07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2026
Resolved
Found gen set not connected to Fire Boy shut down system. Repair system of based on availability of parts and attendance of service technician
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Obtained parts and connected unit to shut down system, test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 June 2022
Resolved
Install door alarm with open/closed indication and post required signage on door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 23 June 2022
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 May 2021
Resolved
Replace expired battery. Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 25 June 2021
Resolved 16 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021
Resolved
Provide Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021
Resolved
Provide brackets for two portable extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 25 May 2021
Resolved
Make watertight all WTB openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
Install guards on MDEs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
Address issue with breather on port MDE.
Action required: 705 - Other - as specified
Due 8 June 2021
Resolved 25 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
Label Bilge manifold system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 May 2021
Resolved
Label upper deck pax limit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021
Resolved
Prove operation of engine driven pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2019
Resolved
Properly repair two soft patches in the fire main aft of the starboard engine just off the fire pump with solid piping or approved flexible hose with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Piping replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 November 2019
Resolved
Fuel shutoff valve is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2020
Resolution: New valve installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2019
Resolved
Fuel lines on bot engines are wasted, crimped, not in serviceable condition. Replace with proper, approved hoses with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: fuel lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
Poperly repair both engine exhaust pipes. Both are heavily corroded and both have improper repairs on them.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: new piping installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019
Resolved
Life-float placed out of service. Lines are wasted and there is paint covering the approval label.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: Vessel route is updated for sector NNE LBS plus LCW not more than 20 miles from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2019
Resolved
Properly stow lifejackets and mark stowage according to the regulations. Marking is faded and some lifejackets are stowed below decks in garbage bags.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Lifejacket stowage restenciled
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 November 2019
Resolved
First Aid kit is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Updated first aid kit provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019
Resolved
Bilge valve forward of collision bulkhead inoperative.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: new valve installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019
Resolved
Drug and Alcohol Program verification not available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: DAPI information provided for current crew
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 November 2019
Resolved
Did not conduct man overboard drill. Questioned the crew about the use of the EPIRB and neither crew knew how to test or operate the EPIRB in case of an emergency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Satisfactory drills conducted.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019
Resolved
Properly repair leak in hydraulic fluid tank/hoses/fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New hoses installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2019
Resolved
Generator exhaust has a leak through a wasted pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New piping installed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2019
Resolved
Port side hull iwo the storage compartment under the operating station near the aft bulkhead had an indentation and possible hull crack. There is also an improper doubler strip in the same area from a prior repair. Crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Hull was not cheaked from the outside. Welds were veed abnd re-welded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019
Resolved
Remove oil saturated wood from underneath the battery box and the generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Oil soaked wood removed
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2019
Resolved
Properly clean the bilges in the engine room and lazarette and make available for proper inspection of widespread pitting in the hull plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Bilges were cleaned
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2019
Resolved
All around light is inoperative, possibly due to wasted wiring and the mast for the light is broken at the weld at the top of the house. repair broken mast and provide a working all around light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Mast head light provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
Properly repair electrical wiring throughout the entire vessel. There are numerous open electrical boxes (in engine room, outside on the open decks and under the operating station). Dead-end wires are prevalent throughout the vessel and wiring is connected with electrical tape in several areas such as the bilge high water alarm in the engine room. Numerous deck lights are duct taped in place to hold them up. There are extension cords being used as permanent wire (under the operating station and in the engine room on the starboard side. All electrical connections must be done with proper crimped or screwed ends into junction boxes with the proper boat cable used.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Dead end wiring removed.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 6 November 2019
Resolved
Replace all sun faded and cloudy bridge windows.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 29 November 2019
Resolution: Received photos from owner. All bridge windows replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make battery charger connection to battery on bridge a permanent type connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Permanent connections installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove all dead-end wires from being the helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all dead end wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make all wire connections iaw 46CFR183.340(g), (H) or (i).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all incorrect connections removed or peroperly repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove or protect fuse panel in way of bridge battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New breaker pannel installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 September 2018
Resolved
Permanently mount EPIRB housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove derelict air conditioner unit from upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018
Resolved
Provide (03) adult life jackets. Vessel restricted to carriage of 125 total persons until cleared.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New PFDs installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make proper wire connections for main-deck air conditioner unit and provide junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: A/C removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Provide switch and over current protection of MSD macerator pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New switch and fuse installed.
Lifesaving › Lifefloat › Serviceable
Issued 30 November 2017
Resolved
Replace or make permanent repairs to damaged life float.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 16 January 2018
Resolution: Lifefoat repaired and painted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2017
Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: First aid kit updated.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 November 2017
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Emergency Instructions posted.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 30 November 2017
Resolved
Replace starboard transmission cable.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Cable properly repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 November 2017
Resolved
Prove proper operation of mast lights.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Nav lights properly working.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 November 2017
Resolved
Prove proper operation of lazarette bilge high water alarm (buzzer).
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Bilge alarm properly alarming.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 November 2017
Resolved
Provide covers for battery boxes.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Battery boxes properly covered.
Engineering › Steering Gear System › Hydraulic Hose
Issued 30 November 2017
Resolved
Repair leaks on hydraulic steering system in Engine Room and seal on steering ram.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 January 2018
Resolution: Leak repaired
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 November 2017
Resolved
Prove proper operation of fireboy engine shutdowns.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Fireboy shut-down properly working.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 20 October 2016
Resolved
Demonstrate proper machinery and ventilation shut-downs with fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: Shut-downs satisfactorily demonstrated.
Engineering › Bilge Water Management System › Pump
Issued 20 October 2016
Resolved
Prove proper operation of bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Tested bilge system, found to be in satisfactory condition.
Communications › Visual Communication › Red Warning Signal
Issued 20 October 2016
Resolved
Provide a total of 6 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: All required signaling devices on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2016
Resolved
Provide current first-aid kit.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Firstaid kit renewed with current items.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2016
Resolved
Provide guard for generator fan belt.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Guard installed on generator fan belt.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 October 2016
Resolved
Renew retroreflective tape on identified life jackets.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Retro reflective tape renewed on identified life jackets.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2016
Resolved
Properly label lifejacket storage.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Life jacket storage properly labeled.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 October 2016
Resolved
Properly secure electrical outlet in steering gear room.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Electrical outlet properly secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 October 2016
Resolved
Repair or remove distribution box on aft bulkhead of bridge.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Junction box properly repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2016
Resolved
Provide proper wiring from bridge A/C unit and main cabin reefer.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Extension cord removed from reefer and AC properly wired.
Documentation › Markings/Placards › Garbage Placard
Issued 20 October 2016
Resolved
Provide current MARPOL V placard.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: MARPOL placard updated.
Communications › Radio Communications › Emergency Source of Power
Issued 20 October 2016
Resolved
Remove excess wiring on bridge battery.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Excess wires removed from battery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 October 2016
Resolved
Properly secure bridge and engine room batteries.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 23 November 2016
Resolution: Batteries properly secured.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2016
Resolved
Provide updated Coast Pilot [name withheld] and Light List.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publications updated.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2016
Resolved
Provide Rules of the Road.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publication updated.
