July 2022
Resolved
Stairways which penetrate only a single deck shall be protected at least at one level by at least "B-0" class divisions and self-closing doors. Multiple A-0 fire doors on several levels were not self-closing. 74 SOLAS (97) II-2/46.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 July 2022
Resolved 8 July 2022
Resolution: Adjustments made to A-0 fire doors and are now self-closing.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 August 2021
Resolved
On August 2nd, 2021, received a notification that M/V GREEN COVE had sailed short 02 Able Seaman enroute to the Port of Newark, New Jersey from the Port of Jacksonville, FL on July 31st, 2021. Due to the uncertainty of replacements for these open billets to be filled prior to the vessel departing the Port of Newark, New Jersey and in accordance with Title 46 Code of Federal Regulations (CFR) Part 15.725 the vessel will be restricted from departing the Port of Newark, NJ until the vessel is fully manned in accordance with the Certificate of Inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 July 2021
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces.
#1 and #2 E/R vent closures did not work upon initial testing.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2021
Resolution: Ship's crew performed corrective maintenance, witnessed re-testing, sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 July 2021
Resolved
1. Stairways which penetrate a single deck shall be protected at least with "B-0" class division and self closing doors.
2. Doors fitted in boundary bulkheads of machinery spaces of Category A shall be self closing.
1. Stairway self closing door going to the bridge is not closing.
2. The aft steering gear room door is not closing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 10 August 2021
Resolution: The two fire doors were adjusted and close properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 July 2021
Resolved
Any required fixed fire detection system shall be capable of immediate operation at all times.
(02) detectors, Deck 3 and Deck 12, are not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 10 August 2021
Resolution: Vessel crew renewed two smoke detectors and fault has cleared on the fire detection panel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2021
Resolved
Ships shall be provided with fire hoses which shall be to the satisfaction of the Administration.
(03) 2 inch and (03) 1-1/2 inch fire hoses were found defective during a hydro test.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2021
Resolution: Vessel had spare hoses onboard and replaced the defective hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 July 2021
Resolved
Every ship shall be provided with documentary evidence to the satisfaction of the Administration, of its fitness to operate with periodically unattended machinery spaces.
The ship's Lock out/Tag out procedures/log are in disarray and need to be properly accounted for.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2021
Resolved 17 August 2021
Resolution: Vessel crew conducted training regarding Lock out/Tag out procedures. They also accounted for equipment still tagged out. Follow up will be done during next inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 October 2020
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which intended and shall be so installed and protected as to reduce to a minimum any danger.
Numerous gauges were observed throughout the engineering spaces missing protective covers. Provide missing covers.
SOLAS 74a II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vssel provided photographs of installed missing covers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2020
Resolved
Cables and wiring shall be installed in such a manner as to avoid chafing and damage.
Electrical cabling in the engine room was found missing metallic supports and zip tied in place. Provide adequate permanent supports.
SOLAS 74a II-1/45.5.5
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vessel provided photographs of metallic wire hangers installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2020
Resolved
All metal sheathes and armour of cable shall be continuous and shall be earthed.
Electrical cables found with deteriorated sheathing in way of steering solenoids #1 and #2 and in way of #3 generator. Replace damaged sheathing.
SOLAS 74a II-1/45.5.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vessel provided photographs of repaired wire cables.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2020
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner.
A junction box and a transformer were found missing covers in the machine shop. Provide covers.
SOALS 74a II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vessel provided photographs of installed missing covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 October 2020
Resolved
Safe and effective means of ascertaining the ammount of oil fuel contained in any oil fuel tank shall be provided.
Boiler fuel oil settling tank level sensor was found disconnected. Demonstrate means of determining level.
SOLAS 74a II-2/4.2.2.3.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 November 2020
Resolution: Vessel removed internal settling tank level sensor and demonstrated that they are using external sight glass to determine level.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 October 2020
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks.
Self closing doors in the galley were found with hold-back hooks. Remove hold-back hooks on self-closing doors.
SOLAS 74a II-2/47.2
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2020
Resolution: Vessel provided pictoral evidence that hooks were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2020
Resolved
Safety relief valves for steam or air service shall be provided with a substantial lifting device so that the disk can be lifted off of its seat when the pressure in the vessel is 75 percent of that at which the valve is set to blow.
