MAURY USCG vessel records Sign in
← All vessels

TOMAHAWK

TOMAHAWK is a 1980 passenger vessel (inspected). The Coast Guard has recorded 122 inspections since 1984, most recently in March 2026, along with 197 deficiencies — 1 with no resolution recorded —, 1 operational control and 5 casualty investigations between 2002 and 2017.

Records from 1984 to 2026. Most recent: inspection, 12 March 2026.

Built
1980
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3596
Flag
UNITED STATES
368046780
Maury page id
psix-51208

Inspections, by type

…with no type recorded30
…past their stated due date1
Years with a record 41 calendar years (1984–2026)
The 122 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 22.2 ft × 7.5 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT C FLETCHER · HERMOSA BEACH, CA, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3596MMSI 368046780 · active · compulsorily equipped · granted 23 June 2018, expires 23 June 2028
WDD7092MMSI 367181830 · expired · compulsorily equipped · granted 21 April 2007, cancelled 24 June 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC5431MMSI 367040980 · expired · compulsorily equipped · granted 10 May 2005, cancelled 11 July 2015
WCP2506MMSI not assigned · expired · compulsorily equipped · granted 6 December 1994, cancelled 5 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SPEED TWIN Passenger (Inspected) · MISLE 46739 · 10 September 2001 · activity 50808

Inspection history · 122

12 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8310323
3 December 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8277165
16 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8112713
18 November 2024 Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8036729
15 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8019440
4 August 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7980545
14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912514
28 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7871516
16 January 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849859
25 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7785568
7 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646879
23 May 2022 Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457262
2 April 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504033
23 September 2021 Damage Survey · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319123
21 September 2021 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7317578
10 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7221308
10 June 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6972968
23 January 2020 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6894613
6 December 2019 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6868703
11 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6832800
8 April 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6653973
5 September 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6533370
9 July 2018 Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6473270
4 January 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332607
6 December 2017 Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317775
9 August 2017 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6235696
9 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6242916
25 July 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6220589
20 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6181319
7 January 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080696
19 September 2016 Type not recorded
No type recorded · USCGC ASPEN (WLB 208) · USCG Arctic District (CGD-A) · Activity 6018774
13 April 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5853734
8 December 2015 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5777087
8 May 2012 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4305504
16 December 2011 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4203954
29 July 2011 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4098583
16 February 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677083
2 February 2010 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3663371
7 April 2009 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3447938
24 August 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3309676
30 June 2008 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3235904
8 February 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3143755
18 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2925152
24 April 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2914930
2 June 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2659955
17 May 2005 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2361736
11 May 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2334865
8 November 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2235712
18 February 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2016022
2 February 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1998888
8 July 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1833401
27 July 2002 Type not recorded
No type recorded · Station Channel Islands Harbor · USCG Southwest District (CGD-SW) · Activity 1657424
28 April 2002 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1611251
16 April 2002 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1605124
18 January 2002 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1480000
25 September 2001 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1073699
24 September 2001 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 12982
24 September 2001 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1477238
24 September 2001 Type not recorded
No type recorded · Station Channel Islands Harbor · USCG Southwest District (CGD-SW) · Activity 1522982
12 September 2001 Deficiency Check · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391681
10 September 2001 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 50808
21 May 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432505
12 April 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1461382
27 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437888
2 February 2001 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1058755
26 April 2000 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397412
26 January 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384324
11 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 152597
5 May 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381562
14 April 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381538
1 March 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 793332
20 January 1999 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369016
15 April 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364707
26 February 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1119578
7 January 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1466498
14 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406111
6 May 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452157
4 April 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 752654
3 April 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 206873
11 January 1996 Damage Survey · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380413
10 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 147408
17 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1188686
12 May 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355228
16 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155051
3 February 1995 Type not recorded
No type recorded · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 685545
26 August 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394165
17 August 1994 Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380071
20 August 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 146436
11 May 1993 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387330
14 December 1992 Excursion Permit · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393883
12 August 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 959655
30 June 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 947280
3 June 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 945490
29 May 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 959012
8 May 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1263193
13 February 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 958647
12 December 1991 Drydock Extension · Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1356101
13 July 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1212702
28 June 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1221575
8 June 1990 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1242748
1 June 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1215035
23 April 1990 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214795
27 January 1990 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1236767
28 November 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237031
5 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1345045
3 May 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1036445
9 December 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1209455
14 October 1988 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1197117
13 May 1988 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1040411
28 April 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1343269
15 May 1987 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1025237
28 April 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1011249
14 November 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1325300
27 October 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1318215
28 April 1986 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 999976
24 January 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 995825
12 December 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990240
5 December 1985 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295206
3 December 1985 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 986274
30 August 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 986576
25 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1290651
6 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284815

Deficiency record · 197

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 March 2026 Resolved
Expired 2/26
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 28 April 2026
Resolution: Vessel provided photo of an active COD to CG inspector via email.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 March 2026 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 26 March 2026 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 March 2026 Resolved
FCC Marine Radio Operator Permit missing
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received proof owner/operator obtained his Marine Radio Operator Permit.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 12 March 2026 Resolved
Failed to conduct and document monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received photograph of log containing record of monthly EPIRB test.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 March 2026 Resolved
No light for magnetic compass
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 March 2026 Resolved
Sound producing device broken.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 March 2026 Resolved
Missing 3 red flares
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2026 Resolved
Incorrect labeling of max passengers on top side deck (states 0 correct number is 8)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 March 2026 Resolved
Portable lights missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 March 2026 Resolved
Fire alarm system not interconnected IAW IFR.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2026 Resolved
Missing outlet covers and overhead electrical cables need to be supported.
