MAURY USCG vessel records Sign in
← All vessels

FMS JUSTICE

FMS JUSTICE is a 1983 offshore supply vessel. The Coast Guard has recorded 55 inspections since 1983, most recently in October 2017, along with 33 deficiencies — 4 with no resolution recorded — and 1 casualty investigation in 2012.

Records from 1983 to 2017. Most recent: inspection, 19 October 2017.

Built
1983
Last inspected
19 October 2017
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8322258 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG6165
Flag
UNITED STATES
366972190, 367554190 (licence lapsed)
Maury page id
psix-54918

Inspections, by type

…with no type recorded19
…past their stated due date4
Years with a record 30 calendar years (1983–2017)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)177.4 ft × 42.0 ft × 12.0 ft
Registered tonnagegross 296 / net 201
ITC dimensions (L × B × D)177.4 ft × 42.0 ft × 12.0 ft
ITC tonnagegross 874 / net 262
BuilderMOSS POINT MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it296 - Regulatory (Subpart C or D), Gross Ton
874 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
262 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG6165MMSI 367554190 · expired · compulsorily equipped · granted 20 November 2012, cancelled 21 January 2023
WDB9235MMSI 366972190 · expired · compulsorily equipped · granted 19 August 2004, cancelled 25 October 2014 · licensed under a name not among this hull’s recorded names (not shown)
WAS2428MMSI not assigned · cancelled · compulsorily equipped · granted 17 April 1997, cancelled 7 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RMS CITATION Offshore Supply Vessel · MISLE 51358 · 2 February 1995 · activity 163044GIS-SEARCHER Commercial Fishing Vessel · MISLE 51919 · 28 August 1994 · activity 79001

Inspection history · 55

19 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6291195
24 July 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6218923
16 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6178014
1 August 2016 Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5959857
23 February 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5837231
30 August 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4979076
16 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4117231
10 August 2011 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4111567
22 December 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3919631
17 December 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3914798
3 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3373398
19 August 2008 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3302784
21 September 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3063012
28 February 2007 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2879327
19 September 2006 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2789021
7 June 2005 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2381731
19 October 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2231046
23 June 2004 Re-Inspection · MTSA Verification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2108566
12 June 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1630555
31 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401480
10 May 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460415
15 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 178658
1 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350281
2 July 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436232
25 August 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762693
26 July 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190243
11 May 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473012
4 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 95837
4 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788746
25 June 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461809
9 May 1996 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407664
12 July 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1358841
16 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866735
2 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 163044
28 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 79001
13 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859647
13 May 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377175
8 November 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829989
13 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154952
22 April 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838010
11 August 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838902
24 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213531
26 April 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226315
12 February 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229120
7 February 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918267
25 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1210722
10 April 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 893476
31 March 1988 Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202893
10 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014796
9 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296937
3 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286983
7 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976049
26 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282011
16 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973630
27 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272393