Receivers for quick closing valves and emergency fire pump were not fitted with lifting devices on the safety relief valves. Provide safety relief valves with lifting devices.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2020
Resolved 28 February 2021
Resolution: Safety relief valves with lifting devices installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2020
Resolved
After any survey of the ship under regulations 7, 8, 9, and 10 has been conducted, o change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration.
The MSD salt water flushing valve was found leaking. Repair leak.
SOLAS 74a I/11.b
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vessel tightened loose bonnet and resealed with thread sealant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 28 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that th ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Metallic flexible hoses in way of stern ramp hydraulic system were found oil soaked an with damaged sheathing. Replace hoses.
SOLAS 74a I/11.a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 November 2020
Resolution: Vessel replaced flexible metallic couplings.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that th ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Excessive items were found stored in the low pressure CO2 room. Remove escess items.
SOLAS 74a I/11.a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2020
Resolution: Vessel provided pictures and statement demonstrating that excess items had been removed and the area was marked "No Storage."
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that th ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
A leak was observed through the overhead stuffing tube in the inboard aft corner of the low pressure CO2 room. Repair leak.
SOLAS 74a I/11.a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2020
Resolution: Vessel re-stuffed top of tube and painted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2020
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner.
The RTD cover plate on the main engine was missing. Provide cover.
SOLAS 74a II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 24 December 2020
Resolution: Vessel provided cover and provided pictures of installed RTD covers.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 31 August 2020
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with manufacturer specifications. The purate pump on the ballast water management system was reported inoperable. Vessel is prohibited from using the ballast water management system until pump is replaced and system is operating in accordance to manufacturer specifications.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2020
Resolution: Vessel provided objective evidence that technician attendance and ABS verified operation.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 26 August 2020
Resolved
Due to differences found between Oil Record Book and sounding logs, the recorded data from the Oily Water Seperator's Oil Content Meter 107(49) recording device shall be provided to USCG Sector San Diego.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: OCM Memory Card removed from ship and is being analyzed by Sector San [name withheld] personnel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 August 2020
Resolved
Numerous piping systems were found to have degraded, missing, or improperly repaired lagging. Make proper repairs or replace lagging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 August 2020
Resolved
Numerous lube oil leaks were found on lube oil piping flanges throughout the engine room and hardware missing from one flange. Ensure proper gaskets and hardware are installed and repair leaks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 August 2020
Resolved
Generator bilges and generator filter cofferdams were found to excess oil accumulation. Remove all oil and properly clean.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 August 2020
Resolved
Purifier room bilges and all equipment containment within the purifier room were found to excess oil accumulation. Remove all oil and properly clean.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 August 2020
Resolved
The engine room door leading to deck six was found to have lose hardware and latching assembly, causing the marine inspector to temporarily be trapped in the engine room. Make proper repairs to door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Cleared by attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 August 2020
Resolved
The structural fire insulation above the #1 waste oil tank was found to be saturated in oil. Properly clean or replace insulation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Area was professionally cleaned. One small area (approx 6" x 4") of structural fiber was replaced. Several area of tape failure were replaced with CG approved tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 August 2020
Resolved
Three of the eight main engine cylinder exhaust pipes were found to missing lagging. Provide exhaust lagging for all bare piping leaving each cylinder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Cleared by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 August 2020
Resolved
Repair #3 and #2 generator fuel supply valve indicator switches, or provide documentation the switches are not required.