Communications › Radio Communications › EPIRB
Issued 20 October 2016
Resolved
Provide current hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: New hydrostatic release installed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 October 2014
Resolved
Prior to carrying passengers, provide proof of employees enrolled in a Company Random Drug Testing Consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2014
Resolved 9 October 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 9 October 2014
Resolved
Prior to carrying passengers, provide 5 year hydrostatic testing of wheelhouse portable CO2 fire extinguisher or provide a satisfactory replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2014
Resolved 9 October 2014
Resolution: Provided satisfactory replacement.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 October 2014
Resolved
Prior to carrying passengers, provide and install a USCG Approved Floating Waterlight for Lifefloat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2014
Resolved 9 October 2014
Communications › Radio Communications › EPIRB
Issued 9 October 2014
Resolved
Prior to carrying passengers, provide proof of EPIRB registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2014
Resolved 9 October 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 October 2014
Resolved
Double up all raw water cooling exhaust hoses with steel clamps, as shown.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 28 April 2015
Fire Fighting › Fire Hoses › Condition
Issued 9 October 2014
Resolved
Install vessels name on fire hose.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 28 April 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 October 2014
Resolved
Prior to carrying passengers, prove proper operation of anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2014
Resolved 9 October 2014
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 21 October 2010
Resolved
UPDATE SAFETY RADIO TELEPHONE CERT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 18 July 2011
Personnel › Training › First Aid/CPR
Issued 21 October 2010
Resolved
PROVIDE CPR AND FIRST AID CERT.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 18 July 2011
Lifesaving › Hand Flares › Expired
Issued 21 October 2010
Resolved
PROVIDE 6 ORANGE AND 6 RED FLARES
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 18 July 2011
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 16 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL VESSELS NAME AND HOMEPORT ON STERN AS PER CERTIFICATE OF DOCUMENTATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2008
Resolved 30 September 2008
Resolution: Corrected
Construction/Loadline › Structures › Scuttle
Issued 16 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL SECURING DEVICE(S) FOR ALL MAIN DECK WATERTIGHT FLUSH HATCH COVERS AS PER 46 CFR 179.360(b).
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2008
Resolved 30 September 2008
Resolution: Corrected
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE COMPANY POLICY TO MEET THE TWO (2) HOUR RULE IN CASE OF A SERIOUS MARINE INCIDENT (SMI)
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2008
Resolved 30 September 2008
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, ENSURE PROPER OPERATION OF REMOTE FUEL SHUT-OFF.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Cleared
Electrical › Electric Generation Source (service) › Power Requirement
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND PROVE PROPER OPERATION OF A SECOND SOURCE OF POWER AS PER 46 CFR 183.310. PROPOSAL SHALL BE SUBMITTED FOR REVIEW PRIOR TO ANY WORK CONDUCTED..
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 29 September 2008
Resolution: Cleared administratively. Approved to operate until 29 October 2008 with current F/F configuration.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE DRAWINGS, SKETCHES AND/OR WRITTEN SPECIFICATIONS DESCRIBING THE DETAILS OF THE FIRE PUMP "AS BUILT" INSTALLATION FOR REVIEW.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 29 September 2008
Resolution: Cleared as part of the plan review for new fire pump installation
Engineering › Bilge Water Management System › Not Operational
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARMS AS PER 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Corrected
Construction/Loadline › Structures › Door
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL A QUICK ACTION WATERTIGHT BULKHEAD DOOR AS PER 46 CFR 179.330(b). PROVIDE DRAWINGS, SKETCHES AND/OR WRITTEN SPECIFICATIONS DESCRIBING THE DETAILS OF THIS INSTALLATION FOR REVIEW PRIOR TO INSTALLATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Exemption until next dry-dock. Will add special note.
Fire Fighting › Fire Pumps › Arrangement
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE DRAWINGS, SKETCHES AND/OR WRITTEN SPECIFICATIONS DESCRIBING THE DETAILS OF THE FIRE PUMP INSTALLATION FOR REVIEW.
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 16 December 2008
Resolution: Installation approved and complete
Engineering › Bilge Water Management System › Pump
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, SUBMIT DRAWINGS, SKETCHES AND/OR WRITTEN SPECIFICATIONS DESCRIBING THE DETAILS OF THE PROPULSION BELT-DRIVEN BILGE PUMP FOR REVIEW.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2008
Resolved 16 December 2008
Resolution: Approved and complete
Engineering › Bilge Water Management System › Not Operational
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF APPROVED BILGE PUMP FROM EACH COMPARTMENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Fire Fighting › Means of Escape › Blocked
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ENGINE ROOM EMERGENCY ESCAPE SCUTTLE AS PER 46 CFR 177.500(h).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MARK ALL ESCAPE HATCHES AND OTHER EMERGENCY EXITS AS PER 46 CFR 185.606.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 5 September 2008
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF AUTOMATIC SHUT-DOWNS AS PER 46 CFR 181.420(3).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 29 September 2008
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND PROVE PROPER OPERATION OF FIXED FIREFIGHTING SYSTEM AS PER 46 CFR 181.420(b).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 29 September 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Pump
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PORTABLE HAND BILGE PUMP AS PER 46 CFR 520(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 September 2008
Resolved
IDENTIFY AND MARK ALL ELECTRICAL EQUIPMENT AND CIRCUITS AS PER 46 CFR 183.220(d).
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE TWO (2) OPERATIONAL PORTABLE BATTERY LIGHTS AND INSTALL AS PER 46 CFR 183.430.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Operations/Management › Passenger Operations › Safety Orientation
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM AS PER 46 CFR.610(c).
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT ALL REQUIRED CREW EMERGENCY DRILLS AND LOG IN VESSELS LOG BOOK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 1 October 2008
Resolution: Satisfactory drills were logged and performed by the crew.
Engineering › Steering Gear System › Ram Seal
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO HYDRAULIC STEERING RAM SEAL FOUND LEAKING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Engineering › Steering Gear System › Fastener
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, RE-INSTALL ALL STEERING GEAR MOUNTING HARDWARE FOUND UPSIDE DOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Engineering › Steering Gear System › Pin
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL PIN RETAINING DEVICE FOR ALL STEERING GEAR PINS WHERE FOUND MISSING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Duplicate deficiency
Engineering › Steering Gear System › Piping
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO HYDRAULIC OIL LEAKAGE FOUND AT HYDRAULIC OIL STORAGE TANK PIPING LOCATED STBD SIDE OF ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2008
Resolved
PROVIDE AND INSTALL METAL SUPPORTS FOR ALL WIRING LOCATED IN ENGINE ROOM NOT MORE THAN TWENTY-FOUR (24) INCHES APART AND INSTALLED IN SUCH A MANNER AS TO AVOID CHAFING AND OTHER DAMAGE.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2008
Resolved
PROVIDE SUPPORT OF ALL WIRING AND HOSES FOUND IN ENGINE ROOM BILGES.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PERMANENTLY CLOSE ALL OPENINGS FOUND IN ALL WATERTIGHT BULKHEADS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Fire Fighting › Fire Hoses › Material
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF THAT FIRE HOSE ON BOARD IS IN ACCORDANCE WITH 46 CFR 181.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Fire Fighting › Combustible Materials › Matresses
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF THAT ALL MATTRESSES ON BOARD MEET 46 CFR 177.405(g) OR REMOVE ALL FROM VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Construction/Loadline › Structures › Scuttle
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF ALL DECK SCUTTLES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 5 September 2008
Resolved
Provide nameplate data for installed ship's service generator.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 28 September 2009
Resolution: Added to special notes section
Construction/Loadline › Structures › Ventilators
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL WIRE PENETRATION FITTING FOR ALL OPEN WIRE PENETRATIONS FOUND IN PORT AND STARBOARD ENGINE ROOM VENTILATION TRUNK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO PORT ENGINE ROOM VENTILATION FAN AND ELECTRIC MOTOR HOUSING AND MOUNTING.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Corrceted
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL APPROVED MOUNTING BRACKET FOR B-IV PORTABLE FIRE EXTINGUISHER LOCATED IN LOWER STORE ROOM OR REMOVE FROM VESSEL IN ITS ENTIRETY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE WRITTEN DETAILS OF PROPOSED ANCHORING GEAR AND METHOD OF RELEASING AND RETRIEVING OF SAME.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Weighed anchor, 85lbs, demonstrated capability to deploy.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, UPDATE RADIO EMERGENCY BROADCAST INSTRUCTIONS MOUNTED IN WHEELHOUSE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL CURRENT HYDROSTATIC RELEASE UNIT (HRU) FOR EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE A VALID EPIRB REGISTRATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Valve
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF FOREPEAK BILGE SUCTION VALVE REMOTE OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL ENGINE ROOM FIXED FIRE FIGHTING MANUAL PULL CABLE AS PER 46 CFR 181.410(b)(4) and 181.410(b)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Corrected
Documentation › Markings/Placards › Capacity Marking
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS ON UPPER DECK, LABEL MAXIMUM PERSONS ALLOWED FOR SAME.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, SEAL ALL WATERTIGHT BULKHEAD WIRING PENETRATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE ORIGINAL CERTIFICATE OF DOCUMENTATION TO BE RETAINED ON BOARD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF ENROLLMENT OF EMPLOYEES IN A DRUG TESTING CONSORTIUM UNDER VESSEL'S OWNER.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE ALL DEAD-ENDED WIRING FROM VESSEL.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 30 September 2008
Resolution: Cleared deficiency. Requirement will be transferred to special notes section to ensure owner makes progress in wire removal during future inspections.
