MAURY USCG vessel records
← All vessels

EDEN STAR

Built
1975
Last inspected
7 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL5473
Flag
UNITED STATES
Maury page id
psix-51459

Documentation record

Registered dimensions (L × B × D)61.7 ft × 21.7 ft × 6.9 ft
Registered tonnagegross 55 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBAR HARBOR, ME
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 63 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

7 May 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8353539
7 May 2025 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8108751
19 November 2024 Simplified Stability Test
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8036900
19 September 2023 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7795147
12 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7660451
16 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7428501
21 March 2022 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7415736
25 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7296126
29 March 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7164506
12 May 2020 COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6951903
12 February 2020 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6937851
6 November 2019 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6851116
13 September 2018 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6533661
30 May 2018 Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6428276
30 November 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6315385
13 October 2017 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6288348
19 October 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6025937
11 May 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5874336

Deficiency record · 63

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2026 Resolved
Found gen set not connected to Fire Boy shut down system. Repair system of based on availability of parts and attendance of service technician
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Obtained parts and connected unit to shut down system, test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 June 2022 Resolved
Install door alarm with open/closed indication and post required signage on door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 23 June 2022
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 May 2021 Resolved
Replace expired battery. Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 25 June 2021
Resolved 16 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021 Resolved
Provide Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021 Resolved
Provide brackets for two portable extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 25 May 2021 Resolved
Make watertight all WTB openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021 Resolved
Install guards on MDEs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021 Resolved
Address issue with breather on port MDE.
Action required: 705 - Other - as specified
Due 8 June 2021
Resolved 25 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021 Resolved
Label Bilge manifold system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 May 2021 Resolved
Label upper deck pax limit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021 Resolved
Prove operation of engine driven pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2019 Resolved
Properly repair two soft patches in the fire main aft of the starboard engine just off the fire pump with solid piping or approved flexible hose with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Piping replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 November 2019 Resolved
Fuel shutoff valve is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2020
Resolution: New valve installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2019 Resolved
Fuel lines on bot engines are wasted, crimped, not in serviceable condition. Replace with proper, approved hoses with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: fuel lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019 Resolved
Poperly repair both engine exhaust pipes. Both are heavily corroded and both have improper repairs on them.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: new piping installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019 Resolved
Life-float placed out of service. Lines are wasted and there is paint covering the approval label.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: Vessel route is updated for sector NNE LBS plus LCW not more than 20 miles from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2019 Resolved
Properly stow lifejackets and mark stowage according to the regulations. Marking is faded and some lifejackets are stowed below decks in garbage bags.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Lifejacket stowage restenciled
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 November 2019 Resolved
First Aid kit is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Updated first aid kit provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019 Resolved
Bilge valve forward of collision bulkhead inoperative.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: new valve installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019 Resolved
Drug and Alcohol Program verification not available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: DAPI information provided for current crew
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 November 2019 Resolved
Did not conduct man overboard drill. Questioned the crew about the use of the EPIRB and neither crew knew how to test or operate the EPIRB in case of an emergency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Satisfactory drills conducted.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019 Resolved
Properly repair leak in hydraulic fluid tank/hoses/fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New hoses installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2019 Resolved
Generator exhaust has a leak through a wasted pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New piping installed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2019 Resolved
Port side hull iwo the storage compartment under the operating station near the aft bulkhead had an indentation and possible hull crack. There is also an improper doubler strip in the same area from a prior repair. Crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Hull was not cheaked from the outside. Welds were veed abnd re-welded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019 Resolved
Remove oil saturated wood from underneath the battery box and the generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Oil soaked wood removed
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2019 Resolved
Properly clean the bilges in the engine room and lazarette and make available for proper inspection of widespread pitting in the hull plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Bilges were cleaned
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2019 Resolved
All around light is inoperative, possibly due to wasted wiring and the mast for the light is broken at the weld at the top of the house. repair broken mast and provide a working all around light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Mast head light provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019 Resolved