Action required: 705 - Other - as specified
Due 24 October 2020
Resolved 24 December 2020
Resolution: Vessel provided ABS preliminary report stating that valves with indicator switches were replaced with a new valves of equal size and rating. After
installation, the valve was operated and visually examined to the satisfaction of the attending surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 24 August 2020
Resolved
Repair steam leak on #2 waste oil tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 31 August 2020
Resolution: Vessel replaced gasket and demonstrated leak free while operating.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 August 2020
Resolved
Each generator was found to have different piping configurations on the HFO return line. Provide documentation showing approved alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 21 September 2020
Resolution: Received ABS Class survey report attesting to the correction and testing of HFO return lines.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 August 2020
Resolved
Each generator was found to have different piping configurations on engine sensors. Provide documentation showing approved alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 21 September 2020
Resolution: Received ABS Class survey report attesting to the correction of all three generator sensor piping systems.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2020
Resolved
Electrical control box found in purifier room was wrapped in plastic bags and zip tied in place. Make proper permanent repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 1 September 2020
Resolution: MSD Santa Barbara inspectors verified proper repairs were made.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 24 August 2020
Resolved
Prove proper operation of ballast water treatment system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 26 August 2020
Resolution: All alarms cleared and BWTS in ready mode.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 24 August 2020
Resolved
Boiler was found to have blanked off piping at top and loose bolts on casing. Tighten all bolts and provide documentation showing approved alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 3 September 2020
Resolution: Received drawings and piping specification sheet for boiler piping. Marine inspectors verified installation on 01SEP2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 August 2020
Resolved
Main engine flywheel tachometer magnetic sensor appears to recently installed and is mounted with zip-ties. Provide documentation showing approved alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 31 August 2020
Resolution: Vessel removed sensor and associated wiring. They explained that it was used for periodic PMS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 August 2020
Resolved
Main engine scavenging air piping has recently welded valves installed in piping. Provide documentation showing approved alterations.
Action required: 705 - Other - as specified
Due 24 October 2020
Resolved 18 November 2020
Resolution: Vessel rep provided ABS class report attesting to the verification / approval of main engine scav air valves.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 23 August 2020
Resolved
The multitude of deficiencies found by USCG Marine Inspectors from 22-24 AUG 2020 constitute a serious failure of the vessel's SMS. Failures include improper "MARPOL" tag logs and poor overall engine room maintenance/upkeep. Complete additional SMS external audit by Recognized Organization.
Action required: 30 - Ship detained
Resolved 27 August 2020
Resolution: SMS audit was conducted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 August 2020
Resolved
Complete annual servicing of portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2020
Resolution: Received portable fire extinguisher servicing report dated 28AUG2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 August 2020
Resolved
Repair broken smoke detector found on cargo deck 4 at Fr129(P) and heat detector hanging in purifier room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Tested by attending MI
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 August 2020
Resolved
Repair wasted fire hydrant (#161) valve stem leakage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 August 2020
Resolution: Vessel replaced entire valve assembly.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 August 2020
Resolved
Complete UT shots of deck plating around ballast tank #3 manhole covers. Provide report to Sector San Diego.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2020
Resolution: UT Shots found SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 August 2020
Resolved
Repair ballast tank #3 vent pipes (P/S) found with improper repairs and pinhole leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2020
Resolution: Vessel renewed ballast vent piping P/S.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2020
Resolved
Repair leak identified on steam line coil within Bilge Tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2020
Resolution: Repaired and witnessed testing by attending MI's/ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 August 2020
Resolved
Repair leaks identified on Fire/G.S. pump and main sea water inlet pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2020
Resolution: Pumps tested to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2020
Resolved
Repair excessive leak on condensate piping on stbd side above frame marked with sewage/exhaust gas ovbd.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2020
Resolution: Repaired to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 22 August 2020
Resolved
Replace oil soaked lagging on the high pressure fuel pump for cylinder #1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2020
Resolution: Repaired to satisfaction of attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 22 August 2020
Resolved
Clean the excessive water/debris/garbage in vicinity of sewage and exhaust gas drain overboard valves.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2020
Resolution: Cleaned to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2020
Resolved
#2 Generator jacking switch was found to have cardboard holding it into place. Make proper adjustments / repairs and functionally test interlock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Cleared by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2020
Resolved
Main engine air box salt water cooling piping was found to have sytho-glass temporary repairs. Make permanent repairs to wasted piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 3 September 2020
Resolution: Received drawings and piping specification sheet for main engine air cooling piping. Marine inspectors verified installation on 01SEP2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2020
Resolved
Main engine outer scavenging air piping was found to have 02 soft patches installed with rubber and hose clamps. Make permanent repairs to wasted piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 3 September 2020
Resolution: Received drawings and piping specification sheet for main engine scav air. Marine inspectors verified installation of replaced piping on 01SEP2020.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 17 August 2020
Resolved
Marine Sanitation Device was found to have modified piping on the suction side of the discharge pump. Restore piping to original or provide documentation showing approved alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 31 August 2020
Resolution: Vessel replaced missing elbow.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 17 August 2020
Resolved
Make permanent repairs to all cracked welds found on generator lube oil settling structural support members. Tank is located on the starboard side of the purifier room. Tank shall be certified "safe for hot-work" by a marine chemist prior to any welding or grinding. Repairs shall be completed as per repair proposal submitted on 27AUG2020 and to the satisfaction of attending and ABS surveyor.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 October 2020
Resolution: Vessel ground and rewelded supports to the satisfaction of attending ABS surveyors and CG MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 August 2020
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use.
