Records from 1981 to 2009. Most recent: inspection, 27 March 2009.
Inspection history · 48
27 March 2009
Deficiency Check · Re-Inspection · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3449983
28 February 2008
Deficiency Check · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3155538
23 March 2007
Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2893813
7 March 2007
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2883711
24 May 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2652808
7 February 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2580566
31 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2589046
9 February 2005
Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2289152
17 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2008098
19 February 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1746391
19 February 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489319
16 February 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376506
24 February 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369546
19 February 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411815
25 March 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390748
12 April 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400550
28 March 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447557
27 February 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886156
24 March 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416106
10 May 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358400
17 November 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412578
6 May 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1140827
27 April 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 954127
25 November 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938547
3 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224855
11 May 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240088
19 December 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909693
16 June 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208042
21 February 1989
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1349633
16 February 1989
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1347195
12 July 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1209618
16 June 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 891228
14 January 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319735
23 July 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330318
25 June 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1317094
18 July 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 996275
3 July 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1309262
9 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997934
3 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290560
7 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981202
4 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976646
28 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283887
12 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978931
14 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963408
24 January 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969801
13 July 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279918
14 December 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966841
20 July 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963838
Stability › Watertight Integrity › General
Issued 27 April 2009
Resolved
Adjust watertight door so it closes properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2009
Resolution: Door adjusted and closes properly.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 April 2009
Resolved
Swing compass and provide new compass deviation table.
Due 27 May 2009
Resolved 30 April 2009
Resolution: Compass deviation table provided.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 April 2009
Resolved
Mde guages on bridge were not functioning or malfunctioning, repair or replace as needed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2009
Resolution: All guages repaired or replaced and operating correctly.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 April 2009
Resolved
Replace 17 Kapok lifejackets that were beyond servicable life.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2009
Resolution: Lifejackers were replaced.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 17 February 2004
Resolved
Some wiring contained wire nuts. Operator secured properly while we were there.
Condition: Improper Installation
Due 18 February 2004
Resolved 18 February 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 17 February 2004
Resolved
Switches for system not labeled. Identical switch boxes as vents and other systems. Crew relabeled them properly while we were there. LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Due 18 February 2004
Resolved 18 February 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 February 2004
Resolved
Missing knob on switchboard for ammeter. Replaced while we were there.
Condition: Improper/Lack of Maintenance
Due 18 February 2004
Resolved 18 February 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 February 2004
Resolved
Missing labels for circuit breakers in box, a big mess. Electrician was correcting problem before we left.
Condition: Improper/Lack of Maintenance
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting › Fire Pumps
Issued 17 February 2004
Resolved
Fire pump would not reach 60 psi with one hose open. Crew disassembled unit and replaced parts and renewed the gauge. Showed proper operation before we left. LEGACY COMPONENT DESC: Impeller
Condition: Improper/Lack of Maintenance
Due 18 February 2004
Resolved 18 February 2004
Engineering › Pressure Vessel › Pressure Gauge
Issued 17 February 2004
Resolved
Gauge too small, only went up to 160 psi when MAWP is 200 psi. Ordered them to replace with proper gauge.
Condition: Improper Installation
Due 19 February 2004
Resolved 19 February 2004
Resolution: Replaced and showed invoice for new gauges.
Navigation
Issued 17 February 2004
Resolved
One nav light burnt out. Replaced on the spot.
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 February 2004
Resolved
Lifeline not readily deployable. Crew fixed on the spot with a breakaway set up. LEGACY COMPONENT DESC: Lifeline
Condition: Improper Installation
Due 18 February 2004
Resolved 18 February 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 17 February 2004
Resolved
Light over stove not properly covered. Crew was working on that while we were there.
Due 18 February 2004
Resolved 18 February 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 February 2004
Resolved
Crew could not show operation of OWS. Unit appeared to be functioning, but could not be confirmed. No ability to introduce oily water into system to test.
