Records from 1981 to 2025. Most recent: inspection, 3 September 2025.
Inspection history · 86
3 September 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8226285
18 March 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8095576
20 November 2024
Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8037664
13 November 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7824084
27 October 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7585093
15 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7507452
31 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7503794
24 August 2021
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7291335
19 November 2020
Inclining Experiment · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099209
18 March 2020
Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6931880
18 June 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6744813
28 March 2019
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6651031
20 March 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6375279
16 June 2017
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6177714
20 March 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108207
13 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6087650
16 August 2016
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5975095
7 July 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5933314
31 March 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5844753
26 June 2012
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4356802
26 June 2012
Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4357127
22 March 2010
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3700608
1 February 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3662785
9 February 2009
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3417265
10 June 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3232943
6 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3143133
29 January 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3138504
3 July 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3008865
2 March 2006
COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2594712
9 February 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2582421
16 November 2002
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1742244
6 November 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1701968
20 August 2002
Administrative Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1663722
14 May 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1614435
25 September 2001
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370356
21 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074285
4 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072831
17 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067101
20 April 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425110
31 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820534
25 March 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470254
10 October 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 185052
29 December 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423115
13 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131446
22 May 1998
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456592
2 May 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 100100
5 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1108505
9 July 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 778638
8 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779455
20 February 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103351
31 January 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374852
12 February 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412924
31 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 642994
27 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 118942
7 April 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841785
23 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132714
13 February 1995
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428438
2 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 163044
30 January 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465186
12 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1176626
5 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860869
13 May 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1170631
30 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856321
22 December 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 449326
15 November 1993
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447286
1 November 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830141
21 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958759
15 October 1992
Re-Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253542
12 October 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245573
4 January 1991
Hull Examination · Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912439
27 August 1990
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234927
24 May 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 526664
13 October 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1315661
29 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 488676
27 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 504319
24 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 497706
15 March 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205575
13 December 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343333
8 October 1987
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1001875
29 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003659
31 October 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996022
8 October 1985
Credit Drydock · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296109
1 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289086
31 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282419
2 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973315
5 October 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025
Resolved
(a) In a space described in § 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal. Red flashing light was inoperable. Repair within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2025
Resolved
Vessels over 180 feet in length which are not passenger vessels, and which operate on international voyages or in ocean, coastwise, or Great Lakes service, must be provided with a direct emergency bilge suction from any pump in the machinery space, except that a required bilge pump may not be used. The discharge capacity of the pump selected must exceed the capacity of the required main bilge pump and the area of the suction inlet is to be equal to the full suction inlet of the pump. MI could not verify suction, make suitable arrangements to witness test within 14 days
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation of bilge suction
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 September 2025
Resolved
The lantern must be relay-controlled so that the loss of normal power causes the lanterns to light. Engine room
light and main deck lights were not working. Rectify
within 14 days
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed proper operation
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 September 2025
Resolved
The registers issued in connection with cargo gear certification must have all required entries fully completed as of the dates indicated, shall be kept current, and shall include the following:
Certification of the testing and examination of cranes, hoists, and their accessory gear;
Obtain new load test and wire fall certificate prior to the operation of the deck crane.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 11 December 2025
Resolution: Daryl Ryan sent proof of load test to MSU Texas City inbox.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 September 2025
Resolved
(a) When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work must be done under the cognizance of the Officer in Charge Marine Inspection. It must be done in accordance with the regulations in effect at the time such vessel or installation was contracted for or built (whichever is latest), or in accordance with the regulations in effect for new construction. Firemain had 02 pinhole leaks on pipe in engineroom. Rectify prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 September 2025
Resolved 17 September 2025
Resolution: MIs witnessed new section of pipe and tested the fire pump. No leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2023
Resolved
Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Port fuel shut off valve was observed inoperable. Repair valve to satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the port remote fuel shutoff valve.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 13 November 2023
Resolved
The movement of the indicator pointer shall be consistent with the movement of the steering wheel or control. MI observed the emergency steering rudder angle indicator inoperable from the emergency steering station. Repair angle indicator to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 14 November 2023
Resolution: Witnessed satisfactory operation of the local steering station rudder angle indicator.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 October 2022
Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. At exposed peripheries of the freeboard and superstructure decks, the rails shall be at least three courses, including the top.
