TOMAHAWK

TOMAHAWK is a 1980 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2016, most recently in March 2026, along with 70 deficiencies — 1 with no resolution recorded —, 1 operational control and 5 casualty investigations between 2002 and 2017.

Records from 2002 to 2026. Most recent: inspection, 12 March 2026.

Built
1980
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 March 2026
…with no type recorded3
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK3596
Flag
UNITED STATES
Maury page id
psix-51208

Documentation record

Registered dimensions (L × B × D)61.6 ft × 22.2 ft × 7.5 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT C FLETCHER · HERMOSA BEACH, CA, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 70 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 other recorded names, with years; 5 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

12 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8310323
3 December 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8277165
16 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8112713
18 November 2024 Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8036729
15 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8019440
4 August 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7980545
14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912514
28 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7871516
16 January 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7849859
25 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7785568
7 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646879
23 May 2022 Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457262
2 April 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504033
23 September 2021 Damage Survey · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7319123
21 September 2021 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7317578
10 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7221308
10 June 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6972968
23 January 2020 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6894613
6 December 2019 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6868703
11 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6832800
8 April 2019 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6653973
5 September 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6533370
9 July 2018 Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6473270
4 January 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332607
6 December 2017 Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317775
9 August 2017 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6235696
9 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6242916
25 July 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6220589
20 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6181319
7 January 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080696
19 September 2016 Type not recorded
No type recorded · USCGC ASPEN (WLB 208) · USCG Arctic District (CGD-A) · Activity 6018774
13 April 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5853734

