INNISFREE

INNISFREE is a 1980 passenger vessel (inspected). The Coast Guard has recorded 115 inspections since 1984, most recently in July 2026, along with 136 deficiencies, 2 operational controls and 11 casualty investigations between 2003 and 2021.

Records from 1984 to 2026. Most recent: inspection, 18 July 2026.

Built
1980
Last inspected
18 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5713
Flag
UNITED STATES
366912650
Maury page id
psix-51149

Inspections, by type

…with no type recorded15
Years with a record 41 calendar years (1984–2026)
The 115 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.9 ft × 15.6 ft × 5.7 ft
Registered tonnagegross 35 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB5713MMSI 366912650 · active · compulsorily equipped · granted 20 October 2023, expires 11 November 2033
WSP3083MMSI not assigned · expired · compulsorily equipped · granted 29 November 1994, cancelled 27 November 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CUYAHOGA Freight Ship · MISLE 42103 · 25 May 2003 · activity 1808663

Inspection history · 115

18 July 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8441253
6 July 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8430987
4 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8390743
30 May 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8384322
9 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8180152
10 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8155410
24 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8069425
4 October 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8014333
15 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7958536
15 April 2024 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7897263
1 April 2024 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888038
25 July 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7750937
23 May 2023 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7694572
21 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7513041
20 April 2022 Drydock Exam · Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7434878
20 April 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7434917
10 September 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378233
9 September 2021 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7308982
11 August 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7291262
10 August 2021 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7283443
22 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7268070
21 July 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7301354
21 June 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7233514
5 August 2020 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7025070
19 December 2019 Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6877154
29 November 2019 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6864621
25 November 2019 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6862134
7 November 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6851501
27 October 2019 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6843440
12 October 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6834702
4 October 2019 Plan Review "T" Boat · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6829540
29 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6808866
29 August 2019 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6847182
28 August 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6797413
16 July 2019 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6776040
10 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6746075
21 May 2019 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6690086
20 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6629115
31 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6572159
20 June 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6455320
10 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6204567
13 April 2017 Internal Structural Exam · Administrative Inspection · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6153628
2 November 2016 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6034179
31 May 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5902192
18 April 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5858013
19 May 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4865063
15 June 2012 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4344660
25 August 2011 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4129686
20 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4123724
9 November 2010 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3888018
28 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3880037
28 October 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3883157
28 October 2010 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3885569
3 April 2009 Deadweight Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3447049
13 November 2008 Plan Review "T" Boat · Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3365866
9 October 2008 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337908
4 September 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3317450
14 July 2008 Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3267551
7 July 2008 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3260244
20 June 2008 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3242224
4 June 2008 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3226975
4 April 2008 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3178831
2 November 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3091820
9 October 2007 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3075770
18 October 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2804710
12 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2797786
3 September 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2792681
22 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2498540
16 May 2005 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2356694
6 May 2005 Administrative Inspection · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2350636
31 January 2005 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2290250
24 May 2004 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2076600
6 November 2003 Administrative Inspection · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1942551
7 July 2003 Examination of Repairs · Hull Examination · Inclining Experiment
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1838654
25 May 2003 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1808663
20 November 2002 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1709088
30 September 2002 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1682212
5 February 2002 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1482603
25 October 2001 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1462997
