SUN RIVER

SUN RIVER is a 1979 industrial vessel. The Coast Guard has recorded 58 inspections since 1982, most recently in October 2018, along with 59 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 1992 and 2010.

Records from 1982 to 2018. Most recent: inspection, 15 October 2018.

Built
1979
Last inspected
15 October 2018
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7819682 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE6902
Flag
UNITED STATES
338366000, 338600000 (licence lapsed)
Maury page id
psix-51343

Inspections, by type

…with no type recorded11
…past their stated due date2
Years with a record 29 calendar years (1982–2018)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)188.6 ft × 44.0 ft × 15.0 ft
Registered tonnagegross 292 / net 198
ITC dimensions (L × B × D)188.6 ft × 44.0 ft × 15.0 ft
ITC tonnagegross 1,039 / net 311
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it292 - Regulatory (Subpart C or D), Gross Ton
1039 - Convention (Subpart B), Gross Ton
198 - Regulatory (Subpart C or D), Net Ton
311 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE6902MMSI 338366000 · expired · compulsorily equipped · granted 2 December 2008, cancelled 16 February 2019
WCX7671MMSI 338600000 · expired · compulsorily equipped · granted 22 December 1999, cancelled 1 December 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENSCO 89 Mobile Offshore Drilling Unit · MISLE 54225 · 30 August 1998 · activity 68536ENSCO 89 Mobile Offshore Drilling Unit · MISLE 54225 · 4 June 1998 · activity 90080MARGIE ANN Commercial Fishing Vessel · MISLE 78272 · 15 March 1994 · activity 176731

Inspection history · 58

15 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6561831
24 September 2018 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6548237
9 August 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6235364
12 June 2017 Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6173679
6 July 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5932715
23 July 2015 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5193691
23 January 2012 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4426500
1 September 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4132778
4 February 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3939067
13 January 2010 Annual Inspection · Ballast Water Examination · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3663084
7 January 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3662523
14 December 2007 Administrative Inspection · MTSA Verification · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3380803
16 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586325
17 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950245
24 January 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1734779
26 November 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445904
5 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068039
9 February 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1059793
9 January 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382104
13 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049203
7 December 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381750
12 April 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122389
30 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 68536
17 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130774
26 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372289
4 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90080
2 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786338
21 May 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424415
15 August 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380644
27 November 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 655856
25 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188671
23 August 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187914
10 August 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195246
19 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877235
13 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187220
19 May 1995 Examination of Repairs · Damage Survey · COI Inspection · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453055
15 March 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 176731
7 February 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377112
15 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 84840
1 June 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1152195
6 May 1993 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1134836
14 July 1992 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468267
28 May 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 126330
10 March 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945710
2 October 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942812
25 June 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221086
6 May 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 900849
8 March 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 985170
21 September 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1011300
5 May 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1351973
10 March 1988 MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338891
14 May 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031794
13 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024515
16 September 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007794
13 March 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999082
29 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989948
16 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975703
12 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963979

