MAURY USCG vessel records Sign in
← All vessels

MISS AUBREY ANN

MISS AUBREY ANN is a 1980 offshore supply vessel. The Coast Guard has recorded 47 inspections since 1982, most recently in November 2015, along with 70 deficiencies and 2 casualty investigations between 2007 and 2008.

Records from 1982 to 2015. Most recent: inspection, 12 November 2015.

Built
1980
Last inspected
12 November 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9897
Flag
UNITED STATES
367068850, 367172250, 367490390, 367509960 (licence lapsed)
Maury page id
psix-51486

Inspections, by type

…with no type recorded7
Years with a record 27 calendar years (1982–2015)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF9897MMSI 367509960 · expired · compulsorily equipped · granted 18 November 2011, cancelled 22 January 2022
WDF8006MMSI 367490390 · expired · compulsorily equipped · granted 14 May 2011, cancelled 17 July 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDD6387MMSI 367172250 · expired · compulsorily equipped · granted 10 March 2007, cancelled 13 May 2017
WDC7270MMSI 367068850 · expired · compulsorily equipped · granted 27 September 2005, cancelled 28 November 2015 · licensed under a name not among this hull’s recorded names (not shown)
WYQ6957MMSI not assigned · expired · compulsorily equipped · granted 12 January 1995, cancelled 28 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ARIEL Passenger (Inspected) · MISLE 54041 · 13 December 1996 · activity 146326

Inspection history · 47

12 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762510
16 November 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3892344
21 October 2010 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3874570
28 July 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3548678
9 July 2008 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3263540
2 July 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3260805
2 July 2008 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3267651
25 January 2008 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3136502
8 November 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3095224
23 July 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3004719
21 July 2007 Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3002418
18 July 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2999922
3 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2900496
18 May 2006 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2666378
27 September 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2502511
12 January 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2273355
21 November 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1952165
22 April 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1778203
6 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1726349
14 December 2001 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1476656
17 May 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423578
3 October 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436458
25 July 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051386
5 May 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452512
7 May 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427540
9 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467011
24 December 1996 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100883
13 December 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 146326
13 December 1996 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092603
1 May 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459993
14 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077987
14 March 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449798
14 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374025
27 May 1993 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366852
6 May 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947347
8 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359389
14 May 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241409
2 July 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243186
9 April 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910957
6 March 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890661
17 January 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208143
5 May 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352190
28 April 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329694
30 April 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998869
3 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292003
7 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280363
29 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279748

