MAURY USCG vessel records
← All vessels

INNISFREE

Built
1980
Last inspected
18 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 July 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB5713
Flag
UNITED STATES
Maury page id
psix-51149

Documentation record

Registered dimensions (L × B × D)71.9 ft × 15.6 ft × 5.7 ft
Registered tonnagegross 35 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 45 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 45

18 July 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8441253
6 July 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8430987
4 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8390743
30 May 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8384322
9 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8180152
10 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8155410
24 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8069425
4 October 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8014333
15 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7958536
15 April 2024 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7897263
1 April 2024 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888038
25 July 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7750937
23 May 2023 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7694572
21 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7513041
20 April 2022 Drydock Exam · Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7434878
20 April 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7434917
10 September 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378233
9 September 2021 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7308982
11 August 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7291262
10 August 2021 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283443
22 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7268070
21 July 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7301354
21 June 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7233514
5 August 2020 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7025070
19 December 2019 Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6877154
29 November 2019 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6864621
25 November 2019 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6862134
7 November 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6851501
27 October 2019 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6843440
12 October 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6834702
4 October 2019 Plan Review "T" Boat · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6829540
29 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6808866
29 August 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6847182
28 August 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6797413
16 July 2019 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6776040
10 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6746075
21 May 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6690086
20 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6629115
31 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6572159
20 June 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6455320
10 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6204567
13 April 2017 Internal Structural Exam · Administrative Inspection · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6153628
2 November 2016 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6034179
31 May 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5902192
18 April 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5858013