5 July 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1068031
26 October 2000 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1468171
23 May 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1430856
8 October 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1198424
5 October 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1456742
3 May 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 796984
14 October 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 802994
2 April 1998 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778002
22 October 1997 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1120940
6 May 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1104608
10 October 1996 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1106902
13 October 1995 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182987
9 March 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852985
9 March 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163600
13 October 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177008
31 January 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853996
14 October 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844708
15 October 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245470
15 October 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936110
12 March 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910305
17 October 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928715
28 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227573
26 October 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220165
17 October 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040953
30 September 1989 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005133
20 October 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197053
15 March 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016177
20 October 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324924
24 February 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016964
22 January 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011433
20 October 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326472
14 March 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999173
23 October 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300409
5 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291518
31 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291519
25 October 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1286858

Deficiency record · 136

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2026 Resolved
Bilge suctions shall be fitted with suitable strainers having an open area no less than three times the area of the bilge piping. The strainer in way of the starboard suction in the tank room is wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2026 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The brackets in way of the CO2 fire extinguishers in the engine room and main deck concession area are not the proper brackets to maintain USCG approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 6 July 2026
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 June 2026 Resolved
Ecah vessel that operates beyond three miles from the coastline must have on board a 406MHz EPIRB. The EPIRB was inadvertantley activated and subsequent tests failed. Vessel is restricted to three miles from the coastline.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025 Resolved
An adult lifejacket is required for each person carried onboard a vessel. The COI allows carriage of 113 total persons. Only 104 adult lifejackets are provided. Provide an additional 9 adult lifejackets. The vessel is limited to the carriage of 104 total persons pending resolution of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 July 2025
Resolution: O/O provide receipt for purchase of nine new Type I adult life jackets and pictures showing proper marking of the same.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
Each fire hose must be provided with a nozzle. The nozzles for the port and starboard fire stations are missing "o" rings and retention chains. Repair or replace the same. (New nozzles must meet 46 CFR 162.027).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 11 July 2025
Resolution: O/O provide picture of two new CG approved nozzles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2025 Resolved
All observed unsafe practices must be corrected. The port and starboard fire stations are leaking at the valve stem. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 11 July 2025
Resolution: O/O provide video of proper operatio of fire hydrants.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2025 Resolved
Vessels operating on a Great Lakes route more than 20 nautical miles from shore must provide lifejacket lights on each required lifejacket. None of the lifejackets are provided with lights. Provide lifejacket lights or request a change in routes and conditions limiting the vessel to within 20 nautical miles from a harbor of safe refuge year round. Vessel is restricted to within 20 nautical miles from a harbor of safe refuge pending completion of the above.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 July 2025
Resolution: Vessel owner decided to reduct the vessel's route to less than 20 nautical miles from a harbor of safe refuge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
04 deck weather flush hatches are missing devices to prevent hatch loss. Replace/install hatch devices that will prevent their loss.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting installation of captive cables for weather deck hatches.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2022 Resolved
Emergency escape from engine space needs labeling from inside of space, "Emergency Exit, Keep Clear". 46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting required signage posted in the engine compartment.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
Starboard side piolet house window is cracked. Repair/replace starboard side window. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Received photo documenting replacement of starboard side pilot house window.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2021 Resolved
Vessel has experienced a loss of power with A/C generator. Vessel is not able to restart generator or put back online. Make repairs to generator, submit technical after action report with failure cause and rectification process. When repairs are complete, notify local OCMI for visual inspection and witness testing prior to the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 12 August 2021
Resolution: Cummins Techs repaired genset, conducted 90 min full load power trial, left watching properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 June 2021 Resolved
Vessels EPRIB battery is expired. Replace EPRIB and provide proof that new unit is registered with NOAA, Route is restricted to not more than 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2021 Resolved