Deficiency record · 70

Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 October 2010 Resolved
Vessel was found to be operating with an expired COI
Due 21 October 2010
Resolved 22 October 2010
Resolution: Vsl conducted COI inspection.
Electrical › Electric Generation Source (service) › Generator
Issued 28 July 2009 Resolved
Generator overspeed trips not operating properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2009
Resolution: Witnessed generator overspeed trip.
Electrical › Electric Generation Source (service) › Panelboard
Issued 28 July 2009 Resolved
Generator AMP meters not working.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2009
Resolved 30 July 2009
Resolution: Had amp meters replaced, witnessed proper operation.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 July 2009 Resolved
Expired alcohol testing strips.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2009
Resolved 30 July 2009
Resolution: purchased new alcohol strips.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 28 July 2009 Resolved
Waterlight not operating properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2009
Resolved 30 July 2009
Resolution: Replaced light.
Lifesaving › Lifefloat › Float-free Link
Issued 28 July 2009 Resolved
No inspection tag on link. Could not verify size or capacity of link.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2009
Resolved 30 July 2009
Resolution: Replaced weak link.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2009 Resolved
Failure to provide local area chart.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2009
Resolved 30 July 2009
Resolution: Purchased updated chart.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 November 2007 Resolved
Provide additional railing for the rescue zone as required by 46 CFR 92.25-5
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 November 2007 Resolved
Submit fire control plan for approval as required by 46 CFR 91.55-1.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 November 2007 Resolved
Remove paint from main panel wood handle.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 November 2007 Resolved
Prove proper operation of all indicator lights on main panel
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 November 2007 Resolved
Adjust manual breaker interlock on main panel to prevent 2 breakers from being energized.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 November 2007 Resolved
Provide circuit directory for 208 volt panel located in engine room.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 November 2007 Resolved
Provide electrical matting for main distribution panel.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Engineering › Fuel Oil Service System › Piping
Issued 8 November 2007 Resolved
Repair leak on port generator fuel oil return line.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 8 November 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 November 2007 Resolved
Remove all oil, trash, and debris from the engine room bilges as required by 46 CFR 91.25-45.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 November 2007 Resolved
Number the breakers to match the circuit index for the main deck lighting panel.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 November 2007 Resolved
Provide retro for all life buoys and bottom life float as required by 46 CFR 199.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Communications › Radio Communications › EPIRB
Issued 8 November 2007 Resolved
Provide new hydrostatic release for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2007
Resolved 8 November 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2007 Resolved
Ensure all batteries are properly installed as required by 46 CFR 111.15-5.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 November 2007 Resolved
The use of twist on type connectors is limited to the requirements of 46 CFR 111.60-17, remove the wire nuts or provide an enclosure for connection at main air handler.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 November 2007 Resolved
Provide life jacket donning placard that matches on board life jackets.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 November 2007 Resolved
Provide correct mounting brackets for all stateroom fire extinguishers.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 28 November 2007
Construction/Loadline › Hull › Side Shell
Issued 21 July 2007 Resolved
Vessel was Issued an CG 835 to submit repair proposal to permanently repair damage to vessel IWO bow. Vessel was issued PTP to Superior Shipyard Golden Meadow LA to affect perm repairs.
Action required: 705 - Other - as specified
Resolved 7 November 2007
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 12 January 2005 Resolved
Provide and install proper anchor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 28 January 2005
Resolution: Provided proper anchor.
Fire Fighting › Firemans Outfit › Axe
Issued 12 January 2005 Resolved
Provide and install proper fire axe as per COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 28 January 2005
Resolution: Provided and mounted proper fire axe.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 January 2005 Resolved
Provide valid FCC radio operators license for captain.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 28 January 2005
Resolution: Provided valid radio license.
Deck/Cargo › Ballast
Issued 21 November 2003 Resolved
Renew vent on port side aft deck. LEGACY COMPONENT DESC: Vents
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 21 November 2003 Resolved
Install flame screens on all fuel vents.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Construction/Loadline › Structures › Door
Issued 21 November 2003 Resolved
Provide dogging wrench for aft main deck watertight door.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Deck/Cargo › Ballast › Vents
Issued 21 November 2003 Resolved
Provide ball check for #1 ballast tank.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Engineering › Steering Gear System › Pin
Issued 21 November 2003 Resolved
Install safety pins on steering gear.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Engineering › Bilge Water Management System › Valve
Issued 21 November 2003 Resolved
Stencil forepeak reach-rod.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Construction/Loadline › Structures
Issued 21 November 2003 Resolved
Renew gaskets and adjust pilothouse and aft main deck watertight doors. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Lifesaving › Hand Flares › Marking
Issued 21 November 2003 Resolved