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received photograph showing that the covers were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2026 Resolved
Bilge pumps in forward peak inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 January 2026 Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers. 46CFR177.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2026
Resolution: egress drills complete, no issues found.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2025 Resolved
Provide proof of drug and alcohol program enrollment for all employees who have a safety sensitive position on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Received updated crew enrollment list.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Provide unused engine room fuel tank sight glass with threaded caps on valves to prevent accidental leaks if valves were to open.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Recieved photos of capped valves.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Prove proper operation of failed port side fuel shutoff valve. -Prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 17 April 2025
Resolution: Repairs made, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Prove proper operation of inoperable bilge pump. -Prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 17 April 2025
Resolution: Repair to air leak found, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2025 Resolved
Provide generator / shore power breakers with interlock device to prevent both breakers being energized simultaneously.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Recieved photo of device installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2024 Resolved
Only two crew members are listed on the vessel's DAPI program for 2024. Update crew list with DAPI program's drug consortium.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Other crew members were drug tested and entered into the vessel's DAPI program.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2024 Resolved
Large openings in the aft bulkhead of the engine room prevent the space for being adequately vapor tight for the fixed fire fighting system. Seal the open bulkhead penetrations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Holes were sealed with plywood and foam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
A battery charger in the engine room was cracked open and had an unauthorized temporary repair in place. Remove/replace the damaged battery charger. To be rectified by 28 May 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: Battery charger was removed and a new one has been ordered.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 May 2024 Resolved
FCC Radiotelephony Safety Certificate was expired. Acquire a new FCC Radiotelephony Safety Certificate. To be rectified by 13 June 2024. Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 16 May 2024
Resolution: A new cert was issued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Power cables were laying in bilge of the engine room. Some of the affected cables were improperly dead-ended. Install the affected cables as high as practicable above the bilge, and remove or properly dead-end all dead end wires in junction boxes or with pressure type connectors. To be rectified by 28 May 2024. Cites: 46 CFR 183.05-50(a)(Old-T) & 46 CFR 183.05-50(b)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: Power cables were re-routed above the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Light switch at entrance to engine room is missing its faceplate. Replace the affected faceplate. To be rectified by 28 May 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: A new faceplate was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024 Resolved
Port MDE fuel pump was leaking excessively. Repair/replace the affected fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2024
Resolution: Pump was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2024 Resolved
Vessel failed to receive CG Drydock and Internal structure exam as reflected on the Certificate on Inspection. Complete Drydock and Internal Structure Exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Completed Drydock exam
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023 Resolved
Vessel does not have evidence of DAPI enrollment. Provide documentary evidence of enrollment in an appropriate drug and alcohol testing program.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2023
Resolution: Vessel operator sent in paperwork from ASTS proving enrollment in DAPI program.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 March 2023 Resolved
Vessel's EPIRB is not appropriately registered. Update EPIRB registration with NOAA. Vessel is restricted to a Lakes, Bays, and Sounds route until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 10 March 2023
Resolution: Received email with new registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Engine room hot water heater: cable connector not properly installed; Repair.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Generator wiring conductor spliced with wire nut; Repair with proper mechanical sealed splice. 46CFR183.200 (b) 16C
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
STBD side forward of Main Engine Fresh water pump end bell cover missing; Install cover.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Portside Accommodation forward HVAC unit wiring spliced with wire nuts; Install approved electrical Junction box for wiring termination.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 23 May 2022 Resolved
Galley griddle unit electrical power connection not properly sealed; Repair.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 September 2021 Resolved
Based on the structural failure and a review of the history of similar failures on the vessel, the OCMI has questioned the structural adequacy of the vessel. Prior to returning to service, you must prove the structural adequacy of the vessel by submitting plans and calculations which demonstrate compliance with the standards established by a recognized classification society to the Marine Safety Center for approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2021
Resolved 1 December 2021
Resolution: Vessel underwent plan review w/ collaboration of naval architect and MSC to bring vessel into Lloyds wood vessel rules structural standards.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 September 2021 Resolved
