MAURY USCG vessel records Sign in
← All vessels

ENSCO 89

ENSCO 89 is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 99 inspections since 1982, most recently in July 2016, along with 97 deficiencies and 4 casualty investigations between 2002 and 2006.

Records from 1982 to 2016. Most recent: inspection, 1 July 2016.

Built
1982
Last inspected
1 July 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753823 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-54225

Inspections, by type

…with no type recorded38
Years with a record 29 calendar years (1982–2016)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4670 - Convention (Subpart B), Gross Ton
1401 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GENESIS PATRIOT Towing Vessel · MISLE 439637 · 19 November 2004 · activity 2246192THE DUCHESS Commercial Fishing Vessel · MISLE 51902 · 25 May 2002 · activity 1628004SUN RIVER Industrial Vessel · MISLE 51343 · 30 August 1998 · activity 68536SUN RIVER Industrial Vessel · MISLE 51343 · 4 June 1998 · activity 90080

Inspection history · 99

1 July 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5925802
13 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3690351
16 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3345857
15 May 2007 In-Service Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2930948
21 September 2006 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2783978
29 September 2005 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2509354
19 November 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246192
29 October 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2231051
30 September 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2215546
14 September 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2220274
4 August 2004 Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2155757
6 January 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1976123
3 November 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1941077
6 October 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1922173
24 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825394
5 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825305
29 January 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1741352
11 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1717461
22 November 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1720429
22 October 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1693922
5 September 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1671336
26 August 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666751
25 May 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1628004
21 March 2002 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495767
20 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478056
14 September 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1071878
21 August 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370340
27 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822453
8 August 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463609
10 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050347
16 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820498
2 February 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1045585
26 November 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454741
20 September 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1034874
25 August 1999 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444206
5 February 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 174227
23 December 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808101
17 November 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 805244
3 September 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802613
30 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 68536
14 August 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436112
7 July 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794099
4 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90080
18 January 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 107069
21 November 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 774107
27 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388363
12 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786526
19 August 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409737
7 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097022
17 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093270
6 September 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1267729
22 August 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451094
2 August 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1095307
25 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765075
17 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 203349
15 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880806
4 December 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874213
7 September 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424144
9 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 876437
15 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 162049
13 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 697751
8 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 120263
4 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102240
14 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865920
12 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 702973
12 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 864373
27 September 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422425
1 September 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411018
4 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127943
21 December 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1160020
22 November 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 846828
13 November 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 90976
28 October 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 830628
7 October 1993 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 827531
20 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693349
9 December 1992 Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393882
29 September 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382500
29 July 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120493
13 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102656
22 October 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 936893
28 November 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 923362
9 October 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912184
12 February 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227099
30 October 1989 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931331
2 May 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887878
2 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209654
29 November 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209014
12 October 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888020
14 October 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023797
8 May 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030070
4 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323100
15 October 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018035
2 October 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302346
12 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292197
11 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975304
16 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285437
8 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278711
25 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280140
22 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964774

