Records from 1998 to 2026. Most recent: inspection, 3 February 2026.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 24.0 ft × 6.2 ft
Registered tonnagegross 80 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLLINS SEAFOOD INC · LAROSE, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 31 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
3 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305714
22 January 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299974
18 December 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8049034
25 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7856348
4 January 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7616531
22 December 2021
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7377929
2 November 2021
Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7343745
18 July 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4686692
30 April 2013
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 4580737
15 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4361135
8 October 2009
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3611321
28 September 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2789304
21 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2630307
13 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2624123
31 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2589046
6 July 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2122955
8 November 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120861
3 November 1998
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 729650
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 January 2023
Resolved
Each towing vessel must be maintained and operated to minimize fire hazards. Vessel had bilge with oil due to port MDE clutch breaking, vessel had a Windex bottle of diesel hanging right near the Center MDE Racor, and vessel had a leak for the Fuel Oil Discharge pipe.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Vessel cleared the bildge, removed the windex bottle and the secured the dischage pipe leak.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 4 January 2023
Resolved
Each towing vessel must be maintained and operated to minimize fire hazards and IAW Nonmetallic Fuel Hose requirements. The vessel had multiple nonmetallic fuel hoses that were either severely chaffed, deteriorated, or cracking.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Vessel replaced fuel hoses throughout vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 January 2023
Resolved
Electrical systems and equipment must function properly, minimize system failures, and fire and shock hazards. Electrical outlet in ER was using splitter to hold E-Light cord & other vital systems being held by ducttape.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Vessel repositioned the electrical outlet, removed the splitter, and replaced cord.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 January 2023
Resolved
Propulsion machinery must be maintained to ensure proper operation. Vessel's port MDE clutch was not operational.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Vessel repaired the broken gasket. Crew indicated that there was a slight fracture which will be replaced shortly.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 4 January 2023
Resolved
Master shall have valid credentials to operate the vessel. One Licensed Master did not have his Medical Certificate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Crew member had submitted for new medical card. Vessel changed crew.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 4 January 2023
Resolved
Master shall have proper a restricted Radiotelephone Operator license or higher. Different licensed Master did not have any radio license.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 January 2023
Resolution: Vessel changed crew.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 January 2023
Resolved
Vessel shall have reliable means to notify emergency conditions exists or essential system develops problems. Vessel Alarm panel's Bilge light did not function; auditory bell was not functional until adjusted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Vessel replaced light and auditory was working at the time of the def check.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 January 2023
Resolved
Engine Room Watertight door and bridge weather-tight door shall maintain watertight integrity or weather-tight integrity respectively. ER WTD and Bridge weather-tight door had gasket that would not maintain the required integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: New gasket material was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 January 2023
Resolved
Electrical systems and equipment must function properly, minimize system failures, and fire and shock hazards. Electrical Panel had a blank electrical socket exposed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Placed blank into electrical panel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 January 2023
Resolved
Vessel shall maintain the proper Visual Distress Signals per the route of the COI. Vessel did not have the proper VDS (6 Red and 6 Orange; vessel not limited to <3nm LBS)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Vessel had received new flares, 10R & 2O.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 January 2023
Resolved
Vessel shall ensure the survival craft is properly stowed and equipped. The lifefloat was on the deck w/o a painter, weak link, or floating electric water light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Survival Craft was in cradle, properly marked, secured, and equiped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 January 2023
Resolved
Vessel shall have up to date Charts and Pubs. Vessel only had one electric chart that was last updated 10/22. No paper charts were on-board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Vessel had updated electronic charts and paper charts.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 4 January 2023
Resolved
Emergency Broadcast Placard shall be posted at operating station. Vessel did not have an Emergency Brodcast Placard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Vessel posted new Emergency Brodcast Placard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 January 2023
Resolved
Emergency Lights shall be capable to illuminate emergency escape exits. The ER and the Galley E-Light were not operational when tested; ER light had frayed cord while the galley needed new battery installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Emergency battery were replaced. Cord was replaced. New installiation of LED for engine room was preformed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 January 2023
Resolved
Piping shall be clearly marked or color coded. The piping system for fuel, fire fighting, and ballast were not color coded or properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2023
Resolved 13 January 2023
Resolution: Color piping diagram was posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 January 2023
Resolved
Interior Smoke Alarms shall be installed and operational in all berthing space and lounges. Bridge, with berthing rack installed had a smoke detector that was not operational.
Action required: 10 - Deficiency Rectified
Resolved 4 January 2023
Resolution: Vessel installed a new battery for the bridge smoke detector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 January 2023
Resolved
Vessel shall have a fixed fire pump and fire main. Vessel has a cotton-jacketed flex hose (non-fire retardant) attached from the fire main piping to another part of fixed piping. 705 - Vessel shall rectify at next drydock.
Action required: 705 - Other - as specified
Due 30 November 2026
Resolved 22 January 2026
Resolution: Replaced flex hose with fixed hard piping.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 4 January 2023
Resolved
Vessel shall have a depth sounder installed for vessels with a LBS route or above. Vessel does not have a depth sounder installed. 705 - Vessel shall rectify at next drydock.
Action required: 705 - Other - as specified
Due 30 November 2026
Resolved 22 January 2026
Resolution: Depth sounder installed.