46 CFR 176.600 (d) Whenever damage to hull plating or structural members may affect the seaworthiness of a vessel is discovered or suspected, OCMI may conduct an internal structural examination in any affected space and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permenant repairs. Starboard bow suffered significant damage to include delamination of outer sheets. In forepeak - observed multiple deck support beams to be rotted and the forwardmost transverse frame fractured. Vessel is required to undergo full ISE and drydock examination to asses damage and affect repairs prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2021
Resolved 1 December 2021
Resolution: Vessel underwent new plan review w/ MSC after it was found the structure did not comply with applicable wood boat rule set and experienced multiple structural failures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2021 Resolved
Port and Starboard remote shut-off rods to the main fuel valves from fuel tank were seized and sheared. Must replace or install new remote means to shut off fuel valves prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Corrected on spot
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2021 Resolved
Must install modular smoke detector in salon area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 26 June 2021
Resolution: Verified smoke detector was installed - [name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 June 2021 Resolved
Forward Bulkhead penetrations need to be made water/vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 2 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Generator Racor filter is missing flame bowl. Must provide fire resistant bowl.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 28 June 2021
Resolution: Verified flame bown installed - [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 10 June 2021 Resolved
Must clean the fuel out of the port/stbd main engine racor bowls.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2021 Resolved
Must install chains on all exposed deck hatches. Hatch covers to lazzerette space missing chain.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 June 2021 Resolved
Must properly mount starboard light fixture in the lazzerette space.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 June 2021 Resolved
Must fix leak on the raw water intake for the generator at the elbow section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 8 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Must properly mount the bilge pump motor to prevent damage to the pump system.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Provide lagging gear or install mounting bracket on cooling water marine hose to prevent contact with the turbo charger on the port main engine.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on Spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020 Resolved
Life jacket light batteries were installed backwards. Correct light batteries on all life jackets and verify proper operation.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Install escape lighting in passenger berthing area in way of emergency escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 11 October 2019
Resolution: Light installed & tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2019 Resolved
Install smoke detector in galley space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Installed & tested.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 11 October 2019 Resolved
Remove rug from emergency escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Rug was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Secure switch and cover 12V electrical equipment in passenger berthing below stair cases.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Switch and cover was secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2019 Resolved
Remove combustible waste cans from galley area.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Replaced with metal can.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Repair galley outlet cover behind coffee maker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Cover was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Repair insulation for galley feeder cable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 11 October 2019
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Terminate dead-end wire in way of steering pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Wire was terminated.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 October 2019 Resolved
Remove fuel oil from bilge and tank top.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Cleaned bilges and tank top.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2019 Resolved
Replace tank sight glass and valves with non-combustible sight glass (guarded to prevent damage) and quick closing valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2019
Resolved 6 December 2019
Resolution: Sight glass and valves were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 30 January 2020
Resolution: A/C 1-line dwg provided, review completed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 July 2018 Resolved
Prove proper operation of the bilge high water alarm system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: All alarms operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Properly mount electric gray/black water pumps to foundations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Pumps secured to foundation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2018 Resolved
Provide 5 adult type 1 PFDs (operations restricted to 50 adult persons).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Lifejackets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 July 2018 Resolved
Install captive chains on hatches exposed to weather.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Captive devices installed.
Construction/Loadline › Hull › Side Shell
Issued 10 August 2017 Resolved
Remove all damaged hull materials to good hull/structure and make ready for Coast Guard Inspectors.
Condition: Damaged By Earlier Event
Due 3 January 2018
Resolved 16 August 2017
Construction/Loadline › Hull › Side Shell
Issued 10 August 2017 Resolved
Provide a list of materials and plans for repair for Coast Guard approval. All repairs to be completed using the guidance from NVIC 7-95 or better.
Condition: Damaged By Earlier Event
Due 3 January 2018
Resolved 16 August 2017
Construction/Loadline › Hull › Side Shell
Issued 9 August 2017 Resolved
Haul out vessel for a damage survey by CG Marine Inspectors.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2017
Documentation › Certificates/Documents › Stability Letter
Issued 20 June 2017 Resolved
Provide a stability letter prior to ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2017
Resolved 5 July 2017
Resolution: Provided a stability letter prior to ops.