Navigation › Piloting/Steering › Marine Charts
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE CURRENT NAVIGATION CHART FOR U.S. VIRGIN ISLANDS WATERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL AN ACCEPTABLE METALLIC THROUGH BULKHEAD FITTING AND SHUT-OFF VALVE(S) FOR PVC DRAIN PIPE, AS SHOWN, AS PER 46 CFR 182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Electrical › Lighting (service) › Lighting Feeder
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE GLOBE FOR LAZARETTE OVERHEAD NAKED LIGHT FIXTURE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Engineering › Steering Gear System › Fastener
Issued 5 September 2008
Resolved
MAKE PERMANENT REPAIRS TO ELONGATED MOUNTING HOLE FOR STEERING HYDRAULIC RAM AT NEXT DRY DOCKING.
Action required: 705 - Other - as specified
Due 28 July 2010
Resolved 15 September 2008
Resolution: Corrected
Engineering › Steering Gear System › Piping
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE AND INSTALL ADEQUATE SUPPORT FOR ALL HYDRAULIC PIPING LOCATED IN LAZARETTE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, SEAL DECK WIRE PENETRATION FITTING LOCATED IN PASSENGER SALON BELOW SINK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, DOUBLE UP STEEL CLAMPS, STBD MAIN ENGINE AFT EXHAUST HOSE AND PORT MAIN ENGINE AFT EXHAUST HOSE, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO BROKEN WATERTIGHT BHD WIRE PENETRATION FITTING FOUND STBD, FWD SIDE OF FIRE PUMP COMPARTMENT, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, ADJUST STBD MAIN ENGINE SEA VALVE TO ENSURE THE CAPABILITY OF FULL CLOSURE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, DOUBLE STEEL CLAMP TOILET WATER SUPPLY HOSE IN ENGINE ROOM, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 15 September 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 5 September 2008
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO HOLED TOILET DRAIN ALUMINUM PIPE LOCATED IN ENGINE ROOM OVERHEAD, AS SHOWN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 30 September 2008
Resolution: Temporary repair to be corrected permanently prior to next inspection. Inspection note will be added.
Personnel › Training › Familiarization Training
Issued 31 July 2008
Resolved
Complete New-to-Zone inspection with MSD St Thomas prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 July 2008
Resolved
Install metal wiring supports for wiring above MDE's
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2008
Resolution: CLEARED DUE TO NEW DEFICIENCY ISSUED 9/5/2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 July 2008
Resolved
Remove all dead wiring
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2008
Resolution: CLEARED DUE TO NEW DEFICIENCY ISSUED 9/5/2008.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 31 July 2008
Resolved
Replace J box cover on hydraulic steering motor on stbd sede, engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 31 July 2008
Resolved
Properly secure panel boxes to aft E/R bulkhead behind generator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Fire Fighting › Fire Pumps › Suction Valve
Issued 31 July 2008
Resolved
Demonstrate proper operation of fire pump for marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2008
Fire Fighting › Fire Hydrants › Location/Position
Issued 31 July 2008
Resolved
Properly mount fire hose rack on port side at station
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 July 2008
Resolved
Store adult and child PFD's seperately and mark quantity on PFD locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 31 July 2008
Resolved
Renew retro on pFD's as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 July 2008
Resolved
Mark all PFD's with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 July 2008
Resolved
Discuss proper distribution of PFDs between 2 decks with MSD St Thomas Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 July 2008
Resolved
Complete all drills with operational crew with CG marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 July 2008
Resolved
Secure ladders to deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Operations/Management › Passenger Operations › Safety Orientation
Issued 31 July 2008
Resolved
Mark engine room hatch on main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 July 2008
Resolved
Provide proof of drug consortia enrollment for master and crewmembers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2008
Resolution: CLEARED DUE TO NEW DEFICIENCY ISSUED 9/5/2008.
Personnel › Training › First Aid/CPR
Issued 31 July 2008
Resolved
Provide valid CPR/first aid cards for 50% of the crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2008
Resolved 31 July 2008
Engineering › Bilge Water Management System › Valve
Issued 31 July 2008
Resolved
Properly label all bilge & other valves
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 July 2008
Resolved
Properly post COI & stability letter on bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 October 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Construction/Loadline › Structures › Scuttle
Issued 6 October 2006
Resolved
Remove fuel tank hatch on port deck & insert proper fuel tank acces no later than next hull exam (31MAR08).
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 22 July 2008
Fire Fighting › Fire Pumps › Location
Issued 6 October 2006
Resolved
Install & prove operation of self-priming, power driven fire pump complying with 46 CFR 181.300 & fire hose approved under UL 19. Hose should be at least 1.5 diameter and be at least 50 ft. Pump shall be capable of 50 GPM at 60 PSI and have a discharge gauge. pump should be tested in presence of marine inspector.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 6 October 2006
Lifesaving › Hand Flares › Expired
Issued 1 September 2006
Resolved
Provide proper distress flares and smoke signals as required by 46 CFR 180.68
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 September 2006
Resolved
Provide copy of navigation rules.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 September 2006
Resolved
Place original certificate of documentation onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 1 September 2006
Resolved
Obtain FCC radio operator's permit for Masters Theodore Otto Nicewonger and [name withheld] Lentine
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 1 September 2006
Resolved
Repair MF/HF/VHF radios on bridge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 1 September 2006
Resolved
Repair hydraulic leak under pilothouse console.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Bilge Water Management System › Pump
Issued 1 September 2006
Resolved
Repair or Renew bilge pump protecting #2 void space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Renew all watertight door gaskets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Renew watertight integrity in #2 void wiring penetrations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Lifesaving › Lifefloat › Markings
Issued 1 September 2006
Resolved
Mark lifefloats with vessel name and capacity; label paddles with vessel name.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Communications › Radio Communications › EPIRB
Issued 1 September 2006
Resolved
Renew EPIRB registration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 September 2006
Resolved
Install approved style/wattage light bulb for anchor light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 September 2006
Resolved
Provide correct fire extinguisher brackets for all fire extinguishers onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Renew Generator exhaust line in after compartment due to wastage and flooding.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Make proper permanent repairs to numerous drilled holes in deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Properly insert starboard aft quarter side shell to repair damage from penetrating injury to the satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2006
Resolved
Renew all non-marine grade, unapproved wiring on vessel IAW 46 CFR 183.340.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Fuel Oil Service System › Piping
Issued 1 September 2006
Resolved
Provide double hose clamps for each non-metallic piping installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 September 2006
Resolved
Install proper potable water piping deck penetration at starboard main deck passenger compartment head.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2006
Resolved
Remove spring clip wire connectors from starboard engine room battery installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Reinstall starboard engine room ventilation trunk main deck access cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 1 September 2006
Resolved
Double nut port/starboard propellor shaft and port/starboard rudder packing glands.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 1 September 2006
Resolved
Renew deadfront cover on engine room breaker panel, as per 46 CFR 183.330 and label all breakers in all panels througout vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Renew dog and adjust watertight door located in #2 void, which is found beneath snack bar area forward end of passenger compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2006
Resolved
Install insulation lagging to protect vessel personnel from exhaust surfaces exceeding 150 degrees F as per 46 CFR 177.970.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Bilge Water Management System › Valve
Issued 1 September 2006
Resolved
Label all bilge water valves as to their use, compartment protected, etc.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Fuel Oil Service System › Hose
Issued 1 September 2006
Resolved
All flexible non-metallic hose onboard vessel, permitted by 46 CFR 182.720, must meet SAE J-1942. Remove clear hose attached to fuel tank for priming filters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 1 September 2006
Resolved
Ensure vessel properly manned with 50% of crew CPR and First Aid qualified.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2006
Resolved
Install metal wire supports as per 46 CFR 183.340 on all wiring throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2006
Resolved
Professionally clean generator armature
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Seal engine room overhead access hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Lighting (service) › Switch
Issued 1 September 2006
Resolved
Renew light switch servicing #1 Void and properly mount. Existing light switch box has open penetrations allowing possible electricution hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 September 2006
Resolved
Clean engine room bulkheads, overhead, bilges and deck plating to remove oil residue and minimize possibility for personnel injury.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2006
Resolved
Install machinery guard for port propulsion engine in way of alternator drive belt.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Water on Deck › General
Issued 1 September 2006
Resolved
Make proper repairs to Air Conditioning plant located in #2 void. Sea water piping leaking into vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 1 September 2006
Resolved
Adjust/repack port and starboard propulsion shaft packing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Stability › Watertight Integrity › General
Issued 1 September 2006
Resolved
Submit repair proposal to MSU Houma for repair of holed, wasted deck underneath bar over #2 void.