STBD Side, Third stanchion aft on overhead canopy has cracked weld. Conduct repair to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
03 child lifejackets were not serviceable and destroyed. Vessel is required to have 12 child lifejackets on board. Vessel has 10 good child jackets on board and may only carry 10 children as passengers until full child jacket requirement is met to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 21 August 2020
Resolution: 03 child life jackets replaced to satisfaction of Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 August 2020 Resolved
Port side of galley area #1 window has a crack. Repair/replace cracked glass to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 21 August 2020
Resolution: Broken glass replaced to the satisfaction of Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 November 2019 Resolved
Generator shutdown, received no error codes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2019 Resolved
Vessels of 12 meters or more in length shall be provided with a whistle and a bell. Vessel's installed ship service whistle is inoperative. Repair/replace installed ship service whistle to the satisfaction of attending Marine Inspector. Vessel may utilized West Marine signal horn can, with provided extra crew, for the remaining voyages scheduled on their protected routes for the date of 25NOV2019, and while vessel visibility is clear. Further review and authorization will be needed for any other voyages beyond 25NOV2019 while installed ship service whistle is inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2019
Resolved 26 November 2019
Resolution: Electric motor was renewed compressor tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 October 2019 Resolved
Vessel reported steering was not functioning port or starboard. Determine cause of steering malfunction correct prove proper operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2019
Resolved 28 October 2019
Resolution: See info in documents for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2019 Resolved
Remove electrical extension cord from power strip being used in pilot house by PA System to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Electrical extension cord was removed as permanent wiring to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
All three life rings onboard are missing retro material. Install retro material to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Vessel provided evidence of replaced retro material on life rings to satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2019 Resolved
Life rings with throw lines have 50' of line. Throw lines must have at least 60' of line. Install proper throw line lenghts on life rings with throw lines to satisfaction of attending Marine Inspectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Vessel provided evidence of installing 70' throw lines on life rings to satisfaction of Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2019 Resolved
Engine space is missing portable battery light. Install light to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Portable battery light near machinery space entry has been installed to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 July 2019 Resolved
Fire pump inlet, outlet, and bilge system cross connect valves are hard to actuate and require maintenance. Perform maintenance on the three (3) valves in order to operate smoothly to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Marine Inspector accepted photograph/statement of the 3 mentioned cross connect valves for fire pump being removed and replaced and operating as necessary.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 July 2019 Resolved
Oil present on deck below oil strip pump. Remove oil to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2019
Resolution: Oil was removed from deck to satisfaction of attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2019 Resolved
A new shaft seal cooling system was installed on vessel. Provide proof of MSC approved plans/drawings of new modification or restore system to it's originally approved status to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 20 December 2019
Resolution: MSU CHICAGO examined installation. It has been present for 2 years and operating with no reported issues. Chicago OCMI will review/approve alterations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 July 2019 Resolved
Properly label and number all life jacket stowage spaces throughout vessel to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Life jacket stowage areas have been labled and numbered to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 July 2019 Resolved
Port side engine room vent damper is missing hardware to keep damper closed. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 9 August 2019
Resolution: Marine Inspector accepted photograph/statement of missing hardware replaced in order to keep damper in closed position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2019 Resolved
Received report of vibration issue on the rear shaft area vessel. Vessel will be taken out of water at Sunset Bay Marina. Once issue is found and repairs have been made, vessel to be attended and inspected to satisfaction of attending marine inspector. Vessel not permitted to carry passengers until cleared by USCG. 46 CFR 176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2019
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 June 2017 Resolved
Fire extinguishers have not been serviced within the last 12 months. To be serviced by a qualified third party.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Reliable Fire and safety came out to service all fire extinguisher's
Stability › Intact Stability (when using lifting gear) › General
Issued 1 June 2017 Resolved
Vessel has modified its permanent ballast arrangement. New ballast arrangement is to be evaluated by a certified party for changes in VCG and LCG to the vessel's light ship characteristics. Calcs and determinations are to be forwarded to CG MSC for evaluation and approval. A new stability letter will need to be issued to reflect changes. Changes are minor vessel may operate until 1JUL17.
Due 1 July 2017
Resolved 14 July 2017
Resolution: MSC approved changes and issued new stability letter
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 June 2017 Resolved
Drill & training logs were not on board for verification. Vessel to provide proof of drill and training logs to MSU Chicago for verification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Log book was provided to show proof of drills and training have been conducted as required
Navigation › Piloting/Steering › Compass Deviation Table
Issued 1 June 2017 Resolved
Due to significant steel work completed and the addition of metal ballast the compass is to have it's deviation tables redone.
