MAURY USCG vessel records
← All vessels

SUN RIVER

SUN RIVER is a 1979 industrial vessel. The Coast Guard has recorded 5 inspections since 2016, most recently in October 2018, along with 8 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 1992 and 2010.

Records from 1992 to 2018. Most recent: inspection, 15 October 2018.

Built
1979
Last inspected
15 October 2018
Documentation
No Operation - PM · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 October 2018
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7819682
WDE6902
Flag
UNITED STATES
Maury page id
psix-51343

Documentation record

Registered dimensions (L × B × D)188.6 ft × 44.0 ft × 15.0 ft
Registered tonnagegross 292 / net 198
ITC dimensions (L × B × D)188.6 ft × 44.0 ft × 15.0 ft
ITC tonnagegross 1,039 / net 311
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it292 - Regulatory (Subpart C or D), Gross Ton
1039 - Convention (Subpart B), Gross Ton
198 - Regulatory (Subpart C or D), Net Ton
311 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

15 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6561831
24 September 2018 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6548237
9 August 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6235364
12 June 2017 Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6173679
6 July 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5932715

Deficiency record · 8

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 September 2018 Resolved
Insufficient illumination provided by the emergency lighting, not providing enough light for safe egress in passageway by engine space. Provide sufficient lgiht to allow for egress.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 15 October 2018
Resolution: Emergency lighting installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2018 No resolution recorded
Alternative Security Plan did not have a valid approval letter from Marine Safety Center. Resubmit plan for approval.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2018 No resolution recorded
Alternative Security Plan has not been audited annually. Conduct audit upon security plan approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 9 August 2017 Resolved
STEERING GEAR ROOM DOOR INOPERABLE & REQUIRES MANTENANCE FOR WATERTIGHT INTEGRITY. 46 CFR 92.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2017
Resolution: Ensured operation of door to meet required watertight integrity. All was satisfactory.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 9 August 2017 Resolved
PERIODIC AUTOMATION TEST REPORT NOT DONE IAW AUTOMATION TEST PROCEDURES. OIL SHUTDOWNS INOP. 46 CFR 61.40-6(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 6 September 2017
Resolution: AUTOMATION TESTS WERE PROPERLY CONDUCTED IAW AUTOMATED TEST PROCEDURES
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 August 2017 Resolved
EXHAUST LAGGING ON #2 SSDG MISSING; REQUIRES REPLACEMENT. 46 CFR 58.10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 6 September 2017
Resolution: LAGGING INSTALLED
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 August 2017 Resolved
VESSE; NEEDS TO CONDUCT DRILLS WITH PROPER NUMBER OF MARINERS PER CURRENT COI. 46 CFR 97.15-35
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 September 2017
Resolution: FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS CONDUCTED TO SATISFACTION
Construction/Loadline › Hull › Side Shell
Issued 26 June 2017 Resolved
BASED OFF OF FINDINGS & OVERALL CONDITION OF THE VSL, ENSURE DRYDOCK IS CONDUCTED TO EXAMINE HULL TO SATISFACTION OF ATTENDING MARINE INSPECTOR AND PRIOR TO OPERATIONS. 46 CFR 91.40-3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 6 July 2017
Resolution: Vessel completed drydock

Casualty record · 2

28 May 1992Major Marine Casualty · role: Involved in a Marine Casualty · activity 126330
7 January 2010Routine · role: Involved in a Marine Casualty · 1 dead · activity 3662523
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.