During routine maintenance vessel's liferaft was accidentally deployed while enroute from Japan to San Diego, CA.
Prior to departure from San Diego, CA vessel shall have an operational liferaft onboard. SOLAS74(14)/III.20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 August 2019
Resolved
Life boat failed to launch properly from the stowed position. Remote brake release cable was improperly rigged, and also unable to recover fully without override of the limit switch. Boat is limited to only 1 use in case of actual abandon ship, until dry dock, when OEM can fully repair and properly test davit and falls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 November 2019
Resolved 4 December 2019
Resolution: Corrected, witnessed by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 August 2019
Resolved
Lagging on MDE falling apart from damage. Must be temp repaired prior to depart next port and make permanent replace/repair prior to completion of dry dock.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 4 December 2019
Resolution: Corrected, witnessed by ABS.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 16 August 2019
Resolved
SOLAS training manual found to not have required training items, specifically SCBA use, which was discovered when cross-referencing Confined Space Entry procedures to the training. Provide a CAR to Class, identifying missing training and procedures for SCBA as well as proper references for Confined Space Entry.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 16 September 2019
Resolution: Received an email from ABS surveyor with the CAR presented by the company which meets the items listed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 August 2019
Resolved
Various pressure cylinders found throughout vessel not properly secured. Cylinders to be properly secured or removed from vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 4 December 2019
Resolution: Corrected, witnessed by ABS.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 August 2019
Resolved
Found makeshift cooling buckets in life boats for engine testing. Buckets rigged for testing following loss of impellers on each boat. Buckets were removed.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 16 August 2019
Resolved 16 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 August 2019
Resolved
Loose wires/cables hanging down unsupported in the passageway from house to elevator. Crew corrected.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 August 2019
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 16 August 2019
Resolved
During testing/service of LP CO2, discharge horn did not sound in 3 of 5 zones. Tech rep investigated, repaired, and tested all zones, SAT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2019
Resolved 16 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 January 2019
Resolved
All ships 300 Gross tonnage and upwards engaged on international voyages shall be fitted with an automatic identification system (AIS)
AIS shall provide automatically to appropriately equipped shore stations, other ships and aircraft information including the ships identity, type, position, course, speed, navigational status and other safety related information. Vessel shall restore AIS to full operation prior to departing Antwerp, Belgium by means of a certified technician and provide report to US COAST GUARD ACTIVITIES EUROPE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2019
Resolved 25 January 2019
Resolution: Recieved technian report attesting to repaired AIS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2018
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. Identified (12) port side fire stations on decks 1-3 that were unable to supply water. Vessel shall ensure all stations are ready for use.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 November 2018
Resolved 7 November 2018
Resolution: Witnessed satisfactory test of fire main on port side from cargo deck 03.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 5 November 2018
Resolved
The International Oil Pollution Prevention Certificate shall be drawn up in the form corresponding to the model given in appendix II to this Annex and shall be in at least English, French of Spanish. The current IOPP Form A, table 3.1 lists the No.1 Waste Oil Tank twice and omits the No. 2 Waste Oil Tank. Additionally, the identification of the 'Bilge Separation Tank' listed under table 3.3 is unknown by the ship's crew and is not reflected in any ORB records. MARPOL I/9
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 November 2018
Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. No preventative maintenance plan or testing records were available for the fire main system. Company is required to complete and provide the results of an internal ISM audit regarding the development of maintenance, testing, and record keeping for the fire main system. 74 SOLAS 2014 Cons. IX/5, ISM Code Part A 10.3, ISM Code Resolution A.1071(28) 4.7.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 7 December 2018
Resolution: Received report of audit from the company and a copy of the new maintenance item; report attached to documents.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2018
Resolved