Due 8 June 2017
Resolved 14 July 2017
Resolution: new deviation table was provided
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 1 June 2017 Resolved
Hydrostatic release units for the IBAs are expired and must be replaced with new approved units.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: New Hydrostatic release was installed
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 1 June 2017 Resolved
The sewage waste line in the engine room has a significant leak. Make permanent repairs and prove leak free operation.
Due 8 June 2017
Resolved 1 June 2017
Resolution: sewage piping was repaired and verified to be leak free.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 June 2017 Resolved
Water tight cable penetrations in the fwd engineroom bulkhead are not water tight. Make all penetrations water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2017
Resolution: Pentrations were made watertight and verified by the attending MI.
Electrical › Electric Supply System (service) › Cable
Issued 1 June 2017 Resolved
There is a dead ended wire in the aft deck house overhead on the stbd side. Remove the cable or properly terminate the cable in a fixed junction box.
Due 8 June 2017
Resolved 14 July 2017
Resolution: Vessel properly terminated the cable in a junction box above the bar
Electrical › Electric Supply System (service) › Cable
Issued 1 June 2017 Resolved
An electrical cable under the stbd fwd bench on the weather deck is not properly supported. Support the cable with banding every 24".
Due 8 June 2017
Resolved 14 July 2017
Resolution: Properly installed metal cable supports every 24 inches
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2016 Resolved
Light fixture broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Corrected prior to completion of inspection.
Communications › Radio Communications › EPIRB
Issued 18 April 2016 Resolved
EPIRB Hydrostatic Release Expired
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Replaced with identical release prior to completion of inspction.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2016 Resolved
3 Adult and 1 Child Lifejacket unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 April 2016
Resolution: Replaced 3 adult and 1 childe lifejacket with proper identification markings prior to completion of inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2014 Resolved
Repair/replace electrical light fixture in compartment #4 46 CFR 183.05-35, 46 CFR 183.10-20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 7 July 2014
Resolution: Witnessed proper operation of light.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2014 Resolved
Repair/Replace electrical lighting fixture located above engien room hatch. 46 CFR 183.05-35, 46 CFR 183.10-20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 7 July 2014
Resolution: Tested new electrical light. All sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2014 Resolved
Repair ladder for compartment #4. 46 CFR 177.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2014
Resolved 31 July 2014
Resolution: Ladder in compartment #4 welded as required. Photo was sent to USCG from operator.
Engineering › Bilge Water Management System › Strainer
Issued 19 May 2014 Resolved
Repair/replace aft lazarette bilge strainer. 46 CFR 182.25-5
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Verified new strainer was placed in correct position.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 19 May 2014 Resolved
Electrical outlet in pilothouse incorrectly wired. 46 CFR 183.05-45
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Tested electrical socket, all sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 19 May 2014 Resolved
Remove A/C ground faulted circuits. 46 CFR 183.10-30, 46 CFR 111.05-11, 46 CFR 111.05-13
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: Two locations of ground fault were found. All wires repaired. No ground indicated on panelboard.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 19 May 2014 Resolved
Repair/replace ground detection meter. 46 CFR 183.10-30, 46 CFR 111.05-21, 46 CFR 111.05-27
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 14 July 2014
Resolution: Ground detection meter was reverse engineered and diagramed in absence of manual. All components are understood to be working correctly.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 19 May 2014 Resolved
Prove no ground fault exists on (+) of DC System. 46 CFR 183.05-50(d)(3) & (d)(5)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2014
Resolved 7 July 2014
Resolution: No ground fault exsists on vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2012 Resolved
Provide isolation transformer or other acceptable means to prevent the hull from carrying current while on shore power as required by 46CFR183.10-30.
Action required: 705 - Other - as specified
Due 1 May 2013
Resolved 20 May 2013
Resolution: Company installed an isolation transformer. Verified transformer and conductors added to vessel are of proper size and suitable for its intended service. Verified no ground-faults indicated on switchboard. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 June 2012 Resolved
Replace or repair per manufacturer’s directions the 28 unicellular adult life jackets that are cracking as required by 46CFR180.71.
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 27 August 2012
Resolution: Verified by counting that new life jackets were on board.