Documentation › Logs/Records › Drug Test Records
Issued 20 June 2017 Resolved
Provide DAPI program prior to OPS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provided DAPI program prior to OPS
Lifesaving › Hand Flares › Quantity
Issued 20 June 2017 Resolved
Provide 6 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provide 6 red hand flares.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 20 June 2017 Resolved
Provide secure mount for the SSDG exhaust system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provided secure mount for the SSDG exhaust system.
Construction/Loadline › Structures › Deck Plating
Issued 20 June 2017 Resolved
Make permanent repairs stbd main deck fwd on the house on the main deck where the repairs are incomplete.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Make permanent repairs stbd main deck fwd on the house on the main deck where the repairs are incomplete.
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2017 Resolved
Make permanent/approved repair to the port hull in the engine room where there's evidence of saltwater intrusion & rot.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Made permanent/approved repair to the port hull in the engine room where there's evidence of saltwater intrusion & rot.
Lifesaving › Lifefloat › Float Free
Issued 16 December 2011 Resolved
Provide lifefloats in a float free arrangement. Currenlty 2 deck boxes house 2 lifefloats each (4 total) on bridge deck. Overhanging cabin top, tight fit of floats inside boxes, lack of freeflow ports in boxes, and covers on boxes inhibit floats from floating free from vessel. This requirement is reinstated from June 2011.
Action required: 705 - Other - as specified
Due 15 March 2012
Resolved 29 March 2012
Resolution: Verified installation of new liferafts. Description in narrative.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 June 2009 Resolved
DAPI program not in compliance. Provide pre-Employment drug test for all members employed, enroll all members into drug program, provide proof of members signed Eclipse Policy, post Employee help number in general location, and provide 2008 MIS report for M/V Renegade IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 25 June 2009
Resolved 25 June 2009
Resolution: O/O provided proof of DAPI program in compliance with 46 CFR 16.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 June 2009 Resolved
Provide proof of all Captains and Supervisors attending a drug and alcohol awareness training within 3 months of today's date IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 18 September 2009
Resolved 24 February 2010
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 June 2009 Resolved
Port fuel shutoff handle needs replaced and new handle secured to valve IAW 46 CFR 182.455
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O removed and replaced Fuel shutoff handle to valve.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2009 Resolved
Bilge pump inop. Provide proof of operation to marine inspector.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O repaired bilge pump and proved operation to Marine Inspector.
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 18 June 2009 Resolved
Submit generator power repower documents to OCMI. Provide manufactory data and date of installation on provided documents.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O provided generator repower documents. Generator inspection completed to satisfaction MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 June 2009 Resolved
CO2 shutoff switches need to be installed on generator and ops check complete to satisfaction Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2009
Resolution: O/O installed CO2 engine shutoff switch to generator and ops checked to satisfaction of Marine Inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 18 June 2009 Resolved
Bilge high level alarm in forepeak INOP and not wired to system. Provide proof of peration to Marine Inspector IAW 46 CFR 182.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2009
Resolution: O/O provided proof of operation of all Bilge High Level water alarms.
Documentation › Certificates/Documents › FCC SSL
Issued 18 June 2009 Resolved
Provide proof of FCC safety Cert and Ops permit for M/V Eclipse and new call sign IAW 47 CFR 13
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O provided proof of FCC safety Cert and Ops permit to satisfaction Marine Inspector.
Lifesaving › Lifefloat › Float Free
Issued 18 June 2009 Resolved
Life float covers label "Keep Clear". Remove Fish Pole rack from STBD cover IAW 46CFR185.604. Limited to carrying 24 Passengers until rack is removed.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O removed fish pole rack and labeled cover to keep items clear to satisfaction Marine Inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 June 2009 Resolved
Post call sign in pilot house for New Registration.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O posted new call sign to satisfaction MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 2009 Resolved
Replace float light on ring buoy IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O removed and replaced float light on ring buoy.
Lifesaving › Lifefloat › Serviceable
Issued 18 June 2009 Resolved
Repair holes in life float and label capacity from manufacture on life float on top pilot house.
Action required: 705 - Other - as specified
Due 24 February 2010
Resolved 24 February 2010
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 April 2009 Resolved
Label passenger capacity for second deck IAW stability letter.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O labeled passenger capacity for second deck to satisfaction marine Inspector.
Lifesaving › Lifefloat › Float-free Link
Issued 7 April 2009 Resolved
Install painter line and hydro release for life float atop pilot house IAW 46CFR180.130. Limit to 48 total persons onboard.
Action required: 705 - Other - as specified
Resolved 24 February 2010
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 7 April 2009 Resolved
Provide proof of windows in Pilot House meet Coast Guard Regs. Due to replacing Port, STBD, and Aft windows.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Resolution: O/O provided proof to satisfaction of Marine Inspector that all windows meet CG regs.