Deficiency record · 59

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 September 2018 Resolved
Insufficient illumination provided by the emergency lighting, not providing enough light for safe egress in passageway by engine space. Provide sufficient lgiht to allow for egress.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 15 October 2018
Resolution: Emergency lighting installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2018 No resolution recorded
Alternative Security Plan did not have a valid approval letter from Marine Safety Center. Resubmit plan for approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2018 No resolution recorded
Alternative Security Plan has not been audited annually. Conduct audit upon security plan approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 9 August 2017 Resolved
STEERING GEAR ROOM DOOR INOPERABLE & REQUIRES MANTENANCE FOR WATERTIGHT INTEGRITY. 46 CFR 92.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2017
Resolution: Ensured operation of door to meet required watertight integrity. All was satisfactory.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 9 August 2017 Resolved
PERIODIC AUTOMATION TEST REPORT NOT DONE IAW AUTOMATION TEST PROCEDURES. OIL SHUTDOWNS INOP. 46 CFR 61.40-6(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 6 September 2017
Resolution: AUTOMATION TESTS WERE PROPERLY CONDUCTED IAW AUTOMATED TEST PROCEDURES
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 August 2017 Resolved
EXHAUST LAGGING ON #2 SSDG MISSING; REQUIRES REPLACEMENT. 46 CFR 58.10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 6 September 2017
Resolution: LAGGING INSTALLED
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 August 2017 Resolved
VESSE; NEEDS TO CONDUCT DRILLS WITH PROPER NUMBER OF MARINERS PER CURRENT COI. 46 CFR 97.15-35
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 September 2017
Resolution: FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS CONDUCTED TO SATISFACTION
Construction/Loadline › Hull › Side Shell
Issued 26 June 2017 Resolved
BASED OFF OF FINDINGS & OVERALL CONDITION OF THE VSL, ENSURE DRYDOCK IS CONDUCTED TO EXAMINE HULL TO SATISFACTION OF ATTENDING MARINE INSPECTOR AND PRIOR TO OPERATIONS. 46 CFR 91.40-3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 6 July 2017
Resolution: Vessel completed drydock
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 23 July 2015 Resolved
Rader was not functioning properly 46CFR 96.25
Due 7 August 2015
Resolved 28 July 2015
Resolution: Radar replaced. Observed satisfactory operation of radar.
Stability › Watertight Integrity › General
Issued 5 January 2009 Resolved
Vessel has 6 dawg door going from engine room to steering compartment. Vessel shall install Quick Acting Water Tight Door in place of 6-dawg door. Item shall be completed at next Hull exam.
Due 5 January 2012
Resolved 18 February 2013
Electrical › Lighting (emergency)
Issued 26 November 2001 Resolved
Repair or renew two inoperable emergency lighting fixtures located in the main machinery space. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 26 November 2001
Resolved 26 November 2001
Lifesaving › Inflatable Liferafts
Issued 26 November 2001 Resolved
Provide documentation that each inflatable liferaft has been serviced as required by 46 CFR 133.45.
Action required: 705 - Other - as specified
Due 26 November 2001
Resolved 26 November 2001
Resolution: Both liferafts were sent to New Orleans, Louisiana for servicing but were replaced a board the vessel with two Coast Guard approval inflatable liferafts. Reviewed proper documentation of servicing and testing of liferafst by a CG approved facility.
Lifesaving › Line-Throwing Appliances
Issued 26 November 2001 Resolved
Provide a line-throwing appliance auxiliary line of at least 500ft long with a breaking strength of at least 9,000 pounds-force and if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet as required by 46 CFR 133.170. LEGACY COMPONENT DESC: Lines
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2001
Resolved 26 November 2001
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 November 2001 Resolved