Construction/Loadline › Structures › Door
Issued 15 June 2012 Resolved
Repair the forward hatch for the engine room as required by 46CFR179.360(b)(2). One of the pins is missing from the hinge.
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 25 July 2012
Resolution: new pin installed and secured in place
Lifesaving › Work Vest › Approval
Issued 15 June 2012 Resolved
Replace work vests with the ones approved for use on a commercial vessel as required by 46CFR180.72(c) or (d). Current work vests do not meet the requirements of 46CFR160.053 or 160.077.
Action required: 705 - Other - as specified
Due 25 July 2012
Resolved 12 July 2012
Resolution: Received email showing receipt and product information for new work vests approved under 46CFR 160.053 as required. Work vests were purchased to replace existing work vests throughout the company''s fleet. All sat.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 9 November 2010 Resolved
11/09/2010 - During annual inspection held on 28 OCT 2010 (Misle activity number 3888018), the float free arrangement of inflatable buoyant apparatuses installed on the aft end of the vessel was brought into question. Senior marine inspector [name withheld] attended vessel and determined that the arrangement did not meet the float-free requirement of 46 CFR 180.130. Because of the closure of the Chicag
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 19 October 2011
Resolution: Company hired contractors to fabricate guide bars to keep IBAs from drifting into the canopy. Guide bar arrangment desiged by [name withheld] - registered Professional Engineer with Elliot Bay Design Group. See Misle documents for approval letters
Electrical › Electric Generation Source (service) › Generator
Issued 28 October 2010 Resolved
Prove proper operation of ships service generator.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2010
Resolved 29 October 2010
Resolution: Ships captain operated generator and demonstrated it could handle ships load. Cause of casualty was a faulty circuit board which was replaced by a Cummins tech rep.
Engineering › Fuel Oil Service System › Filter
Issued 9 October 2008 Resolved
Oil return line from oil filter to main engine was cracked and leaking oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 9 October 2008
Resolution: Replaced hose and ensured no leak remained.
Engineering › Bilge Water Management System › Pump
Issued 20 June 2008 Resolved
Bilge pump rating is for 40* C and needs to meet the 50* C requirement IAW 46 CFR 183.320
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 9 September 2008
Resolution: After reveiwing all specs, it is found that the current motor is acceptable by MSC for installation.
Engineering › Bilge Water Management System › Piping
Issued 4 April 2008 Resolved
Prior to carrying passengers, and upon plan approval, provide proof and make available to an attending CG marine inspector the firemain/bilge piping which was modified. All testing shall be in accordance with 46 CFR Subpart 182.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2008
Resolution: Witnessed operational testing of Fire main/ Bilge piping, all sat.
Communications › Radio Communications › EPIRB
Issued 12 October 2006 Resolved
Hydrostatic release expired. Prior to operating in excess of 1 nm from shore, replace hydrostatic release for EPIRB IAW 46 CFR 185.740(b).
Action required: 705 - Other - as specified
Resolved 18 October 2006
Resolution: Observed new hydrostatic release for EPIRB.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 May 2005 Resolved
Conduct annual examination as required by 46 CFR 176.500 to the satifaction of the attending marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Conducted annual inspection.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 6 May 2005 Resolved
Post correct type of lifejacket donning placards where they are stowed 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 25 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 May 2005 Resolved
Replace or renew bilge high level alarm to have a visual and audile alarm at the operating station in accordance with 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 25 May 2005
Engineering › Pressure Vessel › Relief Valve
Issued 6 May 2005 Resolved
Make air compressor located in engine available for internal inspection and the safety relief valve must be tested, 46 CFR 176.812.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 16 September 2005
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 6 May 2005 Resolved
Install main engine RPM gauge in accordance with 46 CFR 182.410(b) old T
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 25 May 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 12 September 2003 Resolved
Complete an new to zone inspection with [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2003
Resolved 12 September 2003
Documentation › Certificates/Documents › Stability Letter
Issued 12 September 2003 Resolved
Provide/Obtain a new valid stability letter. Issuing authority USCG MSC. (Inclining completed on, Sept 04, 2003)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2003
Resolved 6 May 2005
Resolution: There was already a copy of the new stability letter dated 19 November 2003 in the vessel''s file prior to conducting annual inspection 06 May 2005.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 September 2003 Resolved
Provide additional information which addresses vessels passenger capacity as per MSD Sturgeon Bay letter dated August 11, 2003.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2003
Resolved 6 May 2005
Engineering › Fuel Oil Storage/Transfer System
Issued 2 October 2002 Resolved
Clean or replace port fuel tank vent screen. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 23 October 2002
Resolved 20 November 2002
Resolution: Sighted new screens.
