This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
848 - Regulatory (Subpart C or D), Gross Ton
848 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-51294
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Starboard stern corner wrapper has a fracture of about 2' 6" long by 1/8" wide from deck down. Gouge and weld area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 28 August 2009
Resolution: Fracture gouged and re-weld, air tested SAT.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 12 August 2009Resolved
Draft marks on all four corners are worn. Repaint with contrasting color.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 28 August 2009
Resolution: Draft marks painted.
Pollution Prevention/Response › Prevention Equipment › Emergency Control Systems (tank barges)
Issued 12 August 2009Resolved
Sign for Emergency Shut down for prime mover is worn. Paint or replace.
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 28 August 2009
Resolution: Sign installed
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 12 August 2009Resolved
Flame screen on the vent pipe on diesel tank for prime mover has a hole. Replace flame screen.
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 28 August 2009
Resolution: Flame screen installed
Deck/Cargo › Cargo Stowage › General
Issued 12 August 2009Resolved
Clean and test #3 starboard void for possilble leak from cargo tank.
Action required: 705 - Other - as specified
Due 11 September 2009
Resolved 28 August 2009
Resolution: 2" fracture located and repaired in the # 3 cargo tank, stbd side approx. 10'' fwd of aft bulkhead, 2" up. Repair airtested SAT
Deck/Cargo › Cargo Heating › General
Issued 2 April 2007Resolved
Pin hole in steam pipe in #2 and #3 port wing void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2007
Resolved 4 May 2007
Resolution: TT104 fixed and tested steam coils.
Replace cargo header valves with rising stem valves by next cargo tank internal examination. LEGACY COMPONENT DESC: Closure Devices
Condition: Placed in Improper Service
Due 7 May 2006
Resolved 26 May 2006
Resolution: Valves installed and a satisfactory hydro test completed.
Deck/Cargo
Issued 28 June 1999Resolved
Provide proof of testing of cargo pressure gauge.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Deck/Cargo
Issued 28 June 1999Resolved
Provide proof of cargo pump relief valve testing.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Construction/Loadline
Issued 7 May 1996Resolved
GAUGE AND REWELD PORT SIDE VERTICAL SEAMS BUTT WELDS FOR #2 W/T 20' AFT, #3W/T 10' AFT AND 10' FWD, AND #5 W/T JUST AFT. STBD SIDE, #2 W/T 20' AFT, #3 W/T 10' AFT, AND #5 W/T JUST AFT.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Construction/Loadline
Issued 7 May 1996Resolved
CROP AND RENEW STARBOARD BILGE KNUCKLE AND PLATE AREA NEAR AFT END OF #2 WING VOID TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Deck/Cargo
Issued 20 August 1992Resolved
CONDUCT ANNUAL HYDROSTATIC TEST OF CARGO TRANSFER PIPING.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Construction/Loadline
Issued 24 September 1991Resolved
GOUGE AND WELD 10 INCH CRACK IN WAY OF FWD PORT KNUCKLE ON WRAPPER.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991