Action required: 705 - Other - as specified
Resolved 6 October 2006
Resolution: C/R proper deck insert. Marine inspector witnessed DP test of insert.
Stability › Weathertight Integrity › General
Issued 1 September 2006
Resolved
Install proper grade and appropriate size hardware in all locations provided on all house windows
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2006
Resolved
Provide means to prevent batteries from shifting with roll and pitch of vessel in battery installations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Engineering › Fuel Oil Service System › Filter
Issued 1 September 2006
Resolved
Install caps/plugs on fuel oil filter drain bowls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 1 September 2006
Resolved
Failure to install fixed gas fire fighting system as per 46 CFR 181.410 and as required by SEC Charleston requirement dated 26 March 2006.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2006
Resolution: Engine shutdowns tested sat.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 September 2006
Resolved
Fax current consortium enrollment roster to marine isnpector.
Due 15 October 2006
Resolved 10 January 2007
Engineering › Steering Gear System › Linkage
Issued 20 April 2006
Resolved
a. Install double nuts or cotter pins in steering gear ram joints.
b. Ram Mounts worn resulting in approx 1/2 in play at joints. Repair/fill in worn area to original specifications to improve steering resposiveness.
Condition: Improper/Lack of Maintenance
Due 24 April 2006
Resolved 9 May 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 April 2006
Resolved
Keep an accurate & up to date record of required drills & training.
Condition: Unknown
Due 24 April 2006
Resolved 10 May 2006
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 20 April 2006
Resolved
Make permanent repair to fracture in bottom of fresh water tank.
Condition: Improper/Lack of Maintenance
Due 9 June 2006
Resolved 13 June 2006
Resolution: Repairs were carried out to the fresh water tank and there was no leakage observed.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 20 April 2006
Resolved
Clean engine room bilge of fuel.
Condition: Improper/Lack of Maintenance
Due 24 April 2006
Resolved 24 April 2006
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 20 April 2006
Resolved
Replace socket joints on throttle linkage.
Condition: Improper/Lack of Maintenance
Due 24 April 2006
Resolved 24 April 2006
Electrical › Electric Generation Source (service) › Generator
Issued 20 April 2006
Resolved
a. Install approved fuel lines & fittings.
b. Rewire with approved wiring, fasteners & wire brackets.
c. Remount gauge panel.
Condition: Improper Installation
Due 24 April 2006
Resolved 24 April 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 April 2006
Resolved
Install bilge high water alarm in lazarette.
Due 10 May 2006
Resolved 9 May 2006
Communications › Alarms/Indicators › General Alarm
Issued 20 April 2006
Resolved
Prove proper operation of PA system.
Due 24 April 2006
Resolved 24 April 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 April 2006
Resolved
Keep a record of testing & inspection of EPIRB & lifesaving equipment.
Due 9 June 2006
Resolved 13 June 2006
Resolution: Master provided a check sheet used to carry out visual inspections of all lifesaving craft.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2006
Resolved
Place a Coast Guard approved First Aid kit (or equivalent) on board the vessel. The contents must not be expired.
Due 10 May 2006
Resolved 9 May 2006
Personnel › Manning/Qualifications › Medical Fitness
Issued 20 April 2006
Resolved
Enroll Captain & crew in drug testing program to include company policy, pre-employment drug testing, random drug testing and EAP.
Due 10 May 2006
Resolved 9 May 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 April 2006
Resolved
Stow PFDs in proper/marked locations. Dispose of rejected PFDs.
Due 10 May 2006
Resolved 24 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2006
Resolved
Replace unapproved wiring throughout the vessel with CG approved wiring. All wiring must be properly braced in approve brackets.
Condition: Improper Installation
Due 9 June 2006
Resolved 10 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2006
Resolved
Replace/repair light fixtures throughout the vessel.
Due 10 May 2006
Resolved 9 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 20 April 2006
Resolved
Repair exhaust leak on service generator.
Due 9 June 2006
Resolved 13 June 2006
Resolution: Tested generator and observed no exhaust leaks during operation.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 20 April 2006
Resolved
Cable from generator to circuit breaker is chaffed. Replace with approved cable.
Due 9 June 2006
Resolved 13 June 2006
Resolution: Cable was replaced and properly installed.
Electrical › Electric Generation Source (service) › Panelboard
Issued 20 April 2006
Resolved
Generator pressure gauge is reading off scale (high). Make repair to generator & prove proper operation.
Due 9 June 2006
Resolved 13 June 2006
Resolution: Observed generator pressure gauge was operating properly and providing accurate readings.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 26 March 2006
Resolved
Replace Port and Starboard shaft and strut cutlass bearings, worn beyond 50 % and shows signs of misalignment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 26 March 2006
Resolved
Replace both bearing on rudders, and ensure no water intursion to lazerette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 27 March 2006
Construction/Loadline › Penetrations › Weld
Issued 26 March 2006
Resolved
Repair fractured support frame in the lazerette and pressure test the comparment to 1.5 psi to ensure no more water intrusion exists.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 29 March 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 March 2006
Resolved
No COI was posted on the vessel at the time of inspection. Post COI on vessel and ensure that it will not be destroyed by weather or mishandling.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 27 March 2006
Construction/Loadline › Structures › Superstructure
Issued 26 March 2006
Resolved
All Railing are in need of repair, aft port side need to be totally replaced to orginal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 29 March 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 26 March 2006
Resolved
Remount service generators guage panel and essentail wiring properly and use metal wire ties to secure wiring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 9 May 2006
Electrical › Lighting (service) › Switch
Issued 26 March 2006
Resolved
Improper Installation of Switch
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 27 March 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 26 March 2006
Resolved
Remove all un needed light fixtures, that were improperly installed in all the vessels compartments.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 27 March 2006
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 March 2006
Resolved
Replace all circuit breaker panel covers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Communications › Radio Communications › EPIRB
Issued 26 March 2006
Resolved
Renew EPIRB registration with NOAA
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2006
Resolved 27 March 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 26 March 2006
Resolved
Secure all wiring in the bridge correctly and remove all unneeded wiring and equipment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 27 March 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 26 March 2006
Resolved
Vessel has been brought up to NEW "T" regulations becuase of new Equipment installation and the certificate of inspection expiring this spring. The M/ V Carolina Clipper is now required to carry a fixed fire fighting system in the engine room.