Electrical › Lighting (service)
Issued 2 October 2002 Resolved
Replace missing light guard in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 23 October 2002
Resolved 20 November 2002
Resolution: Sighted new light guards.
Electrical › Electric Generation Source (emergency)
Issued 2 October 2002 Resolved
Isolate for and remove electrical ground indicated on battery panel. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Due 23 October 2002
Resolved 20 November 2002
Resolution: Tested ground indication panal, Sat.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002 Resolved
Prove proper operation of switchboard power available indicators (generator & shore power). LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Due 23 October 2002
Resolved 20 November 2002
Resolution: Sighted working power available indicators.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 2 October 2002 Resolved
Replace two broken windows on house. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 23 October 2002
Resolved 20 November 2002
Resolution: New windows installed.
Stability › Watertight Integrity
Issued 5 February 2002 Resolved
Replace all deck hatch gaskets LEGACY COMPONENT DESC: Hatch Gaskets
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 May 2002
Fire Fighting › Structural Fire Protection - General
Issued 5 February 2002 Resolved
Remove plastic pipe "voice tube" from fwd E/R bulkhead and seal penetration. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Placed in Improper Service
Due 28 February 2002
Resolved 14 May 2002
Electrical › Electrical Distribution System (service)
Issued 5 February 2002 Resolved
Remove old wire run from fwd E/R bulkhead and seal penetration LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 May 2002
Engineering › Reduction Gearing/Clutches
Issued 5 February 2002 Resolved
Replace R/G fill/vent device with correct device. LEGACY COMPONENT DESC: Casing
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 May 2002
Fire Fighting › Combustible Materials
Issued 5 February 2002 Resolved
Pressure wash E/R bilge & E/R to remove oily build-up. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2002
Engineering › Shafting/Propeller Arrangements
Issued 5 February 2002 Resolved
At next haul-out remove screw to faciltate inspection of shaft key-way and hub. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2007
Resolved 28 August 2003
Resolution: Prop removed at credit drydock at Bayship in Sturgeon Bay, WI. Tail shaft key-way and hub examined satisfactory.
Accommodation/Occupational Safety
Issued 25 October 2001 Resolved
REPLACE BROKEN WINDO IN THE SNACK BAR PORT SIDE.
Condition: Unknown
Due 15 May 2002
Resolved 25 October 2001
Electrical
Issued 25 October 2001 Resolved
REPARIR OR REPLACE PORTSIDE GENERATOR (LEAKING OIL INTO THE WATER)
Condition: Unknown
Due 15 May 2002
Resolved 14 May 2002
Electrical
Issued 25 October 2001 Resolved
REPLACE WIRE RUN FROM ENGINE ROOM TO P/S RUNNING LIGHTS.