Marine Inspectors identified significant wastage on the STBD side bridge wing ladder well.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022
Resolved
All emergency lights shall be marked with a letter "E" at least 1/2 inch high. Marine Inspectors identified three (03) emergency light fixtures to be missing the required marking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 October 2022
Resolved
The emergency lighting and power loads listed in this section shall include lighting for passageways, stairways, and escape trunks in passenger quarters, crew quarters, public spaces, machinery spaces and work spaces, adequate to permit passengers and crew readily to find their way to open decks. Marine Inspectors identified six emergency lighting fixtures to not be illuminated during emergency lighting test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 October 2022
Resolved
A stability booklet must be prepared for each vessel and must be approved by the Coast Guard Marine Safety Center. "Stability Calculations for the RMS CITATION" booklet marked "Examined" by Coast Guard Marine Safety Center referenced in the vessel's Stability Letter shall be kept on-board and available for inspection at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 4 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 March 2019
Resolved
Vessel is required to have a steering system which indicates at the primary operating station the position of the rudder. MIs discovered that none of the rudder position indicators matched. This includes the indicators on the bridge, as well as on the jockey bar in the steering room.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 9 April 2019
Resolution: Rudder angle indicators now in sync.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 13 February 2017
Resolved
Vsl owener has let ILLC expire. ABS has placed vessel on their layup vessel status. Issued CG-835 restricting vessel to operations inside of the boundary line due to expired Load Line Certificate. Owner's plan is to request via ABS and complete Load Line surveys at next dry dock period commencing 2017.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 20 March 2018
Resolution: verifed vsl has valid loadline cert.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 7 July 2016
Resolved
Vsl's crew was unable to demonstrate over speed shut down for either MDE. Prove proper operation of the over speed shutdown device for both MDEs.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 16 August 2016
Resolution: Both MDE overspeed trips verified operational, to include shutdowns from the bridge.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 July 2016
Resolved
Vessel's fire/safety control plan was displayed but not legible. Also needs to be updated to reflect current equipment installed on board.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Fire and safety plan stampled approved.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 July 2016
Resolved
Companies Drug and Alcohol written policy was not accurate with regard to federal requirements for when to test and reporting. Crew was not knowledgeable of the testing requirements.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 19 August 2016
Resolution: Reviewed Drug and Alcohol written policy and found it sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 July 2016
Resolved
Life raft embarkation station did not have adequate emergency lighting. Add emergency lights as required by 46 CFR 199.150(f)(6).
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified adequate emergency lighting at the embarkation station.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 7 July 2016
Resolved
Provide proper documentation proving satisfactory testing of the vessel fire detection system. 3rd party cert did not mention engine room heat detectors.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 16 August 2016
Resolution: Verified satisfactory third party report which attested to properly operating vessel fire detection system.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 March 2010
Resolved
Install emergency lighting on nav. bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 22 March 2010
Resolved
Prove proper operation of Port generator set overspeed trip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 22 March 2010
Resolved
Ensure proper operation of ground fault lights on main electriacl panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Engineering › Fuel Oil Service System › Valve
Issued 22 March 2010
Resolved
Repair replace linkage for port side fuel day tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2010
Fire Fighting › Fire Hoses › Condition
Issued 9 February 2009
Resolved
Fire hoses not hydro tested
Condition: Improper/Lack of Maintenance
Due 14 February 2009
Resolved 12 February 2009
Resolution: Witnessed hydro test
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 9 February 2009
Resolved
Port Generator over speed would only take engine to idle but would not completely shutdown engine
Condition: Unknown
Due 13 February 2009
Resolved 12 February 2009
Resolution: Witnessed overspeed test
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 March 2006
Resolved
Vessel shall not operate newly installed A-frame until a load test has been completed to the satisfaction of an attending Coast Guard inspector.
Action required: 705 - Other - as specified
Due 5 March 2007
Resolved 31 January 2008
Resolution: A-frame has been removed from vessel. Cleared load test requirement and added special note for required completion of load test upon re-installation of A-frame.
Engineering
Issued 14 May 2002
Resolved
DRAFT AND SUBMIT AUTOMATION TEST PROCEDURES FOR REVIEW. LEGACY COMPONENT DESC: automation test procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2002
Resolved 12 August 2002
Resolution: Approved
Lifesaving
Issued 25 March 2000
Resolved
DEMONSTRATE COMPLIANCE WITH THE USCG 8TH DISTRICT POLICY LETTER "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED 12NOV98. TESTING & INSTALLATION SHALL BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR & PRIOR TO 24APR00.
Condition: Unknown
Due 25 March 2000
Resolved 25 March 2000
Electrical
Issued 25 March 2000
Resolved
MAKE PERM REPAIRS TO INOP PORT ENG OIL TEMP INDICATOR ON WHEELHOUSE ALARM PANEL.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Documentation
Issued 25 March 2000
Resolved
PROVIDE CURRENT COPY OF THE LIGHT LIST.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Navigation
Issued 29 December 1998
Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND UHF RADIO.
Condition: Unknown
Due 28 January 1999
Resolved 6 January 1999
Electrical
Issued 29 December 1998
Resolved
SECURE ALL WIRING IN ENGINE ROOM AND BRIDGE AS PER IEEE-45 STD.
Condition: Unknown
Due 28 January 1999
Resolved 10 March 1999
Accommodation/Occupational Safety
Issued 29 December 1998
Resolved
INSTALL PROPER CLOTHES DRYER EXHAUST VENT DUCTING. (METAL)
Condition: Unknown
Due 28 January 1999
Resolved 10 March 1999
Lifesaving
Issued 29 December 1998
Resolved
PROVIDE PROOF OF EPIRB REGISTRATION.
Condition: Unknown
Due 28 January 1999
Resolved 13 January 1999
Engineering
Issued 29 December 1998
Resolved
RENEW ALL IDENTIFIED HOSES ON VESSEL EQUIPMENT/ENGINES DUE TO CHAFFING OR LEAKAGE.
