Records from 1984 to 1998. Most recent: operational control imposed, 4 November 1998.
Inspection history · 61
4 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 167857
4 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422281
22 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 421595
22 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 803085
1 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421003
6 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417558
22 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 41412
13 November 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 785724
2 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403309
23 April 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 402726
11 January 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 399418
29 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395799
29 September 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1139437
29 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 132862
10 June 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 391747
21 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191928
21 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765663
1 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 146716
9 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 191927
9 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382479
9 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765730
12 June 1995
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 379199
14 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 372428
4 August 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 369079
4 August 1994
MARPOL Annex V Examination · Letter of Compliance (Initial/Renewal) · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868025
25 April 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 499920
25 April 1992
MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955382
22 January 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 506752
30 July 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1246747
12 August 1990
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1215049
4 August 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 907685
11 May 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 336981
7 February 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1223232
5 February 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 501054
1 August 1989
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1036221
1 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1218144
5 May 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 467579
10 January 1989
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1043622
12 October 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1203574
11 October 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326343
11 April 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1338139
15 March 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1336909
10 March 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 540079
27 February 1988
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1026955
23 February 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1330112
25 September 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 318714
28 August 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1000757
25 August 1987
Certificate of Compliance · MARPOL Annex II Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1011265
13 May 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 459060
13 May 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1025131
28 October 1986
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1023930
26 October 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 312172
14 July 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 448057
7 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287836
29 March 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 482290
29 March 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 526967
20 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 536902
18 December 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 299542
6 December 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 299613
30 November 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 299107
5 August 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 470236
Engineering
Issued 22 October 1998
Resolved
VAPOR COLLECTION SYSTEM NOT MARKED PROPERLY. PAINT ONE METER AT MANIFOLD, .1 METER RED, .8 METER YELLOW, .1 METER RED. LABEL CONNECTION "VAPOR".
Condition: Unknown
Due 22 November 1998
Resolved 3 November 1998
Engineering
Issued 22 October 1998
Resolved
1/2 INCH STUD NOT AFFIXED AT 12 O'CLOCK POSITION ON FLANGE.
Condition: Unknown
Due 22 November 1998
Resolved 3 November 1998
Engineering
Issued 11 January 1997
Resolved
OILYWATER SEPARATOR WAS DISASEMBLED AND NOT OPERATIONAL. PROVE PROPER OPERATION BY 11FEB97.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Electrical
Issued 11 January 1997
Resolved
THE EMERGENCY GENERATOR COULD NOT BE STARTED. THE AIR START MECHANISM WAS BROKEN AND BOTH SETS OF BATTERY BANKS WERE DEPLETED. CLASS SURVEYORS REPORTREQUIRED PRIOR TO DEPARTING ZONE.
Condition: Unknown
Due 18 January 1997
Resolved 22 January 1997
Deck/Cargo
Issued 11 January 1997
Resolved
CARGO TANK HIGH LEVEL ALARMS WERE NOT WORKING ON DECK. CLASS SURVEYORS REPORT REQUIRED PRIOR TO DEPARTING ZONE. NO CARGO MAY BE LOADED WHILE IN THE HOUSTON GALVESTON ZONE.
Condition: Unknown
Due 18 January 1997
Resolved 22 January 1997
Fire Fighting
Issued 29 September 1996
Resolved
Repair fire-main valve just forward of deckhouse on maindeck to provide adequate water pressure to the accomodation spaces to the satisfaction of local CG Marine Inspector, as per SOLAS 74 II-2 reg 5 (e).
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Deck/Cargo
Issued 29 September 1996
Resolved
Provide Drager tubes for styrene prior to loading styrene as cargo, as per BCH 3.11.1.
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Documentation
Issued 9 September 1995
Resolved
SUBMIT CURRENT CERTIFICATE OF FITNESS TO WASHINGTON, D.C. (USCG, MARINE SAFETY CENTER) PRIOR TO NEXT U.S. PORT CALL. UPON APPROVAL FROM MSC A NEW SUBCHAPTER "0" ENDORSEMENT WILL BE ISSUED._x001C_ _x001C_
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 9 September 1995
Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR (OWS) AND PROVIDE CLASS REPORT TO U.S. COAST GUARD.
Condition: Unknown
Due 15 October 1995
Resolved 15 October 1995
Deck/Cargo
Issued 9 September 1995
Resolved
DEMONSTRATE OPERATION OF AUDIBLE HIGH LEVEL AND OVERFLOW ALARMS ON THE OPENDECK. PROVIDE CLASS REPORT TO U.S. COAST GUARD.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Documentation
Issued 9 September 1995
Resolved
UPDATE CURRENT OIL TRANSFER PROCEDURES TO INCLUDE VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 15 October 1995
Resolved 15 October 1995
Deck/Cargo
Issued 9 September 1995
Resolved
DEMONSTRATE PROPER OPERATION OF INERT GAS SYSTEM (IGS) AND PROVIDE CLASS REPORT TO U.S. COAST GUARD.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 9 September 1995
Resolved
PROFESSIONALLY SERVICE ALL SELF-CONTAINED BREATHING APPARATUS (SCBA'S) AND PROVIDE SERVICING REPORT TO U.S. COAST GUARD.