Condition: Unknown
Due 11 September 2006
Resolved 6 October 2006
Stability › Unintentional Flooding › General
Issued 26 March 2006
Resolved
Excessive flooding in the lazerette , provide proof that flooding will not continiue and will be prevented in the future.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 29 March 2006
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 26 March 2006
Resolved
Ensure that spot light is in proper operatin condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 26 March 2006
Resolved
Name of vessel must be stenciled on the life floats and padels .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 March 2006
Resolved
Vessel needs a New to Zone Inspection when vessel arrives in Corpis Chirsty, TX
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2006
Resolved 9 May 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 8 February 2006
Resolved
Over load on ships generator with house hold wiring spread through out the entire vessels. Vessels power source is in quesiton on its operation ability.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 9 May 2006
Construction/Loadline › Penetrations › Weld
Issued 8 February 2006
Resolved
Vessel has a moderate water intrusion in the lazzarette!
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2006
Resolved 24 April 2006
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 20 April 2005
Resolved
Provide proper Discharge placerd in the engine room.
Due 13 May 2005
Resolved 6 May 2005
Resolution: New placard posted
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 April 2005
Resolved
Provide proper fuel shut-off valves as per 46CFR182.20-40(b)(3)
Due 13 May 2005
Resolved 6 May 2005
Resolution: Valve installed.
Fire Fighting › Fire Pumps › Arrangement
Issued 20 April 2005
Resolved
Make proper connections of wiring on both fire pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Proper connections made.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 April 2005
Resolved
Provide battery boxes for all batteries.
Due 13 May 2005
Resolved 6 May 2005
Communications › Visual Communication › Warning Sign (gangway)
Issued 20 April 2005
Resolved
Mark escape hatch and exit in the engine room.
Due 13 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 20 April 2005
Resolved
Make proper connection between 12-v battery and water pump in the the bathroom.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2005
Resolved
Make proper electrical connections to various wiring in engine room.
Due 13 May 2005
Resolved 6 May 2005
Engineering › Steering Gear System › Pump
Issued 20 April 2005
Resolved
Provide proper cap for hydraulic steering reservoirs.
Due 13 May 2005
Resolved 6 May 2005
Navigation › Piloting/Steering › Azimuth
Issued 20 April 2005
Resolved
Provide cover for auto pilot system electrical access.
Due 13 May 2005
Resolved 6 May 2005
Construction/Loadline › Hull › Bottom Plating
Issued 20 April 2005
Resolved
Properly cap hull penetration aft stbd engine room.
Due 13 May 2005
Resolved 6 May 2005
Engineering › Freshwater System (cylinder head cooling) › Discharge Strainer
Issued 20 April 2005
Resolved
Provide proper strainer baskets for main engine water intake.
Due 6 May 2005
Resolved 6 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 April 2005
Resolved
Provide proper guardds for rotating areas on main engines.
Due 6 May 2005
Resolved 6 May 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 20 April 2005
Resolved
Make penetrations in water tight bulkhead stbd, fwd engine room watetertight.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 April 2005
Resolved
Provide proper electrical fixtures for rod holder boxes on both sides of the engine room.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2005
Resolved
Provide proper covers for lighbulbs throughout the vessel.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Freshwater System (cylinder head cooling) › Valve, Control
Issued 20 April 2005
Resolved
Provide proper valve handle on stbd mde water intake.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 April 2005
Resolved
Provide proper blanks for open breakers in both power panel on the aft e/r bulkhead
Due 6 May 2005
Resolved 6 May 2005
Engineering › Fuel Oil Service System › Pump
Issued 20 April 2005
Resolved
Remove household switch from generator fuel pump.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Fuel Oil Service System › Valve
Issued 20 April 2005
Resolved
Provide proper connectors for emergency fuel shut-off rod valve. (nylocks)
Due 6 May 2005
Resolved 6 May 2005
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 April 2005
Resolved
Make proper connections for raw water discharge on generator. Heat exchanger to exhaust pipe.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 20 April 2005
Resolved
Provide proper air filter for emergency generator.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 20 April 2005
Resolved
Provide proper fuel supply and return lines for the generator.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 20 April 2005
Resolved
Remove restriction in generator fuel line. Discharge hose from filter is bent at a 90 degree angle.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electric Generation Source (service) › Generator
Issued 20 April 2005
Resolved
Prove proper operation of generator.
Due 6 May 2005
Resolved 6 May 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 20 April 2005
Resolved
Make repairs to the toilet which is leaking water into the engine room.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electric Generation Source (service) › Generator
Issued 20 April 2005
Resolved
Provide proper exhaust hoses for the generator.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 20 April 2005
Resolved
Make proper electrical connections for gullotine switch on the the side of the battery box.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 20 April 2005
Resolved
Provide chaffing gear for hydraulic lines outboard of the port engine.
Due 6 May 2005
Resolved 6 May 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 April 2005
Resolved
Provide plugs for the bottom of the electrical reel boxes on the main deck.
Due 6 May 2005
Resolved 6 May 2005
Fire Fighting › Fire Main › Valves
Issued 20 April 2005
Resolved
Provide proper handle for fire main riser on port side.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 20 April 2005
Resolved
Provide caps for spare hydraulic lines fwd enginee room between mains.
Due 6 May 2005
Resolved 6 May 2005
Engineering › Freshwater System (piston cooling) › Hose
Issued 20 April 2005
Resolved
Double clamp raw water pump hoses on both engines.
Due 6 May 2005
Resolved 6 May 2005
Construction/Loadline › Hull
Issued 24 February 2004
Resolved
G & W 4" fracture in weld IWO STBD side shell amidships. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Due 27 February 2004
Resolved 28 February 2004
Resolution: Corrected while on Dry Dock.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 February 2004
Resolved
Replace wasted MDE cable jacket beneath a/c unit. LEGACY COMPONENT DESC: Throttle cable jacket
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 9 April 2004
Resolution: This temporarily repaired. (W/L turned into CG-835).
Electrical › Electric Supply System (service)
Issued 24 February 2004
Resolved
Replace missing fuse box covers IWO steering complartment, e/r, mid-stoage compartment and forepeak. LEGACY COMPONENT DESC: Fuse boxes
Condition: Improper Installation
Due 27 February 2004
Resolved 9 April 2004
Resolution: Covers were installed.
Electrical › Electric Generation Source (service)
Issued 24 February 2004
Resolved
Remove dead-end wiring in e/r and crew compartment. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 27 February 2004
Resolved 9 April 2004
Resolution: Wires removed.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 24 February 2004
Resolved
Renew port and STBD shafts intermediate cutlass bearing. LEGACY COMPONENT DESC: Bearing
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 28 February 2004
Resolution: Corrected while on Dry Dock.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 February 2004
Resolved
Renew Port and STBD strut cutlass bearings. LEGACY COMPONENT DESC: Bearing
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 6 March 2004
Resolution: Corrected while on Dry Dock.
Engineering › Shafting/Propeller Arrangements
Issued 24 February 2004
Resolved
Renew both rudder bearings. LEGACY COMPONENT DESC: Rudder bearing
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 28 February 2004
Resolution: Corrected while on Dry Dock.
Engineering › Shafting/Propeller Arrangements
Issued 24 February 2004
Resolved
G & W fractures IWO both rudders. LEGACY COMPONENT DESC: Rudders.