Deficiency record · 40

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2026 Resolved
Bilge suctions shall be fitted with suitable strainers having an open area no less than three times the area of the bilge piping. The strainer in way of the starboard suction in the tank room is wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2026 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The brackets in way of the CO2 fire extinguishers in the engine room and main deck concession area are not the proper brackets to maintain USCG approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 6 July 2026
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 June 2026 Resolved
Ecah vessel that operates beyond three miles from the coastline must have on board a 406MHz EPIRB. The EPIRB was inadvertantley activated and subsequent tests failed. Vessel is restricted to three miles from the coastline.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025 Resolved
An adult lifejacket is required for each person carried onboard a vessel. The COI allows carriage of 113 total persons. Only 104 adult lifejackets are provided. Provide an additional 9 adult lifejackets. The vessel is limited to the carriage of 104 total persons pending resolution of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 July 2025
Resolution: O/O provide receipt for purchase of nine new Type I adult life jackets and pictures showing proper marking of the same.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
Each fire hose must be provided with a nozzle. The nozzles for the port and starboard fire stations are missing "o" rings and retention chains. Repair or replace the same. (New nozzles must meet 46 CFR 162.027).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 11 July 2025
Resolution: O/O provide picture of two new CG approved nozzles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
All observed unsafe practices must be corrected. The port and starboard fire stations are leaking at the valve stem. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 11 July 2025
Resolution: O/O provide video of proper operatio of fire hydrants.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025 Resolved
Vessels operating on a Great Lakes route more than 20 nautical miles from shore must provide lifejacket lights on each required lifejacket. None of the lifejackets are provided with lights. Provide lifejacket lights or request a change in routes and conditions limiting the vessel to within 20 nautical miles from a harbor of safe refuge year round. Vessel is restricted to within 20 nautical miles from a harbor of safe refuge pending completion of the above.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 July 2025
Resolution: Vessel owner decided to reduct the vessel's route to less than 20 nautical miles from a harbor of safe refuge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
04 deck weather flush hatches are missing devices to prevent hatch loss. Replace/install hatch devices that will prevent their loss.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting installation of captive cables for weather deck hatches.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2022 Resolved
Emergency escape from engine space needs labeling from inside of space, "Emergency Exit, Keep Clear". 46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting required signage posted in the engine compartment.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
Starboard side piolet house window is cracked. Repair/replace starboard side window. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting replacement of starboard side pilot house window.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2021 Resolved
Vessel has experienced a loss of power with A/C generator. Vessel is not able to restart generator or put back online. Make repairs to generator, submit technical after action report with failure cause and rectification process. When repairs are complete, notify local OCMI for visual inspection and witness testing prior to the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 12 August 2021
Resolution: Cummins Techs repaired genset, conducted 90 min full load power trial, left watching properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 June 2021 Resolved
Vessels EPRIB battery is expired. Replace EPRIB and provide proof that new unit is registered with NOAA, Route is restricted to not more than 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2021 Resolved
STBD Side, Third stanchion aft on overhead canopy has cracked weld. Conduct repair to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
03 child lifejackets were not serviceable and destroyed. Vessel is required to have 12 child lifejackets on board. Vessel has 10 good child jackets on board and may only carry 10 children as passengers until full child jacket requirement is met to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 21 August 2020
Resolution: 03 child life jackets replaced to satisfaction of Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 August 2020 Resolved
Port side of galley area #1 window has a crack. Repair/replace cracked glass to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 21 August 2020
Resolution: Broken glass replaced to the satisfaction of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 November 2019 Resolved
Generator shutdown, received no error codes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2019 Resolved
Vessels of 12 meters or more in length shall be provided with a whistle and a bell. Vessel's installed ship service whistle is inoperative. Repair/replace installed ship service whistle to the satisfaction of attending Marine Inspector. Vessel may utilized West Marine signal horn can, with provided extra crew, for the remaining voyages scheduled on their protected routes for the date of 25NOV2019, and while vessel visibility is clear. Further review and authorization will be needed for any other voyages beyond 25NOV2019 while installed ship service whistle is inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 26 November 2019
Resolution: Electric motor was renewed compressor tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 October 2019 Resolved
Vessel reported steering was not functioning port or starboard. Determine cause of steering malfunction correct prove proper operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2019
Resolved 28 October 2019
Resolution: See info in documents for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2019 Resolved
Remove electrical extension cord from power strip being used in pilot house by PA System to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Electrical extension cord was removed as permanent wiring to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
All three life rings onboard are missing retro material. Install retro material to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Vessel provided evidence of replaced retro material on life rings to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
Life rings with throw lines have 50' of line. Throw lines must have at least 60' of line. Install proper throw line lenghts on life rings with throw lines to satisfaction of attending Marine Inspectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Vessel provided evidence of installing 70' throw lines on life rings to satisfaction of Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2019 Resolved
Engine space is missing portable battery light. Install light to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Portable battery light near machinery space entry has been installed to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 July 2019 Resolved
Fire pump inlet, outlet, and bilge system cross connect valves are hard to actuate and require maintenance. Perform maintenance on the three (3) valves in order to operate smoothly to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Marine Inspector accepted photograph/statement of the 3 mentioned cross connect valves for fire pump being removed and replaced and operating as necessary.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 July 2019 Resolved
Oil present on deck below oil strip pump. Remove oil to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
Resolution: Oil was removed from deck to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2019 Resolved
A new shaft seal cooling system was installed on vessel. Provide proof of MSC approved plans/drawings of new modification or restore system to it's originally approved status to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 20 December 2019
Resolution: MSU CHICAGO examined installation. It has been present for 2 years and operating with no reported issues. Chicago OCMI will review/approve alterations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2019 Resolved
Properly label and number all life jacket stowage spaces throughout vessel to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Life jacket stowage areas have been labled and numbered to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 July 2019 Resolved
Port side engine room vent damper is missing hardware to keep damper closed. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Marine Inspector accepted photograph/statement of missing hardware replaced in order to keep damper in closed position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2019 Resolved
Received report of vibration issue on the rear shaft area vessel. Vessel will be taken out of water at Sunset Bay Marina. Once issue is found and repairs have been made, vessel to be attended and inspected to satisfaction of attending marine inspector. Vessel not permitted to carry passengers until cleared by USCG. 46 CFR 176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2019
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 June 2017 Resolved
Fire extinguishers have not been serviced within the last 12 months. To be serviced by a qualified third party.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Reliable Fire and safety came out to service all fire extinguisher's
Stability › Intact Stability (when using lifting gear) › General
Issued 1 June 2017 Resolved
Vessel has modified its permanent ballast arrangement. New ballast arrangement is to be evaluated by a certified party for changes in VCG and LCG to the vessel's light ship characteristics. Calcs and determinations are to be forwarded to CG MSC for evaluation and approval. A new stability letter will need to be issued to reflect changes. Changes are minor vessel may operate until 1JUL17.
Due 1 July 2017
Resolved 14 July 2017
Resolution: MSC approved changes and issued new stability letter
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 June 2017 Resolved
Drill & training logs were not on board for verification. Vessel to provide proof of drill and training logs to MSU Chicago for verification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Log book was provided to show proof of drills and training have been conducted as required
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 June 2017 Resolved
Due to significant steel work completed and the addition of metal ballast the compass is to have it's deviation tables redone.
Due 8 June 2017
Resolved 14 July 2017
Resolution: new deviation table was provided
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 1 June 2017 Resolved
Hydrostatic release units for the IBAs are expired and must be replaced with new approved units.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: New Hydrostatic release was installed
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 June 2017 Resolved
The sewage waste line in the engine room has a significant leak. Make permanent repairs and prove leak free operation.
Due 8 June 2017
Resolved 1 June 2017
Resolution: sewage piping was repaired and verified to be leak free.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 June 2017 Resolved
Water tight cable penetrations in the fwd engineroom bulkhead are not water tight. Make all penetrations water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2017
Resolution: Pentrations were made watertight and verified by the attending MI.
Electrical › Electric Supply System (service) › Cable
Issued 1 June 2017 Resolved
There is a dead ended wire in the aft deck house overhead on the stbd side. Remove the cable or properly terminate the cable in a fixed junction box.
Due 8 June 2017
Resolved 14 July 2017
Resolution: Vessel properly terminated the cable in a junction box above the bar
Electrical › Electric Supply System (service) › Cable
Issued 1 June 2017 Resolved
An electrical cable under the stbd fwd bench on the weather deck is not properly supported. Support the cable with banding every 24".
Due 8 June 2017
Resolved 14 July 2017
Resolution: Properly installed metal cable supports every 24 inches
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2016 Resolved
Light fixture broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Corrected prior to completion of inspection.
Communications › Radio Communications › EPIRB
Issued 18 April 2016 Resolved
EPIRB Hydrostatic Release Expired
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Replaced with identical release prior to completion of inspction.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2016 Resolved
3 Adult and 1 Child Lifejacket unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Replaced 3 adult and 1 childe lifejacket with proper identification markings prior to completion of inspection.

Recorded names · 1

LADY FENWICK (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.