Condition: Unknown
Due 28 January 1999
Resolved 26 January 1999
Fire Fighting
Issued 29 December 1998
Resolved
PROVIDE ON BOARD VESSEL AN APPROVED FIRE/SAFETY PLAN.
Condition: Unknown
Due 28 January 1999
Resolved 26 April 1999
Construction/Loadline
Issued 22 May 1998
Resolved
PROVIDE APPROVED PLANS FOR DECK MODIFICATIONS RELATED TO JET PUMP INSTALLATION.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Electrical
Issued 31 January 1997
Resolved
REPLACE AND PROVE PROPER OPERATION OF THE OVERSPEED TRIP ON THE PORT GENERATOR.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Lifesaving
Issued 31 January 1997
Resolved
INSTALL PAINT LOCKER ON MAIN DECK AND EQUIP IT WITH PORTABLE CO2 FIRE EXTINGUISHER.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Engineering
Issued 31 January 1997
Resolved
PROVE PROPER OPERATION OF PORT MAIN DIESEL ENGINE OVERSPEED TRIP, HIGH JACKET WATER TEMPERATURE ALARM AND HIGH LUBE OIL TEMPERATURE ALARM.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Navigation
Issued 31 January 1997
Resolved
REPLACE AND PROVE PROPER OPERATION OF AFT RUDDER ANGLE INDICATOR IN ENGINE ROOM.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Electrical
Issued 31 January 1997
Resolved
REPLACE AND PROVE PROPER OPERATION OF STARBOARD GENERATOR RPM GAUGE.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Electrical
Issued 31 January 1997
Resolved
PROVE PROPER OPERATION OF THE HIGH LUBE OIL TEMPERATURE ALARM ON THE STARBOARD GENERATOR.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Fire Fighting
Issued 31 January 1997
Resolved
REPAIR FIREMAIN PIPING NEAR FIREPUMP AS ORIGINAL AND PROVIDE CG APPROVED WELD PROCEDURES/WELDERS QUALS FOR JOB.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Electrical
Issued 31 January 1997
Resolved
PROVIDE METAL SUPPORTS FOR ALL HORIZONTAL/VERTICAL CABLE RUNS THROUGHOUT VESSEL.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Engineering
Issued 31 January 1997
Resolved
INSTALL AND PROVE PROPER OPERATION OF THE STARBOARD MAIN DIESEL ENGINE RPM GAUGE.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Documentation
Issued 31 January 1997
Resolved
PROVIDE STCW CERTIFICATES FOR MASTER AND CREWMEMBERS ON BOARD.
Condition: Unknown
Due 31 January 1997
Resolved 31 January 1997
Documentation
Issued 30 January 1995
Resolved
PROVIDE AOUTMATION TEST PROCEDURES
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Documentation
Issued 15 November 1993
Resolved
PROVIDE NEW STABILITY LTR ONBOARD REFLECTING INSTALLATION OF CRANE.
Condition: Unknown
Due 15 November 1993
Resolved 15 November 1993
Deck/Cargo
Issued 1 November 1992
Resolved
REMOVE WASTED CHAIN FROM FOREPEAK CHAIN LOCKER NOT LATER THAN NEXT DRYDOCK EXAM.
Condition: Unknown
Due 1 November 1992
Resolved 1 November 1992
Construction/Loadline
Issued 15 October 1992
Resolved
REPAIR / REPLACE CIRCUIT BOARD IN AUTOMATION PANAL FOR BILGE ALARMS LOCATEDIN ENGINE ROOM AND PROVE PROPER OPERATION.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Fire Fighting
Issued 15 October 1992
Resolved
REPLACE FIVE (05) PORTABLE FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Navigation
Issued 8 October 1985
Resolved
REPAIR RUDDER ANGLE INDICATOR FOR EMERGENCY STEERING STATION.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Engineering
Issued 8 October 1985
Resolved
REPAIR MAIN ENGINE SHAFT TACKS AND DEMONSTRATE THEIR OPERATION.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Engineering
Issued 8 October 1985
Resolved
REPAIR BRIDGE MAIN ENGINE EMERGENCY SHUTDOWNS AND DEMONSTRATE THEIR OPERATION.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Engineering
Issued 8 October 1985
Resolved
REPAIR STBD EXHAUST STACK BLOWER AND DEMONSTRATE EMERGENCY SHUTDOWN.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Electrical
Issued 8 October 1985
Resolved
REPAIR ALARM HORN FOR REDUCED MANNING CONTROL PANEL.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Navigation
Issued 2 May 1984
Resolved
PERMANENTLY REPAIR THE AFTER RUDDER ANGLE INDICATOR IN THE WHEELHOUSE.
Condition: Unknown
Due 2 May 1984
Resolved 2 May 1984
Unknown
Issued 2 May 1984
Resolved
THE FOLLOWING ITEM PERTAINS TO THE M/V SEA LEVEL NO. 21, O.N. 616274.
Condition: Unknown
Due 2 May 1984
Resolved 2 May 1984