Condition: Unknown
Due 15 May 2002
Resolved 14 May 2002
Engineering
Issued 26 October 2000 Resolved
INSTALL GUARD OVER M/E ALTERNATOR.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Construction/Loadline
Issued 26 October 2000 Resolved
REPAIR F/W TANK VOID BILGE ALARM & PROVE PROPER OPERATION.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 26 October 2000 Resolved
REPLACE 7 ADULT PFDS.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Navigation
Issued 26 October 2000 Resolved
MAKE NEC REPAIRS & PROVE PROPER OPERATION OF NAV LIGHTS.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 26 October 2000 Resolved
FLOAT TEST ALL BOUYANT APPARATUS ON ALL DEEP RIVER NAVIGATION BOATS
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Engineering
Issued 5 October 1999 Resolved
Replace s/w cooling hoses on both sides of the water pump on the stbd gen.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Accommodation/Occupational Safety
Issued 5 October 1999 Resolved
Replace broken glass in the main cabin w/ safety glass.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 5 October 1999 Resolved
Provide five PFD's for the ones that failed.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 5 October 1999 Resolved
Provide metal trash cans to replace the plastic ones.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 5 October 1999 Resolved
Provide donning instruction placards for each type of life jacket on board.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 5 October 1999 Resolved
Provide deviation card
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Electrical
Issued 5 October 1999 Resolved
Remove extension cords from the bridge, (Plug-ins for air compressor, dustbuster).
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Electrical
Issued 5 October 1999 Resolved
Provide the proper wire ties in the passenger compartment.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 5 October 1999 Resolved
Provide current and tide tables.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 14 October 1998 Resolved
INSTALL RUDDER ANGLE INDICATOR FOR EMG STEERING STATION.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Lifesaving
Issued 14 October 1998 Resolved
PROVE LIFE RINGS ARE CG APPROVED.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Electrical
Issued 14 October 1998 Resolved
INSTALL METAL WIRE TIES THROUGH OUT VSL.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Electrical
Issued 14 October 1998 Resolved
MAKE PROPER WIRE CONECTION UNDER PORT FWD BENCH.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Construction/Loadline
Issued 14 October 1998 Resolved
ENSURE BOLT HOLES IN LAZ. GET FILLED WHEN RUB RAIL IS REPLACED.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Lifesaving
Issued 14 October 1998 Resolved
INSTALL RETRO TAPE ON BUOYANT APP.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Lifesaving
Issued 14 October 1998 Resolved
REPLACE RETRO TAPE ON 25 LIFE JACKETS.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Lifesaving
Issued 14 October 1998 Resolved
REPLACE 20 LIFE JACKETS THAT WERE FADED OUT.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Fire Fighting
Issued 14 October 1998 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Electrical
Issued 22 October 1997 Resolved
Clean areas around battery boxes where corrosion is present.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Construction/Loadline
Issued 22 October 1997 Resolved
Repack forward depth sounder hull connection at next drydock.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Electrical
Issued 22 October 1997 Resolved
Remove dead end wire in ladies head.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Fire Fighting
Issued 22 October 1997 Resolved
Provide one B-I fire extinguisher. Vessel may not carry passengers until provided.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Fire Fighting
Issued 22 October 1997 Resolved
Provide portable hand pump.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 22 October 1997 Resolved
Provide 2 adult life preservers. Vessel is restricted to 138 persons until provided.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 22 October 1997 Resolved
Replace three boken windows.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Engineering
Issued 22 October 1997 Resolved
Repair/replace port generator exhaust muffler.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Navigation
Issued 10 October 1996 Resolved
Prove navigation lights meet UL standard 1104 or replace with ones that comply with this standard.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Electrical
Issued 10 October 1996 Resolved
remove extension cord for microwave. Plug into fixed outlet.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Engineering
Issued 10 October 1996 Resolved
Provide chaffing gear between fuel line and bottom long in port aft engineroom.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Lifesaving
Issued 10 October 1996 Resolved
Provide guards on the main engine and port generator.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Navigation
Issued 10 October 1996 Resolved
Replace cotter pin and cut steel edges of steering cable run in compartment#2.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Lifesaving
Issued 10 October 1996 Resolved
Provide 100 ft painter for forward buoyant apparatus.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Lifesaving
Issued 10 October 1996 Resolved
Refasten metal clip on aft buoyant apparatus, starboard side.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Lifesaving
Issued 10 October 1996 Resolved
Provide 11 adult life preservers. Vessel limited to 129 adults additional ones are added.
