RMS CITATION

RMS CITATION is a 1980 offshore supply vessel. The Coast Guard has recorded 19 inspections since 2016, most recently in September 2025, along with 18 deficiencies and 1 casualty investigation in 2002.

Records from 2002 to 2025. Most recent: inspection, 3 September 2025.

Built
1980
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8033584
WDG5250
Flag
UNITED STATES
Maury page id
psix-51358

Documentation record

Registered dimensions (L × B × D)154.0 ft × 40.0 ft × 13.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)154.0 ft × 40.0 ft × 13.0 ft
ITC tonnagegross 608 / net 182
BuilderUNIVERSAL IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 September 2025 · expires 31 August 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it608 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
182 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

3 September 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8226285
18 March 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8095576
20 November 2024 Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8037664
13 November 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7824084
27 October 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7585093
15 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7507452
31 March 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7503794
24 August 2021 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7291335
19 November 2020 Inclining Experiment · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099209
18 March 2020 Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6931880
18 June 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6744813
28 March 2019 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6651031
20 March 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375279
16 June 2017 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6177714
20 March 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108207
13 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6087650
16 August 2016 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5975095
7 July 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5933314
31 March 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5844753

Deficiency record · 18

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025 Resolved
(a) In a space described in § 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal. Red flashing light was inoperable. Repair within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2025 Resolved
Vessels over 180 feet in length which are not passenger vessels, and which operate on international voyages or in ocean, coastwise, or Great Lakes service, must be provided with a direct emergency bilge suction from any pump in the machinery space, except that a required bilge pump may not be used. The discharge capacity of the pump selected must exceed the capacity of the required main bilge pump and the area of the suction inlet is to be equal to the full suction inlet of the pump. MI could not verify suction, make suitable arrangements to witness test within 14 days
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation of bilge suction
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025 Resolved
The lantern must be relay-controlled so that the loss of normal power causes the lanterns to light. Engine room light and main deck lights were not working. Rectify within 14 days
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 September 2025 Resolved
The registers issued in connection with cargo gear certification must have all required entries fully completed as of the dates indicated, shall be kept current, and shall include the following: Certification of the testing and examination of cranes, hoists, and their accessory gear; Obtain new load test and wire fall certificate prior to the operation of the deck crane.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 11 December 2025
Resolution: Daryl Ryan sent proof of load test to MSU Texas City inbox.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 September 2025 Resolved
(a) When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work must be done under the cognizance of the Officer in Charge Marine Inspection. It must be done in accordance with the regulations in effect at the time such vessel or installation was contracted for or built (whichever is latest), or in accordance with the regulations in effect for new construction. Firemain had 02 pinhole leaks on pipe in engineroom. Rectify prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed new section of pipe and tested the fire pump. No leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2023 Resolved
Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Port fuel shut off valve was observed inoperable. Repair valve to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the port remote fuel shutoff valve.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 13 November 2023 Resolved
The movement of the indicator pointer shall be consistent with the movement of the steering wheel or control. MI observed the emergency steering rudder angle indicator inoperable from the emergency steering station. Repair angle indicator to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the local steering station rudder angle indicator.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 October 2022 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. At exposed peripheries of the freeboard and superstructure decks, the rails shall be at least three courses, including the top. Marine Inspectors identified significant wastage on the STBD side bridge wing ladder well.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022 Resolved
All emergency lights shall be marked with a letter "E" at least 1/2 inch high. Marine Inspectors identified three (03) emergency light fixtures to be missing the required marking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022 Resolved
The emergency lighting and power loads listed in this section shall include lighting for passageways, stairways, and escape trunks in passenger quarters, crew quarters, public spaces, machinery spaces and work spaces, adequate to permit passengers and crew readily to find their way to open decks. Marine Inspectors identified six emergency lighting fixtures to not be illuminated during emergency lighting test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 October 2022 Resolved
A stability booklet must be prepared for each vessel and must be approved by the Coast Guard Marine Safety Center. "Stability Calculations for the RMS CITATION" booklet marked "Examined" by Coast Guard Marine Safety Center referenced in the vessel's Stability Letter shall be kept on-board and available for inspection at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 March 2019 Resolved
Vessel is required to have a steering system which indicates at the primary operating station the position of the rudder. MIs discovered that none of the rudder position indicators matched. This includes the indicators on the bridge, as well as on the jockey bar in the steering room.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 9 April 2019
Resolution: Rudder angle indicators now in sync.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 13 February 2017 Resolved
Vsl owener has let ILLC expire. ABS has placed vessel on their layup vessel status. Issued CG-835 restricting vessel to operations inside of the boundary line due to expired Load Line Certificate. Owner's plan is to request via ABS and complete Load Line surveys at next dry dock period commencing 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 20 March 2018
Resolution: verifed vsl has valid loadline cert.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 7 July 2016 Resolved
Vsl's crew was unable to demonstrate over speed shut down for either MDE. Prove proper operation of the over speed shutdown device for both MDEs.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 16 August 2016
Resolution: Both MDE overspeed trips verified operational, to include shutdowns from the bridge.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2016 Resolved
Vessel's fire/safety control plan was displayed but not legible. Also needs to be updated to reflect current equipment installed on board.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Fire and safety plan stampled approved.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 July 2016 Resolved
Companies Drug and Alcohol written policy was not accurate with regard to federal requirements for when to test and reporting. Crew was not knowledgeable of the testing requirements.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Reviewed Drug and Alcohol written policy and found it sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 July 2016 Resolved
Life raft embarkation station did not have adequate emergency lighting. Add emergency lights as required by 46 CFR 199.150(f)(6).
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified adequate emergency lighting at the embarkation station.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 7 July 2016 Resolved
Provide proper documentation proving satisfactory testing of the vessel fire detection system. 3rd party cert did not mention engine room heat detectors.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified satisfactory third party report which attested to properly operating vessel fire detection system.

Casualty record · 1

16 November 2002Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1742244
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MR. SONNY (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.