Due 18 February 2004
Resolved 18 February 2004
Navigation › Collision/Grounding Avoidance
Issued 24 February 2003
Resolved
PAINT BOTH STARBOARD AND PORT RUNNING LIGHTS BACKGROUND MAT BLACK. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 25 February 2003
Communications › Internal Communications System
Issued 24 February 2003
Resolved
INSTALL PA SYSTEM THROUGHOUT VESSEL. LEGACY COMPONENT DESC: PA SYSTEM
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2003
Resolved 25 February 2003
Navigation › Piloting/Steering › Compass Deviation Table
Issued 19 February 2003
Resolved
CONDUCT COMPASS DEVIATION TEST.
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 February 2003
Construction/Loadline › Hull › Weld
Issued 19 February 2002
Resolved
Found cracked weld on fuel tank IWO stbd side engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Fuel tank inerted under supervision of marine chemist, crack gouged and welded.
Fire Fighting › Fire Pumps › Pressure
Issued 19 February 2002
Resolved
Fire pump pressure inadequate, demonstrat fire main IAW 46 CFR 181.300(a)(iii)(b), 60 psi @50 gpm.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Replaced fire pump, cleaned barnacles from sea chest.
Stability › Watertight Integrity
Issued 19 February 2002
Resolved
Engine room soft patches leaking, reseal. LEGACY COMPONENT DESC: Main Deck engine Hatches
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Soft patches resealed.
Lifesaving › Buoyant Apparatus
Issued 19 February 2002
Resolved
Replace 2 ea worn life floats
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Floats replced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 February 2002
Resolved
Provide Life jacket specific donning instructions.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Jackets provided
Fire Fighting › Miscellaneous Items
Issued 19 February 2002
Resolved
Name missing on fire axe. LEGACY COMPONENT DESC: Fire axe
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Name stensiuled on fire axe.
Electrical › Electric Supply System (service) › Cable
Issued 19 February 2002
Resolved
Properly secure wires in stuffing tube on fuel oil transfer pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2002
Resolved 20 February 2002
Resolution: Wires secured.
Construction/Loadline
Issued 16 February 1989
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGES LOCATED AFT AT THE ENGINE EXHAUST BOXPRIOR TO SAILING.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Fire Fighting
Issued 16 June 1988
Resolved
DEMONSTRATE PROPER OPERATION OF FIRE MONITOR.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 16 June 1988
Resolved
INSTALL NEW AXLE IN WATERTIGHT DOOR DOGGING ASSEMBLY FOR WATERTIGHT DOOR BETWEEN ENGINE ROOM AND GALLEY.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Accommodation/Occupational Safety
Issued 25 June 1987
Resolved
REPLACE ALL BROKEN WINDOWS LOCATED IN THE SUPERSTRUCTURE.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Electrical
Issued 25 June 1987
Resolved
REPLACE MISSING BULBS ON THE ELECTRICAL SWITCHBOARD IN THE ENGINE ROOM.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Deck/Cargo
Issued 25 June 1987
Resolved
REPLACE SCREEN GUARDS ON BOTH PORT AND STARBOARD VENTILATORS IN THE MACHINERY SPACE.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Navigation
Issued 3 July 1986
Resolved
REPLACE OR REPAIR AN INOPERATIVE LORAN-C UNIT ON THE BRIDGE.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Engineering
Issued 3 July 1986
Resolved
OPEN BOTH PRESSURE VESSELS FOR INSPECTION FOR THE UPCOMING DRYDOCK EXAM.
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986
Navigation
Issued 3 July 1985
Resolved
REMOVE OR REPAIR THE BRIDGE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Construction/Loadline
Issued 3 July 1985
Resolved
CORRECT THE SIGN ON THE GALLEY TO THE ENGINE ROOM WATERTIGHT DOOR TO READ "KEEP CLOSED AT ALL TIMES EXCEPT WHEN USED FOR TRANSIT".
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Engineering
Issued 3 July 1985
Resolved
INSTALL SCREEN OR EXPANDED METAL COVERS OVER THE VIBRATION DAMPERS ON THE FORWARD SECTION OF EACH MAIN ENGINE.
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Accommodation/Occupational Safety
Issued 3 July 1985
Resolved
REPAIR OR REPLACE THE ELECTRICAL CONTROL BOX FOR THE MSD VACUUM PUMP.
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Construction/Loadline
Issued 3 July 1985
Resolved
MAKE EFFECTIVE REPAIRS TO THE DEEP WEB FRAME IN THE STEERING VOID.
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985