Deficiency record · 97

Construction/Loadline › Hull › Bottom Plating
Issued 4 August 2004 Resolved
COMPLETE PHASE II OF SEILOD EXAM SWIM BY OF LEG TO SPUD CAN CONNECTIONS NLT 2NOV2004.
Condition: Unknown
Due 2 November 2004
Resolved 23 September 2004
Resolution: Phase II completed via report from ENSCO dated 23Sep04.
Lifesaving › Lifebuoys
Issued 6 October 2003 Resolved
Replace life ring on starboard aft main deck. (Ring #8)
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 October 2003
Fire Fighting › Nozzles
Issued 6 October 2003 Resolved
Repair / maintain all fire fighting nozzles.
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 7 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 October 2003 Resolved
Remove drinking fountains in hazardous locations or prove safe for intended area. LEGACY COMPONENT DESC: Spark Producing Device
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 18 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 6 October 2003 Resolved
Repair forklift and prove proper operation.
Action required: 705 - Other - as specified
Due 6 October 2003
Resolved 18 February 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 6 October 2003 Resolved
Provide system diagram on fixed halon system.
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 18 February 2004
Fire Fighting › Firemans Outfit
Issued 6 October 2003 Resolved
Provide complete fire fighters' ensemble to cover all exposed skin. LEGACY COMPONENT DESC: Protective Clothing
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 18 February 2004
Lifesaving › Inflatable Liferafts
Issued 6 October 2003 Resolved
Remove or service life rafts for increased manning iaw ammended COI valid until 01 Nov 03.
Action required: 705 - Other - as specified
Due 7 November 2003
Resolved 18 February 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 November 2002 Resolved
Shaker area and drill floor electrical new and existing installations are not IAW Regulations. Wire runs and junction boxes are not properly mounted creating an emergency egress problem.
Condition: Improper Installation
Due 29 November 2002
Resolved 27 November 2002
Deck/Cargo
Issued 21 August 2001 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION OR CONDUCT NDT ON #1,#2 BARITE, #3,#4 CEMENT DRY BULK TANKS, AND DRILL FLOOR RECEIVER. INCLUDE ORIGINAL SCANTLINGS WITH NDT REPORT.
Condition: Unknown
Due 21 August 2001
Resolved 21 August 2001
Engineering
Issued 21 August 2001 Resolved
INSTALL MISSING FLAME SCREENS ON VENT FOR HYDRAULIC OIL TANK AND INSTALL CAP ON FUEL NOZZEL ON MAIN DECK.
Condition: Unknown
Due 21 August 2001
Resolved 21 August 2001
Lifesaving
Issued 8 August 2000 Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Electrical
Issued 8 August 2000 Resolved
MOUNT J-BOXES THROUGHOUT RIG AS NOTED DURING COAST GUARD INSPECTION. REPAIRPENETRATIONS ON LOGGING SHACKS. REMOVE DEAD END WIRING IN E-GEN SHACK.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 8 August 2000 Resolved
REPAIR HOSE RACK AT FIRE STATION #12. PROVIDE NEW LINE FOR LIGHT TO LIFE RING ATTACHMENT ON LIFE RING UNDER RADIATORS. PROPERLY SECURE SPARE FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Lifesaving
Issued 8 August 2000 Resolved
RENEW MAIN VIEWING WINDOW, HAVE BREATHING AIR BOTTLES HYDRO'D AND RENEW BROKEN SECTION OF LIFE LINE ON #2 LIFEBOAT.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Fire Fighting
Issued 8 August 2000 Resolved
CROP AND RENEW WASTED SECTIONS OF FIREMAIN, UPON COMPLETION HYDRO TO 1.5 MAWP, HYDRO TO BE WITNESSED BY A COAST GUARD MARINE INSPECTOR OR ABS SURVEYOR.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Unknown
Issued 25 August 1999 Resolved
COMPLETE PHASE II OF THE THE SELOID.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Unknown
Issued 25 August 1999 Resolved