Engineering › Bilge Water Management System › Manifold
Issued 30 June 2008 Resolved
Label bilge manifold to be legible.
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 June 2008 Resolved
Doble clamp all water intake hoses on Port and Starbord Engines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Lifesaving › Hand Flares › Expired
Issued 30 June 2008 Resolved
Provide 6 red hand flares and 6 orange day smokes with current expiration dates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 30 June 2008 Resolved
Remove excessive oil from E/R Bilge
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Interface Detector
Issued 30 June 2008 Resolved
Prove proper operation of bilge high water alarm in lazerett.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Documentation › Certificates/Documents › Stability Letter
Issued 30 June 2008 Resolved
Post stability letter on bridge.
Due 4 July 2008
Resolved 2 July 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Strainer
Issued 8 February 2008 Resolved
Replace/install foot/strainer on bilge suction, accommodations, port side.
Due 8 February 2008
Resolved 12 February 2008
Construction/Loadline › Hull › Stringer
Issued 8 February 2008 Resolved
Install nut on stringer fastener where missing, accommodations, starboard side.
Due 8 February 2008
Resolved 12 February 2008
Construction/Loadline › Hull › Bottom Plating
Issued 8 February 2008 Resolved
Make vsl available for inspection once back in the water.
Due 8 February 2008
Resolved 12 February 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2007 Resolved
Provide additional (4) adult Type-1 PFDs, vessel is restricted to no more than 47 total persons until corrected.
Due 1 June 2007
Resolved 5 July 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 May 2007 Resolved
Provide US Coast Pilot, CG Light List, 2007 tide tables, and tidal current tables, or applicable extracts.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 May 2007 Resolved
[name withheld] stowage to reflect total number of adult lifejackets carried.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 May 2007 Resolved
Update first aid medications.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 May 2007 Resolved
Provide blanks for switchboard in E/R/
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 May 2007 Resolved
Provide/install SSB radio w/DSC capability, vessel is restricted to no more than 100NM from shore until provided.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 5 July 2007
Resolution: Owner elected not to install this equipment, amended COI to restrict vessel to not more than 100NM from shore.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 May 2007 Resolved
Secure line for the lifefloat waterlight (on top of wheelhouse) around the body of the lifefloat.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 May 2007 Resolved
Repair port remote fuel shut-off.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 18 May 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 18 May 2007 Resolved
Submit specs on galley hood fan, and ensure galley grease extraction hood meets 46 CFR 181.425 and CID Policy Letter #20.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 5 July 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2006 Resolved
Repair bilge alarms to show problems in individual compartments instead of all lighting at the same time.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2006 Resolved
Remove dead end wire leading from distribution panel and remove loose wire from pump to battery box from bilge space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 June 2006 Resolved
Remove toggles on emergency lighting to prevent them from being truned off or put in new system that comes on when there is a loss of power. Also, paint a Red E on each emergency light.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 2 June 2006 Resolved
Remove improper fuel hose that is being used as a sight glass. Provide proper way of sounding tank.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Engineering › Steering Gear System › Rudder Stock
Issued 2 June 2006 Resolved
Repair loose rudder stop on port side and provide proper backing stop on stbd side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 June 2006 Resolved
Provide a panel door to the distribution box in the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 June 2006 Resolved
Repair both emergency fuel shut off rods.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2006
Resolved 2 June 2006
Lifesaving › Hand Flares › Expired
Issued 2 June 2006 Resolved
Provide 1 hand held red flare.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 2 June 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 June 2006 Resolved
Provide chains for all watertight hatches on deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 June 2006 Resolved
Replace 11 adult kapok life jackets and 3 child kapok life jackets. Jackets were leaking air from sealed compartments.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 2 June 2006
Resolution: O/OP bought new single cell foam life jackets.
Lifesaving › Work Vest › Readily Accessible
Issued 2 June 2006 Resolved
Provide 60ft of line to a designated MOB rescue life jacket.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 30 June 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 May 2005 Resolved
Plug/seal aft engineroom bulkhead penetrations
Due 23 May 2005
Resolved 17 May 2005
Resolution: Bulkhead penetrations plugged with foam sealant.
Construction/Loadline › Structures › Scuttle
Issued 11 May 2005 Resolved
Provide captive device on lazarette scuttle
Due 23 May 2005
Resolved 17 May 2005
Resolution: New cable chain installed on scuttle.
Documentation › Markings/Placards › Capacity Marking
Issued 11 May 2005 Resolved
Mark upper deck with maximum passengers allowed
Due 23 May 2005
Resolved 17 May 2005
Resolution: New sign posted on upper deck to indicate the maximum passengers allowed.
