Records from 2000 to 2016. Most recent: inspection, 13 July 2016.
Inspection history · 25
13 July 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5939792
24 February 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5821684
20 February 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5818920
18 February 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5817561
15 February 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5815230
12 February 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5814496
9 October 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4997033
26 September 2011
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4154729
15 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3850269
3 September 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3841263
24 January 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3667449
22 January 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3667994
29 July 2009
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3549533
29 July 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3550698
17 February 2009
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3419207
19 January 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3395595
4 September 2004
Random ISPS/MTSA/PSC
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2186176
22 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2172668
6 August 2003
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1868867
27 April 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1781950
3 April 2002
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1600544
1 April 2002
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1600729
12 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290939
6 August 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 280434
8 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 277529
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 February 2016
No resolution recorded
The shafts in the generators protrude roughly one inch through the casing without any guards to protect personnel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 March 2016 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Gyro Compass
Issued 26 September 2011
Resolved
Vessel's gyro compass is reading off by 8 degrees. Vessel was issued an I/B LOD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2011
Resolution: Gyro compass was repaired and it is fully operational.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 3 September 2010
Resolved
Audible alarm for fixed fire detection in engine room is not operational (visual alarm and general alarm is operational).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 15 September 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 September 2010
Resolved
Generator #3 has soft patch on salt water cooling line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 15 September 2010
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 3 September 2010
Resolved
Main diesel engine has small leak in (heated heavy fuel oil) supply piping.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 September 2010
Resolved 15 September 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 3 September 2010
Resolved
Lube oil gauge on generator #2 is not functioning.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 15 September 2010
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 3 September 2010
Resolved
The following fire doors did not close:
1. Fire door IWO portside tween cargo deck entrance IWO steering gear.
2. E gen entrance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 15 September 2010
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 3 September 2010
Resolved
E gen starting battery voltage indicator is not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 15 September 2010
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2009
Resolved
Vessel sustained damage located on stern, starboard side, corner transition (ballast tank 19). Affect temporary or permanent repairs to the satisfaction of Class, prior to departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2009
Resolution: 31JUL09 received fax from Nordana Chartering on behalf of M/V PATRIA attesting to the (1) deficiency corrected. (Document scanned titled "PATRIA Form B").
Construction/Loadline › Hull › Weld
Issued 19 January 2009
Resolved
There is a pinhole leak where the bulbous bow meets the forward peak tank.
ILL 2005 Annex I/1.3
Rectify deficiencies in 30days to the satisfaction of class.
Action required: 705 - Other - as specified
Due 19 February 2009
Resolved 11 February 2009
Resolution: Repair has been carried out by Company Gulf Copper of Port Arthur, TX. Surveyor on site approved the procedures and was present during the repairs and final tests.
Lifesaving › Launching Appliances › Falls
Issued 19 January 2009
Resolved
The starboard lifeboat davit limit switches did not function properly.
LSA VI/6.1.2.7
Due 19 January 2009
Resolved 19 January 2009
Resolution: Witnessed satisfactory operation of the davit limit switches.
Lifesaving › Lifeboat › Propeller Shaft
Issued 19 January 2009
Resolved
The transmission linkage was inoperative on the port lifeboat
LSA IV/4.4.6.i
Due 19 January 2009
Resolved 19 January 2009
Resolution: Witnessed satisfactory operation of the port lifeboat engine/transmission ahead and reverse.
Lifesaving › Inflatable Liferafts › Float Free
Issued 22 August 2004
Resolved
Flag administration or Classification society acting upon their behalf, to review float free arangement of port and starboard liferafts. In regard to the possibility of raft entanglement in upper deck should the ship sink or capsize. Report findings to USCG Sector Miami before returning to US after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2005
Resolution: Classification society verified float free arangement on port and starboard liferafts during last annual inspection.
Communications › Internal Communications System › Sound-powered Telephone
Issued 27 April 2003
Resolved
Ships internal communications device located in the steering room is in operative. (SOLAS 74/78 Ch. 5/12(f)) Repair steering room communication device and test to the satisfaction of the safety construction certificate issuing athority, prior to 27MAY03 or next U.S. Port.
Action required: 705 - Other - as specified
Due 27 May 2003
Resolved 22 August 2004
Accommodation/Occupational Safety
Issued 8 May 2000
Resolved
PROVIDE PROOF OF USCG OR IMO APPROVAL OF MARINE SANITAION DEVICE IN ACCORDANCE WITH 33 CFR 159.7 PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000