CROP AND RENEW WASTED HANDRAILS ON THE MAIN DECK.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Unknown
Issued 25 August 1999 Resolved
PROVE PROPER OPERATION OF THE OIL WATER SEPARATOR.
Condition: Unknown
Due 25 October 1999
Resolved 27 September 1999
Unknown
Issued 25 August 1999 Resolved
MAKE REPAIRS TO DISCHARGE LINE #2 FIRE MAIN.
Condition: Unknown
Due 25 October 1999
Resolved 27 September 1999
Unknown
Issued 25 August 1999 Resolved
VERIFY PROPER OPERATION OF RELIEF FIREMAIN.
Condition: Unknown
Due 25 October 1999
Resolved 27 September 1999
Unknown
Issued 25 August 1999 Resolved
RENEW FLEXIBLE HOSE, MAIN FIREMAIN TO CANTILEVER FIREMAIN.
Condition: Unknown
Due 25 October 1999
Resolved 27 September 1999
Unknown
Issued 3 September 1998 Resolved
SUBMIT REPAIR PROPOSAL FOR DAMAGE TO THE PORT JACKUP LEG TO THE [name withheld], COMPLETE REPAIRS AS PER ABS DIRECTION AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Lifesaving
Issued 14 August 1998 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Construction/Loadline
Issued 27 September 1997 Resolved
SUBMIT DIVE COMPANY REPORT AND VIDEO OF NDT EXAM AND UNDERWATER SWIM-BY OF SPUD CANS TO [name withheld].
Condition: Unknown
Due 27 September 1997
Resolved 27 September 1997
Construction/Loadline
Issued 19 August 1997 Resolved
RENEW WASTED OVERHEAD IN SHAKER HOUSE.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Fire Fighting
Issued 19 August 1997 Resolved
MAKE GALLEY DOORS SELF-CLOSING AND AUTO LATCHING.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Unknown
Issued 19 August 1997 Resolved
REPLACE WASTED OR MISSING BILGE SUCTION STRAINER BASKETS IN PRE-LOAD TANKS #2, 3, 8, 9, 15, 21A, 22A, 22B, AND 28.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 19 August 1997 Resolved
RENEW WASTED SAFETY RAILINGS AS NECESSARY.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 19 August 1997 Resolved
RENEW GRATING OVER BILGE WELLS: NEXT TO MSD, AND IN PUMP ROOM.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Fire Fighting
Issued 19 August 1997 Resolved
ARREST CORROSSION ON FIREMAIN SYSTEM AS NECESSARY, RENEW SECTION WITH DOUBLER IN CEMENT ROOM, RENEW SECTIONS WITH PAD WELDING REPAIRS AT FIRE PUMP AND AT FIRE STATION #9.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Construction/Loadline
Issued 19 August 1997 Resolved
REPAINT DRAFT MARKS AND LOADLINE.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Unknown
Issued 19 August 1997 Resolved
MAKE CORRECTION TO POLICY PER REVISIONS TO 46CFR109 AS CONTAINED IN FEDERALREGISTER, VOL. 61, NO. 98 OF 20MAY96.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Documentation
Issued 19 August 1997 Resolved
PROVIDE APPROVALS FOR CANTILEVER EXTENSION AND OPERATIONS MANUAL REVISION TO [name withheld],
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Construction/Loadline
Issued 19 August 1997 Resolved
RENEW GASKETS FOR PRE-LOAD TANK HATCHES.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Construction/Loadline
Issued 19 August 1997 Resolved
CONDUCT NON-DISTRUCTIVE EXAMINATION OF LEG-TO-CAN CRITICAL CONNECTIONS TO THE SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Construction/Loadline
Issued 19 August 1997 Resolved
RENEW DUMP VALVE IN PRE-LOAD TANK #16.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Construction/Loadline
Issued 6 September 1996 Resolved
REPLACE FRAMES & DOORSSS TO MUD PIT ROOM (GAS TIGHT, SELF-CLOSING)
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Electrical
Issued 6 September 1996 Resolved
REPLACE CONTROLLER FOR ABT, EMERGENCY GENERATOR & PERFORM SATISFACTORY ABT TEST.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Lifesaving
Issued 22 August 1996 Resolved
Conduct lifeboat weight tests to the satisfaction of attending CG Inspector.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Engineering
Issued 22 August 1996 Resolved
