Inspection history · 60
13 June 2011
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4045472
24 November 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3897596
8 July 2008
Annual Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3261266
4 December 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3108882
17 September 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3059628
4 September 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3050475
17 August 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3030816
29 June 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2984181
13 October 2006
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2799750
31 July 2006
Internal Structural Exam · MTSA Verification · Administrative Inspection · Cargo Tank Internal · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2731496
25 May 2006
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2658582
21 July 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2434093
15 November 2004
MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2241203
23 June 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2107802
21 May 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2073841
23 July 2003
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1845662
3 July 2003
Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1833373
13 August 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1661280
16 July 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1647331
20 August 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1070444
23 May 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070645
23 May 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426598
9 May 2001
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1064753
8 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 33113
8 January 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058985
22 February 2000
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1457781
16 March 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436182
6 February 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1469499
30 January 1998
Examination of Repairs · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437348
4 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 185567
8 April 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1385957
7 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 14295
21 May 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084106
4 March 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427180
15 May 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 916058
5 May 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394329
28 October 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868921
4 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 882372
4 March 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857693
23 April 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137149
6 March 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943068
31 May 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931995
29 April 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 929506
18 April 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924326
8 March 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1224663
10 April 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1196331
24 March 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195266
9 November 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 532830
11 March 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1028969
23 April 1987
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1332347
4 November 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 312566
31 March 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998829
31 March 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1301065
2 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 987648
27 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 299117
29 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974889
11 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973484
15 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 975648
11 April 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271664
16 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964182
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 July 2005
Resolved
Install proper insulation/guard on prome mover exhaust.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 1 August 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 July 2005
Resolved
Make proper repairs to leak in union on the fuel tank return line.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 1 August 2006
Engineering › Diesel Engine (auxiliary) › Gear, Timing
Issued 21 July 2005
Resolved
Prove proper operation of RPM guage for prime mover.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 1 August 2006
Engineering › Diesel Engine (auxiliary) › Block
Issued 21 May 2004
Resolved
Cover engine exhaust on prime mover. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 20 June 2004
Resolved 22 June 2004
Resolution: Cover installed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 21 May 2004
Resolved
Paint draft marks a contrasting color of the hull paint.
Condition: Improper Installation
Due 20 June 2004
Resolved 22 June 2004
Resolution: Draft marks repainted.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 May 2004
Resolved
Provide fixed containment for lube oil pump on starboard side.
Condition: Unknown
Due 20 June 2004
Resolved 22 June 2004
Resolution: Containment installed.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 May 2004
Resolved
Move drain line for on deck lube oil tank inside containment area.
Condition: Improper Installation
Due 20 June 2004
Resolved 22 June 2004
Resolution: Drain line moved as required.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 21 May 2004
Resolved
Provide/install overfill protection for on deck lube oil tank.
Condition: Unknown
Due 20 June 2004
Resolved 22 June 2004
Resolution: Rising stick gauge installed.
Construction/Loadline › Hull
Issued 14 July 2003
Resolved
Required vessel rep to gauge the deck in way of the bow rake and #1 port and starboard cargo tanks due heavy pitting. LEGACY COMPONENT DESC: Deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 23 July 2003
Resolution: Deck was gauged. Report showed that wastage was within allowage percentages. Specific pits were identified and clad welded.
Construction/Loadline › Hull
Issued 3 July 2003
Resolved
Vessels COI indicated dry dock dates required for freshwater service. Vessel is in salt water service and dry dock should have been conducted in January of 2003. Informed vessel rep to make arrangements to dry dock immediately.
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 15 July 2003
Resolution: Examined vessel on drydock.
Construction/Loadline › Markings
Issued 16 July 2002
Resolved
Vessel's name and hailing port were missing on the stern. Name and hailing port had been painted over in black. Name and hailing port must be properly marked as required by 46 CFR 67.123. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel painted name and hailing port on the stern.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 July 2002
Resolved
Flame screens on two aft pressure vacuum valves were clogged with paint. Both screens must be replaced or cleaned, and properly installed as required by 46 CFR 32.20-10. LEGACY COMPONENT DESC: Pressure/Vacuum Relief Valve
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Witnessed the installation of new flame screens for the two aft pressure vacuum valves.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 July 2002
Resolved
Flame screens on No. 1 port and starboard cargo tanks were torn. New flame screens to be installed as required by 46 CFR 32.20-10. LEGACY COMPONENT DESC: Flame Screens
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Witnessed the installation of new flame screens for number one port and starboard cargo tanks.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 July 2002
Resolved
Machinery guard on the lube oil transfer hydraulic motor was hanging loose and not attached on one side. Guard must be properly installed as required by 46 CFR 32.02-15. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel rep properly secured the machinery guard on the lube oil transfer hydraulic motor.
Communications › Visual Communication
Issued 16 July 2002
Resolved
Warning sign lettering was missing or badly faded, making it unreadable. Sign to be repaired in accordance with 46 CFR 35.30-1(b). LEGACY COMPONENT DESC: Warning Sign (gangway)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel rep re-painted the lettering on the warning sign.
Engineering › Diesel Engine (auxiliary)
Issued 16 July 2002
Resolved
Fuel oil tank supply valve to the cargo prime mover inoperable, would not close. LEGACY COMPONENT DESC: Fuel Supply Stop Valve
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel rep install new fuel oil tank supply valve.