Condition: Unknown
Due 24 October 1996
Resolved 6 May 1997
Lifesaving
Issued 10 October 1996 Resolved
Provide one pendant for aft buoyant apparatus.
Condition: Unknown
Due 24 October 1996
Resolved 8 May 1997
Electrical
Issued 13 October 1995 Resolved
Provide pressure type wire connector to MSD pump.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Electrical
Issued 13 October 1995 Resolved
Secure light fixture in women's head.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Electrical
Issued 13 October 1995 Resolved
Clean forward battery box in engineroom of corrosion.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Accommodation/Occupational Safety
Issued 13 October 1995 Resolved
Permanently mount fresh water pump. Ensure inlet/outlet secure.
Condition: Unknown
Due 22 November 1995
Resolved 21 November 1995
Electrical
Issued 13 October 1995 Resolved
Remove/repair light fixture in void #5.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Navigation
Issued 13 October 1995 Resolved
Secure excess steering cable in void #5 with metal clamps/wires.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Navigation
Issued 13 October 1995 Resolved
Permanently secure air compressor on top of pilot house.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Electrical
Issued 13 October 1995 Resolved
Renew wire to air compressor.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Electrical
Issued 13 October 1995 Resolved
Provide blank and label electric boxes in engineroom.
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Fire Fighting
Issued 13 October 1994 Resolved
HYDROSTATICALLY TEST TWO CO2 FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 13 October 1994 Resolved
PROVIDE 20 ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO 120 TOTAL PERSONS UNTIL THIS REQUIREMENT IS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Fire Fighting
Issued 17 October 1989 Resolved
PROVIDE HYDROSTATIC TESTING AND SERVICING OF 2 B-II PORTABLE FIRE EXTIN- GUISHERS.
Condition: Unknown
Due 17 October 1989
Resolved 17 October 1989
Lifesaving
Issued 17 October 1989 Resolved
PROVIDE 2 USCG-APPROVED TYPE I ADULT PFDS. TOTAL NUMBER OF PERSONS PER- MITTED ON VSL BY COI TO BE REDUCED TO NUMBER OF SATISFACTORY PFDS ONBOARD VSL (TOTAL PERSONS= 138)
Condition: Unknown
Due 17 October 1989
Resolved 17 October 1989
Accommodation/Occupational Safety
Issued 25 October 1984 Resolved
REPAIR OR REPLACE TOILET FLUSHING UNIT IN MEN'S TOILET.
Condition: Unknown
Due 25 October 1984
Resolved 25 October 1984
Construction/Loadline
Issued 25 October 1984 Resolved
REPAIR OR REPLACE ALL LOOSE WOOD SHEATHING ON MAIN DECK.
Condition: Unknown
Due 25 October 1984
Resolved 25 October 1984
Documentation
Issued 25 October 1984 Resolved
PROVIDE AND POST ON BOARD, FCC STATION LICENSE AND FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 25 October 1984
Resolved 25 October 1984

Casualty record · 11

25 May 2003Routine · role: Involved in a Marine Casualty · activity 1808663
3 September 2006Routine · role: Involved in a Marine Casualty · activity 2792681
29 May 2010Routine · role: Involved in a Marine Casualty · activity 3754458
1 June 2010Routine · role: Involved in a Marine Casualty · activity 3755634
28 October 2010Routine · role: Involved in a Marine Casualty · activity 3885569
31 May 2016Routine · role: Involved in a Marine Casualty · activity 5902192
29 August 2019Routine · role: Involved in a Marine Casualty · activity 6847182
12 October 2019Routine · role: Involved in a Marine Casualty · activity 6834702
7 November 2019Routine · role: Involved in a Marine Casualty · activity 6851501
11 August 2021Routine · role: Involved in a Marine Casualty · activity 7291262
10 September 2021Routine · role: Involved in a Marine Casualty · activity 7378233
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LADY FENWICK (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.