The Oil Record Book Pt I shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship: ballasting or cleaning of oil fuel tanks; discharge of dirty ballast or cleaning water from oil fuel tanks; collection and disposal of oil residues (sludge); discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces; and bunkering of fuel or bulk lubricating oil. Any failure of the oil filtering equipment shall be recorded in the Oil Record Book Pt I. A review of the ORB from 04Aug - 5Nov revealed 21 tank levels errors (ROB entries), 7 omitted weekly tank sounding entries, and numerous formatting errors. A new OCM was installed on November 4th, 2018 after the failure of the previously installed OCM; no ORB record was created. MARPOL I/17.2 &17.5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 November 2018
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use; and fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. The fire main pressure gauge readout in Engine Room Control is not accurate in comparison to the local pump gauge and needs to be replaced. 74SOLAS(14)II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 November 2018
Resolved
An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment under all practical conditions. The forward starboard E/R bilge suction strainer is not attached and therefore may not operate as designed if clogged with debris. 74SOLAS(04)II-1/21.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 7 November 2018
Resolution: Crew installed strainer
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 5 November 2018
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. For this purpose, the following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Access to the vertical escape ladder from Engine Room Control (behind the switchboard) is cluttered; remove obstacles for a clear escape route. 74SOLAS(14)II-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 7 November 2018
Resolution: Clutter removed from escape ladder.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 5 November 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship is all respects will remain fit to proceed to sea without danger to the ship or persons on board. The steering gear has excessive leaks which are causing a slipping hazard to persons onboard and may eventually affect the safe operation of the equipment; clean hydraulic oil leaks and monitor future leaks. 74SOLAS(14)I/11.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 7 November 2018
Resolution: Verified proper clean up of oil from space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 November 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship is all respects will remain fit to proceed to sea without danger to the ship or persons on board. The pneumatic line to the Engine Local control start air pressure gauge is crimped, likely affecting the accuracy of the gauge; renew the pneumatic gauge line. 74SOLAS(14)I/11.1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2018
Resolved 7 November 2018
Resolution: Verified install of new pneumatic line.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2018
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Three ventilation exhausts from the following locations found holed on the trunk and preventing their function: pantry exhaust, No. 1 sanitary exhaust, and No. 1 galley exhaust. Affect permanent repairs to holed exhausts.
SOLAS (97 Cons) II-2/17.9
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2018
Resolved
Where "A" class divisions are penetrated for the purpose of electrical cables, pipes, trunks ducts, etc, arrangements shall be made to ensure that the fire resistance is not impaired. Electrical wires penetrating port side bridge wing door, which is classified as an "A" class boundary, is not properly sealed to meet structural fire protection standards. Install proper fire protection to meet "A" class boundary standards.
SOLAS (97 Cons) II-2/18.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 7 November 2018
Resolution: Verified installation of proper structrual fire protection in cable transit.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 November 2018
Resolved
Satisfactory means (in the form of guard rails, lifelines…) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and all other parts used in the necessary work of the ship. First inboard stanchion leading up to the embarkation platform for port life boat holed and wasted. Affect permanent repairs to stanchion.
ICLL ANN I/25.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 5 November 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Steering console on bridge and speed log has several damaged indicator buttons making their function unreadable. Repair damaged indicator buttons.
SOLAS (14 Cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2018
Resolved 9 November 2018
Resolution: ABS accepted through report SF3581378
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 November 2018
Resolved
All items of lifeboat equipment shall be secured within the lifeboat by lashings, storage lockers or compartments, storage in brackets or similar mounting arrangements or other suitable means. Fire extinguisher in port lifeboat was lying on the deck. Properly mount portable fire extinguisher.
SOLAS (97 Cons) III/8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 7 November 2018
Resolution: Verified proper stowage of fire extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Two lifebuoys on either side of the stern main deck were permanently secured to the rail with line preventing immediate use. Remove line from rail for both lifebuoys.
SOLAS (97 Cons) III/19.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 November 2018
Resolved 7 November 2018
Resolution: Verified removal of tie downs on lifebuoys.