Operations/Management › Pollution › Control of Garbage
Issued 11 May 2005 Resolved
Post waste management plan
Due 23 May 2005
Resolved 17 May 2005
Resolution: Waste management plan revised and posted.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 May 2005 Resolved
Provide updated pubs, tide/current tables, light list, coast pilot
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2005
Resolved 17 May 2005
Resolution: New tide, tidal current tables, light list, coast pilot pubs purchased.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 May 2005 Resolved
Correct hailing port to match COD
Due 11 June 2005
Resolved 17 May 2005
Resolution: Corrected hailing port from San Pedro to San Diego.
Electrical › Electric Generation Source (service) › Generator
Issued 11 May 2005 Resolved
Repair leaks generator SW pump and cooler housing
Due 23 May 2005
Resolved 17 May 2005
Resolution: Replaced generator pump with new pump.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 11 May 2005 Resolved
Secure/block batteries in boxes
Due 23 May 2005
Resolved 17 May 2005
Resolution: Installed wooden barriers inside battery box to secure batteries in place.
Engineering › Fuel Oil Service System › Valve
Issued 11 May 2005 Resolved
Repair inoperative port FO COV
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2005
Resolved 17 May 2005
Resolution: Replaced valve hinge assembly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 May 2005 Resolved
Provide updated contact info for EPIRB registration
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2005
Resolved 17 May 2005
Resolution: Owner information updated on EBIRB registry website to reflect the current owner/opr.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 May 2005 Resolved
Repair port stern tube leak at flex hose
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2005
Resolved 17 May 2005
Resolution: Sealed leak with foam sealant.
Electrical › Electrical Distribution System (service) › Switch
Issued 8 November 2004 Resolved
Replace switch housing for fresh water pump.
Due 8 December 2004
Resolved 9 December 2004
Resolution: Replaced switch housing for fresh water pump.
Communications › Radio Communications › EPIRB
Issued 8 November 2004 Resolved
Provide current EPIRB registration.
Action required: 705 - Other - as specified
Resolved 10 November 2004
Resolution: Provided completed EPIRB registration form although new sticker has not been received yet.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 8 July 2003 Resolved
System was in poor and unserviceable condition. Master is required to replace bottle/service existing system and provide report.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2003
Resolution: Servicing report received via fax.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 8 July 2003 Resolved
End piping on nozzle is missing a clean-out (at least 2")/capped extension in the engine room. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 6 August 2003
Resolution: clean-out installed
Lifesaving › Lifebuoys
Issued 8 July 2003 Resolved
Lifeline is rotted and should be replaced. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 6 August 2003
Resolution: line replaced
Lifesaving › Buoyant Apparatus
Issued 8 July 2003 Resolved
Waterlight on lifefloat is broken and should be repaired/replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 6 August 2003
Resolution: waterlight replaced
Accommodation/Occupational Safety › Ventilation
Issued 8 July 2003 Resolved
Vent louvers are clogged with excessive amounts of dirt/dust.
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 6 August 2003
Resolution: Vent louvers cleaned
Engineering › Bilge Water Management System
Issued 8 July 2003 Resolved
Engine room bilge pump is not mounted/secured. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 6 August 2003
Resolution: pump mounted
Electrical › Electrical Distribution System (service)
Issued 8 July 2003 Resolved
Galley breaker panel wires are plainly visible and arranged in a hazardous manner. Various breakers are missing labels or have poorly made labels. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 11 August 2003
Resolution: Panel arranged/re-wired safely.
Communications › Radio Communications
Issued 16 April 2002 Resolved
Fill-in blanks on emergency broadcast placard.
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 April 2002 Resolved
Remove unused pvc piping in penetration through bulkhead between engine room and bunkroom and make bulkhead watertight following removal.
Due 30 April 2002
Resolved 16 April 2002
Engineering › Fuel Oil Service System › Vent Pipe
Issued 16 April 2002 Resolved
Renew flames screens on fuel oil tank vents.
Due 30 April 2002
Resolved 16 April 2002
Accommodation/Occupational Safety › Ventilation
Issued 18 January 2002 Resolved
Install ventilation in lazarette compartment in accordance with 46 CFR 177.600.
Condition: Design Flaw
Due 18 March 2002
Resolved 16 April 2002
Electrical › Electrical Distribution System (service)
Issued 18 January 2002 Resolved
Install connection box for shore tie cable on vessel in accordance with 46 CFR 183.390. LEGACY COMPONENT DESC: Cable
Due 18 March 2002
Resolved 16 April 2002
Engineering
Issued 25 September 2001 Resolved
REPAIR ENGINE EXHAUST COOLING WATER PUMP ON STARBOARD M/E.
