Records from 2002 to 2025. Most recent: inspection, 3 September 2025.
Documentation record
Registered dimensions (L × B × D)154.0 ft × 40.0 ft × 13.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)154.0 ft × 40.0 ft × 13.0 ft
ITC tonnagegross 608 / net 182
BuilderUNIVERSAL IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 September 2025 · expires 31 August 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it608 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
182 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
3 September 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8226285
18 March 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8095576
20 November 2024
Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8037664
13 November 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7824084
27 October 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7585093
15 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7507452
31 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7503794
24 August 2021
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7291335
19 November 2020
Inclining Experiment · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099209
18 March 2020
Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6931880
18 June 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6744813
28 March 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6651031
20 March 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375279
16 June 2017
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6177714
20 March 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108207
13 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6087650
16 August 2016
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5975095
7 July 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5933314
31 March 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5844753
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025
Resolved
(a) In a space described in § 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal. Red flashing light was inoperable. Repair within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2025
Resolved
Vessels over 180 feet in length which are not passenger vessels, and which operate on international voyages or in ocean, coastwise, or Great Lakes service, must be provided with a direct emergency bilge suction from any pump in the machinery space, except that a required bilge pump may not be used. The discharge capacity of the pump selected must exceed the capacity of the required main bilge pump and the area of the suction inlet is to be equal to the full suction inlet of the pump. MI could not verify suction, make suitable arrangements to witness test within 14 days
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation of bilge suction
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025
Resolved
The lantern must be relay-controlled so that the loss of normal power causes the lanterns to light. Engine room
light and main deck lights were not working. Rectify
within 14 days
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 September 2025
Resolved
The registers issued in connection with cargo gear certification must have all required entries fully completed as of the dates indicated, shall be kept current, and shall include the following:
Certification of the testing and examination of cranes, hoists, and their accessory gear;
Obtain new load test and wire fall certificate prior to the operation of the deck crane.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 11 December 2025
Resolution: Daryl Ryan sent proof of load test to MSU Texas City inbox.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 September 2025
Resolved
(a) When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work must be done under the cognizance of the Officer in Charge Marine Inspection. It must be done in accordance with the regulations in effect at the time such vessel or installation was contracted for or built (whichever is latest), or in accordance with the regulations in effect for new construction. Firemain had 02 pinhole leaks on pipe in engineroom. Rectify prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed new section of pipe and tested the fire pump. No leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2023
Resolved
Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Port fuel shut off valve was observed inoperable. Repair valve to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the port remote fuel shutoff valve.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 13 November 2023
Resolved
The movement of the indicator pointer shall be consistent with the movement of the steering wheel or control. MI observed the emergency steering rudder angle indicator inoperable from the emergency steering station. Repair angle indicator to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the local steering station rudder angle indicator.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 October 2022
Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. At exposed peripheries of the freeboard and superstructure decks, the rails shall be at least three courses, including the top.
Marine Inspectors identified significant wastage on the STBD side bridge wing ladder well.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022
Resolved
All emergency lights shall be marked with a letter "E" at least 1/2 inch high. Marine Inspectors identified three (03) emergency light fixtures to be missing the required marking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022
Resolved
The emergency lighting and power loads listed in this section shall include lighting for passageways, stairways, and escape trunks in passenger quarters, crew quarters, public spaces, machinery spaces and work spaces, adequate to permit passengers and crew readily to find their way to open decks. Marine Inspectors identified six emergency lighting fixtures to not be illuminated during emergency lighting test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 October 2022
Resolved
A stability booklet must be prepared for each vessel and must be approved by the Coast Guard Marine Safety Center. "Stability Calculations for the RMS CITATION" booklet marked "Examined" by Coast Guard Marine Safety Center referenced in the vessel's Stability Letter shall be kept on-board and available for inspection at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 March 2019
Resolved
Vessel is required to have a steering system which indicates at the primary operating station the position of the rudder. MIs discovered that none of the rudder position indicators matched. This includes the indicators on the bridge, as well as on the jockey bar in the steering room.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 9 April 2019
Resolution: Rudder angle indicators now in sync.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 13 February 2017
Resolved
Vsl owener has let ILLC expire. ABS has placed vessel on their layup vessel status. Issued CG-835 restricting vessel to operations inside of the boundary line due to expired Load Line Certificate. Owner's plan is to request via ABS and complete Load Line surveys at next dry dock period commencing 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 20 March 2018
Resolution: verifed vsl has valid loadline cert.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 7 July 2016
Resolved
Vsl's crew was unable to demonstrate over speed shut down for either MDE. Prove proper operation of the over speed shutdown device for both MDEs.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 16 August 2016
Resolution: Both MDE overspeed trips verified operational, to include shutdowns from the bridge.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2016
Resolved
Vessel's fire/safety control plan was displayed but not legible. Also needs to be updated to reflect current equipment installed on board.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Fire and safety plan stampled approved.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 July 2016
Resolved
Companies Drug and Alcohol written policy was not accurate with regard to federal requirements for when to test and reporting. Crew was not knowledgeable of the testing requirements.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Reviewed Drug and Alcohol written policy and found it sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 July 2016
Resolved
Life raft embarkation station did not have adequate emergency lighting. Add emergency lights as required by 46 CFR 199.150(f)(6).
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified adequate emergency lighting at the embarkation station.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 7 July 2016
Resolved
Provide proper documentation proving satisfactory testing of the vessel fire detection system. 3rd party cert did not mention engine room heat detectors.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified satisfactory third party report which attested to properly operating vessel fire detection system.