Label distress signal container.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 November 2003 Resolved
Install high water alarm in the rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 November 2003 Resolved
Make repairs to and calibrate both rudder angle indicators.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Lifesaving › Buoyant Apparatus
Issued 21 November 2003 Resolved
Properly attach sea painter and weak link to life floats. LEGACY COMPONENT DESC: Life float
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Lifesaving › Buoyant Apparatus
Issued 21 November 2003 Resolved
Tether paddles to and renew float light for life floats. LEGACY COMPONENT DESC: Life floats
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 21 November 2003 Resolved
Renew 6 windows in the pilot house.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Fire Fighting › Fire Pumps › Pressure
Issued 21 November 2003 Resolved
Provide operational fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Fire Fighting › Miscellaneous Items
Issued 21 November 2003 Resolved
Remove flammables from compartment under pilothouse. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Electrical › Electrical Distribution System (emergency)
Issued 21 November 2003 Resolved
Clean, grease, and properly secure 12 volt batteries. LEGACY COMPONENT DESC: Battery
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 21 November 2003 Resolved
Renew 2 lifejackets and restencil 6 lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Deck/Cargo › Ballast › Valves
Issued 21 November 2003 Resolved
Label all vent pipes.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Fire Fighting › Fire Hoses
Issued 21 November 2003 Resolved
Label all fire hoses with vessel name. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Fire Fighting › Fire Hydrants
Issued 21 November 2003 Resolved
Label all fire stations as per the fire safety plan. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Lifesaving › Lifebuoys › Quantity
Issued 21 November 2003 Resolved
Renew port main deck lifebuoy.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 2 December 2003
Fire Fighting › Remote Fuel Shutoff
Issued 21 November 2003 Resolved
Properly label fuel shutoff valves. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Engineering › Fuel Oil Service System › Hose
Issued 21 November 2003 Resolved
Renew flexible fuel hose on port main engine.
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Communications › Internal Communications System
Issued 21 November 2003 Resolved
Make repairs to pilothouse sound-powered phone. LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 2 December 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 January 2003 Resolved
PROVIDE AND INSTALL FLAME SCREEN FOR SEWAGE TANK VENT. LEGACY COMPONENT DESC: Flame Screens
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 7 January 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 January 2003 Resolved
REPAIR GALLEY EMERGENCY LIGHT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 6 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 6 January 2003 Resolved
PROVIDE AND INSTALL TACHOMETERS FOR BOTH PORT AND STARBOARD SHAFTS. LEGACY COMPONENT DESC: SHAFT TACHOMETER
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 2 December 2003
Navigation › Piloting/Steering
Issued 6 January 2003 Resolved
CALIBRATE ENGINE ROOM AND PILOTHOUSE RUDDER ANGLE INDICATORS. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 2 December 2003
Fire Fighting › Nozzles › Condition
Issued 6 January 2003 Resolved
REPAIR OR RENEW ONE FIRE FIGHTING NOZZEL.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 6 January 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 6 January 2003 Resolved
PROVIDE AND INSTALL FLAME SCREENS FOR STBD FORWARD AND PORT AFT FUEL OIL VENT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 7 January 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 January 2003 Resolved
REPAIR OR RENEW TWO LIFEBUOY LIGHTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2003
Resolved 7 January 2003
Engineering › Bilge Water Management System
Issued 14 December 2001 Resolved
INSTALL HIGH WATER LEVEL ALARM IN THE RUDDER COMPT.
Condition: Unknown
Due 14 January 2002
Resolved 2 December 2003
Construction/Loadline › Penetrations
Issued 14 December 2001 Resolved
PROVIDE PROPER VENTS PLUGS LEGACY COMPONENT DESC: VENTS
Condition: Improper Installation
Due 14 December 2001
Resolved 14 December 2001
Construction/Loadline › Penetrations
Issued 14 December 2001 Resolved
PROPERLY REPAIR RUDDER ROOM VENT LEGACY COMPONENT DESC: VENT PIPING
Condition: Damaged By Earlier Event
Due 14 December 2001
Resolved 14 December 2001
Engineering › Bilge Water Management System › Manifold
Issued 14 December 2001 Resolved
PROPERLY LABEL BILGE MANIFOLD
Condition: Improper/Lack of Maintenance
Due 14 December 2001
Resolved 14 December 2001
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 December 2001 Resolved
INSTALL BATTERIES IN ALL EMERGECY LIGHTING
Condition: Improper/Lack of Maintenance
Due 14 December 2001
Resolved 14 December 2001
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 December 2001 Resolved
REPLACE BURNT BULBS IN ENGINE ROOM ALARM PANEL. LEGACY COMPONENT DESC: ALARM PANEL
Condition: Improper/Lack of Maintenance
Due 14 December 2001
Resolved 14 December 2001
Construction/Loadline
Issued 13 December 1996 Resolved
PROCEED DIRECTLY TO LAROSE S/Y, LA TO MAKE PERMANENT REPAIRS TO THE BOW. NOTIFY USCG MSD HOUMA UPON ARRIVAL.
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Engineering
Issued 8 April 1992 Resolved
COMPLY WITH CG-835 ISSURED 09APR90 TO INSTALL AND PROVE PROPER OPERATION OFMAIN ENGINE OVERSPEED TRIPS
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 9 April 1990 Resolved
RENEW AFT WINDOWS IN PILOT HOUSE DUE TO HAZING FROM SAND BLASTING.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Unknown
Issued 9 April 1990 Resolved
PROVIDE CURRENT COPY OF 46 CFR SUBCHAPTER "I".
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Accommodation/Occupational Safety
Issued 9 April 1990 Resolved
PROVE PROPER OPERATION OF STOVE VENT HOOD FAN.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Engineering
Issued 9 April 1990 Resolved
INSTALL AND PROVE PROPER OPERATION OF ENGINE OVERSPEED TRIPS ON MAIN ENGINES.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990

Casualty record · 2

18 July 2007Routine · role: Involved in a Marine Casualty · activity 2999922
2 July 2008Routine · role: Involved in a Marine Casualty · activity 3260805
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GUY C (2007–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.