Replace air receiver on drill floor or hydrostatically test to 1 1/4 X M.A.W.P.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Fire Fighting
Issued 7 September 1995 Resolved
Submit comprehensive report of annual fire extinguisher servicing including: Halon and fixed CO2 system cylinder weights, tests conducted, i.e. sirens, pressure activated shutdown, time delay, etc.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Documentation
Issued 7 September 1995 Resolved
Submit construction plans and details of EXXON installed portable berthing container to OCMI showing compliance with the structural fire protection requirements of 46 CFR Subchapter I-A. Confer with CID for additional guidance.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Documentation
Issued 7 September 1995 Resolved
Submit plans and details for installation of foam deluge system to OCMI forapproval per 46 CFR 107.305. In addition, the Fire Control Plan and Operating Manual should be amended and resubmitted reflecting installation of foam system.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Electrical
Issued 7 September 1995 Resolved
Repair and prove proper operation of #1 generator low lube oil pressure shutdown.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Lifesaving
Issued 27 September 1994 Resolved
Repair fire sprinkler system on lifeboat nr 2 (port) to provide adequate pressure and spray coverage.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Construction/Loadline
Issued 1 September 1994 Resolved
Complete Hull (topside) portion of SEILODD including: examination of barge bottom, all voids, preload tanks, drill water tanks, through-hull sea valves and dump valves.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Unknown
Issued 1 September 1994 Resolved
Provide copies of underwater video tapes on leg/can connection mag-particletesting on all three legs.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 1 September 1994 Resolved
Complete annual servicing of fixed Halon system by third party authorized servicing facility and provide CG with complete report of same.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Electrical
Issued 7 October 1993 Resolved
REMOVE WIRE NUTS ON EMERGENCY LIGHT IN BATTERY CHARGING MODULE IN PORT STORAGE.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Fire Fighting
Issued 7 October 1993 Resolved
MAKE PERMANENT REPAIRS TO FIRE STATION #4 HOSE VALVE.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Fire Fighting
Issued 7 October 1993 Resolved
PROVIDE SERVICEALBE FIRE EXT FOR FORKLIFT.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Fire Fighting
Issued 7 October 1993 Resolved
PROVIDE DOCUMENTATION THAT PORTABLE O2/LEL METER FOR FIREMAN OUTFIT HAS BEEN CALIBRATED AND RETURNED TO VESSEL.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Lifesaving
Issued 7 October 1993 Resolved
REPLACE LIFELINE ON AT LEAST 02 LIFERINGS ON OPPOSITE SIDES OF THE VESSEL.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Lifesaving
Issued 7 October 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Lifesaving
Issued 7 October 1993 Resolved
PROVIDE DUPLICATE MANUFACTURE'S PLACARD FOR FORKLIFT.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Engineering
Issued 7 October 1993 Resolved
MAKE PERMANENT REPAIRS OF FUEL OIL LEAKS ON THE BLACKMER HAND PUMPS ON THE#1 AND #3 SERVICE GENERATORS.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Lifesaving
Issued 7 October 1993 Resolved
PROVIDE DOCUMENTATION THAT 02 FIRST AID KITS HAVE BEEN PURCHASED AND PLACEDABOARD BOTH LIFEBOATS.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Engineering
Issued 7 October 1993 Resolved
MAKE PERMANENT REPAIR TO FUEL LEAKS AT OUTLET SIDE OF FUEL FILTER ON # 1 SERVICE GENERATOR.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Engineering
Issued 7 October 1993 Resolved
