MAURY USCG vessel records Sign in
← All vessels

SEACOR GALE

SEACOR GALE is a 2002 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2002, most recently in March 2023, along with 1 deficiency and 1 casualty investigation in 2003.

Records from 2002 to 2023. Most recent: inspection, 9 March 2023.

Built
2002
Last inspected
9 March 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765541 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG3600
513652
Flag
UNITED STATES
366857460, 367527720 (licence lapsed)
Maury page id
psix-513652

Inspections, by type

…with no type recorded5
Years with a record 13 calendar years (2002–2023)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)132.0 ft × 92.0 ft × 13.0 ft
Registered tonnagegross 173 / net 126
ITC dimensions (L × B × D)132.0 ft × 92.0 ft × 13.0 ft
ITC tonnagegross 1,303 / net 390
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1303 - Convention (Subpart B), Gross Ton
173 - Regulatory (Subpart C or D), Gross Ton
390 - Convention (Subpart B), Net Ton
126 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG3600MMSI 367527720 · expired · compulsorily equipped · granted 27 April 2012, cancelled 2 July 2022
WDA8730MMSI 366857460 · cancelled · compulsorily equipped · granted 13 June 2002, cancelled 1 May 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

C-ADVENTURER Offshore Supply Vessel · MISLE 491013 · 19 February 2003 · activity 1748991

Inspection history · 20

9 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7648470
14 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371589
12 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762533
30 January 2012 Administrative Inspection · Damage Survey · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4234856
9 December 2010 Drydock Extension · DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891798
21 January 2010 Examination of Repairs · MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3667256
19 March 2009 Annual Inspection · MARPOL Annex II Examination · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3436124
20 July 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3274592
14 February 2008 MARPOL Annex II Examination · Examination of Repairs · Internal Structural Exam · Hull Examination · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147589
17 January 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2857099
7 January 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2852065
25 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2658525
2 December 2005 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2543653
17 June 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2398118
3 February 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2285878
17 November 2004 Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2238430
13 February 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2006447
3 March 2003 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1751783
19 February 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1748991
21 November 2002 Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1708927

Deficiency record · 1

Engineering › Pressure Vessel › Relief Valve
Issued 19 March 2009 Resolved
Pressure relief valves on 3 water heaters must be replaced with 100 psi at 200 degrees type.
Due 19 April 2009
Resolved 28 January 2010

Casualty record · 1

19 February 2003Routine · role: Involved in a Marine Casualty · activity 1748991
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SUPERIOR GALE (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.