Condition: Unknown
Due 15 October 1995
Resolved 15 October 1995
Deck/Cargo
Issued 9 September 1995
Resolved
PROFESSIONALLY SERVICE O2 ANALYZER ON INERT GAS SYSTEM (IGS) AND PROVIDE U.S. COAST GUARD WITH SERVING REPORT.
Condition: Unknown
Due 15 October 1995
Resolved 15 October 1995
Electrical
Issued 9 September 1995
Resolved
DEMONSTRATE PROPER OPERATION OF F/O CUT-OUT VALVE FOR EMERGENCY GENERATOR DAYTANK.
Condition: Unknown
Due 15 October 1995
Resolved 15 October 1995
Fire Fighting
Issued 4 August 1994
Resolved
REPAIR EMERGENCY FIRE PUMP TO THE SATISFACTION OF THE ATTENDING MARINE _x001C_ INSPECTOR PRIOR TO DEPARTURE FROM NEW YORK.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Engineering
Issued 12 August 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF SECONDARY "KAMEWAH" HYDRAULIC SYSTEM PUMP (VARIABLE PITCH PROPELLER UNIT), NO LATER THAN 14AUG90.
Condition: Unknown
Due 12 August 1990
Resolved 12 August 1990
Navigation
Issued 4 August 1990
Resolved
NO MEANS TO CHECK CONTENT IN RESERSE HYD. STEERING FLUID TANK SOLAS CHII-1 REG 29.12.3
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Fire Fighting
Issued 4 August 1990
Resolved
NO MARKINGS ON BOXES FOR FIRE PLAN. SOLAS CHII-2 REG 20.
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Navigation
Issued 4 August 1990
Resolved
NO LOSS OF POWER STEERING SYSTEM ALARM ON BRIDGE SOLAS CHII-1 REG 28.12.3
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Deck/Cargo
Issued 4 August 1990
Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL'S CERTIFICATE OF FITNESS AUTHORIZES THE CARRIAGE OF POLYBUTENE. SUBCHAPTER O ENDORSMENT TO LOC CARD.
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Deck/Cargo
Issued 4 August 1990
Resolved
BLANKS NOT INSTALLED IN THE HEATING COILS FOR THE STYRENE MONOMER. 46 CFR 1002(B)
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Deck/Cargo
Issued 4 August 1990
Resolved
PROVIDE A MANUFACTURE'S LETTER FOR THE XYLENE CARRIED ONBOARD. 46 CFR 908 (B)
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Deck/Cargo
Issued 4 August 1990
Resolved
NO HIGH AUIBLE ALARMS PROVIDED FO XYLENE TURPENTINE + WHITE SPIRIT (VARSOL)46 CFR 155.409
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Deck/Cargo
Issued 4 August 1990
Resolved
FLAME SCREENS FOR BUNKER TANKS DETERORIATED. 46 CFR 35
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Fire Fighting
Issued 4 August 1990
Resolved
SPANNERS WRENCHES MISSING IN FIRE BOXES. 46 CFR 34.10(D)
Condition: Unknown
Due 4 August 1990
Resolved 4 August 1990
Unknown
Issued 1 August 1989
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO PIPING TO 1 1/2 MAWP.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Unknown
Issued 1 August 1989
Resolved
MAKE PERMANENT REPAIRS TO #3 CENTER CARGO TANK CARGO LINE IN WAY OF TEMPORARY REPAIRS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Unknown
Issued 12 October 1988
Resolved
MAKE PERMANENT REPAIRS TO HIGH LEVEL ALARMS ON 12 DECK TANKS PRIOR TO CARRYING CARGOES REQUIRING HIGH LEVEL ALARMS IN U.S. WATERS.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Unknown
Issued 12 October 1988
Resolved
DEMONSTRATE PROPER OPERATION OF IGS.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Navigation
Issued 11 October 1988
Resolved
33CFR164.33(A)(2)(II) COAST GUARD LIGHT LIST VOLUME IV UNCORRECTED. AUTH: 33USC1223 PENALTY: 33USC1232
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Documentation
Issued 11 October 1988
Resolved
33CFR151.19(D) VESSEL DID NOT HAVE AN INTERNATIONAL OIL POLLUTION CERTIFICATE SUPPLEMENT (B). AUTH: 33USC1904 PENALTY: 33USC1908
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Documentation
Issued 11 October 1988
Resolved