DEMONSTRATE OPERATION OF EMERGENCY GENERATOR LOW OIL PRESSURE SHUT DOWN.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Engineering
Issued 7 October 1993 Resolved
MAKE PERMANENT REPAIR TO FUEL LEAK IN 1 1/4" HORIZONTAL LINE AT THE SUCTIONSIDE OF #2 FUEL TRANSFER PUMP.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Engineering
Issued 7 October 1993 Resolved
PROVIDE AND MARK FORKLIFT FUELING AREA.
Condition: Unknown
Due 21 October 1993
Resolved 28 October 1993
Deck/Cargo
Issued 29 September 1992 Resolved
REPLACE ALL NON-APPROVED RELIEF VALVES WITH APPROVED ONES.
Condition: Unknown
Due 29 September 1992
Resolved 29 September 1992
Lifesaving
Issued 9 October 1990 Resolved
IN THE PRESENCE OF CG INSPECTOR, LOWER, RELEASE AND OPERATE BOTH LIFEBOATS IN THE WATER AND PROVE PROPER OPERATION OF WATER SPRAY SYSTEM.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Construction/Loadline
Issued 30 October 1989 Resolved
COMPLETE AT NEXT RIG MOVE BUT NO LATER THAN 23FEB90: MAKE PERMANENT REPAIRS TO SIX INCH CRACK ON STARBOARD LEG, OUTBOARD CHORD WEB ATTACHMENT OF THE LOWER CAN TO THE GUIDE PLATE. CRACK EXTENDS FROM TOPOF WELD, DOWNWARD.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Unknown
Issued 12 October 1988 Resolved
RESUBMIT FIRE CONTROL PLAN TO REFLECT INSTALLATION OF AFFF FOAM FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
REPLACE GASKETS ON NUMBER TWO BOAT SIDE HATCHES (ONE EACH ON PORT AND STBD SIDE).
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
SUBMIT PROPOSAL FOR THE INSTALLATION OF "18" CAGES ON JACKING LEG PLATFORM VERTICAL LADDERS (SIX ON EACH LEG). PLATFORMS ARE 22' FROM MAIN DECK.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
INSTALL BELL FOR GENERAL ALARM SYSTEM IN MUB PITS.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
REPLACE GENERAL ALARM POWER PANEL FUSES WITH 250 VOLT TYPE IN LIEU OF 600 VOLT FUSES INSTALLED.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
STAINLESS STEEL WIRE BANDS ON HEXANE CABLES IN THE MUD PIT NEED TO BE 5/8" IN WIDTH VICE 1/8" TO 3/16" WHICH ARE CURRENTYLY INSTALLED.(IEEE-45)
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988 Resolved
PROVE PROPER OPERATION OF COMBUSTIBLE GAS INDICATOR LOCATED ON DRILL FLOOR (AND PURGE ALARM ON SAME). LOGGERS COMBUSTIBLE GAS INDICATOR TO REMAIN IN OPERATION UNTIL REPAIR IS EFFECTED.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Documentation
Issued 15 October 1986 Resolved
PROVIDE ONBOARD AN APPROVED CONSTRUCTION PORTFOLIO PER 46 CFR 107.305 (LL).
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 15 October 1986 Resolved
PROVIDE THE BREATHING AIR BOTTLES IN THE PORT AND STBD LIFEBOATS WITH THE REQUIRED AIR PRESSURE, 46 CFR 108.503.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 15 October 1986 Resolved
PROVIDE LIFEBOAT FLOODLIGHTS FOR ILLUMINATION AT LIFEBOAT STATIONS #1 AND #2 PER 46 CFR 111.175-16.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 15 October 1986 Resolved
PROVIDE ON BOARD THE REQUIRED BARREL CLEANING EQUIPMENT FOR THE LINE THROWING APPLIANCE PER 46 CFR 160.031.4(E).
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 15 October 1986 Resolved
REPLACE THE BREATHING TUBE ON THE SELF-CONTAINED BREATHING APPARATUS LOCATED IN THE CONTROL ROOM PER 46 CFR 108.497.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Lifesaving
Issued 15 October 1986 Resolved
REPAIR OR REPLACE GASKET, FIND PORT DOOR, ON STBD LIFEBOAT, 46 CFR 108.503.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Unknown
Issued 16 October 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 89 DN652440
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Electrical
Issued 16 October 1984 Resolved
REMOVE ALL OF THE BRASS FITTINGS FROM THE FUEL OIL DAY TANKS. 46CFR107.231.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Construction/Loadline
Issued 16 October 1984 Resolved
