Records from 1984 to 1992. Most recent: inspection, 16 December 1992.
Inspection history · 22
16 December 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 355156
22 September 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 937038
4 August 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 485702
6 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 182660
26 March 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 949324
5 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 680682
5 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 680705
31 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 35478
3 January 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258938
16 November 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 446978
17 April 1990
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 925314
21 February 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335439
21 February 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1239364
24 July 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1331185
27 May 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1309658
2 May 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1017673
6 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309997
6 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296593
29 November 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305656
19 November 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305456
4 April 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 475712
29 August 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 298092
Deck/Cargo
Issued 3 January 1992
Resolved
Carriage of cargo requiring closed guaging and quick closing valves prohibited in C/L tanks until both systems fully operational. Systems damaged by solidification of waxes in the tanks during cargo heating plant shutdown. Contaminated fuel suspected for plant shutdown.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Lifesaving
Issued 3 January 1992
Resolved
Install SOLAS approved Retro-Reflective tape on ring life bouys.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Lifesaving
Issued 3 January 1992
Resolved
Install SOLAS approved lights on all lifejackets aboard vessel.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Deck/Cargo
Issued 21 February 1990
Resolved
COMPLETE SATIFACTORY TEST OF ALL CARGO PIPING TO 1 1/2 TIMES MAWP PRIOR TO NEXT TRANSFER OF CARGO IN U. S. WATERS.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Deck/Cargo
Issued 24 July 1987
Resolved
REPAIR ALL CLOSED GAUGING DEVICES PRIOR TO CARRYING ANY CARGO REQUIRING CLOSED GAUGING, BUT IN NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Deck/Cargo
Issued 24 July 1987
Resolved
CONDUCT A 1-1/2 MAWP PRESSURE TEST ON THE CARGO PIPING IAW 33CFR156.170.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Deck/Cargo
Issued 24 July 1987
Resolved
PROPERLY FIT FLAME SCREENS TO VENT RISERS FOR CARGO TANKS 1P, 3S, 5P.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Documentation
Issued 24 July 1987
Resolved
SUBMIT A COPY OF NEW IMO COF TO COMMANDANT (G-MTH). OBTAIN AND PLACE ABOARD NEW USCG SOE.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Documentation
Issued 19 November 1985
Resolved
VESSEL DID NOT HAVE AN OIL RECORD BOOK(PARTS I & II) ONBOARD AS REQUIRED BY33CFR151.25. PART I & II ENTRIES CURRENTLY ENTERED IN SAME OIL RECORD BOOK.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION ONBOARD AS REQUIRED BY 33CFR155.430.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Documentation
Issued 19 November 1985
Resolved
PROVIDE ONBOARD CURRENT EDITIONS OF 46CFR PARTS 35 AND 150 IAW 46CFR153.905
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
PROVIDE A SECOND EMERGENCY SHUTDOWN STATION FOR CARGO TRANSFERS AS REQUIREDBY 46CFR153.296
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Navigation
Issued 19 November 1985
Resolved
VESSEL DID NOT HAVE TIDAL CURRENT TABLES OR FOREIGN GOVERNMENT EQUIVILENTS ONBOARD AS REQUIRED BY 33CFR164.33(A)(2).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Documentation
Issued 19 November 1985
Resolved
VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES FOR CARGO OPS ONBOARD IAW 33CFR155.720. VESSEL WAS LOADING AN OIL PRODUCT (XYLENE) & TANK CAPACITY IS GREATER THAN 250 BBLS.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985