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 28 February 2004
Resolution: Corrected while on Dry Dock.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 24 February 2004
Resolved
Properly repair Throttle cable jacket beneath a/c unite IWO center stoage compartment. LEGACY COMPONENT DESC: Throttle cable jacket
Condition: Improper/Lack of Maintenance
Due 16 April 2004
Resolved 23 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 February 2004
Resolved
Properly repair STBD MDE leaking raw water cooling pump. LEGACY COMPONENT DESC: raw water cooling
Condition: Improper/Lack of Maintenance
Due 16 April 2004
Resolved 23 May 2005
Fire Fighting › Fire Pumps
Issued 16 October 2003
Resolved
Port fire pump missing belt. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Lifesaving › Buoyant Apparatus
Issued 16 October 2003
Resolved
Life float lines deteriorated and the net wire was parted. Flost free arrangement of the life-float questionable as the painter line was on the deck intertwined with electrical wiring and it had the possibility of becoming entangled on the flood light casings.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Replace fuse box covers in lazarette LEGACY COMPONENT DESC: Fuse
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003
Resolved
Port main engine mount bolts loose and single bolted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2003
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 October 2003
Resolved
(7) Adult lifejackets and (4) child life jackets missing lights or lights inoperable LEGACY COMPONENT DESC: Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 October 2003
Resolved
Re-stencil lifejacket boxes with "Adult" or "Child" as appropriate and with the number of lifejackets. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Lifesaving › Lifebuoys
Issued 16 October 2003
Resolved
Life ring on the stern is not ready for immediate use and needs to be re-stenciled LEGACY COMPONENT DESC: Stowage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Communications › Radio Communications
Issued 16 October 2003
Resolved
Remove man overboard ladder to prevent damage to the EPIRB and to prevent failure of the float-free arrangement. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Fire Fighting › Remote Fuel Shutoff
Issued 16 October 2003
Resolved
Make proper repair and make operable the emergency fuel shut-off for the main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Communications › Alarms/Indicators
Issued 16 October 2003
Resolved
Properly secure high water level alarm in engine room LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Fire Fighting › Ventilation Systems
Issued 16 October 2003
Resolved
Properly route shore power cable out of engine room vent on the port side so as to allow proper closure of the vent in case of fire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Lifesaving › Lifejacket/PFD (General)
Issued 16 October 2003
Resolved
Properly secure lifejacket box on port side 01 deck forward. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Bilge Water Management System
Issued 16 October 2003
Resolved
Make proper repairs to reach rod for the bilge piping system valve in the forward void. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Make proper repairs to (14) electrical outlet boxes on the main deck LEGACY COMPONENT DESC: Outlet Box
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Electrical › Lighting (service)
Issued 16 October 2003
Resolved
Properly mount flood light on top of the wheel house forward. LEGACY COMPONENT DESC: Lighting Fixture
Due 16 November 2003
Resolved 30 October 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
make proper repairs to all spliced wiring throughout the vessel, especially in the engine room and on the 01 deck behind the wheel house. LEGACY COMPONENT DESC: Wiring
Due 16 November 2003
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Provide conduit for wire on the 01 deck running aft behind the lifejacket boxes on the deck. LEGACY COMPONENT DESC: Wiring
Due 16 November 2003
Resolved 30 October 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Make proper repairs to 01 deck flood light wiring. LEGACY COMPONENT DESC: Wiring
Due 16 November 2003
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Sea-water System (primary cooling)
Issued 16 October 2003
Resolved
Remove duct tape and make proper repairs to raw water intake hose LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Bilge Water Management System
Issued 16 October 2003
Resolved
make proper repairs to bilge discharge line. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Steering Gear System
Issued 16 October 2003
Resolved
Make proper repairs to starboard side hydraulic steering line. LEGACY COMPONENT DESC: Hydraulic Hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Engineering › Steering Gear System
Issued 16 October 2003
Resolved
Make proper repairs to cotter pin in ram port in the steering compartment. LEGACY COMPONENT DESC: Pin
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003
Resolved
Properly double clamp the following raw water lines:
1) Stbd main engine exhaust hoses. 2) Generator exhaust discharge port side. 3) Port MDE outboard exhaust cooling hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 October 2003
Resolved
Properly replace broken window stbd accomodadtion space 3rd window from fwd door
Due 16 November 2003
Resolved 30 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003
Resolved
Properly stow aft anchor
Due 16 November 2003
Resolved 30 October 2003
Accommodation/Occupational Safety
Issued 16 October 2003
Resolved
Properly stow/secure fish gaff away from passenger ladder.
Due 16 November 2003
Resolved 30 October 2003
Navigation › Electronic Positioning
Issued 16 October 2003
Resolved
Properly repair LORAN antenna on the upper deck LEGACY COMPONENT DESC: LORAN C Receiver
Due 16 November 2003
Resolved 30 October 2003
Communications › Audible Communications
Issued 16 October 2003
Resolved
Properly mount air horn on top of bridge LEGACY COMPONENT DESC: Horn/Whistle
Due 16 November 2003
Resolved 30 October 2003
Electrical › Lighting (service)
Issued 16 October 2003
Resolved
Make proper repairs to flood light stbd side facing aft, by the life float. Light fixture is wire tied. LEGACY COMPONENT DESC: Lighting Fixture
Due 16 November 2003
Resolved 30 October 2003
Communications › Radio Communications
Issued 16 October 2003
Resolved
Make proper reapairs to VHF antenna mount. LEGACY COMPONENT DESC: VHF Radiotelephone
Due 16 November 2003
Resolved 30 October 2003
Electrical › Lighting (service)
Issued 16 October 2003
Resolved
Make proper reapirs to or remove overhead light in lazarette LEGACY COMPONENT DESC: Lighting Fixture
Due 16 November 2003
Resolved 30 October 2003
Electrical › Electrical Distribution System (service) › Fuse
Issued 16 October 2003
Resolved
Make proper repairs to fuse box in the aft part of the engine room.
Due 16 November 2003
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Pollution Prevention/Response
Issued 16 October 2003
Resolved
Remove oily water from engine room bilges prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2003
Resolution: Cleared by [name withheld]
Fire Fighting › Fire Pumps › Impeller
Issued 29 July 2003
Resolved
Prove proper operation of power driven fire pump on starboard side, prior to carrying passengers
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2003
Resolution: vessel proved proper operation of fire pump to attending marine inspectors.
