Records from 1981 to 2006. Most recent: inspection, 11 August 2006.
Documentation record
Registered dimensions (L × B × D)220.0 ft × 52.0 ft × 12.0 ft
Registered tonnagegross 1,362 / net 1,362
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAVONDALE SHIPYARDS INC · AVONDALE, LA, UNITED STATES · built 1962
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itFreight Ship
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1362 - Regulatory (Subpart C or D), Net Ton
1362 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
11 August 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2751181
21 January 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1098437
19 July 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1087602
22 November 1995
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363422
31 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758179
29 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 191288
21 July 1995
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412845
16 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 98396
10 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463862
3 February 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407263
10 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 521097
22 December 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826491
2 December 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 960693
30 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 80327
30 June 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505692
23 January 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 953238
16 November 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924437
12 March 1990
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239192
15 November 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217300
18 November 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893050
14 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 444667
26 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322097
8 December 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002445
26 November 1986
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334265
12 September 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008036
14 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288467
16 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970825
12 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273838
12 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970256
Engineering
Issued 21 July 1995
Resolved
Repair thermal fluid heater house exterior visual (blue light) alarm.
Condition: Unknown
Due 1 August 1995
Resolved 7 August 1995
Engineering
Issued 21 July 1995
Resolved
Repair thermal fluid heater safety shutdown panel audible alarm.
Condition: Unknown
Due 1 August 1995
Resolved 7 August 1995
Electrical
Issued 21 July 1995
Resolved
Replace all temporary nylon wire ties holding/supporting electrical cable with steel banding per IEEE45.
Condition: Unknown
Due 1 August 1995
Resolved 7 August 1995
Electrical
Issued 10 November 1994
Resolved
Prove proper operation of generator emergency shutdown in the presence of CG Marine Inspector.
Condition: Unknown
Due 1 December 1994
Resolved 30 November 1994
Lifesaving
Issued 2 December 1992
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THERMAL FLUID HEATER FAILURE WARNING LIGHT.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Fire Fighting
Issued 12 September 1986
Resolved
PERFORM ANNUAL SERVICING FOR PORTABLE FIRE EXTINGUISHERS AND FIXED CO2 SYSTEM FOR THERMAL FLUID HEATER.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Fire Fighting
Issued 12 September 1986
Resolved
INSTALL BREAKER BARS FOR TWO (2) REMOTE PULL CABLES ON CO2 SYSTEM.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Deck/Cargo
Issued 12 September 1986
Resolved
REMOVE OIL FROM UNDERNEATH ONE (1) CARGO PUMP ENGINE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Electrical
Issued 12 September 1986
Resolved
REMOVE OIL FROM UNDERNEATH GENERATOR IN THERMAL FLUID HEATER SPACE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Deck/Cargo
Issued 12 September 1986
Resolved
PERFORM ANNUAL HYDROTEST OF CARGO DISCHARGE PIPING.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Construction/Loadline
Issued 12 September 1986
Resolved
GAS FREE TWO (2) CARGO TANKS AND HOPPER SPACE SURROUNDING CARGO TANKS FOR INTERNAL AND EXTERNAL EXAMINATION.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Construction/Loadline
Issued 12 September 1986
Resolved
FREE UP DOGS ON ALL HATCH COVERS. PROVIDE DOGS WHERE MISSING.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Construction/Loadline
Issued 12 September 1986
Resolved
REPAINT NAME AND HOMEPORT ON STERN OF VESSEL.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Deck/Cargo
Issued 12 September 1986
Resolved
LABEL THERMAL FLUID HEATER REMOTE CUTOUT SWITCH.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Electrical
Issued 12 September 1986
Resolved
LABEL GENERATOR REMOTE SHUTDOWN PULL CABLE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Fire Fighting
Issued 12 September 1986
Resolved
LBEL ONE (1) C02 REMOTE PULL CABLE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Deck/Cargo
Issued 12 September 1986
Resolved
REMOVE OIL FROM UNDERNEATH THERMAL FLUID HEATER SPACE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986