Condition: Unknown
Due 10 October 2001
Resolved 10 October 2001
Engineering
Issued 25 September 2001 Resolved
REPLACE RUBBER EXHAUST LINE FOR STARBOARD M/E DAMAGED DURING ENGINE ROOM FIRE.
Condition: Unknown
Due 10 October 2001
Resolved 10 October 2001
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 24 September 2001 Resolved
Repair cooling water pump for starboard M/E exhaust.
Condition: Unknown
Due 24 September 2001
Resolved 24 September 2001
Resolution: Pump impeller replaced and intake obstruction cleared.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 September 2001 Resolved
Repair rubber exhaust line damaged during engine room fire.
Condition: Unknown
Due 24 September 2001
Resolved 24 September 2001
Resolution: Exhaust line renewed.
Construction/Loadline
Issued 12 September 2001 Resolved
Repair hole in bow, above deck in bullworks.
Condition: Unknown
Due 12 September 2001
Resolved 13 September 2001
Fire Fighting
Issued 12 April 2001 Resolved
Relocate B-I fire extinguisher to bridge operating station.
Condition: Unknown
Due 11 May 2001
Resolved 22 May 2001
Electrical
Issued 12 April 2001 Resolved
Renew all "SO" "SOJ" and "SOW" electrical wiring throughout the AC electrical system. This requirement to be accommplished prior to the next hull exam.
Condition: Unknown
Due 31 January 2002
Resolved 18 January 2002
Resolution: Unapproved wiring in engine room replaced with cable meeting 46 CFR 183.340(d).
Accommodation/Occupational Safety
Issued 12 April 2001 Resolved
Label the passengers limit on 2nd deck.
Condition: Unknown
Due 11 May 2001
Resolved 22 May 2001
Lifesaving
Issued 12 April 2001 Resolved
Update vessel's first aid kit.
Condition: Unknown
Due 11 May 2001
Resolved 22 May 2001
Construction/Loadline
Issued 12 April 2001 Resolved
Raise the coaming on the machinery space weathertight access to a minimum of 12 inches.
Condition: Unknown
Due 26 January 2002
Resolved 18 January 2002
Resolution: Coaming raised to 12".
Construction/Loadline
Issued 12 April 2001 Resolved
Install bilge line In Accordance With (IAW) 46 CFR 182.510 for service to the forward peak compartment bilge.
Condition: Unknown
Due 11 May 2001
Resolved 19 April 2001
Documentation
Issued 12 April 2001 Resolved
Vessel's Master shall ensure the engineroom is inspected once every 30 minutes while passengers are on board. The results of each inspecion shallbe recorded in the ships log with the date, time and initials of the deckhand conducting the inspection.
Condition: Unknown
Due 18 April 2001
Resolved 22 May 2001
Fire Fighting
Issued 12 April 2001 Resolved
Repair as new installed fixed fire extinguishing system in way of engine room.
Condition: Unknown
Due 19 April 2001
Resolved 13 April 2001
Documentation
Issued 12 April 2001 Resolved
Provide proof of drug testing program for DAPI audit.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Navigation
Issued 26 April 2000 Resolved
REPAIR AS NEW AND PROVE PROPER OPERATION OF THE THE PORT HYDRAULIC STEERINGRAM.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000 Resolved
UPDATE FIRST AID KIT.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Engineering
Issued 26 April 2000 Resolved
REPAIR AS NEW AND PROVE PROPER OPERATION OR THE STARBOARD FUEL SHUT OFF VALVE.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Fire Fighting
Issued 26 April 2000 Resolved
INSTALL A GREASE EXTRACTION HOOD OVER GALLEY GRIDDLE AND BROILER IN ACCORDANCE WITH 46 CFR 181.400 AND 181.425.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Fire Fighting
Issued 26 April 2000 Resolved
REPAIR AS NEW AND PROVE PROPER OPERATION OF THE FIXED FIRE EXTINGUISHING SYSTEM ENGINE SHUT DOWNS.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Engineering
Issued 14 April 1999 Resolved
Remove and cap off supply fitting on unused fuel pressure switch on port propulsion engine.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 14 April 1999 Resolved
Provide a set of operating instructions for installed fixed fire system.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Engineering
Issued 14 April 1999 Resolved
Install new flame screens in port and starboard fuel tank vents.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 14 April 1999 Resolved
Install bilge high level alarm in forepeak compartment.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 14 April 1999 Resolved
Install a strainer over bilge suction in lazzarette.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Engineering
Issued 14 April 1999 Resolved
Replace existing non-approved worn fuel supply and discharge hoses on port and starboard propulsion engines with Coast Guard approved hose and fittings.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 14 April 1999 Resolved
Conduct post installation test of installed fixed extinguishing system in the presence of attending marine inspector.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Lifesaving
Issued 14 April 1999 Resolved
Replace weak links.