Deficiency record · 70

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 March 2026 Resolved
Expired 2/26
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 28 April 2026
Resolution: Vessel provided photo of an active COD to CG inspector via email.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 March 2026 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 26 March 2026 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 12 March 2026 Resolved
FCC Marine Radio Operator Permit missing
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received proof owner/operator obtained his Marine Radio Operator Permit.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 12 March 2026 Resolved
Failed to conduct and document monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received photograph of log containing record of monthly EPIRB test.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 March 2026 Resolved
No light for magnetic compass
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 March 2026 Resolved
Sound producing device broken.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 March 2026 Resolved
Missing 3 red flares
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 March 2026 Resolved
Incorrect labeling of max passengers on top side deck (states 0 correct number is 8)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 March 2026 Resolved
Portable lights missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 March 2026 Resolved
Fire alarm system not interconnected IAW IFR.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 March 2026 Resolved
Missing outlet covers and overhead electrical cables need to be supported.
Condition: Improper/Lack of Maintenance
Due 26 March 2026
Resolved 1 April 2026
Resolution: SSD received photograph showing that the covers were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2026 Resolved
Bilge pumps in forward peak inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2026
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 January 2026 Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers. 46CFR177.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2026
Resolution: egress drills complete, no issues found.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2025 Resolved
Provide proof of drug and alcohol program enrollment for all employees who have a safety sensitive position on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Received updated crew enrollment list.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Provide unused engine room fuel tank sight glass with threaded caps on valves to prevent accidental leaks if valves were to open.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Recieved photos of capped valves.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Prove proper operation of failed port side fuel shutoff valve. -Prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 17 April 2025
Resolution: Repairs made, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2025 Resolved
Prove proper operation of inoperable bilge pump. -Prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 17 April 2025
Resolution: Repair to air leak found, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2025 Resolved
Provide generator / shore power breakers with interlock device to prevent both breakers being energized simultaneously.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2025
Resolution: Recieved photo of device installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2024 Resolved
Only two crew members are listed on the vessel's DAPI program for 2024. Update crew list with DAPI program's drug consortium.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Other crew members were drug tested and entered into the vessel's DAPI program.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2024 Resolved
Large openings in the aft bulkhead of the engine room prevent the space for being adequately vapor tight for the fixed fire fighting system. Seal the open bulkhead penetrations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Holes were sealed with plywood and foam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
A battery charger in the engine room was cracked open and had an unauthorized temporary repair in place. Remove/replace the damaged battery charger. To be rectified by 28 May 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: Battery charger was removed and a new one has been ordered.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 May 2024 Resolved
FCC Radiotelephony Safety Certificate was expired. Acquire a new FCC Radiotelephony Safety Certificate. To be rectified by 13 June 2024. Cite: 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 16 May 2024
Resolution: A new cert was issued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Power cables were laying in bilge of the engine room. Some of the affected cables were improperly dead-ended. Install the affected cables as high as practicable above the bilge, and remove or properly dead-end all dead end wires in junction boxes or with pressure type connectors. To be rectified by 28 May 2024. Cites: 46 CFR 183.05-50(a)(Old-T) & 46 CFR 183.05-50(b)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: Power cables were re-routed above the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Light switch at entrance to engine room is missing its faceplate. Replace the affected faceplate. To be rectified by 28 May 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 16 May 2024
Resolution: A new faceplate was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024 Resolved
Port MDE fuel pump was leaking excessively. Repair/replace the affected fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2024
Resolution: Pump was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2024 Resolved
Vessel failed to receive CG Drydock and Internal structure exam as reflected on the Certificate on Inspection. Complete Drydock and Internal Structure Exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Completed Drydock exam
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023 Resolved
Vessel does not have evidence of DAPI enrollment. Provide documentary evidence of enrollment in an appropriate drug and alcohol testing program.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2023
Resolution: Vessel operator sent in paperwork from ASTS proving enrollment in DAPI program.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 March 2023 Resolved
Vessel's EPIRB is not appropriately registered. Update EPIRB registration with NOAA. Vessel is restricted to a Lakes, Bays, and Sounds route until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 10 March 2023
Resolution: Received email with new registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Engine room hot water heater: cable connector not properly installed; Repair.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Generator wiring conductor spliced with wire nut; Repair with proper mechanical sealed splice. 46CFR183.200 (b) 16C
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
STBD side forward of Main Engine Fresh water pump end bell cover missing; Install cover.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2022 Resolved
Portside Accommodation forward HVAC unit wiring spliced with wire nuts; Install approved electrical Junction box for wiring termination.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 23 May 2022 Resolved
Galley griddle unit electrical power connection not properly sealed; Repair.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2022
Resolution: Received Picture of corrected item.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 September 2021 Resolved
Based on the structural failure and a review of the history of similar failures on the vessel, the OCMI has questioned the structural adequacy of the vessel. Prior to returning to service, you must prove the structural adequacy of the vessel by submitting plans and calculations which demonstrate compliance with the standards established by a recognized classification society to the Marine Safety Center for approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2021
Resolved 1 December 2021
Resolution: Vessel underwent plan review w/ collaboration of naval architect and MSC to bring vessel into Lloyds wood vessel rules structural standards.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 September 2021 Resolved