Deficiency record · 33

Operations/Management › Drills/Instruction › Not Conducted
Issued 24 July 2017 No resolution recorded
Vessel did not conduct drills 46 CFR 91.25-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2017 — due date passed with no resolution recorded
Engineering › Compressed Air System (start air) › Compressor
Issued 24 July 2017 No resolution recorded
Need to install Guards on moving parts. 46 CFR 92.25-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2017 No resolution recorded
Multiple cables must be made watertight entering boxes. Multipy areas in machinery spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 July 2017 No resolution recorded
Vessel has missing air actuator for #3P P tank which is use to open and close the valve. 46 CFR 56.20-9
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 10 August 2011 Resolved
Overspeed trips on both generators failed. CG 835 was issued to prove propper operation prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2011
Resolution: Recieved third party report that repairs had been made and overspeeds tested satisfactory. Third party report attached in Documents.
Construction/Loadline › Hull › Hull Plating
Issued 19 August 2008 Resolved
Crop and renew inset and crack on stern as noted by marine inspector by next drydock. Install temporary repair (drill stop/gouge and reweld) prior to departure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 19 September 2008
Construction/Loadline › Hull › Hull Plating
Issued 19 August 2008 Resolved
Crop and renew inset on bow as noted by marine inspector by next drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2009
Resolved 22 September 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 August 2008 Resolved
Pump bilges of oily waste.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2008
Resolved 22 September 2008
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 19 August 2008 Resolved
Replace expired safety harness for man over board recovery.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2008
Resolved 22 September 2008
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 August 2008 Resolved
Fix/replace fire main pressure guage on bridge.
Due 19 September 2008
Resolved 22 September 2008
Construction/Loadline › Penetrations › Gasket
Issued 19 August 2008 Resolved
Fix water tight doors (fore and aft) to engine room to allow them to close and seat properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2008
Resolved 22 September 2008
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 19 August 2008 Resolved
Provide means to safely retrieve unconscious man over board.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2008
Resolved 22 September 2008
Fire Fighting › Fire Main › Condition
Issued 19 August 2008 Resolved
Repair wastage in fire main.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2008
Resolved 22 September 2008
Deck/Cargo › Cargo Stowage › General
Issued 19 September 2006 Resolved
Dry Bulk tanks are past inspection date. Discontinue use until inpection is complete and approved by attending marine inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2006
Resolved 29 September 2006
Lifesaving › Inflatable Liferafts › Painter
Issued 19 September 2006 Resolved
Incorrect arrangement
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 19 September 2006 Resolved
Prove operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2006
Communications › Radio Communications › EPIRB
Issued 19 September 2006 Resolved
Registration outdated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 September 2006 Resolved
Prove operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2006
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Marine Type Label
Issued 12 June 2002 Resolved
Provide one approved type portable fire extinguisher for rescue boat.
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: Vessel purchased one B-II portable fire extinguisher for rescue boat.
Lifesaving › Hand Flares › Quantity
Issued 12 June 2002 Resolved
Provide two hand held parachute flares to replace the two that are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: Vessel purchased two hand held parachute flares.
Fire Fighting › Fire Pumps
Issued 12 June 2002 Resolved
Repair or replace damaged pressure gauge for fire pump on bridge. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: The pressure gauge was replaced.
Deck/Cargo › Cargo Transfer (solid)
Issued 12 June 2002 Resolved
Replace safety relief valves on dry bulk tanks with ASME certified relief valves.
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: Vessel provided seven ASME stamped relief valves. All were bench tested in the presence of Coast Guard inspectors.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 June 2002 Resolved
Replace retro reflective tape on port bridge wing lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: The retro reflective tape was replaced on the port lifebuoy.
Pollution Prevention/Response
Issued 12 June 2002 Resolved
Properly removed oily waste and debris from bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: All oily waste and debris was removed from bilges.
Engineering › Fuel Oil Service System › Pump
Issued 12 June 2002 Resolved
Make proper repairs to fuel oil transfer pump monitor to stop leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2002
Resolved 12 June 2002
Resolution: The packing and phlanges were tightens which stopped the leaks.
Lifesaving
Issued 2 July 1999 Resolved
PROVIDE RESCUE BOAT TO MEET RQMTS. AS PER 8TH DISTRICT POLICY LETTER 16613 DATED 12NOV99.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 12 July 1995 Resolved
REMOVE OIL AND WATER FROM BILGES. PROVE PROPER DISPOSAL OF OIL.
Condition: Unknown
Due 19 July 1995
Resolved 19 July 1995
Fire Fighting
Issued 22 April 1993 Resolved
PROVIDE FRESH AIR BREATHING APPARATUS COMPLETE WITH SPARE CHARGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Documentation
Issued 22 April 1993 Resolved
COMPLETE ABS SURVEY AND OBTAIN LOADLINE CERTIFICATE. PROVIDE [name withheld] WITH COPY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Navigation
Issued 22 April 1993 Resolved
DEMONSTRATE PRIOR OPERATION OF #2 STEERING PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Engineering
Issued 22 April 1993 Resolved
INSTALL MARINE KITS FOR RAYCOR FILTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Accommodation/Occupational Safety
Issued 16 April 1984 Resolved
INSTALL A SECOND VENTILATION SHUTDOWN FOR ACCOMODATION AND GALLEY SPACES IN ACCORDANCE WITH 46 CFR 111.103-1.
Condition: Unknown
Due 16 April 1984
Resolved 16 April 1984
Unknown
Issued 16 April 1984 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE NICOR REBEL, DN655966.
Condition: Unknown
Due 16 April 1984
Resolved 16 April 1984

Casualty record · 1

1 August 2012Routine · role: Involved in a Marine Casualty · activity 4398265
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JF JETT (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record