Accommodation/Occupational Safety › Potable Water System
Issued 16 July 2002
Resolved
Missing insect screens in gooseneck vents on both potable water tanks. Also, loose blank flanges held by one or two bolts on top of both potable water tanks, leaving visible gaps into the tanks. LEGACY COMPONENT DESC: Insect Screens
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel rep installed new insect screens on gooseneck vent for the potable water tanks.
Documentation › Manuals/Policy Documentation
Issued 16 July 2002
Resolved
Transfer procedures did not follow the prescribed order or use a cross-reference index page as required by 33 CFR 155.750. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 13 August 2002
Resolution: Vessel rep up-dated the transfer procedures to comply with 33 CFR 155.750.
Deck/Cargo
Issued 23 May 2001
Resolved
Prove proper operation of cargo pump engine and emergency shutdown.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Construction/Loadline
Issued 22 February 2000
Resolved
Repair three cracks IWO #2 port cargo tank.
Condition: Unknown
Due 22 February 2000
Resolved 25 April 2000
Construction/Loadline
Issued 22 February 2000
Resolved
Paint draft marks
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Deck/Cargo
Issued 22 February 2000
Resolved
Replace saturated absorbent material and missing items in spill cleanup kit.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Construction/Loadline
Issued 22 February 2000
Resolved
Replace forward keval.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Deck/Cargo
Issued 16 March 1999
Resolved
REPAIR/REPLACE EXCESSIVE LEAK ON THE WATER PUMP FOR THE PRIME MOVER.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Deck/Cargo
Issued 16 March 1999
Resolved
REPLACE PACKING AROUND THE TURN SHAFT FOR THE REACH RODS.
Condition: Unknown
Due 16 March 1999
Resolved 16 March 1999
Deck/Cargo
Issued 6 February 1998
Resolved
REPAIR, AS ORIGINAL, EXHAUST LEAK ON CARGO PUMP EXHAUST LINE.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Deck/Cargo
Issued 6 February 1998
Resolved
REPAIR/REPLACE RPM INDICATOR FOR CARGO PUMP.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Deck/Cargo
Issued 6 February 1998
Resolved
INSTALL OVERFILL PROTECTION ON BOARD BARGE AS PER 33 CFR 155.480.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Construction/Loadline
Issued 6 February 1998
Resolved
RESTENCIL DRAFT MARKS ON PORT/STBD SIDES OF BARGE.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Deck/Cargo
Issued 6 February 1998
Resolved
PROVIDE PROPER SUPPORT FOR CARGO PUMP EMERGENCY SHUTDOWN CABLE FOR PREVENTION FROM CHAFING.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Accommodation/Occupational Safety
Issued 6 February 1998
Resolved
REPAIR ACCESS LADDER SERVING TOP OF PORTABLE WATER TANK.
Condition: Unknown
Due 12 February 1998
Resolved 25 February 1998
Documentation
Issued 6 February 1998
Resolved
PROVIDE ON BOARD BARGE OIL DISCHARGE PROHIBITED PLACARD AS PER 33 CFR 155.450.
Condition: Unknown
Due 6 February 1998
Resolved 25 February 1998
Deck/Cargo
Issued 30 January 1998
Resolved
A LEAK NEAR #1P/2P CARGO TANK ON SIDE SHELL AND AT THE TURN OF DECK TO SIDESHELL. VESSEL NOT TO CARRY ANY CARGO, MAKE VESSEL GAS-FREE AND READY FOR FURTHER INSPECTION.
Condition: Unknown
Due 30 January 1998
Resolved 2 February 1998
Construction/Loadline
Issued 29 April 1991
Resolved
DRYDOCK VESSEL AND MAKE AVAILABLE FOR CG EXAMINATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Deck/Cargo
Issued 8 March 1990
Resolved
GAS FREE AND MAKE AVAILABLE RAKE ENDS AND CARGO TANKS FOR THE REQUIRED INTERNAL EXAMINATION. THIS REQUIREMENT SHALL BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Documentation
Issued 11 March 1988
Resolved
PROVIDE VALID DOCUMENTATION STICKER.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Deck/Cargo
Issued 27 November 1984
Resolved
NO FLAME SCREENS.
Condition: Unknown
Due 28 November 1984
Resolved 27 November 1984
Deck/Cargo
Issued 11 April 1984
Resolved
CONDUCT A HYDRO TEST OF THE CARGO PIPING SYS AS REQUIRED BY 33 CFR 156.170 DOCUMENTARY EVIDENCE OF THE TEST & RESULTS SHALL BE SUBMITTED TO OCMI MOBMS
Condition: Unknown
Due 30 April 1984
Resolved 11 April 1984
Deck/Cargo
Issued 15 March 1984
Resolved
CONDUCT HYDRO TEST 225 PSI OF THE CARGO PIPING.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Deck/Cargo
Issued 15 March 1984
Resolved
D.1.B. AT THE NEXT REQUIRED INTERNAL EXAM OR THE NEXT TIME THE T/B IS GAS- FREED FOR ANY REASON, WHICHEVER COMES FIRST, CONDUCT A HYDRO TEST OF THE
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Deck/Cargo
Issued 15 March 1984
Resolved
D.1.A. CONDUCT A PRESSURE TEST OF THE CARGO PIPING SYSTEM. THE TEST MEDIUM MAY BE WATER OR CARGO. TEST PRESSURE SHALL BE AT LEAST EQUAL TO THE SET
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984