33CFR155.750 INCOMPLETE OIL TRANSFER PROCEDURES MISSING ITEMS REQUIRED BY 33CFR155.750(A)(1),(A)(2)(II),(A)(2)(III),(A)(3),(A)(4), AND (A)(7). AUTH: 33USC1321 PENALTY: 33USC1321
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Navigation
Issued 25 September 1987
Resolved
33CFR164.37 SECONDARY RADAR INOPERABLE [33 USC 1223(3)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Documentation
Issued 25 September 1987
Resolved
VESSEL FOUND CARRYING HAZARDOUS, NOXIOUS-LIQUID SUBSTANCES,(NLS), CARGOS INTO U.S. WATERS WITHOUT A VALID LETTER OF COMPLIANCE, AS REQUIRED BY; [46 CFR 153.5, 46 USC 3711 (A)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Navigation
Issued 25 September 1987
Resolved
FAILURE TO NOTIFY COTP GALVESTON OF INOPERATIVE SECONDARY RADAR,AS REQUIRED[33 CFR 164.53 (B), 33 USC 1223 (5)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
VESSEL WAS UNABLE TO DETERMINE O2 CONTENT OF CARGO TANKS DUE TO LACK OF PORTABLE O2 DETECTOR ON BOARD. (IMO RESOLUTION A 212 X; 5.4.1)
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
INOPERABLE HIGH TEMPERATURE ALARMS AND GAUGES FOR THE FOLLOWING CARGO TANKS; WINGS 4P, 2S, 10S, 11S; CENTER 9S AND DECK 6S.[IMO RESOLUTION A 212.X; 2.15.5, 46 CFR 153.44(A)(1)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
98% HHL ALARM AND QC VALVE SYSTEM TESTED AND FOUND TO BE INOPERATIVE.
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
FAILURE TO NOTIFY COTP GALVESTON OF INOPERATIVE 98% HHL ALARM AND QC VALVE OVERFLOW EMERGENCY SHUTDOWN IN VIOLATION OF 46 CFR 153.5.
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Lifesaving
Issued 25 September 1987
Resolved
EMERGENCY EQUIPMENT WAS NOT STOWED AS PER THE VESSEL SAFETY PLAN AND WAS GENERALLY UNAVAILABLE. (46 CFR 35.30-20, 46 CFR 153.975, IMO RESOLUTION A 212 X; 3.16.2)
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Documentation
Issued 25 September 1987
Resolved
VESSEL NOT IN POSSESSION OF APPROVED COMDT G-MTH-1 NON-CONVENTION CERTIFICATE OF FITNESS OR PROCEDURES AND ARRANGEMENT MANUAL. [46 CFR 153.15(B)(3)&(4), 33 USC 3711(A)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
OIL TRANSFER HOSE HAD NOT BEEN HYDROSTATICALLY TESTED WITHIN THE LAST YEAR.(33 CFR 156.170)
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Deck/Cargo
Issued 25 September 1987
Resolved
15 OF 20 TESTED PRESSURE VACUUM VALVES WERE FOUND TO BE INOPERATIVE ON THE VACUUM SIDE. [IMO RESOLUTION A 212 X; 2.14.2, 33 USC 1223(1) AND 46 CFR 153.957(K)(9)]
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Documentation
Issued 28 August 1987
Resolved
UPON CLASS SOCIETY APPROVAL OF P&A MANUAL, SUBMIT COPY TO COMMANDANT (G-MTH). OBTAIN AND PLACE ABOARD NEW SOE.
Condition: Unknown
Due 28 August 1987
Resolved 28 August 1987
Navigation
Issued 28 October 1986
Resolved
MODIFY STEERING GEAR TO COMPLY WITH SOLAS 74 II-1, 29.12 AND 29.13 WHICH CAME INTO EFFECT 01SEP86.
Condition: Unknown
Due 28 October 1986
Resolved 28 October 1986
Navigation
Issued 6 December 1984
Resolved
CHARTS OF TAMPA BAY WERE OUTDATED.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Navigation
Issued 6 December 1984
Resolved
U.S. COAST PILOT WAS OUTDATED.
Condition: Unknown
Due 6 December 1984
Resolved 6 December 1984
Deck/Cargo
Issued 30 November 1984
Resolved
MAKE ALL HIGH LEVEL ALARMS IN WING TANKS OPERATIVE IN ACCORDANCE WITH 46 CFR 153.409.
Condition: Unknown
Due 18 December 1984
Resolved 30 November 1984
Navigation
Issued 30 November 1984
Resolved
PROVIDE UPDATED NAVIGATION CHARTS FOR AREA AS REQUIRED BY 33 CFR 164.33 (A)(1)(II). PROVIDE ONBOARD TIDE TABLES (ATLANTIC AREA) AS REQUIRED BY 33CFR164.33(A)(2)(IV).
Condition: Unknown
Due 18 December 1984
Resolved 30 November 1984