RENEW THE BROKEN WINDOWN PANE LOCATED ON THE AFTER BULKHEAD OF THE CONTROL HOUSE.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Construction/Loadline
Issued 16 October 1984 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATIONS OR PROVIDE EVIDENCE THAT PRESENT EQUIPMENT MEETS THE REQUIREMENTS; THE MUD PIT AND DRILL FLOOR MOTOR CONTROLLERS. 46CFR111.92.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Electrical
Issued 16 October 1984 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION THE DRILL FLOOR LIGHTING PANELS OR PROVIDE EVIDENCE THAT THE PRESENT EQUIPMENT MEETS THE REQUIREMENTS. 46CFR111.92.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Accommodation/Occupational Safety
Issued 16 October 1984 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE DRILL FLOOR AIR RECEIVEER AND TEST THE RELIEF VALVE. 46CFR61.10.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Electrical
Issued 16 October 1984 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION THE DRILL FLOOR GENERAL ALARM LIGHT AND BELL. CFR111.92.
Condition: Unknown
Due 16 October 1984
Resolved 16 October 1984
Lifesaving
Issued 25 October 1983 Resolved
PROVIDE ONE AUXILLARY LINE FOR LINE THROWING GUN; 1500 FT WITH A 9000 LB BREAKING STRENGTH. 46 CFR 108.497
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Navigation
Issued 25 October 1983 Resolved
PROVIDED 2 BLACK BALL DAY SHAPES, 1 DIAMOND DAY SHAPE AND 1 AFT ANCHOR LIGHT 33 CFR 87.
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Unknown
Issued 25 October 1983 Resolved
CONTACT ABS TO CHANGE LOADLINE CERTIFICATE TO REFERENCE THE PERMENANT STAB-ILITY LETTER ISSUED 2 JUNE 1983
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Electrical
Issued 25 October 1983 Resolved
PROVIDE A GENERAL ALARMS SIGNAL IN THE MUD PIT ROOM AND DEMONSTRATE SATISFACORY OPERATION.
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Electrical
Issued 25 October 1983 Resolved
MAKE THE BEDE MULTIGAS DETECTOR (TECHNICRAFT MODEL G-DM) AND ALARMS SAFE FOR USE IN A CLASSIFIED AREA. 46 CFR 111.80-5.
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Accommodation/Occupational Safety
Issued 25 October 1983 Resolved
REPLACE RELIEF VALVES ON THE SERVICE AIR SYSTEM; SETTING ON RELIEF VALVES NOT TO EXCEED THE SYSTEM MAWP OF 150 PSIG. 46 CFR 54. 15-10 (A).
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Construction/Loadline
Issued 25 October 1983 Resolved
PROVIDE AN "A-CLASS" CLOSURE FOR THE EMERGENCY GENERATOR ROOM INTAKE. 46 CFR 108.132.
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Construction/Loadline
Issued 25 October 1983 Resolved
PROVIDE AN APPROVED OPERATING MANUAL FIRE CONTROL PLAN, AND HAZAROUS LOCATION PLAN ABOARD THE VESSEL. 46 CFR 109.121, 107.305 AND 107.305 (VV)
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Unknown
Issued 25 October 1983 Resolved
PROVIDE WIND DIRECTION INDUCATOR FOR HELO-DECK (WING SOCK).
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Unknown
Issued 25 October 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE PENROD 89, DN652440.
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Fire Fighting
Issued 25 October 1983 Resolved
PROVIDE ANNUAL SERVICING CERTIFICATE FOR FIXED FIREFIGHTING SYSTEMS BOARD RIG (46 CFR 107.231) (K)
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983
Fire Fighting
Issued 25 October 1983 Resolved
REPAIR OXYGEN SENSOR FOR O2 METER FOR FIREMAN'S OUTFIT LOCATED IN ENGINE ROOM. 46 CFR 108.497
Condition: Unknown
Due 25 October 1983
Resolved 25 October 1983

Casualty record · 4

25 May 2002Routine · role: Involved in a Marine Casualty · activity 1628004
29 January 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1741352
14 September 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2220274
29 November 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2842973
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.