Electrical › Electrical Distribution System (service)
Issued 29 July 2003
Resolved
replace broken outlet box covers on deck LEGACY COMPONENT DESC: Outlet Box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 14 August 2003
Resolution: corrected sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 July 2003
Resolved
Replace rubber exhaust cooling water hose on port engine LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 14 August 2003
Resolution: corrected sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 July 2003
Resolved
properly seal exhaust leak on port and starboard engines located at exhaust manifold outlet. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 14 August 2003
Resolution: corrected sat
Electrical › Electric Supply System (service)
Issued 29 July 2003
Resolved
Properly secure battery in batter box of aft starboard engine room to prevent shifting. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 4 September 2003
Resolution: cleared sat
Fire Fighting › Fire Pumps
Issued 29 July 2003
Resolved
Make proper repair to automatic fire pump suction leak
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 14 August 2003
Resolution: corrected sat
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 July 2003
Resolved
Provide proper engine cooling water strainer on starboard side prior to carrying passengers
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2003
Resolution: corrected sat
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 July 2003
Resolved
Prove proper operation of high bilge alarm system prior to carrying passengers
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2003
Resolution: corrected sat
Electrical › Electrical Distribution System (service)
Issued 29 July 2003
Resolved
Provide blanks and proper door hinges for electrical distribution box LEGACY COMPONENT DESC: Switchboard
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 4 September 2003
Resolution: cleared sat
Operations/Management › Pollution
Issued 29 July 2003
Resolved
Remove all oil and oil residue from engine room and bilges. LEGACY COMPONENT DESC: Control of Discharge of Oil
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 4 September 2003
Resolution: cleared sat
Electrical › Electrical Distribution System (service)
Issued 29 July 2003
Resolved
remove dead end wiring in engine room LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 4 September 2003
Resolution: cleared sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 July 2003
Resolved
Prove proper operation of all steering gear and starboard engine machinery to the satisfaction of the attending marine inspector prior to carrying passengers. Upon satisfactory repairs, vessel must undergo sea trials with marine inspector. LEGACY COMPONENT DESC: Crankshaft
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2003
Resolution: cleared sat
Electrical › Electric Supply System (service)
Issued 3 June 2003
Resolved
Provide backing for batter in starboard battery box in engine room LEGACY COMPONENT DESC: Battery Installation
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Construction/Loadline › Structures
Issued 3 June 2003
Resolved
Make all watertight bulkhead penetrations watertight. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Electrical › Lighting (service)
Issued 3 June 2003
Resolved
Provide light covers for lights in engine room and deck LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2003
Resolved
Replace starboard exhaust hose (deformed) LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2003
Resolved
repair stbd engine valve cover gasket leak. LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 June 2003
Resolved
Provide 50% CPR certification for crew
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Navigation › Piloting/Steering
Issued 3 June 2003
Resolved
Provide required navigaion publications LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 3 June 2003
Resolved
provide legible wast management plan and post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 June 2003
Resolved
make proper attachment of lifering line to the lifering
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2003
Resolved
remove unused speakers and wires and all dead end wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Lifesaving › Buoyant Apparatus
Issued 3 June 2003
Resolved
provide proper sized weak link for all life floats LEGACY COMPONENT DESC: weak link
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 June 2003
Resolved
properly label child life jacket stowage compartment
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Communications › Radio Communications
Issued 3 June 2003
Resolved
provide proper radio equipment for route. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 4 July 2003
Resolution: corrected satisfactorily
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 3 June 2003
Resolved
Provide clear visibility and replace bridge window
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2003
Resolved 18 June 2003
Resolution: deficiency corrected sat
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 3 June 2003
Resolved
Remove all oil/oil residue from bilge and engine room prior to carrying passengers
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 July 2003
Resolution: engine room cleaned and oil/residue removed
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2003
Resolved
make permanent repairs to engine room ladder LEGACY COMPONENT DESC: Hand Grab
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 July 2003
Resolved 17 July 2003
Resolution: satisfactorily corrected
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 3 June 2003
Resolved
Prove proper shaft packing seal for port and starboard engines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2003
Resolved 4 July 2003
Resolution: corrected satisfactorily
Fire Fighting › Fire Pumps
Issued 3 June 2003
Resolved
Prove proper operation of starboard fire pump prior to carrying passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 July 2003
Resolution: corrected satisfactorily
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2003
Resolved
Replace lagging on starboard exhaust pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Resolution: satisfactorily corrected
Communications › Radio Communications › EPIRB
Issued 3 June 2003
Resolved
Ensure float free capabilities of EPIRB by relocating man overboard rescue ladder prior to carrying passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 July 2003
Resolution: corrected deficiency
Electrical › Electric Generation Source (service)
Issued 3 June 2003
Resolved
properly secure loose wiring coming off from starboard engine alternator LEGACY COMPONENT DESC: Conductor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Resolution: satisfactorily corrected
Electrical › Lighting (service)
Issued 3 June 2003
Resolved
Properly secure loose lighting wiring and switches in aft wheelhouse. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Resolution: satisfactorily corrected
Electrical › Electrical Distribution System (service)
Issued 3 June 2003
Resolved
Properly secure electrical hazards in engine room electrical distribution panel and shore connection box LEGACY COMPONENT DESC: Shore Connection Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Resolution: satisfactorily corrected
Engineering › Bilge Water Management System › Interface Detector
Issued 22 March 2002
Resolved
Properly mount and prove proper operation of high water bilge visual and audible alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 March 2002
Resolved
Properly replace ring buoy line and properly connect line to ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Lifesaving › Buoyant Apparatus
Issued 22 March 2002
Resolved
Properly secure lifefloat lines. LEGACY COMPONENT DESC: Lifefloat Lines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Fire Fighting › Fire Pumps › Pressure
Issued 22 March 2002
Resolved
Show proper operation of fire pump and pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Engineering › Bilge Water Management System › Piping
Issued 22 March 2002
Resolved
Make proper repairs and show proper operation of forward compartment bilge suction.
Action required: 705 - Other - as specified
Resolved 22 March 2002
Lifesaving › Hand Flares › Quantity
Issued 22 March 2002
Resolved
Provide additional three red hand held flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Communications › Radio Communications
Issued 22 March 2002
Resolved
Provide Emergency Bradcast Placard on the bridge. LEGACY COMPONENT DESC: Broadcast Placard
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 March 2002
Resolved
Provide current up to date Light List, Coast Pilot, Tide and Tidal Current Tables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Engineering › Freshwater Generation System › Pump
Issued 22 March 2002
Resolved
Properly secure potable water and sewage pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Lifesaving › Buoyant Apparatus
Issued 22 March 2002
Resolved
Properly repair to life basket inner net supports. LEGACY COMPONENT DESC: Supports
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 22 March 2002
Resolution: Temporary repairs made on March 22.
Electrical › Lighting (service)
Issued 22 March 2002
Resolved
Properly repair aft deck illumination light fixture. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 March 2002
Resolved
Properly repair starboard engine exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 19 November 2015
Resolution: Temporary repair made and tested on March 22.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 March 2002
Resolved
Properly secure overhead at entrance of engine room. LEGACY COMPONENT DESC: Engine Room Overhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Electrical › Electric Supply System (service)
Issued 22 March 2002
Resolved
Properly line all battery boxes and replace generator battery box. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Electrical › Electrical Distribution System (service)
Issued 22 March 2002
Resolved
Properly secure all dead end wiring. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Communications › Internal Communications System
Issued 22 March 2002
Resolved
Prove proper operation of vessel's public address system. LEGACY COMPONENT DESC: Public Address System
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2002
Electrical › Electrical Distribution System (service)
Issued 22 March 2002
Resolved
Properly secure main feed line to 12 volt distribution panel and secure box. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Electrical › Electrical Distribution System (service)
Issued 22 March 2002
Resolved
Properly secure main electrical distribution box cover aft engine room. LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Personnel › Training
Issued 22 March 2002
Resolved
Conduct man overboard and fire drills. LEGACY COMPONENT DESC: Personal Safety/Social Responsibilities
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 3 June 2003
Resolution: Drills were talked through. Actual man overboard drill using Oscar dummy to be performed.
Engineering
Issued 26 April 2001
Resolved
REPAIR EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Documentation
Issued 26 April 2001
Resolved
PROVIDE PROOF OF CPR TRAINING TO 50% OF CREW_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Lifesaving
Issued 26 April 2001
Resolved
RESTENCIL ADULT PFD STOWAGE CONTAINERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Lifesaving
Issued 26 April 2001
Resolved
RESTRICTED TO 112 PASSENGERS ON LIMITED COASTWISE ROUTE UNTIL RETROFLECTIVETAPE IS APPLIED TO ADDITIONAL 37 ADULT PFDS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Lifesaving
Issued 26 April 2001
Resolved
PROPERLY AFFIX 3 TO 6' LANYARD TO RING LIFE BUOY WATERLIGHT WITH ATTACHABLECLIP.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Accommodation/Occupational Safety
Issued 26 April 2001
Resolved
PROPERLY STENCIL MAX CAPACITY OF UPPER DECK (50 PASSENGERS).
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Electrical
Issued 26 April 2001
Resolved
PLACE COVER ON PORT STERN OUTLET.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Construction/Loadline
Issued 26 April 2001
Resolved
PROVE PROPER OPERATION OF BOTH HIGH LEVEL BILGE ALARM SYSTEMS.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Navigation
Issued 26 April 2001
Resolved
PROVE PROPER OPERATION OF HORN.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Electrical
Issued 26 April 2001
Resolved
INSTALL BLANKS TO ELECTRICAL PANEL IN ENGINE ROOM.