Provide satisfactory evidence of the servicing of portable B-II fire extinguishers located in the main machinery space as required by 46 CFR 132.350.
Action required: 705 - Other - as specified
Due 26 November 2001
Resolved 26 November 2001
Resolution: A qualified servicing facility was called out to perform the required inspections and maintenance of the B-II fire extinguishers in the main machinery space as per 46 CFR 132.350. All portable fire extinguishers were properly serviced and verified.
Electrical
Issued 9 January 2001 Resolved
DO NOT OPERATE #3 SHIPS SERVICE GENERATOR UNTIL REVERSE POWER RELAY IS REPAIRED/REPLACED. REPAIRS TO BE COMPLETED NLT 09FEB01 TO THE SATISFACTIONOF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 February 2001
Resolved 19 March 2001
Documentation
Issued 23 August 1995 Resolved
PROVIDE TO THE ATTENDING MARINE INSPECTOR A COPY APPROVED BY THE MARINE SAFETY CENTER OF THE TANK SOUNDING TABLES SHOWING CORRECT TANK USAGE.
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Documentation
Issued 19 June 1995 Resolved
PROVIDE TO THE ATTENDING MARINE INSPECTOR A COPY APPROVED BY THE MARINE SAFETY CENTER VIA ABS OF THE REVISION OF THE DRAWING NO. 94-660-01 SHOWING_x001C_CORRECT TANK ARRANGEMENT.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Documentation
Issued 19 June 1995 Resolved
PROVIDE TO THE ATTENDING MARINE INSPECTOR A COPY APPROVED BY THE MARINE SAFETY CENTER IF THE TANK SOUNDING TABLES SHOWINF CORRECT TANK USAGE.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Documentation
Issued 19 June 1995 Resolved
PROVIDE TO THE ATTENDING MARINE INSPECTOR A COPY APPROVED BY THE MARINE SAFETY CENTER OF THE PRELIMINARY STABILITY ANALYSIS SHOWING CURRENT TANK USAGE.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Deck/Cargo
Issued 19 June 1995 Resolved
PROVIDE ONBOARD A COPY OF THE OIL TRANSFER PROCEDURES THAT INCLUDES ALL CARGOES.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Documentation
Issued 19 May 1995 Resolved
SUBIT REVISED COPY TO THE MARINE SAFETY CENTER OF TANK SOUNDING TABLES SHOWING CORRECT TANK USAGE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Deck/Cargo
Issued 19 May 1995 Resolved
PROVIDE ONBOARD A COPY OF THE OIL TRANSFER PROCEDURES THAT INCLUDES ALL_x001C_ CARGOES.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
PLACE ONBOARD VESSEL DOCUMENTATION.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
PLACE ONBOARD CURRENT STABILITY LETTER.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
PLACE ONBOARD COPY OF COAST GUARD LIGHT LIST.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
PLACE ONBOARD FCC STATION LICENSE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
PLACE ONBOARD CURRENT COASTAL PILOT PUBLICATION.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
PRIOR TO PLACING VESSEL IN SERVICE, PROVIDE EVIDENCE OF A PROPERLY ADJUSTEDMAGNETIC COMPASS.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
SUBMIT REVISED COPY TO THE MARINE SAFETY CENTER OF THE PRELIMINARY STABILITY ANALYSIS SHOWING CURRENT TANK USAGE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Documentation
Issued 19 May 1995 Resolved
SUBMIT TO THE MARINE SAFETY CENTER VIA ABS A REVISION OF DRAWING _x001C_ NO. 94-660-01 SHOWING CORRECT TANK ARRANGEMENT.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Accommodation/Occupational Safety
Issued 19 May 1995 Resolved
POST ONBOARD WASTE MANAGEMENT PLAN IAW 33 CFR 151.57.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Deck/Cargo
Issued 6 May 1993 Resolved
PROVIDE MANUFACTURE DATA FOR DRYBULK TANKS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Construction/Loadline
Issued 6 May 1993 Resolved
REPAIR REACH ROD CONNECTION TO FORPEAK VALVE CONTROL.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
PROPERLY CONNECT ELECTRICAL WIRE JUNCTION BOX ON WATER PURIFICATION SYSTEM.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Deck/Cargo
Issued 6 May 1993 Resolved
PRESSURE TEST AND PROPERLY STENCIL FUEL TRANSFER HOSES.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 6 May 1993 Resolved
REPAIR GOOSE NECK VENT ON STARBOARD DAY TANK.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