Properly repair electrical wiring throughout the entire vessel. There are numerous open electrical boxes (in engine room, outside on the open decks and under the operating station). Dead-end wires are prevalent throughout the vessel and wiring is connected with electrical tape in several areas such as the bilge high water alarm in the engine room. Numerous deck lights are duct taped in place to hold them up. There are extension cords being used as permanent wire (under the operating station and in the engine room on the starboard side. All electrical connections must be done with proper crimped or screwed ends into junction boxes with the proper boat cable used.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Dead end wiring removed.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 6 November 2019 Resolved
Replace all sun faded and cloudy bridge windows.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 29 November 2019
Resolution: Received photos from owner. All bridge windows replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Make battery charger connection to battery on bridge a permanent type connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Permanent connections installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Remove all dead-end wires from being the helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all dead end wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Make all wire connections iaw 46CFR183.340(g), (H) or (i).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all incorrect connections removed or peroperly repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Remove or protect fuse panel in way of bridge battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New breaker pannel installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 September 2018 Resolved
Permanently mount EPIRB housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Remove derelict air conditioner unit from upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018 Resolved
Provide (03) adult life jackets. Vessel restricted to carriage of 125 total persons until cleared.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New PFDs installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Make proper wire connections for main-deck air conditioner unit and provide junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: A/C removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Provide switch and over current protection of MSD macerator pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New switch and fuse installed.
Lifesaving › Lifefloat › Serviceable
Issued 30 November 2017 Resolved
Replace or make permanent repairs to damaged life float.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 16 January 2018
Resolution: Lifefoat repaired and painted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2017 Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: First aid kit updated.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 November 2017 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Emergency Instructions posted.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 30 November 2017 Resolved
Replace starboard transmission cable.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Cable properly repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 November 2017 Resolved
Prove proper operation of mast lights.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Nav lights properly working.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 November 2017 Resolved
Prove proper operation of lazarette bilge high water alarm (buzzer).
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Bilge alarm properly alarming.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 November 2017 Resolved
Provide covers for battery boxes.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Battery boxes properly covered.
Engineering › Steering Gear System › Hydraulic Hose
Issued 30 November 2017 Resolved
Repair leaks on hydraulic steering system in Engine Room and seal on steering ram.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 January 2018
Resolution: Leak repaired
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 November 2017 Resolved
Prove proper operation of fireboy engine shutdowns.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Fireboy shut-down properly working.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 20 October 2016 Resolved
Demonstrate proper machinery and ventilation shut-downs with fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: Shut-downs satisfactorily demonstrated.
Engineering › Bilge Water Management System › Pump
Issued 20 October 2016 Resolved
Prove proper operation of bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Tested bilge system, found to be in satisfactory condition.
Communications › Visual Communication › Red Warning Signal
Issued 20 October 2016 Resolved
Provide a total of 6 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: All required signaling devices on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2016 Resolved
Provide current first-aid kit.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Firstaid kit renewed with current items.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2016 Resolved
Provide guard for generator fan belt.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Guard installed on generator fan belt.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 October 2016 Resolved
Renew retroreflective tape on identified life jackets.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Retro reflective tape renewed on identified life jackets.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2016 Resolved
Properly label lifejacket storage.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Life jacket storage properly labeled.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 October 2016 Resolved
Properly secure electrical outlet in steering gear room.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Electrical outlet properly secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 October 2016 Resolved
Repair or remove distribution box on aft bulkhead of bridge.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Junction box properly repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2016 Resolved
Provide proper wiring from bridge A/C unit and main cabin reefer.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Extension cord removed from reefer and AC properly wired.
Documentation › Markings/Placards › Garbage Placard
Issued 20 October 2016 Resolved
Provide current MARPOL V placard.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: MARPOL placard updated.
Communications › Radio Communications › Emergency Source of Power
Issued 20 October 2016 Resolved
Remove excess wiring on bridge battery.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Excess wires removed from battery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 October 2016 Resolved
Properly secure bridge and engine room batteries.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 23 November 2016
Resolution: Batteries properly secured.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2016 Resolved
Provide updated Coast Pilot [name withheld] and Light List.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publications updated.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2016 Resolved
Provide Rules of the Road.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publication updated.
Communications › Radio Communications › EPIRB
Issued 20 October 2016 Resolved
Provide current hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: New hydrostatic release installed.

Recorded names · 1

INDEPENDENT SEA (2010–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.