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Lifesaving
Issued 26 April 2001
Resolved
RESTRICTED TO 14 CHILD PASSENGERS UNTIL ONE ADDITIONAL CHILD PFD IS ACQUIRED.
Condition: Unknown
Due 14 May 2001
Resolved 16 May 2001
Engineering
Issued 26 April 2001
Resolved
DOUBLE CLAMP RAW WATER INTAKE ON STARBOARD ENGINE.
Condition: Unknown
Due 26 April 2001
Resolved 27 April 2001
Lifesaving
Issued 11 April 2000
Resolved
Replace battery in ring buoy water light (aft).
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Patch all cracks in life floats where white foam is exposed.
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Stencil maximum number of passengers allowed on upper deck in area visible to passengers.
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Electrical
Issued 11 April 2000
Resolved
Install circuit panel blank in empty circuit space in engine room distribution panel.
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Vessel passenger capacity reduced to 100 adults and 13 children until lifejackets replaced as indicated on item 3 (835).
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Replace/repair life jackets as indicated by marine inspector (48 adult and 2 childrens)
Condition: Unknown
Due 1 May 2000
Resolved 19 April 2000
Lifesaving
Issued 10 February 1999
Resolved
Update lifejacket box numbers per box, to reflect correct quantity stored.
Condition: Unknown
Due 17 February 1999
Resolved 29 April 1999
Documentation
Issued 10 February 1999
Resolved
Provide a logbook for drills and exercises.
Condition: Unknown
Due 17 February 1999
Resolved 29 April 1999
Electrical
Issued 10 February 1999
Resolved
Hardwire or remove floodlights above pilot house and galley.
Condition: Unknown
Due 17 February 1999
Resolved 29 April 1999
Lifesaving
Issued 10 February 1999
Resolved
Label escape hatch for engine room.
Condition: Unknown
Due 17 February 1999
Resolved 29 April 1999
Construction/Loadline
Issued 18 February 1997
Resolved
REPAIR FRACTURED WELD AT CHINE LOG AND COLLISION BULKHEAD IN THE FOREPEAK.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 28 February 1996
Resolved
LAZARETTE: REPAIR FRACTURED WELD ON STARBOARD KEELSON AT TRANSOM.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
FOREPEAK: REPAIR CRACK IN STARBOARD CHINE LOG AT THE COLLISION BULKHEAD.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
ENGINE ROOM: REPAIR FRACTURED WELD AT BRACKET ON STARBOARD OUTBOARD ENGINE BED.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
ENGINE ROOM: REPAIR CRACKED WELD ON #1 SIDE LONGITUDINAL AFT OF ENGINE ROOMWEB FRAME #4.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
ENGINE ROOM: REPAIR FRACTURED WELD ON OUTBOARD SIDE OF PORT ENGINE BED.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
LAZARETTE: REPAIR THREE FRACTURED WELDS ON PORT RUDDER SUPPORT BRACKET.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Accommodation/Occupational Safety
Issued 28 February 1996
Resolved
REPLACE WASTED PIPE BETWEEN THE HOLDING TANK AND THE OVERBOARD VALVE.
Condition: Unknown
Due 22 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 28 February 1996
Resolved
FOREPEAK: REPAIR CRACKED WELD IN VERTICAL STIFFENER ON COLLISION BULKHEAD (JUST BENEATH HATCH).
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
ADD BOTTOM LONGITUDINAL FRAMES BETWEEN LONGITUDINAL FRAMES 3P & S AND THE_x001C_ PORT AND STBD CHINE LOGS. MATCH WITH THE LONGITUDINAL FRAMES IN #1 FWD HOLDON OPPOSITE SIDE OF THE COLLISION BULKHEAD (58" UP FROM KEEL AT COLLISION BULKHEAD).
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
#2 COMPARTMENT: REPAIR FRACTURED WELD AT PORT KEELSON (BUTT ENDS OF 2 PIECES).
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
FOREPEAK: ADD A PARTIAL BULKHEAD AT WEB FRAME 3.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
#1 FORWARD COMPARTMENT: REPAIR FIVE FRACTURED WELDS IN THE COMPARTMENT AS MARKED BY INSPECTOR.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
#2 COMPARTMENT: REPAIR FRACTURED WELD ON PORT SIDE AT MAIN DECK.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 28 February 1996
Resolved
ENGINE ROOM: REPAIR FRACTURED WELD AT FORWARD END OF STARBOARD OUTBOARD ENGINE BED AT FORWARD ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Lifesaving
Issued 28 February 1996
Resolved
PROVIDE LIGHTS FOR 50 ADULT LIFE JACKETS. PROVIDE 26 NEW ADULT LIFE JACKETS. PROVIDE 3 NEW CHILD LIFE JACKETS. VESSEL IS NOT TO CARRY MORE THAN72 ADULTS AND 12 CHILDREN UNTIL DEFICIENCIES CORRECTED.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Lifesaving
Issued 28 February 1996
Resolved
CONDUCT UNDERWAY MAN OVERBOARD AND FIRE DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Engineering
Issued 28 February 1996
Resolved
PROVIDE MACHINE GUARDS FOR THE BELTS ON THE PORT AND STARBOARD ENGINES.
Condition: Unknown
Due 22 March 1996
Resolved 7 March 1996
Engineering
Issued 28 February 1996
Resolved
REPAIRED FRACTURED WELD ON PORT ENGINE BED TAB.
Condition: Unknown
Due 22 March 1996
Resolved 7 March 1996
Lifesaving
Issued 23 February 1995
Resolved
RENEW 64 EXPIRED PFD WATER ACTIVATED LIGHT BATTERIES NO LATER THAN 23MAR95.PASSENGER CAPACITY IS LIMITED TO 84 UNTIL BATTERIES ARE RENEWED AND INSPECTED BY A C.G. MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Lifesaving
Issued 13 February 1992
Resolved
PROVIDE VESSEL WITH RESCUE PLATFORM NO LATER THAN 30MAR92._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 20 February 1991
Resolved
VESSEL IS RESTRICTED TO 108 TOTAL PERSONS UNTIL 40 ADDITIONAL ADULT PFDs ARE PROVIDED.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Engineering
Issued 20 February 1991
Resolved
INSTALL ADDITIONAL LAGGING ON BOTH MAIN ENGINE EXHAUSTS NO LATER THAN 04MAR91.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Engineering
Issued 20 February 1991
Resolved
INSTALL FLAME SCREEN ON FUEL VENT PRIOR TO CARRYING PASSENGERS, AND IN NO CASE LATER THAN 01MAR91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Lifesaving
Issued 20 February 1990
Resolved
PROVIDE 65 ADULT & 5 CHILD PFD'S WITH LIGHTS TO MAKE TOTAL 149 ADULT & 15 CHILD PFD'S.VSL LIMITED TO 85 MAX PERSONS UNTIL REQUIREMENT COMPLETE.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE PERSONAL FLOATION DEVICE LIGHTS FOR 36 ADULT PFD'S
Condition: Unknown
Due 22 February 1989
Resolved 22 February 1989
Construction/Loadline
Issued 9 February 1988
Resolved
PROVIDE METALLIC VALVE ON FRESH WATER PVC PIPING THRU THE LAZZARETTE FWD BULKHEAD.
Condition: Unknown
Due 9 February 1988
Resolved 9 February 1988
Electrical
Issued 9 February 1988
Resolved
LAG GENERATOR EXHAUST LINE TO WATER INJECTION.
Condition: Unknown
Due 9 February 1988
Resolved 9 February 1988
Construction/Loadline
Issued 20 February 1985
Resolved
CAULK AROUND FRESH WATER PIPE PENETRATING AFTER BULKHEAD.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985