Fire Fighting › Fire Main › Condition
Issued 25 April 2018
Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Vessel discovered two areas of wastage on the fire main piping on deck; on 90 degree elbow aft of galley, fire main run athwartship to NO.1 Engine Room exhaust Fan. Both areas of wastage were temporarily patched using epoxy putty and fiber glass wrap prior to USCG attendance. Crop and renew wasted sections of fire main piping prior to departing Jacksonville to the satisfaction of the attending Marine Inspector or Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2018
Resolved 29 April 2018
Resolution: TESTED FIRE MAIN 7 BAR NO LEAKS
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 April 2018
Resolved
Any required fixed fire detection and fire alarm system shall be capable of immediate operation at all times. Vessel has four registered faults in the fire detection system for the NO. 5 cargo deck. Repair or renew faulty smoke detectors on NO.5 cargo deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2018
Resolved 29 April 2018
Resolution: TESTED 02 SMOKE ALARMS FOUND SAT
Fire Fighting › Fire Pumps › Casing
Issued 27 July 2017
Resolved
Holes was identified in the emergency fire pump casing. Replacement was placed ordered but did not arrive on time. Temp repair was completed to the existing FP and tested satisfactory. Make permanent repair to sat of the attending [name withheld] 1/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 3 January 2018
Resolution: Fire pump was replaced in kind. operational test witnessed by USCG inspectors and Class.
Engineering › Compressed Air System (start air) › Valve
Issued 27 July 2017
Resolved
Means shall be provided where practicable to protect against such excessive pressure. It was observed NO1 and NO2 pressure vessels are pressed beyond the design pressure under normal operation. Complete hydrostatic test to satisfaction of the attending [name withheld] 1997 amd Regulation 27(2)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 January 2018
Resolved 17 April 2018
Resolution: Cleared by class
Engineering › Compressed Air System (start air) › Valve
Issued 27 July 2017
Resolved
Means shall be provided where practicable to protect against such excessive pressure. It was observed pressure vessels are not protected against over filling. Install safety relief device to ensure pressure vessels are protected against overfilling. SOLAS 1997 AMD Regulation 27 (2).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 January 2018
Resolved 20 April 2018
Resolution: Cleared by calss
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 28 April 2017
Resolved
Vessel master failed to properly submit an Advanced Notice of Arrival prior to the appropriate timeframe for entry into the Port of Jacksonville.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 28 April 2017
Resolution: Vessel master educated on proper procedures and to follow up when unsure if submission was successfully received. Corrected on the spot.
Accommodation/Occupational Safety › Ventilation › General
Issued 9 December 2016
Resolved
Stbd Fan #B-1-R has a wasted knife-edge and will not seal properly. Repair knife-edge to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 January 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Size
Issued 9 December 2016
Resolved
Lifebuoy located on the stbd bridgewing does not meet the 4kg requirement. Replace lifebuoy with a 4kg CG approved lifebuoy.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 January 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Ventilation › General
Issued 9 December 2016
Resolved
CO2 space ventilation ducting was wasted and restricting adequate exhaust flow from space. Repair ducting to the satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 13 December 2016
Resolution: Vessel crew corrected to the satisfaction of the CG MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 December 2016
Resolved
Lifebuoy self-igniting light did not have the proper batteries, i.e. springs vs. studs, to ensure proper electrical connection. Replace all batteries with proper batteries on all affected lights.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 8 January 2017
Resolution: Corrected.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 9 December 2016
Resolved
Structural fire protection throughout vessel was missing.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 13 December 2016
Resolution: Vessel crew corrected to the satisfaction of the CG MI.
Engineering › Fuel Oil Service System › Piping
Issued 9 December 2016
Resolved
Fuel lagging was missing in numerous locations throughout engineroom.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 13 December 2016
Resolution: Vessel crew corrected to the satisfaction of the CG MI.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 December 2016
Resolved
Excessive waste oil was discovered behind waste oil tank presenting a fire hazard. Remove all excessive oil waste from behind waste oil tank.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 13 December 2016
Resolution: Vessel crew corrected to the satisfaction of the CG MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 December 2016
Resolved
Wrench for manual actuation of LP CO2 was missing.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 December 2016
Resolution: Corrected on the spot.
Construction/Loadline › Structures › Scuttle
Issued 9 December 2016
Resolved
Port escape hatch to deck 12 was stuck in the closed position, i.e. dogs were seized.
Action required: 705 - Other - as specified
Due 9 January 2017
Resolved 9 December 2016
Resolution: Corrected on the spot.
Fire Fighting › Fire Main › Valves
Issued 15 March 2016
Resolved
The vessel may not conduct repairs to the vessel fire fighting piping system while the vessel is underway, that would require any modifications to the fire fighting system to remove sections of piping for repair.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 15 March 2016
Resolution: master acknowledged receipt.