Condition: Unknown
Due 15 April 1999
Resolved 16 April 1999
Fire Fighting
Issued 14 April 1999 Resolved
Install approved smoke detectors in overnight accomadation space.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 14 April 1999 Resolved
Fabricate ventilation closure devices for engine room.
Condition: Unknown
Due 5 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 14 April 1999 Resolved
Prior to carrying more than 49 persons provide proof of adequate subdivision in accordance with 46 CFR 171.040 (a)(1).
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Engineering
Issued 20 January 1999 Resolved
SUBMIT PROPOSAL TO REPAIR AS NEW F/O TANK IN WAY OF TANK BOTTOM
Condition: Unknown
Due 5 February 1999
Resolved 5 February 1999
Construction/Loadline
Issued 14 May 1997 Resolved
Repair the starboard side aft engineroom bulkhead.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Documentation
Issued 14 May 1997 Resolved
Update charts.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 14 May 1997 Resolved
Conduct emergency drills with the local Coast Guard inspector on board.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 14 May 1997 Resolved
Replace batteries in the life jacket lights as per 180.75.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 14 May 1997 Resolved
Remove wire nut throughout the vessel.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 6 May 1996 Resolved
Provide 4 additional Coast Guard approved type 1 adult lifejackets prior tocarring more than 44 adults.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Documentation
Issued 17 August 1994 Resolved
Provide proof of documentation.
Condition: Unknown
Due 1 November 1994
Resolved 24 October 1994
Accommodation/Occupational Safety
Issued 29 May 1992 Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD MSD HOLDING TANKS THEN PROVIDEPROOF THAT TANKS HAVE BEEN TESTED IN ACCORDANCE WITH 33 CFR 159.109.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Documentation
Issued 29 May 1992 Resolved
PROVIDE PROOF OF VALID DOCUMENTATION REFLECTING NEW OWNER.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Documentation
Issued 29 May 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Lifesaving
Issued 8 May 1992 Resolved
PROVIDE PROPER CLASS "A" EPIRB WITH MANUFACTURE DATE ON OR AFTER OCTOBER 1988.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Documentation
Issued 8 May 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47CFR80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Unknown
Issued 8 June 1990 Resolved
PROVIDE CERTIFICATION THAT REPLACEMENT CARPETS TO BE INSTALLED FOR THE PILOT HOUSE ARE COAST GUARD APPROVED.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Navigation
Issued 3 May 1989 Resolved
PROVIDE NAVIGATION SOUNDING DEVICE OR HORN IN GOOD CONDITION.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
REPLACE HOUSE WIRE TO THE HOT WATER HEATER WITH APPROVED MARINE TYPE CABLE.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
PROVIDE GROUND WIRES TO THE PORT AND STBD. FUEL TANK FILL AND VENT PIPES.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Unknown
Issued 3 May 1989 Resolved
PROVIDE DOUBLE CLAMPS TO BAIT TANK DISCHARGE PIPE IN WAY OF LAZARRETE.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
PROVIDE ONE ADDITIONAL HAND-HELD RED FLARE TO TOTAL 6 FLARES.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 28 April 1988 Resolved
PROVIDE CURRENT COPIES OF LIGHT LIST, TIDE TABLES, AND T-BOAT REGS.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Navigation
Issued 28 April 1986 Resolved
PROVIDE 8 INCH BELL
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Navigation
Issued 28 April 1986 Resolved
PROVIDE COMPASS DEVIATION CARD
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Engineering
Issued 28 April 1986 Resolved
PROCURE FLAME SCREEN ON PORT FUEL TANK VENT
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Fire Fighting
Issued 28 April 1986 Resolved
PROVIDE HAND HELD FIRE PUMP
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Lifesaving
Issued 28 April 1986 Resolved
PROCURE 2 CG APPROVED ADULT PFD WITH LIGHTS
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Electrical
Issued 28 April 1986 Resolved
ELEMINATE ON OFF SWITCH ON BUNK ROOM EMERGENCY LIGHTS
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Construction/Loadline
Issued 3 December 1985 Resolved
CROP BACK TO GOOD MATERIAL AND TREAT AREA WHICH SHOWS ANY EVIDENCE OF MARINE BORER INFESTATION.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985

Casualty record · 5

28 April 2002Routine · role: Involved in a Marine Casualty · activity 1611251
21 September 2009Routine · role: Involved in a Marine Casualty · activity 3647968
2 July 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4640749
7 January 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6080696
9 August 2017Routine · role: Involved in a Marine Casualty · activity 6242916
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CAT SPECIAL (2002), ECLIPSE (2009–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.