Records from 2002 to 2016. Most recent: inspection, 8 September 2016.
Documentation › Logs/Records › Drug Test Records
Issued 23 May 2005
Resolved
Vessel could not provide valid proof of enrollment in a drug testing consortium. Contract onboard was expired. Proof of enrollement required prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 May 2005
Resolved
Vessels radar was inoperable.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Lifesaving › Hand Flares › Expired
Issued 23 May 2005
Resolved
Vessels pyrotechnics were expired. Replacement required prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 3 January 2006
Resolution: New flares provided.
Lifesaving › Lifefloat › Float Free
Issued 23 May 2005
Resolved
Vessels life float was not float free (tied down). Required to be float free prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 3 January 2006
Resolution: Vessel equipped with EPIRB and has route no more than 3 miles from land - primary lifesaving not required and requirement cleared.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 May 2005
Resolved
Vessel did not have automatic engine shutdown and required alarms for the engine room halon system.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 3 January 2006
Resolution: Automatic shutdown and alarms installed and tested, requirement cleared.
Lifesaving › Lifebuoys › Approval
Issued 23 May 2005
Resolved
Vessels ring bouy was not CG approved - CG approved equipment required prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 3 January 2006
Resolution: Approved ring bouys provided.
Fire Fighting › Fire Pumps › Impeller
Issued 23 May 2005
Resolved
Vessels main engine driven fire pump was inoperable. Pump is required to be operable prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 3 January 2006
Resolution: fire pump not required and was removed - requirement cleared.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 May 2005
Resolved
Vessel is to renew the main engine wet exhaust system due to wastage and numerous leaks.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 23 May 2005
Resolved
Vessels fuel tanks are to be audio gauged in the presence of a marine inspector.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Construction/Loadline › Hull › Bottom Plating
Issued 11 May 2005
Resolved
Vessel is to renew a 4' section of the garboard strake, port side IWO excessive marine borer damage prior to operating.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Planking was renewed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 May 2005
Resolved
Vessel is to renew collision bulkhead IWO excessive freshwater rot prior to operating.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 23 May 2005
Resolution: New section of collission bulkhead was cropped in and reinforced - accepted repairs and cleared requirement.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2005
Resolved
Vessel is to replace bungs, where missing, for fasteners.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Bungs were replaced.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2005
Resolved
Rot IWO stem bolts is to be removed and treated and missing bungs are to be replaced.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Rot removed and bungs replaced.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2005
Resolved
Vessel is to treat rot IWO of rudder post void box and cover with epoxt coating prior to operating.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Corrected
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 May 2005
Resolved
Vessel is to submit repair proposal for numerous rotted under deck longs throughout the vessel prior to operating. 23MAY05 - Proposal received. Vessel allowed 30 days to complete repairs while operating.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Construction/Loadline › Hull › Sheerstrake
Issued 11 May 2005
Resolved
Vessel is to submit repair proposal for replacement of the sheer plank, port side, IWO excessive rot prior to operating. 23MAY05 - Received repair proposal. Vessel allowed 30 days to complete repairs while operating.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Construction/Loadline › Hull › Hull Plating
Issued 11 May 2005
Resolved
Vessel is to make permanent and proper repairs IWO old thru hull fitting, starboard side, which has been plugged with a wooden dowel, prior to operating.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 May 2005
Resolved
Vessel did not have valid CPR cards for 50% of crew.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 30 November 2006
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 11 May 2005
Resolved
Vessels main engine cooling system was inoperable due to wastage and numerous leaks. Repairs required prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 8 September 2016
Resolution: Vessel COI deactivated and removed from service - admin clear 835.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 May 2005
Resolved
Vessels high water bilge alarms were inoperable. Repairs required prior to operating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 3 January 2006
Resolution: alarm tested satisfactorily and cleared.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 11 May 2005
Resolved
Vessels fuel filters were not fitted with flame impingement bowls.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 3 January 2006
Resolution: flame bowls fitted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 23 June 2004
Resolved 23 June 2004
Lifesaving › Buoyant Apparatus
Issued 1 October 2003
Resolved
MAKE LIFEFLOAT FLOAT FREE.
Condition: Improper Installation
Due 3 October 2003
Resolved 7 October 2003
Lifesaving › Buoyant Apparatus
Issued 1 October 2003
Resolved
PROPERLY INSTALL AND SECURE WEAK LINK ON LIFEFLOAT.
Condition: Improper Installation
Due 3 October 2003
Resolved 7 October 2003
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 October 2003
Resolved
RENEW RETRO-REFLECTIVE TAPE ON FOUR ADULT LIFEJACKETS.
Condition: Improper/Lack of Maintenance
Due 3 October 2003
Resolved 7 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 1 October 2003
Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR TWO PORTABLE FIRE EXTINGUISHERS IN AFT ACCOMMODATION SPACE.
Condition: Improper Installation
Due 3 October 2003
Resolved 7 October 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 October 2003
Resolved
PROVIDE CURRENT LIGHT LIST.
Condition: Improper/Lack of Maintenance
Due 3 October 2003
Resolved 7 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 October 2003
Resolved
PROVIDE PROPER DECK RAILS ON BOW OR PROVIDE A MEANS TO PREVENT PASSENGERS FROM HAVING ACCESS TO THE BOW. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 10 October 2003
Resolved 15 October 2003
Fire Fighting › Fixed Fire Detection System
Issued 29 May 2002
Resolved
Install operational smoke detectors in engine room, main, aft and fwd cabin. LEGACY COMPONENT DESC: Smoke Detectors
Due 5 June 2002
Resolved 6 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 29 May 2002
Resolved
Properly secure all rails on vsl. LEGACY COMPONENT DESC: Deck Rail
Due 5 June 2002
Resolved 6 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 29 May 2002
Resolved
Install rails on port and starboard side of bow. LEGACY COMPONENT DESC: Hand Grab
Due 5 June 2002
Resolved 6 June 2002
Engineering › Bilge Water Management System
Issued 29 May 2002
Resolved
Provide main bilge piping composed of ferrous materials. LEGACY COMPONENT DESC: Piping
Due 5 June 2002
Resolved 6 June 2002
Electrical › Electric Supply System (service)
Issued 29 May 2002
Resolved
Provide covers for all batteries in the engine room. LEGACY COMPONENT DESC: Battery Installation
Due 5 June 2002
Resolved 6 June 2002
Engineering › Fuel Oil Service System
Issued 29 May 2002
Resolved
Install a 30X30 screen on the fuel vent. LEGACY COMPONENT DESC: Vent Pipe
Due 5 June 2002
Resolved 6 June 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 May 2002
Resolved
provide a means to close the vent to the engine room.
Due 5 June 2002
Resolved 6 June 2002
Communications › Radio Communications
Issued 29 May 2002
Resolved
Install an emergency broadcast placard. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 5 June 2002
Resolved 6 June 2002
Operations/Management › Drills/Instruction
Issued 29 May 2002
Resolved
Provide a means to retrieve a person in the event of "man overboard". LEGACY COMPONENT DESC: Man Overboard Recovery
Due 5 June 2002
Resolved 6 June 2002
Communications › Radio Communications
Issued 29 May 2002
Resolved
Voyages restricted to 3 miles from shore until EPIRB is properly installed and registered with NOAA. LEGACY COMPONENT DESC: EPIRB
Due 5 June 2002
Resolved 6 June 2002