Records from 2000 to 2026. Most recent: inspection, 25 June 2026.
Documentation record
Registered dimensions (L × B × D)144.0 ft × 50.0 ft × 8.0 ft
Registered tonnagegross 440 / net 132
ITC dimensions (L × B × D)144.0 ft × 50.0 ft × 8.0 ft
ITC tonnagegross 440 / net 132
BuilderMOBRO MARINE INC · GREEN COVE SPRINGS, FL, UNITED STATES · built 2000
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 June 2026 · expires 30 June 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it440 - Convention (Subpart B), Gross Ton
132 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
25 June 2026
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8413740
20 October 2025
Internal Structural Exam · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8259855
12 July 2024
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7956807
11 July 2024
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7956202
1 August 2023
MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex VI Survey · COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7745981
9 November 2022
Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7587696
5 August 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7525408
23 February 2022
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7397489
7 May 2020
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6951256
3 April 2019
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6654104
19 December 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6600054
5 March 2018
MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6370315
18 May 2017
Hull Examination · COI Inspection · MARPOL Annex VI Survey · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6149026
7 March 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4268632
6 March 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4264248
8 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3722246
25 January 2007
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2861797
16 December 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1719762
27 June 2001
Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1373516
3 March 2000
COI Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1451515
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 20 October 2025
Resolved
The surveyor shall examine on all vessels the items, etc., listed in this paragraph to determine if in satisfactory condition and meeting applicable requirements in this subchapter.
Cargo hatch coamings, covers, beams and supports, gaskets, clamps, locking bars, tarpaulins, battens, cleats and wedges of hatches on exposed freeboard, quarter and superstructure decks, and elsewhere as may be necessary. Hatch cover gaskets are wasted. Replace.
46 CFR 42.09-25
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2025
Resolution: gaskets renewed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 20 October 2025
Resolved
02 Deck support bars were broken. Reweld.
46 CFR 42.09-25
Action required: 10 - Deficiency Rectified
Resolved 20 October 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 October 2025
Resolved
Hatch securing devices were missing on 03 hatches
46 CFR 42.09-25
Action required: 10 - Deficiency Rectified
Resolved 20 October 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 October 2025
Resolved
Each navigation light system must meet the following: Be installed so that its location and its angle of visibility meet the applicable navigation rules. Stbd Navigation light extinguished. Replace.
Action required: 10 - Deficiency Rectified
Resolved 20 October 2025