07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2026
Resolved
Found gen set not connected to Fire Boy shut down system. Repair system of based on availability of parts and attendance of service technician
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Obtained parts and connected unit to shut down system, test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 June 2022
Resolved
Install door alarm with open/closed indication and post required signage on door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 23 June 2022
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 May 2021
Resolved
Replace expired battery. Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 25 June 2021
Resolved 16 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 May 2021
Resolved
Provide Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2021
Resolved
Provide brackets for two portable extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 25 May 2021
Resolved
Make watertight all WTB openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
Install guards on MDEs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021
Resolved
Address issue with breather on port MDE.
Action required: 705 - Other - as specified
Due 8 June 2021
Resolved 25 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 May 2021
Resolved
Label Bilge manifold system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 May 2021
Resolved
Label upper deck pax limit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021
Resolved
Prove operation of engine driven pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 15 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2019
Resolved
Properly repair two soft patches in the fire main aft of the starboard engine just off the fire pump with solid piping or approved flexible hose with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Piping replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 November 2019
Resolved
Fuel shutoff valve is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2020
Resolution: New valve installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2019
Resolved
Fuel lines on bot engines are wasted, crimped, not in serviceable condition. Replace with proper, approved hoses with approved fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: fuel lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
Poperly repair both engine exhaust pipes. Both are heavily corroded and both have improper repairs on them.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: new piping installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019
Resolved
Life-float placed out of service. Lines are wasted and there is paint covering the approval label.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2020
Resolution: Vessel route is updated for sector NNE LBS plus LCW not more than 20 miles from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2019
Resolved
Properly stow lifejackets and mark stowage according to the regulations. Marking is faded and some lifejackets are stowed below decks in garbage bags.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Lifejacket stowage restenciled
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 November 2019
Resolved
First Aid kit is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Updated first aid kit provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019
Resolved
Bilge valve forward of collision bulkhead inoperative.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: new valve installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019
Resolved
Drug and Alcohol Program verification not available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: DAPI information provided for current crew
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 November 2019
Resolved
Did not conduct man overboard drill. Questioned the crew about the use of the EPIRB and neither crew knew how to test or operate the EPIRB in case of an emergency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Satisfactory drills conducted.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019
Resolved
Properly repair leak in hydraulic fluid tank/hoses/fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New hoses installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2019
Resolved
Generator exhaust has a leak through a wasted pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: New piping installed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2019
Resolved
Port side hull iwo the storage compartment under the operating station near the aft bulkhead had an indentation and possible hull crack. There is also an improper doubler strip in the same area from a prior repair. Crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Hull was not cheaked from the outside. Welds were veed abnd re-welded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2019
Resolved
Remove oil saturated wood from underneath the battery box and the generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Oil soaked wood removed
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2019
Resolved
Properly clean the bilges in the engine room and lazarette and make available for proper inspection of widespread pitting in the hull plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Bilges were cleaned
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2019
Resolved
All around light is inoperative, possibly due to wasted wiring and the mast for the light is broken at the weld at the top of the house. repair broken mast and provide a working all around light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Mast head light provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2019
Resolved
Properly repair electrical wiring throughout the entire vessel. There are numerous open electrical boxes (in engine room, outside on the open decks and under the operating station). Dead-end wires are prevalent throughout the vessel and wiring is connected with electrical tape in several areas such as the bilge high water alarm in the engine room. Numerous deck lights are duct taped in place to hold them up. There are extension cords being used as permanent wire (under the operating station and in the engine room on the starboard side. All electrical connections must be done with proper crimped or screwed ends into junction boxes with the proper boat cable used.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Dead end wiring removed.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 6 November 2019
Resolved
Replace all sun faded and cloudy bridge windows.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2019
Resolved 29 November 2019
Resolution: Received photos from owner. All bridge windows replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make battery charger connection to battery on bridge a permanent type connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Permanent connections installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove all dead-end wires from being the helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all dead end wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make all wire connections iaw 46CFR183.340(g), (H) or (i).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2018
Resolution: Received report from electrician that all incorrect connections removed or peroperly repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove or protect fuse panel in way of bridge battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New breaker pannel installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 September 2018
Resolved
Permanently mount EPIRB housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Remove derelict air conditioner unit from upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018
Resolved
Provide (03) adult life jackets. Vessel restricted to carriage of 125 total persons until cleared.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New PFDs installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Make proper wire connections for main-deck air conditioner unit and provide junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: A/C removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018
Resolved
Provide switch and over current protection of MSD macerator pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: New switch and fuse installed.
Lifesaving › Lifefloat › Serviceable
Issued 30 November 2017
Resolved
Replace or make permanent repairs to damaged life float.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 16 January 2018
Resolution: Lifefoat repaired and painted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2017
Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: First aid kit updated.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 November 2017
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Emergency Instructions posted.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 30 November 2017
Resolved
Replace starboard transmission cable.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Cable properly repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 November 2017
Resolved
Prove proper operation of mast lights.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Nav lights properly working.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 November 2017
Resolved
Prove proper operation of lazarette bilge high water alarm (buzzer).
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Bilge alarm properly alarming.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 November 2017
Resolved
Provide covers for battery boxes.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Battery boxes properly covered.
Engineering › Steering Gear System › Hydraulic Hose
Issued 30 November 2017
Resolved
Repair leaks on hydraulic steering system in Engine Room and seal on steering ram.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 16 January 2018
Resolution: Leak repaired
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 November 2017
Resolved
Prove proper operation of fireboy engine shutdowns.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Fireboy shut-down properly working.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 20 October 2016
Resolved
Demonstrate proper machinery and ventilation shut-downs with fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: Shut-downs satisfactorily demonstrated.
Engineering › Bilge Water Management System › Pump
Issued 20 October 2016
Resolved
Prove proper operation of bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Tested bilge system, found to be in satisfactory condition.
Communications › Visual Communication › Red Warning Signal
Issued 20 October 2016
Resolved
Provide a total of 6 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 24 October 2016
Resolution: All required signaling devices on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2016
Resolved
Provide current first-aid kit.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Firstaid kit renewed with current items.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2016
Resolved
Provide guard for generator fan belt.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Guard installed on generator fan belt.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 October 2016
Resolved
Renew retroreflective tape on identified life jackets.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Retro reflective tape renewed on identified life jackets.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 October 2016
Resolved
Properly label lifejacket storage.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: Life jacket storage properly labeled.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 October 2016
Resolved
Properly secure electrical outlet in steering gear room.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Electrical outlet properly secured.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 October 2016
Resolved
Repair or remove distribution box on aft bulkhead of bridge.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Junction box properly repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2016
Resolved
Provide proper wiring from bridge A/C unit and main cabin reefer.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Extension cord removed from reefer and AC properly wired.
Documentation › Markings/Placards › Garbage Placard
Issued 20 October 2016
Resolved
Provide current MARPOL V placard.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: MARPOL placard updated.
Communications › Radio Communications › Emergency Source of Power
Issued 20 October 2016
Resolved
Remove excess wiring on bridge battery.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 30 November 2016
Resolution: Excess wires removed from battery.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 October 2016
Resolved
Properly secure bridge and engine room batteries.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 23 November 2016
Resolution: Batteries properly secured.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2016
Resolved
Provide updated Coast Pilot [name withheld] and Light List.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publications updated.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 October 2016
Resolved
Provide Rules of the Road.
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 17 November 2016
Resolution: Publication updated.
Communications › Radio Communications › EPIRB
Issued 20 October 2016
Resolved
Provide current hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 24 October 2016
Resolution: New hydrostatic release installed.