46 CFR 176.600 (d) Whenever damage to hull plating or structural members may affect the seaworthiness of a vessel is discovered or suspected, OCMI may conduct an internal structural examination in any affected space and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permenant repairs. Starboard bow suffered significant damage to include delamination of outer sheets. In forepeak - observed multiple deck support beams to be rotted and the forwardmost transverse frame fractured. Vessel is required to undergo full ISE and drydock examination to asses damage and affect repairs prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2021
Resolved 1 December 2021
Resolution: Vessel underwent new plan review w/ MSC after it was found the structure did not comply with applicable wood boat rule set and experienced multiple structural failures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2021 Resolved
Port and Starboard remote shut-off rods to the main fuel valves from fuel tank were seized and sheared. Must replace or install new remote means to shut off fuel valves prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Corrected on spot
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2021 Resolved
Must install modular smoke detector in salon area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 26 June 2021
Resolution: Verified smoke detector was installed - [name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 June 2021 Resolved
Forward Bulkhead penetrations need to be made water/vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 2 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Generator Racor filter is missing flame bowl. Must provide fire resistant bowl.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 28 June 2021
Resolution: Verified flame bown installed - [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 10 June 2021 Resolved
Must clean the fuel out of the port/stbd main engine racor bowls.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2021 Resolved
Must install chains on all exposed deck hatches. Hatch covers to lazzerette space missing chain.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 June 2021 Resolved
Must properly mount starboard light fixture in the lazzerette space.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 June 2021 Resolved
Must fix leak on the raw water intake for the generator at the elbow section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 8 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Must properly mount the bilge pump motor to prevent damage to the pump system.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on spot
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 June 2021 Resolved
Provide lagging gear or install mounting bracket on cooling water marine hose to prevent contact with the turbo charger on the port main engine.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Rectified on Spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020 Resolved
Life jacket light batteries were installed backwards. Correct light batteries on all life jackets and verify proper operation.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Install escape lighting in passenger berthing area in way of emergency escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 11 October 2019
Resolution: Light installed & tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 October 2019 Resolved
Install smoke detector in galley space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Installed & tested.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 11 October 2019 Resolved
Remove rug from emergency escape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Rug was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Secure switch and cover 12V electrical equipment in passenger berthing below stair cases.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Switch and cover was secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 October 2019 Resolved
Remove combustible waste cans from galley area.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Replaced with metal can.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Repair galley outlet cover behind coffee maker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Cover was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Repair insulation for galley feeder cable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 11 October 2019
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Terminate dead-end wire in way of steering pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 6 December 2019
Resolution: Wire was terminated.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 October 2019 Resolved
Remove fuel oil from bilge and tank top.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2019
Resolved 11 October 2019
Resolution: Cleaned bilges and tank top.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2019 Resolved
Replace tank sight glass and valves with non-combustible sight glass (guarded to prevent damage) and quick closing valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2019
Resolved 6 December 2019
Resolution: Sight glass and valves were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 January 2020
Resolved 30 January 2020
Resolution: A/C 1-line dwg provided, review completed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 July 2018 Resolved
Prove proper operation of the bilge high water alarm system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: All alarms operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2018 Resolved
Properly mount electric gray/black water pumps to foundations.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Pumps secured to foundation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2018 Resolved
Provide 5 adult type 1 PFDs (operations restricted to 50 adult persons).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Lifejackets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 July 2018 Resolved
Install captive chains on hatches exposed to weather.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 7 August 2018
Resolution: Captive devices installed.
Construction/Loadline › Hull › Side Shell
Issued 10 August 2017 Resolved
Remove all damaged hull materials to good hull/structure and make ready for Coast Guard Inspectors.
Condition: Damaged By Earlier Event
Due 3 January 2018
Resolved 16 August 2017
Construction/Loadline › Hull › Side Shell
Issued 10 August 2017 Resolved
Provide a list of materials and plans for repair for Coast Guard approval. All repairs to be completed using the guidance from NVIC 7-95 or better.
Condition: Damaged By Earlier Event
Due 3 January 2018
Resolved 16 August 2017
Construction/Loadline › Hull › Side Shell
Issued 9 August 2017 Resolved
Haul out vessel for a damage survey by CG Marine Inspectors.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2017
Documentation › Certificates/Documents › Stability Letter
Issued 20 June 2017 Resolved
Provide a stability letter prior to ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2017
Resolved 5 July 2017
Resolution: Provided a stability letter prior to ops.
Documentation › Logs/Records › Drug Test Records
Issued 20 June 2017 Resolved
Provide DAPI program prior to OPS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provided DAPI program prior to OPS
Lifesaving › Hand Flares › Quantity
Issued 20 June 2017 Resolved
Provide 6 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provide 6 red hand flares.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 20 June 2017 Resolved
Provide secure mount for the SSDG exhaust system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Provided secure mount for the SSDG exhaust system.
Construction/Loadline › Structures › Deck Plating
Issued 20 June 2017 Resolved
Make permanent repairs stbd main deck fwd on the house on the main deck where the repairs are incomplete.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Make permanent repairs stbd main deck fwd on the house on the main deck where the repairs are incomplete.
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2017 Resolved
Make permanent/approved repair to the port hull in the engine room where there's evidence of saltwater intrusion & rot.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 10 July 2017
Resolution: Made permanent/approved repair to the port hull in the engine room where there's evidence of saltwater intrusion & rot.

Casualty record · 5

28 April 2002Routine · role: Involved in a Marine Casualty · activity 1611251
21 September 2009Routine · role: Involved in a Marine Casualty · activity 3647968
2 July 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4640749
7 January 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6080696
9 August 2017Routine · role: Involved in a Marine Casualty · activity 6242916
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CAT SPECIAL (2002), ECLIPSE (2009–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.