PROVIDE GLOBES/GUARDS ON MACHINERY SPACE LIGHTING.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Construction/Loadline
Issued 6 May 1993 Resolved
RENEW VENTS FOR NUNBER 1 AND 2 STARBOARD BALLAST TANKS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Lifesaving
Issued 6 May 1993 Resolved
INSTALL VENT COVERS FOR COOLER SPACE ON PORT SIDE.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Deck/Cargo
Issued 6 May 1993 Resolved
REPAIR HAND RELIEVING GEAR ON PORT AIR RECIEVER RELIEF VALVE.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Accommodation/Occupational Safety
Issued 6 May 1993 Resolved
REPAIR INSIDE REEFER DOOR HANDLE AND TEST FOR PROPER OPERATION.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Navigation
Issued 6 May 1993 Resolved
MAINTAIN UP TO DATE NOTICE TO MARINERS AND CHARTS WITH CORRECTION NOTED ON CHARTS.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
PROVIDE EMERGENCY LIGHT TO ILLUMINATE GENERATOR CONTROLS/SWITCHBOARD.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
RENEW FLEX OIL LINE TO GOVERNOR FILTER ON #1 AND 2 SERVICE GENERATOR.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Electrical
Issued 6 May 1993 Resolved
INSTALL APPROVED FLEX FUEL LINE ON FUEL OIL FILTER #1 GENERATOR.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 2 October 1991 Resolved
PROVIDE SUITABLE CONTAINMENT FOR FUEL OIL TRANSFER SYSTEM ON THE MAIN DECK. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1991
Resolved 21 October 1991
Engineering
Issued 2 October 1991 Resolved
MAKE READY FOR INSPECTION AND GAS FREE #3 FUEL OIL TANK, #4 P/S FUEL OIL TANK AND FUEL OIL DAY TANKS P/S IN ORDER TO COMPLETE INTERNAL STRUCTURAL EXAM IAW 46CFR91.43._x001C_ _x001C_
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Construction/Loadline
Issued 2 October 1991 Resolved
AIRTEST IN THE PRESENCE OF A MARINE INSPECTOR INSERTS INSTALLED IN #1 P/S BROMIDE TANKS AND #2/S BROMIDE TANK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Deck/Cargo
Issued 2 October 1991 Resolved
MAKE READY FOR INSPECTION STARBOARD ANCHOR. ANCHOR PRESENTLY NOT ONBOARD DURING INITIAL INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Unknown
Issued 2 October 1991 Resolved
COMPLETE ITEMS ON ENCLOSED WORKLIST DTD 20AUG91._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Deck/Cargo
Issued 2 October 1991 Resolved
MAKE READY FOR INSPECTION (CLEAN AND GAS-FREE) ALL DRY MUD TANKS 1-6 FOR MARINE INSPECTOR TO EXAMINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Engineering
Issued 6 May 1991 Resolved
REPAIR ENGINE SHUT DOWNS ON BRIDGE.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Fire Fighting
Issued 6 May 1991 Resolved
REPLACE FIRE PUMP PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991 Resolved
REPLACE LIFEFLOAT WITH AN APPROVED RESCUE BOAT.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Construction/Loadline
Issued 6 May 1991 Resolved
REPLACE MAIN DECK ESCAPE HATCH COVER FROM ENGINEROOM.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Construction/Loadline
Issued 6 May 1991 Resolved
STENCIL EMERGENCY EXIT KEEP CLEAR ON ALL ESCAPE EXITS.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Electrical
Issued 16 September 1986 Resolved
PROVIDE A REP FLASHING LT IN THE GENERATOR SPACE TO OPERATE WHEN THE GENERAL ALARM BELL IS SOUNDED. GENERATOR SPACE BEING TOTALLY SEPARATE FOR THE MACHINERY SPACE. 46CFR113.25-10.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986
Electrical
Issued 16 September 1986 Resolved
INSTALL MACHINERY GUARDS ON THE 3 SHIPS SERVICE GENERATORS IN THE GENERATORSPACE.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986
Unknown
Issued 13 March 1986 Resolved
REPAIR THE RUDDER ANGLE DIRECTOR, SHAFT TACHE, HEAT SENSOR ABOVE THE STBD MAIN DIESEL ENGINE AND THE ENGINEROOM SOUND POWER PHONE. COMPLIANCE DATE IS 13APR86.
Condition: Unknown
Due 13 March 1986
Resolved 13 March 1986

Casualty record · 2

28 May 1992Major Marine Casualty · role: Involved in a Marine Casualty · activity 126330
7 January 2010Routine · role: Involved in a Marine Casualty · 1 dead · activity 3662523
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.