MAURY USCG vessel records
← All vessels

KIRBY 20770

Built
1980
Last inspected
4 September 2013
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 13 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 4 September 2013
…with no type recorded30
Operational controls None recorded without a removal date
Years with a record 32 calendar years (1982–2013)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
1377 - Regulatory (Subpart C or D), Gross Ton 1377 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-51160
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

CAPT FRANK STALLINGS Towing Vessel · MISLE 99255 · 7 March 2012 · activity 4258808GEORGE BUXTON Towing Vessel · MISLE 180179 · 1 July 2007 · activity 2980623JANE L Towing Vessel · MISLE 152241 · 10 February 1998 · activity 106063

Inspection history · 72

4 September 2013 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4758022
18 June 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4393950
7 March 2012 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4258808
23 August 2011 Deficiency Check · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4125258
8 August 2011 COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4109081
11 July 2011 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4077819
20 July 2010 Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3931987
4 June 2009 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3540505
5 May 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3467820
5 March 2009 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3430182
26 February 2009 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3424355
25 June 2008 Internal Structural Exam · Drydock Exam · COI Inspection · MTSA Verification · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3247318
7 January 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3137528
18 July 2007 Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2999514
2 July 2007 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2980561
1 July 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2980623
1 February 2007 MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2874672
15 December 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2840939
15 December 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2840994
24 May 2006 Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2657710
5 July 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2415897
14 January 2005 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2274381
13 January 2005 Annual Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2287741
13 January 2004 COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1957183
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1995762
25 November 2003 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1954742
7 September 2003 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1899082
11 August 2003 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1902481
26 August 2002 Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1668418
4 October 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 772083
20 November 2000 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 824582
4 January 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1047993
10 May 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 466849
8 January 1999 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1410005
24 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 437714
10 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 106063
17 October 1997 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1112966
2 October 1996 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834579
16 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 487980
25 October 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445024
7 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479778
12 October 1994 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864372
8 October 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422282
21 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 527786
5 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 530566
5 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 508278
28 February 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 526378
12 November 1992 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 827101
30 July 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 446041
4 May 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 451825
13 November 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 444059
8 November 1991 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 940466
29 September 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 443395
17 August 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 468541
12 February 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 491576
8 February 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 484758
5 December 1990 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 928686
13 July 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213834
25 June 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 460868
9 April 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911570
14 April 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041906
12 April 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031282
2 March 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027032
30 November 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 523435
22 July 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025664
23 April 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302733
3 July 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 446430
3 July 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 519784
26 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292254
30 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974881
26 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271194
30 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967294

Deficiency record · 12

Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 August 2011 Resolved
#4 port cargo envelop has wasted hole approx. 1x1 in.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2011
Resolved 26 August 2011
Resolution: Pressure test conducted on all tanks. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 23 August 2011 Resolved
#1 port block valve stem is wasted at the penetration point of the cargo envelope.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2011
Resolved 26 August 2011
Resolution: Valve stem replaced, pressure test conducted. All set.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 20 July 2010 Resolved
Cargo piping discharge valve was inoperable on the port bow of the vessel. Master stated that only the piping/valves on the stern of the vessel are used.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2010
Resolved 20 July 2010
Resolution: Shipyard conducted maintenance on the cargo valve; valve fully operational.
Deck/Cargo › Cargo Stowage › General
Issued 20 July 2010 Resolved
The flame screen on No. 3P P/V valve was torn/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2010
Resolved 20 July 2010
Resolution: The flame screen on No. 3P P/V valve was replaced by Bludworth Shipyard personnel.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 July 2010 Resolved
D.O. Fuel tank was not properly stenciled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2010
Resolved 20 July 2010
Resolution: D.O. fuel tank was re-stenciled.
Documentation › Markings/Placards › Warning Signs
Issued 20 July 2010 Resolved
Vessel was missing its warning sign placard, as required by 46CFR35.30-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2010
Resolved 20 July 2010
Resolution: Warning sign replaced with a new (legible) one.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 26 February 2009 Resolved
Required to repair corroded section of main suction valve stanchion prior to loading.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2009
Resolved 5 March 2009
Resolution: Suction valve stanchion replaced, completed satisfactory air test.
Construction/Loadline › Hull › Hull Plating
Issued 2 July 2007 Resolved
As the result of an impact, the #2 stbd wing void has a 4' section of deck gunnel that is inset, folded, and holed as well as a 4' sharp gouged inset at the 4' draft mark.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 18 July 2007
Resolution: Permanent repairs made.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 January 2005 Resolved
Submit plans to the CG for review for cargo piping drain valve and associated piping.
Due 14 February 2005
Resolved 5 July 2005
Resolution: Plans submitted and approved.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 January 2005 Resolved
Revise vessel cargo piping diagram to include new cargo piping drain valve and associated piping and submit to the CG for review.
Due 14 February 2005
Resolved 5 July 2005
Resolution: Cargo piping diagram revised. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 January 2005 Resolved
Revise cargo transfer procedures to reflect changes made to the cargo piping and submit to the CG for review.
Due 14 February 2005
Resolved 5 July 2005
Resolution: Cargo transfer procedures revised. All sat.
Deck/Cargo › Holds/Tanks
Issued 25 November 2003 Resolved
Cargo tank holed in way of wastage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2003
Resolution: 24" x 24" x 3/8" insert.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.